Dante DLH4200B User manual

DLH4200B
Matrix Switcher
Installation and Operations Manual
Model Number: DLH4200B
Description: Enclosure Style
Matri Video Switcher

TABLE OF CONTENTS
IMPORTANT SAFEGUARDS AND WARNINGS ...........................................................5
DESCRIPTION...................................................................................................6
MODELS ..........................................................................................................9
INSTALLATION................................................................................................ 10
MOUNTING .............................................................................................10
AUDIO VIDEO SOURCES .........................................................................11
CONTROL LINES ......................................................................................13
MONITORS..............................................................................................14
CONNECTING A SINGLE RELAY INTERFACE UNIT......................................15
ALARMS ..................................................................................................16
CONNECTING DEVICES THROUGH THE COMMUNICATION PORTS ..............17
KEYBOARDS ............................................................................................20
SYSTEM START-UP .......................................................................................... 21
POWER-UP THE SYSTEM ..........................................................................21
INITIALIZE KEYBOARDS..........................................................................21
CONFIGURE THE SYSTEM.........................................................................22
Time and date ................................................................................ 22
Camera titles.................................................................................. 22
Monitor titles .................................................................................. 22
PTZ............................................................................................... 22
ALARM .......................................................................................... 22
PORT............................................................................................. 22
PROGRAMMING THE DLH4200B SERIES .............................................................. 23
PROGRAMMING FROM THE KEYBOARDS ...................................................24
DLH4200B SERIES PROGRAMMING MODE ................................................25
EXIT PROGRAMMING MODE .....................................................................26
NAVIGATE AND SELECT OPTIONS FIELD ENTRIES IN PROGRAMMING MODE
..............................................................................................................26
CAMERA PROGRAMMING .........................................................................27
PORT PROGRAMMING..............................................................................30
MONITOR PROGRAMMING .......................................................................32
PRIORITY ...............................................................................................33
ALARM ....................................................................................................34
ACCESS...................................................................................................36
SEQUENCE ..............................................................................................37
DISPLAY .................................................................................................38
TIME & DATE .................................................................................................. 39
PASSWORD .............................................................................................40
SYSTEM ..................................................................................................41
ETHERNET...............................................................................................42

WATCH ...................................................................................................43
ABOUT ....................................................................................................44
OPERATING THE DLH4200B SERIES ................................................................... 45
◆
◆◆
◆ INSTALL THE DLH4200B SERIES ..........................................................45
◆
◆◆
◆ SWITCH MONITORS.............................................................................45
◆
◆◆
◆ SELECT CAMERAS ................................................................................45
◆
◆◆
◆ SELECT Audio Input .............................................................................45
◆
◆◆
◆ CREATE AND RUN A PRESET .................................................................45
◇Create a Preset ............................................................................ 45
◇Run a Preset................................................................................ 45
◆
◆◆
◆ PTZ CONTROL......................................................................................46
◆
◆◆
◆ CREATE AND RUN A PATTERN ..............................................................46
◇ Create a Pattern .......................................................................... 46
◇Run a Pattern............................................................................... 46
◆
◆◆
◆ OPERATE AUXILIARIES RELAYS ..........................................................47
◆
◆◆
◆ OPERATE SEQUENCES ..........................................................................48
◆
◆◆
◆ ACKNOWLEDGE AN ALARM...................................................................50
◆
◆◆
◆ KEYBOARD OFF LINE ...........................................................................51
MATRIX NETWORK SYSTEM............................................................................... 52
LINK METHOD ................................................................................ 52
SYSTEM SETTING ....................................................................................53
APPENDIX A ................................................................................................... 55
2000 SERIES MATRIX IS THE SATELLITE MATRIX OF THE PELCO SYSTEM
MATRIX TO CONNECT THE SETUP.............................................................55
LINK METHOD .........................................................................................55
SYSTEM SETTING ....................................................................................56
DLH4200B SERIES matri parameter setup ......................................... 56
CM97XX matri parameter setup ....................................................... 57
CONNECTING DEVICES THROUGH THE COMMUNICATION PORTS ..............61
DLH4200B SERIES Matri RJ45 Communication Port Inputs .................... 61
PELCO-CM97XX-CC1 RJ45 Communication Port Inputs........................... 62
APPENDIX B ................................................................................................... 63
CONNECTING MV96e MULTIPLEXERS .......................................................63
LINK METHOD ................................................................................ 63
SETTING THE MUTEX COMMUNICATE PORT.......................................... 63
OPERATING THE MV96e.................................................................... 64
APPENDIX C ................................................................................................... 65
The Ethernet Communication Module .......................................................65
1. IP address setup in Matri ............................................................. 65
2. WEB Browser .............................................................................. 66
3. DEVICE MANAGEMENT SOFTWARE ................................................. 71
4. Data Station Monitor .................................................................... 72
5. Matri Networking Control........................................................... 733

Updated version of Manual with Manchester Control code………………..….74
Manchester Code Communication……………………………………………………………………………………..75
Control Description…………………………………………………………………..………………………………………..76
APPENDIX D ................................................................................................... 74
DLH4200B SERIES DIP SWITCHES ...........................................................76
TROUBLESHOOTING ................................................................................76
GAINING INITIAL CONTROL .............................................................. 77
SOFTWARE RESET........................................................................... 77
ASCII CHARACTER........................................................................................... 77
SPECIFICATIONS.............................................................................................79
GENERAL ................................................................................................79
ELECTRICAL ............................................................................................79
AUDIO VIDEO.........................................................................................79
MECHANICAL ..........................................................................................79

IMPORTANT SAFEGUARDS AND WARNINGS
1. Read, keep, and follow these instructions.
2. Heed all warnings.
3. There are no user-serviceable parts inside this unit. Only authorized service
personnel may open the unit.
4. Installation and servicing should only be done by qualified service personnel
and conform to all local codes.
5. WARNING: To reduce the risk of fire or electric shock, do not e pose this
unit to rain or moisture if this unit is designed for indoor use only.
6. Unless this unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6 or
6P enclosure, it is designed for indoor use only and it must not be installed
where e posed to rain or moisture.
7. Do not e pose this unit to dripping or splashing. Do not place objects filled
with liquids, such as vases, on this unit.
8. Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
9. The installation method and materials should be capable of supporting four
times the weight of the unit and equipment.
10. Do not install near any heat source.
11. Only use attachments/accessories specified by the manufacturer.
12. Clean only with dry cloth.
13. Do not defeat the safety purpose of the polarized or grounding-type plug.
14. Protect the power cord from being walked on or pinched, particularly at
plugs, convenience receptacles, and the point where they e it from the unit.
15. Unplug this unit during lightning storms or when unused for long periods of
time.
The product and or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of
electric shock is present within unit.
This symbol indicates that there are important operating and
maintenance instructions in the literature accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual
prior to installation and operation.
FOR QUALIFIED SERVICE PERSONNEL ONLY
1. Only use replacement parts recommended by the manufacturer.
2. After replacement/repair of this unit’s electrical components, conduct a
resistance measurement between line and e posed parts to verify the
e posed parts have not been connected to line circuitry.
3. CAUTION: Danger of e plosion if battery is incorrectly replaced.
Replace only with the same or equivalent type.
Battery should only be replaced by authorized service personnel.

6
DESCRIPTION
DLH4200B SERIES Matri Switcher/Controller is a cross-point Audio/video
matri switcher. The DLH4200B SERIES provides switching and control for 48
Audio/video inputs and 16 Audio/video outputs from any one of up to 16
keyboards, and other devices.
The DLH4200B SERIES features easy programming through on-screen menus. All
programming is password-protected.
Figure 1. Sample DLH4200B SERIES System
DLS1125 Camera
DLS1972 PTZ Dome
DLS1972 PTZ Dome
DLH4200B48x16A Switcher
DLH6220 Monitors
DLH6630 Alarm Relay
DLH63300 Keyboards
DLH6620 Alarm Interface

7
Keyboards
Up to 16 keyboards can be connected to the DLH4200B SERIES. Camera
positioning can be programmed and controlled from keyboards. Refer to
Associated Equipment for keyboard descriptions.
Sequences, Presets, Patterns,
All programming is password-protected.
A preset allows operators to direct a PTZ (camera positioning system) to move to
a predetermined scene on keyboard command or as a result of an alarm. In
addition, a preset can place a descriptive title on the monitor screen. The number
of presets available is determined by the camera positioning system.
With a pattern operators can program a camera positioning system to move around
its viewing area in a repeating pattern. The number and length of patterns varies
with different positioning systems.
System Access and Priority
The DLH4200B SERIES provides eight levels of priority control. Each level defines
the ability of a keyboard to control a camera positioning system and to access
programming screens.
NOTE: PTZ is a camera positioning system with pan, tilt, and zoom capabilities.

8
Alarm Inputs
Eight internal alarm inputs are provided on the rear panel of the matri
switcher/controller. These internal alarm inputs are programmable to associate
any camera to any input. A DLH4200B SERIES system provides 8 internal alarm
inputs and 128 e ternal alarm inputs.
Auxiliary Outputs
Two internal au iliary outputs are provided on the back of the DLH4200B SERIES.
They are relay outputs,
You can connect up to two Relay Interface Units to the DLH4200B SERIES.
Power, Mounting Methods
The DLH4200B SERIES operates on 120VAC (NTSC) 60Hz or 230VAC (PAL) 50Hz.
The case mounts in 4U of vertical space in a universal mount, or to a wall or
tabletop.
Continuous Operating Device
The DLH4200B SERIES is a self-contained audio/video surveillance system
designed for continuous duty operation. Once installed, no user or service
technician items require the power to be turned off under normal operation.
Direct menu control and indirect control, the communication ports use standard
low voltage interfaces (RS-232, RS-422 and RS-485), and all connections and
disconnections do not require rebooting or power cycling. Audio/Video connections
or changes of termination state do not require rebooting or power cycling.

9
MODELS
DLH4200B SERIES Matri switcher/controller with up to 48 audio/video
inputs and 16 audio/video outputs, 120VAC; 230VAC,
50/60Hz。
ASSOCIATED EQUIPMENT
DLH6330 Desktop keyboard, with full switching and programming
capabilities, 12VDC or 12VAC 50/60 Hz.
DLH6620 Alarm interface unit, provides alarm monitoring capabilities
for up to 64 alarm inputs, 100-240 VAC, 50/60 Hz
DLH6630 Relay interface unit, provides 64 relays for operating
peripheral equipment, 100-240 VAC, 50/60 Hz
DLH6300 Wiring kit for connecting keyboards to remote keyboard port;
includes two port and a transformer for keyboard power.

10
INSTALLATION
NOTE: There are no user-serviceable parts inside this unit. Only authorized
service personnel may open the unit.
Unpack and inspect all parts carefully. The following parts are supplied:
1 DLH4200B SERIES Switcher/Controller
2. Power cord
3. 5m straight data cables with RJ-45 connectors.
MOUNTING
1 Select a suitable location for the DLH4200B SERIES. Mount the DLH4200B
SERIES in a standard equipment rack. Follow proper installation practices
and leave 1 RU above and below the DLH4200B SERIES for ventilation. Do
not connect the power until the installation is complete. Refer to the System
Start-Up section.
2. The DLH4200B SERIES is shipped with the rack ears installed at the front.
Reposition or remove ears as needed for your application.
3. Use supplied pan head screws and washers to mount the DLH4200B SERIES
in a standard equipment rack or wood or sheet metal screws to mount against
a flat surface, according to your installation requirements.
Figure 2. Mounting the DLH4200B SERIES Matri Switcher/Controller

11
AUDIO VIDEO SOURCES
NOTE: The end point of any video cable run must be terminated in 75 ohms.
The DLH4200B SERIES offers 48 full-function audio/video inputs which support PTZ
control and video loss detection. The video inputs can be used for looping video
connections with terminating and unterminated connectors on the back panel.
Figure 3. DLH4200B SERIES Audio/Video Inputs
1. Connect video cables at the appropriate video input BNC receptacles on the
back of the DLH4200B SERIES. For best results, use crimp-on BNC’s only. Do
not uses screw-on BNC’s; these typically do not provide adequate ground and
signal connections.
Refer to Table A for video coa ial wiring requirements.
Table A. Video Coa ial Cable Requirements
Cable Type* Maximum Distance
RG59/U
RG6/U
RG11/U
750ft(229m)
1000ft(305m)
1500ft(457m)
* Minimum cable requirements:
75 ohms impedance
All-copper center conductor
All-copper braided shield with 95% braid coverage

12
2. Set the Video Inputs according to your system requirements.
Figure 4. Connecting Terminated Video Sources
Figure 4A. Connecting Looping Video Sources

13
CONTROL LINES
NOTE: D and P protocol receivers cannot be mi ed on the same communication
port.
Connect camera control lines to receivers. If any of your video sources are using D
or P protocol via RS-422 communications, they will connect at the PTZ connectors
on the back of the DLH4200B SERIES.
NOTE: After completing system installation and power-up, you must configure
the DLH4200B SERIES and the camera/receiver. Refer to the System
Start-Up section.
Figure 5. PTZ Control Connections
DLS1971

14
MONITORS
The DLH4200B SERIES supports 16 monitors.
1. Install monitors according to the instructions provided with them.
2. Connect the monitor cables at the appropriate video output BNC receptacles
on the back of the DLH4200B SERIES.
Figure 6. Connecting Monitors

15
CONNECTING A SINGLE RELAY INTERFACE UNIT
To connect a single Relay Interface Unit:
1. Connect the Relay OUT port to COM 3 (Default Port) on the DLH4200B SERIES
using the 5m straight data cable supplied with the DLH4200B SERIES.
2. Set SW2, DIP switches 1-8 to the appropriate positions for the local address
(default address setting is 1). Refer to the Relay Interface Unit
Installation/Operation Manual for instructions.
Figure 7. Connecting Relays
DLH6630
DLH4200B Switcher

16
ALARMS
The DLH4200B SERIES provides numerous alarm handling options. Refer to the
Programming section for a detailed description.
1. Connect wires from the sensors to the respective alarm input points on the
connectors at the back of theDLH4200B SERIES. Each sensor requires two
wires – one wire to the alarm input terminal and a return wire to one of the
ground terminals on the connector. The DLH4200B SERIES supports eight
internal alarms.
Alarm sensors can be either N.O. (normally open) or N.C. (normally closed)
contacts. The DLH4200B SERIES is set to N.O. as a factory default.
2. If your system requires more than eight alarms, connect an Alarm
Interface unit model DLH6620 to the system.
Figure 8. Connecting Alarms
DLH6620 DLH6620
DLH4200B

17
CONNECTING DEVICES THROUGH THE COMMUNICATION PORTS
The DLH4200B SERIES Matri Switcher/Controller provides 10 communication
ports on the rear panel for connecting peripheral components. Instructions are
provided in this section for the most commonly used connections.
Figure 9. Communication Port Inputs
DLH4200B
8 RJ
-
45

18
Table A. Communication Port Devices and Wiring
Port Input
Type Wiring Pin-Outs Default Device
1 DB9
RJ-45 RS-232
2 R
3 T
5 Ground
ASCII device
2 RJ-45 RS-232
1 R
5 Ground
8 T
CCU
3 RJ-45 RS-485
1 R +
2 R -
5 Ground
7 T -
8 T +
Au iliary Outputs
4 RJ-45 RS-485
1 R +
2 R -
5 Ground
7 T -
8 T +
Alarm inputs
5&6 RJ-45 RS-485
1 R +
2 R -
3 KBD power
(12V)
4 KBD Ground
5 Ground
7 T -
8 T +
Keyboard
DLH6330
(direct powered)
7 RJ-45 RS-485
RS-485 Pin-Outs:
1 R +
2 R -
5 Ground
7 T -
8 T +
MAXPRO
8 RJ-45 RS-485
RS-485 Pin-Outs:
1 R +
2 R -
5 Ground
7 T -
8 T +
PTZ-port
9 DIP RS-485 PTZ-A
10 DIP RS-485
1 T +
2 T -
3 Ground
4 Ground
5 R +
6 R -
PTZ-B

19
Table B. Default Port Settings
Port Default Settings
1 RS-232, 9600 baud, NO parity, 8 data bits, 1 stop bit
2 RS-232, 9600 baud, NO parity, 8 data bits, 1 stop bit
3 RS-485, 9600 baud, EVEN parity, 8 data bits, 1 stop bit
4 RS-485, 4800 baud, EVEN parity, 8 data bits, 1 stop bit
5,6 DLH6330, 9600 baud, EVEN parity ,8 data bits, 1 stop bit
7 DLH4300, 9600 baud, EVEN parity, 8 data bits, 1 stop bit
8 RS-485, 9600 baud, NO parity, 8 data bits, 1 stop bit
PTZ-A 、
PTZ-B RS-422, 9600 baud, NO parity, 8 data bits, 1 stop bit
NOTE: Refer to the Programming section for instructions on changing Port settings

20
KEYBOARDS
You can connect up to 8 remotely connected keyboards to any of the following
ports:
• COM 5 (1 direct-powered keyboard or up to 8 remotely connected
keyboards)
• COM 6 (1 direct-powered keyboard or up to 8 remotely connected
keyboards)
The total number of keyboards connected to the DLH4200B SERIES cannot e ceed
16.
NOTE: When you connect more than one keyboard to one port. You must set the
keyboard DIP switches for the desired address for the local keyboard
If you are connecting more than one keyboard to COM 5 or 6, a DLH6301 (120VAC)
or DLH6302 (230VAC) is required for each keyboard.
1. Using the 5m straight data cable supplied with the keyboard, plug one end
into the RJ-45 connector on the rear of the keyboard.
2. Plug the other end of the data cable into either COM 5 or 6 on the
DLH4200B SERIES.
3. Set the keyboard DIP switches for the desired address for the local keyboard
Refer to the keyboards Operation Manual for instructions.
Figure 10. Data Cable Plugged into Local Keyboard
DLH6330
Table of contents
Other Dante Matrix Switcher manuals
Popular Matrix Switcher manuals by other brands

Extron electronics
Extron electronics CrossPoint 450 Plus 64 Series user manual

Accell
Accell UltraAV user guide

Rose electronics
Rose electronics EE2-2X16U/E Installation and operation manual

SENSORVISION PRODUCTS
SENSORVISION PRODUCTS VM32 installation instructions

resi-linx
resi-linx RL-BV1000 installation manual

AMX
AMX AVS-OCT-3264-367 Product View