EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Dawson
  6. •
  7. Media Converter
  8. •
  9. Dawson DZA50 User manual

Dawson DZA50 User manual

Popular Media Converter manuals by other brands

SoundTraxx Blunami BLU-2200 user guide

SoundTraxx

SoundTraxx Blunami BLU-2200 user guide

SPROLINK VA1 user manual

SPROLINK

SPROLINK VA1 user manual

Acclaim Lighting DDC-1-AC user guide

Acclaim Lighting

Acclaim Lighting DDC-1-AC user guide

Nikon AF-S TC-20E III user manual

Nikon

Nikon AF-S TC-20E III user manual

Axis AXIS Q7406 user manual

Axis

Axis AXIS Q7406 user manual

Omega TAC80B-J instruction sheet

Omega

Omega TAC80B-J instruction sheet

Zoom Thunderbolt TAC-2R Operation manual

Zoom

Zoom Thunderbolt TAC-2R Operation manual

OST iConverter 10/100M quick start guide

OST

OST iConverter 10/100M quick start guide

Vertiv Netsure user manual

Vertiv

Vertiv Netsure user manual

birddog MINI user guide

birddog

birddog MINI user guide

Roland GI-10 owner's manual

Roland

Roland GI-10 owner's manual

Wallenstein WX310 Operator's manual

Wallenstein

Wallenstein WX310 Operator's manual

Pace MSS 200-1 Service manual

Pace

Pace MSS 200-1 Service manual

Solar Converters EQ 12/24-50 manual

Solar Converters

Solar Converters EQ 12/24-50 manual

CYP EL-7400V Operation manual

CYP

CYP EL-7400V Operation manual

TIE MIDI 1i1o user manual

TIE

TIE MIDI 1i1o user manual

DCS Vivaldi Upsampler user manual

DCS

DCS Vivaldi Upsampler user manual

Westermo MCW-211 SERIES user guide

Westermo

Westermo MCW-211 SERIES user guide

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

DZA50
USER’S MANUAL
AC LINE SPLITTER
01 02
1. SAFETY INFORMATION
Users must read and follow all safety instructions
before using this unit in order to prevent personal
injury or damage to the unit.
1.Please check that there is no damage to the unit or
insulation.
2.Input should not exceed more than AC 250V, 15A in order
to avoid electrical shock or danger.
3.Don’t open the back cover to avoid damaging the insulation.
4.Turn off power first before removing the test leads from
the voltage test jacks.
2. GENERAL DESCRIPTION
This instrument is a special accessory for clamp meters
which can be used to measure current conveniently without
breaking the insulation on equipment’s power line. It can
also be used to test the equipment’s working voltage using
a multimeter. It’s an essential tool for safely taking electrical
measurements with little damage to the equipment under
test. Its quality construction and easy to use design is built
according to IEC61010 standards with an overvoltage
category of 250V CAT III.
3. FEATURES
1Safety standard conforms to IEC61010.
2.Maximum input: AC 250V, 15A.
3.Operating temperature: 0~40°C;
Humidity: ≤90%
4.Storage temperature: 10~50°C;
Humidity: ≤90%
5.Dimensions: 161×57×31 mm
6.Weight: approx. 106g
7.Accessories: user’s manual
.
4. SAFETY SYMBOLS
L
N
Important safety information:refer to the user’s
manual
Dangerous voltage may be present
Double insulation
Earth ground
Live wire connection for voltage test
Neutral wire connection for voltage test
DZA50
05 00-05-3606
0403
5. FRONT PANEL 5.1 Front panel description
1. Power plug:
This is a standard plug as shown below:
Overload protection: AC 250V, 15A
2. “X1” current terminal:
Tests actual working current.
3. “X10” current terminal:
Tests working current x10.
4. Voltage test input sockets:
Insert test lead probes to measure voltage.
5. Input socket:
Maximum input: AC 250V, 15A.
This socket is suitable for two standard plug configurations.
These configurations are shown in the figure below:
6. OPERATING INSTRUCTIONS
6.1 Current testing
Each terminal of the splitter will give a different current
reading:
X1 terminal for normal current load.
X10 terminal for 10 times the normal current load.
The error of the clamp meter itself will influence the
testing degree of accuracy.
6.2 Voltage testing
1 Connect the power plug to an outlet.
2. Plug the device to be measured into the input socket.
3. Connect the test leads of your multimeter to the voltage
test sockets and put the meter in AC voltage mode to
measure the voltage of the connected device.
.
6.3 Power testing
1 Connect the power plug to an outlet.
2. Plug the device to be measured into the input socket.
3. Connect the test leads of your multimeter to the voltage
test sockets and put the meter in AC voltage mode to
measure the voltage of the connected device.
4. Use a clamp meter and clamp the desired current terminal
of the line splitter for measurement.
5. Calculate the power of the connected device using the
following formula:
Power = voltage x current
.
Maximum input is: AC 250V, 15A.
1. Connect the power plug to an outlet.
2. Plug the device to be measured into the input socket.
3. Use a clamp meter and clamp the desired current terminal
of the line splitter for measurement.
1
2
3
4
5
DZA50