Before connecting the pump to the mains power supply, check the Voltage, Amps and
frequency corresponds with the motor nameplate rating. Single phase pumps under 10Amps
can be connected directly to an electrical outlet, all other models must be connected to a
switch or suitable control box such as Simplex. Pump must be earthed to a suitable ground
connection in accordance with all national codes prior to any other connections.
Ensure all cables and leads are protected from damage, if possible tapped to pipework or
inside conduit to prevent snagging. Protect all connections and plugs from water.
Single phase pumps have auto re-set internal thermal overload protection and a capacitor.
Caution: The pump will stop from overload tripping but will automatically restart once the
motor has cooled suiciently for overload to reset.
Three Phase pumps must be installed with overload protection supplied by the user and set
around 510% above full load Amp rating.
Lightening, surge and overcurrent protection must be provided by the user. Running pumps
o extension cords is not recommended.
Impeller rotation must be clockwise when viewed from the top on three phase pumps. This
can reversed by swapping any two of the supply wires. Running backwards can damage the
pump and void warranty.
Single phase power supply is 230v +-10%, 50Hz.
Three phase power supply is 415v +-10%, 50Hz.
Maintenance
Maintenance must only be done by qualiied and authorised people. Ensure mains power
is disconnected from pump before doing any servicing or maintenance. Pump may be hot
after use, allow to cool down before handling.
The UV series pumps require regular visual inspection to check for any leaks in the system,
control obstructions, vibrations or noises. If anything is detected this must be recorded and
remedied as soon as possible.
The motors and bearings are sealed and no lubrication is required.
The shaft lip seal and mechanical seal oil bath should be inspected for wear annually in light
duty or quarterly in heavy duty applications. For replacement parts please contact your
supplier. Failure to monitor and maintain seal condition or damage to motor caused by seal
failure may not be covered by the warranty.
Single phase motors have a run capacitor which may cause overload tripping or unusual
noises if this is falling, replace as required.
If pump or pipework is getting jammed or blocked regularly, the sump may require cleaning
or change system to reduce the amount and size of solids entering.