Installation notes
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388
E-mail: [email protected] Web: www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
Products available from DANLERS
• PIRoccupancyswitches•Daylightlinkeddimmers•Manualhighfrequencydimmers
• Photocells • Radio remote controls • Time lag switches • Outdoor security switches
• Dimmers•Heating,ventilationandair-conditioningcontrols•Bespoke/O.E.M.products
Please call for more information or a free catalogue.
ThisproductconformstoBSEN60669-2-1.
Pleaseensurethemostrecenteditionoftheappropriatelocalwiringregulationsareobserved
andsuitableprotectionisprovidede.g.overcurrentprotection,1kVovervoltage.Pleaseensure
thatthisdeviceisdisconnectedfromthesupplyifaninsulationtestismade.
Thisproductiscoveredbyawarrantywhichextendsto5yearsfromthedateofmanufacture.
Precautions and Warranty
Batten Mount PIR occupancy switches
BMPIR5M BMPIR10M BMPIRSP BMPIRRH
DANLERSBattenmountpassiveinfra-redoccupancyswitches(PIR)
canbemountedontotheendoflightingbattensviathe20mmknock
out.Theswitchincludestheconnection20mmthreadand1mofwire
tails to connect to the lighting ballast.
The PIRs incorporate a passive infra-red quad sensor to detect
movementofawarmbodywithinthedetectionzoneandincludea
photocelltomonitortheambientlightlevel.
Ondetectingmovement,iftheambientlightisdarkenough,thePIR
will switch the load on. The ambient threshold can be set by the user
to between approximately 100 and 3000 lux (on the working plane)
viatheLUXadjuster.
BMPIR5Mhasa5mdiameterrange,5mmaxheight,seediag.B.
BMPIR10Mhasa10mdiameterrange,5mmaxheight,seediag.B.
BMPIRSPhasa1.5mdiameterrange,5mmaxheight,seediag.B.
BMPIRRHhasa2.5mdiameterrange,2.5mmaxheight,seediag.B.
A ‘real time’ photocell status indicator glows green when the photocell
isactiveandglowsredwhenthephotocellisinactive.
Ifnomoremovementisdetectedwithinacertaintime,thenthePIRwill
switchofftheload.ThetimecanbesetviatheinternalTIMEadjuster
to between 10seconds and 40 minutes (diagram D).
Loading
ThesePIRsshouldonlybeconnectedtoa230V50Hzacsupply.
Theycanswitchthefollowingtypeofloads:
• 10amps(2500W)resistiveloadsandtungsten
• 6amps(1500W)uorescent(switchstart)/mainshalogenlamps
 (recommendedwithintegralsafetyfuse)
• 3amps(750W)
  Electronicorwirewoundtransformers.
  CompactuorescentorLEDlamps.
NormallyOPENcontacts.
19/08/13 INS713BMPIR5M/10M/SP/RH
Wiring diagram
The PIR does not detect
• PersonistoofarfromthePIRswitch,seedetectiondiagram.
• Personismovingunusuallyslowly(perhapswhentesting).
ThePIRfalsetriggers
• Detectorisplacedtooclosetoheatormovingairsources.
Trouble shooting
L
load
optional manual
wall switch for
overriding off
N
230 VAC
SL
N
BMPIR5M/10M/SP/RH
3000
40m
20m
10m
5m
2.5m
80s
40s
20s
10s
100
up to 5m
For optimum
coverage
recommended
mounting
height: 2.4
to 5m
up to 10m
BMPIR5M BMPIR10M
100° 112°
For optimum
coverage
recommended
mounting
height: 2.4
to 5m
up to 1.5m
For optimum
coverage
recommended
mounting
height: 2.4
to 5m
BMPIRSP
20°
For optimum
coverage
recommended
mounting
height: 2.4
BMPIRRH
100°
Installation procedure
1. Pleasereadthesenotescarefullybeforecommencingwork.
Incaseofdoubtpleaseconsultaqualiedelectrician.
Makesurethepowerisisolatedfromthecircuit.
2. Removethe20mmknockoutfromtheendofthelightingbatten.
3. MakingreferencetodiagramA:Removethe20mmthreadfromthe
PIR and insert it through the 20mm knockout hole with the thread
facingoutwards
4. FeedthetrailingwiresthroughthethreadandwiththePIRfacing
downwards tighten the 20mm thread.
5. The trailing wires should be connected to the ballast as:
Brown-Livesupply.Blue-Neutralsupply.White-SwitchedLinetoballast.
6. Oncethewiringhasbeencompletedandveried,switchonthesupply
and test the operation.
Set-up
7. Whenpoweredup,(after1minutestabilisationtime)turnluxpot
fullyclockwiseandtimepotfullyanticlockwise.
8. Pressthebuttonforapproximately0.5s.TheLEDwillgogreenindi-
catingtheLUXcellisactive.(Orpressandholdbuttonforapprox.4
seconds – LED goes RED indicating Lux cell INACTIVE). Repeating
thesestepswilltogglethefunctionality.
9. Ifluxcellactive,vacateareauntilPIRswitchswitchestheloadoff
(shouldbeafter10seconds).
10.WiththeLUXasdesiredondesktopfromdaylightONLY(noarticial
light),windtheluxpotanticlockwisewhilstwavingyourhandinfront
ofthePIRcell.WhenthePIRswitchestheloadON,stopturningthe
pot.TheLuxinhibitlevelisnowset.
11. Turn the PIR time to the desired timeout.
To light
fitting
ballast
C:Lux
adjustment
D: Time
adjustment Dual colour LED
RED - PIR active, Photocell inactive
GREEN - PIR and Photocell override ON (passive LUX)
Lux Cell
Mode
PIR Lens
Time
delay
setting
Lux setting
Lux cell
PIR head - key components
Precondition Power-up Condition
LuxCellInactive
RelayOFF
LuxCellInactive
RelaycomesONfor1Min.After1min.readyfordetection.
LuxCellActive
RelayON
LuxCellActive
RelaystaysONfor1Min.After1min.readyfordetection.
LuxCellActive
RelayOFF
LuxCellActive
RelaycomesONfor1Min.After1min.readyfordetection.
LuxCellInactive
RelayON
LuxCellInactive
RelaystaysONfor1Min.After1min.readyfordetection.
A: Installation diagram,
viewed from below
B: Detection range
3000
40m
20m
10m
5m
2.5m
80s
40s
20s
10s
100

This manual suits for next models

3

Popular Accessories manuals by other brands

Quincy lab 140AE-1 operating manual

Quincy lab

Quincy lab 140AE-1 operating manual

HomePro ZIR000 user manual

HomePro

HomePro ZIR000 user manual

DOL 20SCR Technical user guide

DOL

DOL 20SCR Technical user guide

RAB Smart Task installation manual

RAB

RAB Smart Task installation manual

Kemppi KMS 300 quick guide

Kemppi

Kemppi KMS 300 quick guide

Stearns 57,500 Series Installation and service instructions

Stearns

Stearns 57,500 Series Installation and service instructions

iGuzzini TWILIGHT COPENAGHEN manual

iGuzzini

iGuzzini TWILIGHT COPENAGHEN manual

Adelaide Annexe & Canvas Avan Deluxe installation guide

Adelaide Annexe & Canvas

Adelaide Annexe & Canvas Avan Deluxe installation guide

OHAUS 5000 instruction manual

OHAUS

OHAUS 5000 instruction manual

HOME8 WLS1300 quick start guide

HOME8

HOME8 WLS1300 quick start guide

MAXBOTIX MaxSonar quick start guide

MAXBOTIX

MAXBOTIX MaxSonar quick start guide

ioSmart iSmart56 Installation and user guide

ioSmart

ioSmart iSmart56 Installation and user guide

Focusrite Scarlett 18i8 user guide

Focusrite

Focusrite Scarlett 18i8 user guide

Velleman ED38105 user manual

Velleman

Velleman ED38105 user manual

JumpSport SkyBounce user manual

JumpSport

JumpSport SkyBounce user manual

Prima-Temp PRIYA Instructions for use

Prima-Temp

Prima-Temp PRIYA Instructions for use

Tefcold BC85I-BC85I W user manual

Tefcold

Tefcold BC85I-BC85I W user manual

Vaisala WMS302 user guide

Vaisala

Vaisala WMS302 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.