- 1 -
- 3 -- 2 -
SOUND LEVEL METER
(with bluetooth communication)
User Manual
INTENDED USE
Features:
1
2
3
4
5
6
7
8
9
PRODUCT DESCRIPTION
1. Microphone
2. LCD Display
3. MAX/MIN key
4. POWER/BACKLIGHT key
5. HOLD key
6. Windscreen
7. Calibration potentiometer
8. Battery cover
9. Tripod mounting thread
1. Battery capacity indicator
2. Bluetooth symbol
3. Over range indicator
4. Data hold indicator
5. MIN value indicator
6. MAX value indicator
7. Measured dB value
8. Frequency weighting
8
LCD DISPLAY
This sound level meter is a portable and handheld digital meter to measure
sound level. Its wide application includes but not limits to construction site,
working and engineering sound level measurement. It is supported by an
app, dB-Tester, which makes the usage more user-friendly and transforms
the data set into an easier way to read.
• High accuracy
• Data hold and Max/Min hold functions
• With data export function via bluetooth function
• Compatible with Apple IOS (IOS 9.0 or above version) and
Android smartphones (Android 5.0 or above version)
OPERATING INSTRUCTION
BLUETOOTH COMMUNICATION, DATA RECORDING & EXPORTING
• Bluetooth communication
1. Download the IOS or Android “dB-Tester” APP on your smartphone.
2. Turn on your smartphone's Bluetooth and then launch the “dB-Tester” app.
3. Press and hold the “ ” key on the meter to activate or deactivate the
Bluetooth. will appear on the LCD when the Bluetooth is activated.
4. Click “ ” on the APP and choose “SoundMeter” from the device list
that now appears.
Note:
For Android version, it is necessary to allow the dB-Tester app to access
your phone's location, photos, media, and the files on your phone to
search the device and to save the data when installing the app.
If the Bluetooth connection does not work, close the app and reopen it to
try the above steps from 2.~4. again.
IOS version
Scan the QR
code to download
the dB-Tester App
To diminish other factor affecting the accuracy of the measurement, please
use the windscreen when making outdoor measurement in windy weather
or when measuring air conditioning equipment or similar.
• Turning the meter ON/OFF
a. Remove the battery cover and insert 3 AAA batteries.
b. Short press “ ” to turn on the meter.
c. Press and hold “ ” to turn off the meter.
Note: The meter is equipped with an Auto Power Off feature that shuts the
meter off after approximately 10 minutes of inactivity. The meter defaults to
Auto Power Off each time it is turned on. To disable the auto power off
function, press and hold “ ” key to turn on the meter while it is off.
“UOF” will appear on the display indicates that the auto power off function
now is disabled. The meter will now remain on until the user turns it off or
until the battery run out.
• Turning the backlight ON/OFF
Press the “ ” key to turn the backlight on or off.
• Setting alarm level if needed
a. With the meter on, press the “ ” key to display “HOLD” and then
press and hold “ ” key to enter setting mode.
b. Press the “ ” key or “ ” key to increase or decrease the alarm level
to your desired value.
c. Press the “ ” key to save the value.
Note: Alarming level can also set through APP as below,
Menu --> Settings --> Parameter Settings --> Interval and Alarm -->
Alarming level (dB). (Please refer to Page 4 - Data recording & exporting - 1.a.)
• Taking measurements
Hold the instrument comfortably in one hand (away from your body) or
position it on a tripod for long-term monitoring. Point the microphone in the
direction of the noise to take a measurement.
• Selecting the MAX/MIN value measurement
a. Press the “ ” button once to display “MIN” and the minimum recorded
dB level. The display will be updated only when reaching the lower dB
reading.
Android version
Scan the QR
code to download
the dB-Tester App
b. Press the “ ” button again to display “MAX” and the maximum
recorded dB level. The display will be updated only when the max dB
reading is exceeded.
c. Press the “ ” button again to exit MIN/MAX mode. The current
reading will now display and continually updating.
• Using the Hold function
With the meter on, press the “ ” key to display “HOLD” and the last dB
reading. Press “ ” again to exit the function.
IOS version
Android version
Scan the QR code to download
the dB-Tester App
SCAN THE QR CODE
to download USER MANUAL
in different languages
www.danoplus.com/dp-101
Need more help?
CONTACT US.
TUTORIAL VIDEO ON HOW TO USE
SoundMeter
TECHNICAL PARAMETERS
MAINTENANCE
1. Turn on the meter and carefully plug the microphone head in
1/2 inch hole of calibrator
2. Turn on the calibrator and set the calibrator to output 94dB@1KHz.
3. Use flat screwdriver to adjust the calibration potentiometer
located at the back, and make the LCD display 94.0.
4. Turn off the calibrator and remove the microphone very carefully.
The meter has been calibrated properly in the factory, the recommended
calibration interval is 1 year.
• Data recording & exporting
1. Data recording through APP on the phone (the data will be stored on the
app and can store up to 100,000 groups).
a. Click “Setting” in the “Menu”, then set the mode of reading, recording
intervals, and alarm value to your liking and save the settings.
b. Click “Record on Phone” on IOS version and “Start” on Android version
to start the recording. Real-time data and data graph will appear.
c. Click “Stop” to stop the recording
and then click “Save” in the “Menu" to
save the data. You will now be asked
to name and save the file.
d. To clear the data recorded on the
app, click “Clear” in the “Menu”.
Note: Please must save the data first after finishing the recording. The
data recorded on the app will be cleared up when you close the app.
2. Data recording on Meter (the data will be stored in the meter and can
store up to 20,000 groups).
a. Click “Setting” in the “Menu”, then set the recording intervals and the
total number of records you wish to set for your meter
Note: The meter will automatically stops recording when the saved data
reaches the total number of records you set.
b. To start the data recording, click “Start” on the app or press and hold
the “ ” key on the meter until the dBA symbol starts flashing.
c. To stop the data recording, click “Stop” on the app or press and hold
the “ ” key on the meter until the dBA symbol stops flashing.
d. Click “Export” on the app to export the stored data in the meter to the
app. Set the name and then save the file.
e. To clear the data recorded in the meter, click “Clear” on the app.
Click to start
measuring
Measured value
Data graph
- 5 -- 4 -
- 7-- 6 -
FOR IOS VERSION ONLY
• To View the data
1. Click the “data file” on the top right corner of the interface.
2. Click the “File name” to check the data.
• To share the data
1. While on the Data file page, swipe
the file to the left. Share and Delete
icon will be shown.
2. Click the “Share” icon, and can share on the
available apps.
FOR ANDROID VERSION ONLY
• To view the data
1. Click the “data file” on the top right corner of the interface.
2. Click the “file name” to check the data.
3. Can be viewed as
Curve data or List data.
• To export the data
1. While on the “record file”, click the dropdown button and select “Export”.
2. Choose to export via PDF or Excel file.
3. Click “Confirm” to download the file. The downloaded file will be stored
in the "dB_Tester" folder located in the /storage/emulated/0/
The meter is powered by 3 pcs of AAA 1.5V Batteries.
Replace the batteries when:
• The low battery signal icon will appear on LCD.
• The meter cannot be powered on.
To install the batteries:
1. Turn off the meter and remove the battery cover.
2. Replace the old batteries with 3 new AAA 1.5V batteries.
3. Put back the battery cover.
1. If the device will not be used for a long period of time, remove the
battery to prevent damage to the device due to battery leakage.
2. To prevent damage or severe deterioration to the device, do not open
the inside of the device or modify its circuitry.
3. Do not place the device in a humid, dusty, acidic, alkaline or corrosive
environment to avoid damage to the device.
4. Use a clean, soft cloth to wipe the meter if it becomes dirty.
Measuring Range
Accuracy
Frequency Response
Frequency Weighting
Resolution
Working Temperature and Humidity
Storage Temperature and Humidity
Power Source
Weight
External Dimension
Data Storage
Auto power off
30 ~ 130dBA
±1.5dB
31.5Hz ~ 8KHz
A Weighting
0.1dB
0 ~ 40°C, 10 ~ 80%RH
-10 ~ 60°C, 0 ~ 90%RH
3*1.5V AAA Batteries
96.38g (Excluding Battery)
56.1 x 177 x 36.03 mm
20000 groups
10 minutes without operation
BATTERY REPLACEMENT
VIEWING & SHARING SAVED DATA
Install three 1.5V AAA batteries
Curve Data
Click the dropdown button
to choose between Curve
and List data view.
List Data
Save or share the file through the
application on the Share Sheet.
1
2
3
Swipe to the left
1 2
IOS version Android version
IOS version Android version
IOS version Android version
CALIBRATION METHOD
To calibrate the meter, an external sound level calibrator that can provide a
94.0dB signal at 1kHz and a small flat screw-driver are required. Follow the steps
below to calibrate the instrument.
Data file
Data file
Menu Menu
IOS version Android version
IOS version Android version
downloaded files location

Popular Measuring Instrument manuals by other brands

Omntec Proteus Series System programming manual

Omntec

Omntec Proteus Series System programming manual

Kaiweets HT200B user manual

Kaiweets

Kaiweets HT200B user manual

LDS Dactron PHOTON+ System guide

LDS

LDS Dactron PHOTON+ System guide

IFM Electronic Efector 300 operating instructions

IFM Electronic

IFM Electronic Efector 300 operating instructions

Thermo Scientific Applied Biosystems SeqStudio Genetic... Getting started guide

Thermo Scientific

Thermo Scientific Applied Biosystems SeqStudio Genetic... Getting started guide

FuturePlus Systems FS2334 user manual

FuturePlus Systems

FuturePlus Systems FS2334 user manual

Spectrum Technologies 6490S product manual

Spectrum Technologies

Spectrum Technologies 6490S product manual

Quantum Composers Jewel Laser operating manual

Quantum Composers

Quantum Composers Jewel Laser operating manual

dacell DN-711A instruction manual

dacell

dacell DN-711A instruction manual

fann 415C instruction manual

fann

fann 415C instruction manual

Huvitz HNT-1 user manual

Huvitz

Huvitz HNT-1 user manual

Crowcon APM 145 operating instructions

Crowcon

Crowcon APM 145 operating instructions

Fluke i200 instruction sheet

Fluke

Fluke i200 instruction sheet

Netech DigiMano 2000 instruction manual

Netech

Netech DigiMano 2000 instruction manual

Crosslinking DR 020 operating manual

Crosslinking

Crosslinking DR 020 operating manual

ATAGO PAL-121S manual

ATAGO

ATAGO PAL-121S manual

Wohler DC 410FLOW user manual

Wohler

Wohler DC 410FLOW user manual

Dr. A. Kuntze Neon pR manual

Dr. A. Kuntze

Dr. A. Kuntze Neon pR manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.