Dea DIGIRAD N Product manual

DIGIRAD N
I63005 Rev. 00 (28-11-2022)

DIGIRAD N
11
EN
DIGIRAD N
Radio digital selector
Operating instructions and
warnings
Summary
1Warning summary 11 7Available functions 14
2Product description 12 8Settings 17
3Technical data 12 9Connection with APP 19
4Installation and assembly 12 10 Battery status and replacement check 19
5Simplified programming menu 13 11 Product Disposal 19
1 WARNINGS SUMMARY
WARNING! IMPORTANT SAFETY INSTRUCTIONS. CAREFULLY READ AND FOLLOW ALL WARNINGS AND INSTRUC-
TIONS THAT ACCOMPANY THE PRODUCT SINCE INCORRECT INSTALLATION COULD CAUSE HARM TO PEOPLE, ANIMALS
OR OBJECTS. WARNINGS AND INSTRUCTIONS PROVIDE IMPORTANT INFORMATION REGARDING SAFETY, INSTALLA-
TION, USE AND MAINTENANCE. KEEP THE INSTRUCTIONS TOGETHER WITH THE TECHNICAL DOCUMENTATION AND FOR
FUTURE REFERENCE.
WARNING Do not allow children to play with the appliance. The device may be used
by children of not less than 8 years of age, people with reduced physical, mental or
sensory impairment, or generally anyone without experience or, in any case, the required
experience provided the device is used under surveillance or that users have received
proper training on safe use of the device and are aware of the dangers related to its use.
WARNING Fixed installation command (buttons, etc.) must be situated out of the
reach of children at a height of at least 150 cm from the ground. Do not allow children
to play with the device, the fixed commands or the radio controls of the system.
WARNING Under no circumstances use the device in an explosive atmosphere or in
areas that may be corrosive or could damage product parts. Check that the
temperatures at the installation site are suitable and comply with the temperatures
declared on the product label.
WARNING In compliance with EU Directive 2012/19/EG on waste electrical and electronic
equipment (WEEE), this electrical product should not be treated as municipal mixed
waste. Please dispose of the product and bring it to the collection for an appropriate local
municipal recycling.
EVERYTHING THAT IS NOT EXPRESSLY PROVIDED FOR IN THE INSTALLATION MANUAL IS NOT ALLOWED. CORRECT
OPERATOR OPERATION IS ONLY ENSURED WHEN THE REPORTED DATA IS RESPECTED. THE COMPANY DOES NOT
TAKE RESPONSIBILITY FOR DAMAGE CAUSED BY FAILURE TO COMPLY WITH THE INSTRUCTIONS CONTAINED IN THIS
MANUAL. WITHOUT AFFECTING THE ESSENTIAL FEATURES OF THE PRODUCT, THE COMPANY RESERVES THE RIGHT
TO MAKE ANY CHANGES DEEMED APPROPRIATE AND AT ANY TIME IN ORDER TO TECHNICALLY, STRUCTURALLY AND
COMMERCIALLY IMPROVE THE PRODUCT WITHOUT BEING REQUIRED TO UPDATE THIS DOCUMENT.

DIGIRAD N
12
2 PRODUCT DESCRIPTION
DIGIRAD N is a four-channel radio keypad selector designed to control compatible DEA SYSTEM command units and/or receivers.
The selector can work both indoors and outdoors and being powered by batteries, it does not require wiring.
The integrated circuit has 2 distinct serial numbers. The first S/N_D (device serial number) is used to identify the selector within the DEA
System NET-LINK ecosystem and cannot be changed, the second S/N_R (radio serial number) is used to send commands to the paired
devices by simulating the operating logic of a 4-buttons remote.
3 TECHNICAL DATA
Power supply 2x CR2450 batteries in series (lithium-ion, 3V)
Dusk sensor
Keypad
Status LEDs
Battery life 2 years with 10 activations per day (with
backlight time-out at default)
Radio frequency 433.92 MHz
Radio coding HCS Rolling Code, Dip Switch, D.A.R.T.
Radio channels 4
Radio signal range 200m in open field
40m for indoor use
Access codes Max 300
Code length 2 to 8 digits
Degree of protection IP54
Operating temperature -20÷50 °C
Product dimensions 137x74x28 mm
Product weight 200 g
4 INSTALLATION AND ASSEMBLY
WARNING: For assembly and / or disassembly operations, always use the most appropriate equipment, meticulously following the
regulations in force in the sales Country.
WARNING: Remove the lid carefully following the instructions. Do not remove parts by forcing components.
WARNING: Fixed installation controls (buttons, etc.) must be located out of the reach of children at least 150 cm above the ground.
WARNING: Do not mount the selector near or even on metal surfaces (including mirrored glass) as this could compromise its operation,
in particular with regard to the transmission distance.
Before installation, identify the place to mount the selector making sure that the distance from the respective receivers does not exceed
the maximum declared range (see paragraph “3. TECHNICAL DATA”).
It is also advisable to perform some transmission tests from a greater distance, in order to ensure correct operation even with a flat
battery.
Please proceed according to the following points:
• Open the device by unscrewing and removing the special screw on the bottom with the wrench provided;
• Drill the support surface following the measurements indicated in Pic. 4, taking into account whether it requires the use of the
supplied expansion plugs;
• Place the insulating pad between the wall and the rear base of the selector and fix the base with the supplied screws (Pic. 5);
• Remove the 2 insulating tabs from the batteries, checking that the selector works correctly (Pic. 3);
• Before closing the upper part, make sure that the silicone gasket has been reassembled and is not damaged;
• Hook the upper part of the selector to the base previously fixed to the wall and tighten the special screw on the bottom (Pic. 6).
WARNING: When reassembling the upper part of the selector, slightly tilt the shell to facilitate the interlocking and apply a slight downward
pressure (Pic. 7).

DIGIRAD N
13
EN
5 SIMPLIFIED PROGRAMMING MENU
PROGRAMMING MODE ACTIVATION (Enter 1 + 3 for 5 seconds)
HOME (fix white LED)
FUNCTION
1 fast blink
PARAMETERS
2 fast blinks
VALUES
Follow what is described in paragraph “6. AVAILABLE FUNCTIONS ”for an in-depth description
DEFAULT
1Adding codes
1Direct command
1Single
code
3 fast blinks
Follow the
procedure
indicated in
points 6.6 and
6.7
/
2Multiple command
2Deleting codes 1Single code cancellation Follow the indicated procedure
in point 6.8
2Total cancellation
3INSTALLER code 1Adding INSTALLER code Follow the indicated procedure
in point 6.9
2Erasing the INSTALLER code
4Not available //
5Not available
9Setting
1Radio coding
1HCS Rolling Code
12Dip Switch
3D.A.R.T.
2Backlight logic 1Always OFF 2
2ON with low light
3Backlight intensity level
1Minimum
1
2Low
3Average
4High
5Maximum
4Backlight time-out _ _ _ Enter seconds (1-255) 3
5Command time-out _ _ _ Enter seconds (1-255) 5
6Code length _ _ _ Enter value (2-8) 4
7Sound feedback 1ON 1
2OFF
8Factory reset 1Reset of the settings only /
2Total reset
Once the programming mode has been activated (see paragraph 6.2) and the HOME level has been entered, it is possible to use the
DIGIRAD N keys to navigate between the various programming levels and modify the stored values.
• Use the numeric keys from 0to 9for numeric selections (function-parameter-value choice);
• Use the Ekey to confirm the function or parameter and store the value;
• Use the Ckey to cancel (short press). It also allows you to return to the HOME level (press for 1 second), or completely exit
programming mode (press for 5 seconds).
Example - “Set Command time-out to a duration of 10 seconds”: In programming mode, enter: 9 E + 5 E + 10 E
Example - “Turn off Sound feedback”: In programming mode, enter: 9 E + 7 E + 2 E
In general, after changing a value in functions 3-4-5-9 it will automatically return to the HOME level.
In the case of functions 1 and 2, on the other hand, after adding (or deleting) the first code and assigning a channel, DIGIRAD N will wait
for further codes so if you want to end the operation, you will need to press the Ckey to exit.

DIGIRAD N
14
6 AVAILABLE FUNCTIONS
6.1 Typing feedback
In general, with the sound feedback active (default setting), there is sound feedback every time a key is pressed.
At the end of typing, the status LEDs on the top of the selector are always active, to indicate the outcome of an operation both in normal
use and in programming.
CORRECT CODE or SUCCESSFUL PROGRAMMING: prolonged beep and green LEDs on.
WRONG CODE or PROGRAMMING FAILED: 3 short beeps and red LEDs on.
6.2 Keypad activation
To prolong the battery life and in the absence of active commands, the selector will normally be in stand-by mode. To wake it up, simply
press any key on the numeric keypad.
The awakening will be confirmed by:
• Short blink of the upper red and white LEDs.
• Activation of the keypad backlight (if enabled and if there is a low light condition).
If no key is pressed (and you are not in programming mode), the keypad switches off and returns to stand-by once the time defined in the
backlight time-out has elapsed (see paragraph 7.4).
6.3 Memorization on DEA SYSTEM devices
DIGIRAD N is factory programmed with 4 access codes, in order to allow a first rapid programming on control units or receivers with
433MHz radio frequency and set in HCS (Rolling-code or Fixed-code) encoding:
1111 to activate radio channel CH1 (= key 1 of a remote)
2222 to activate radio channel CH2 (= key 2 of a remote)
3333 to activate radio channel CH3 (= key 3 of a remote)
4444 to activate radio channel CH4 (= key 4 of a remote)
• Put the DEA SYSTEM control unit or receiver in radio learning mode (P005 on RR or NET series control units, rA.02 on NET-EVO
series control units, P1 key on receivers);
• Press any key on the numeric keypad to activate DIGIRAD N; the red and white LEDs will blink briefly;
• If you are memorizing on a receiver, it will be important to enter the code corresponding to the radio channel to be saved; For the
control units, on the other hand, indifferently enter one of the 4 codes assigned to the radio channels;
• Return the control unit or the receiver to normal use conditions and check that the command is sent by typing the code just
memorized on the keypad.
For security reasons, it is recommended to delete the default codes and replace them with new access codes at the end of the
device pairing operations. It will not be necessary to repeat the memorization of DIGIRAD N on the previously paired DEA System
devices.
6.4 Access to programming mode
To modify or simply access the DIGIRAD N functions, you will first need to enter programming mode.
Follow the steps below:
• Press any key to activate DIGIRAD N;
• Press and hold keys 1and 3for 5 seconds. The buzzer will emit a continuous beep; release the keys at the end of the beep;
• The white LED lights up fix, indicating that you are in programming mode.
Use the E and C keys during programming respectively to:
E: confirm
C: cancel, return to the previous menu (single press)
If, in addition to the fix white LED, the red and green LEDs also light up blinking, it means that the programming mode has been locked
by means of an installer code (see paragraph 6.9).
Within 15s enter the installer code (if you know it) and confirm with the Ekey to access the programming mode. Only the fix white LED
will remain on. If a valid installer code is not entered, after 15s the selector will return to stand-by mode.
6.5 Exit programming mode
Programming mode can be exited in two ways:
• Press and hold the Ckey for 5 seconds. The buzzer will emit a continuous beep. Release the key at the end of the beep.
• Alternatively, the programming mode will automatically exit after 2 minutes from the last press of any key.
Table of contents