Datalogic SG-M User manual

Other Datalogic Rack & Stand manuals

Datalogic BASIC HOLDER Technical manual

Datalogic

Datalogic BASIC HOLDER Technical manual

Datalogic 94ACC0175 User manual

Datalogic

Datalogic 94ACC0175 User manual

Datalogic JoyaTouch Owner's manual

Datalogic

Datalogic JoyaTouch Owner's manual

Datalogic VMK-8000 User manual

Datalogic

Datalogic VMK-8000 User manual

Datalogic VMK-P096 User manual

Datalogic

Datalogic VMK-P096 User manual

Popular Rack & Stand manuals by other brands

Salamander Acadia AC/W/L400/WH Assembly instructions

Salamander

Salamander Acadia AC/W/L400/WH Assembly instructions

Fohhn VAT-09 Mounting instruction

Fohhn

Fohhn VAT-09 Mounting instruction

ricoo FS0522 quick start guide

ricoo

ricoo FS0522 quick start guide

AMSOIL BMK-22 Installation and service instructions

AMSOIL

AMSOIL BMK-22 Installation and service instructions

Kargo Master 48220 installation guide

Kargo Master

Kargo Master 48220 installation guide

Milestone AV Technologies SIMPLICITY SLF2 installation instructions

Milestone AV Technologies

Milestone AV Technologies SIMPLICITY SLF2 installation instructions

ricoo S1222 installation instructions

ricoo

ricoo S1222 installation instructions

Ready-Set-Mount RSMCM602 instruction manual

Ready-Set-Mount

Ready-Set-Mount RSMCM602 instruction manual

VidaBox VB MNT FFS2 installation guide

VidaBox

VidaBox VB MNT FFS2 installation guide

Welch Allyn 48960 Assembly instructions

Welch Allyn

Welch Allyn 48960 Assembly instructions

Arkon CM035-ST-2 installation instructions

Arkon

Arkon CM035-ST-2 installation instructions

PROEL PLWIN60C user manual

PROEL

PROEL PLWIN60C user manual

Agilent Technologies E2609B installation guide

Agilent Technologies

Agilent Technologies E2609B installation guide

Mustang MV-ARM4 installation guide

Mustang

Mustang MV-ARM4 installation guide

Mounting Solutions WRM-320 manual

Mounting Solutions

Mounting Solutions WRM-320 manual

ShelterIt 21208 installation instructions

ShelterIt

ShelterIt 21208 installation instructions

Pyle PMKSPAD1 manual

Pyle

Pyle PMKSPAD1 manual

SPL RackPack?4 1040 manual 

SPL

SPL RackPack?4 1040 manual 

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

SG-M
INSTRUCTION MANUAL
System is compatible with all Datalogic SG safety light curtains with muting function feature.
For correct use and safety prescriptions refer to the user manual of Datalogic safety light curtains where
muting kit is installed.
With modular muting systems it is possible to arrange multiple configurations.
MODEL DESCRIPTION ORDER NUMBER
SG-ML-S8-L Kit for L Muting, left side: 2 sensors S8-PR-3-B01-PP with a 0.7m
cable with M12 connector; 2 reflectors; 1 active arm; 1 passive
arm; 2 cable-lockers 95ASE2600
SG-ML-S8-R Kit for L Muting, right side: 2 sensors S8-PR-3-B01-PP with a
0.7m cable with M12 connector; 2 reflectors; 1 active arm; 1
passive arm; 2 cable-lockers 95ASE2370
SG-ML-S8-200-L Kit for L Muting, left side: 2 sensors S8-PR-3-B01-PP with a 2m
cable with M12 connector; 2 reflectors; 1 active arm; 1 passive
arm; 2 cable-lockers 95ASE2590
SG-ML-S8-200-R Kit for L Muting, right side: 2 sensors S8-PR-3-B01-PP with a 2m
cable with M12 connector; 2 reflectors; 1 active arm; 1 passive
arm; 2 cable-lockers 95ASE2340
SG-ML-S100-L Kit for L Muting, left side: 2 sensors S100-PR-5-B10-PK;
2 reflectors; 1 active arm; 1 passive arm; 2 cable-lockers;
2x 700mm cables with M12 connectors 95ASE2620
SG-ML-S100-R Kit for L Muting, right side: 2 sensors S100-PR-5-B10-PK;
2 reflectors; 1 active arm; 1 passive arm; 2 cable-lockers;
2x 700mm cables with M12 connectors 95ASE2430
SG-ML-S100-200-L Kit for L Muting, left side: 2 sensors S100-PR-5-B10-PK;
2 reflectors; 1 active arm; 1 passive arm; 2 cable-lockers;
2 x 2000mm cables with M12 connectors 95ASE2610
SG-ML-S100-200-R Kit for L Muting, right side: 2 sensors S100-PR-5-B10-PK;
2 reflectors; 1 active arm; 1 passive arm; 2 cable-lockers;
2 x 2000mm cables with M12 connectors 95ASE2400
MODEL DESCRIPTION ORDER NUMBER
SG-MT-S8 Kit for T Muting: 4 sensors S8-PR-3-B01-PP with a 0.7m cable
with M12 connector; 4 reflectors; 2 active arms; 2 passive arms; 4
cable-lockers 95ASE2380
SG-MT-S8-200 Kit for T Muting: 4 sensors S8-PR-3-B01-PP with a 2m cable with
M12 connector; 4 reflectors; 2 active arms; 2 passive arms; 4
cable-lockers 95ASE2350
SG-MT-S100 Kit for T Muting: 4 sensors S100-PR-5-B10-PK;
4 reflectors; 2 active arms; 2 passive arms; 4 cable-lockers;
4 x 700mm cables with M12 connectors 95ASE2440
SG-MT-S100-200 Kit for T Muting: 4 sensors S100-PR-5-B10-PK;
4 reflectors; 2 active arms; 2 passive arms; 4 cable-lockers;
4 x 2000mm cables with M12 connectors 95ASE2410
MODEL DESCRIPTION ORDER NUMBER
SG-MX-S8 Kit for X Muting; 2 sensors S8-PR-3-B01-PP with a 0.7m cable
with M12 connector; 2 reflectors; 2 active arms; 2 passive arms; 4
cable-lockers 95ASE2390
SG-MX-S8-200 Kit for X Muting; 2 sensors S8-PR-3-B01-PP with 2m cable with
M12 connector; 2 reflectors; 2 active arms; 2 passive arms; 4
cable-lockers 95ASE2360
SG-MX-S100 Kit for X Muting; 2 sensors S100-PR-5-B10-PK;
2 reflectors; 2 active arms; 2 passive arms; 4 cable-lockers;
700mm pigtail cables with M12 connectors 95ASE2450
SG-MX-S100-200 Kit for X Muting; 2 sensors S100-PR-5-B10-PK;
2 reflectors; 2 active arms; 2 passive arms; 4 cable-lockers;
2000mm pigtail cables with M12 connectors 95ASE2420
MOUNTING
Put the arm slider (1) into the column slot (2).
Fix the arm (3) in the desired position by screws (4), 1 Nm recommended tightening torque.
Rotate sensors/reflectors support (5) in the desired position ; if necessary, translate support removing
and spacing cable-locker (6) and fix by screws (7), 2 - 3 Nm recommended tightening torque.
Loosen the two screws (8) and rotate/set the sensor/reflector as desired, then fix by screws (8),
1Nm recommended tightening torque.
NOTE:
For It is recommended to use the Datalogic SG-M-CB connection box for electrical connections of the
SG-M kit to the Datalogic safety curtains.
For each muting system kit it is recommended to use the same sensors type kit.
Sensors must be set on Dark Mode.
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com: Contact Us, Terms and Conditions, Support.
The warranty period for this product is 36 months. See General Terms and Conditions of Sales for further details.
Under current Italian and European laws, Datalogic is not obliged to take care of product disposal at the end of its life. Datalogic
recommends disposing of the product in compliance with local laws or contacting authorised waste collection centres.
© 2015 - 2017 Datalogic S.p.A. and/or its affiliates ALL RIGHTS RESERVED. Without limiting the rights under copyright, no part of this
documentation may be reproduced, stored in or introduced into a retrieval system, or transmitted in any form or by any means, or for any
purpose, without the express written permission of Datalogic S.p.A. and/or its affiliates. Datalogic and the Datalogic logo are registered
trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other trademarks and brands are property of their
respective owners. Datalogic reserves the right to make modifications and improvements without prior notification.
821003472 Rev.B
“R”
“L”
L-MUTING
T-MUTING
X-MUTING
SG-M-CB
CONNECTION BOX
ISTRUCTION MANUAL
GENERAL INFORMATION
The SG-M-CB Connection Box is part of SG-M
accessories for muting, to be used with DATALOGIC
safety light curtains of SG series, with integrated muting
function (i.e. SG BODY REFLECTOR MUTING).
Muting sensors can be connected to SG-M-CB
Connection box via M12 cables.
The signals are connected to Safety light curtain
dedicated muting connector via approx. 0.5m long pigtail
cable with M12 female connector.
Aside from the green LEDs* (to indicate sensors output
status), the SG-M-CB does not contain any electronic
elements and is therefore not subject to any safety
classification.
Features:
Supply and switching voltage +24V DC
M12 connection
Simple connection to safety light curtains.
* For correct operation of LED indicators, it is mandatory to connect
identical sensors to the four M12 sockets.
TECHNICAL DATA
Power supply &
Switching voltage: +24 VDC ±20%
Current load max.: 1 A
Insulating resistance: >1009 Ω
Mechanical protection: IP 65
Operating temperature: -10°C....+55°C
Storage Temperature: -25°C....+70°C
Housing material: PVC, Black (UL Recognized)
Housing Cable (C2): PVC, Black (UL Recognized)
Housing Connector (C1): Plug M12-5P A-Coding Female
Housing Connectors
(A1;A2;B1;B2): Sockets M12-5P A-Coding Female
Pin assignment:
PIN C1 A1 A2 B1 B2
1 24V 24V 24V 24V 24V
2 MUT2 - - - -
3 0 V 0 V 0 V 0 V 0 V
4 MUT 1 MUT 1 MUT 1 MUT 2 MUT 2
5 - - - - -
ORDER GUIDE
Model Description Order number
SG-M-CB CONNECTION BOX 95ASE2500
SG-M-CB-KIT MOUNT. KIT 95ASE2830
For each muting system kit is recommended to use same
sensors type.
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com: Contact Us, Terms and Conditions, Support.
The warranty period for this product is 36 months. See General Terms and Conditions of Sales
for further details.
Under current Italian and European laws, Datalogic is not obliged to take care of product
disposal at the end of its life. Datalogic recommends disposing of the product in
compliance with local laws or contacting authorised waste collection centres.
© 2015 - 2017 Datalogic S.p.A. and/or its affiliates ALL RIGHTS RESERVED. Without
limiting the rights under copyright, no part of this documentation may be reproduced, stored in
or introduced into a retrieval system, or transmitted in any form or by any means, or for any
purpose, without the express written permission of Datalogic S.p.A. and/or its affiliates.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries,
including the U.S.A. and the E.U. All other trademarks and brands are property of their respective
owners. Datalogic reserves the right to make modifications and improvements without prior
notification.
821003681 Rev. A
DIMENSIONS
dimensions in mm
C1