Double output
power supply unit
DAT 411
DAT 411
GENERAL DESCRIPTION
T e power supply unit DAT 411 is designed to provide two not regulated isolated outputs to power t e DATEXEL devices like transmitters and
low current consumption converters.
In function of t e version, t e device can accept t ree input voltage values:24, 120 or 230 Vac.
T e DAT 411 is in compliance wit t e Directive 2004/108/EC on t e Electromagnetic Compatibility.
It is oused in a plastic enclosure of 28 mm t ickness suitable for DIN rail mounting in compliance wit EN-50022 and EN-50035 standards.
FEATURES
AC line input: 24, 120 or 230 Vac @ 50 60 Hz
Two isolated outputs
Power supply unit for transmitters
EMC compliant – CE mark
In compliance with the safety standard
Suitable for DIN rail mounting in compliance with EN 50022 and EN 50035
USER INSTRUCTIONS
T e DAT 411 must be connected as follows:
T e input connections must be made as s own in t e section "Input connections".
T e input voltage ( AC line ) must be applied between t e terminals G ( IN AC) and H ( IN AC ).
T e output connections must be made as s own in t e sections “Output 1 & 2 connections”
T e output signal Out 1 is provided between t e terminals F (+Vout1) and E (GND1), T e output signal Out 2 is provided between t e
terminals D (+Vout2) and C (GND2).
To install t e transmitter refer to section “Installation Instructions”.
TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions)
Input
Input voltage 24 Vac ± 10 % @ 50-60 Hz.
120 Vac ± 10 % @ 50-60 Hz.
230 Vac ± 10 % @ 50-60 Hz.
Outputs
Output 1 (Out 1) 20 Vdc @ 25 mA not regulated for Rload = 250 o m
Output 2 (Out 2) 20 Vdc @ 25 mA not regulated for Rload = 250 o m
Load resistance (Rload) see section “Load c aracteristic”
Environmental data
Safety EN 61010-1
Electromagnetic Compatibility (EMC)
( for industrial environments ) Immunity: EN 61000-6-2; Emission : EN 61000-6-4.
Operating Temperature -20 ÷ 60 °C
Storage Temperature -40 ÷ 85 °C
Humidity (not condensed) 0 ÷ 90%
Weig t about 130 g