DecaLED Controller 3 Mini User manual

DecaLED®Controller 3 Mini
95350246
Manual
Description
Read this manual carefully before using our DecaLED®Controller 3 Mini. The DecaLED®Controller 3 Mini provides
a control interface and power for DecaLED®24V products. A maximum of 6 channels (2x RGB channels) can
be controlled separately, only a maximum loading capacity of 3A(1A per individual channel) is allowed on a
single output and the maximum amount of the total load can not exceed 4A distributed over all 2 outputs.
Package contents
1 x DecaLED®Controller 3 Mini
1 x DecaLED®Control Remote (Infrared Remote Control)
1 x IR EYE sensor(External connected infrared receiver sensor)
1 x Connection cord for the power supply
1 x Manual
Carefully unpack the carton. Check the contents to ensure that all parts are present and have been received
in good condition. If any parts appear damaged or missing, notify the shipper immediately and retain packing
material for inspection. In the event that the xture must be returned to the factory, it is important that the
xture is returned in the original factory box and packaging.
Features
USITT Standard DMX-512(1990) multiplexed digital control.
A maximum of 6 channels (2x RGB channels) can be controlled separatelyseparately, only a maximum
loading capacity of 3A(1A per individual channel) is allowed on a single output and the maximum amount of
the total load can not exceed 4A distributed over all 2 outputs.
Available in DecaLED®Setup Tool Control Mode, Full DMX Control Mode, Stand Alone Mode(Manual)
and IR Control Mode.
In DecaLED®Setup Tool Control Mode, available in Slave Control mode(DMX Mode) and Master mode.In
DMX Mode, allows to congure different load output modes as needed, consisting of RGB mode, Color
mode, Color &Brightness mode and Single mode. In Master Mode, available in Manual Mode and Auto
Mode,allows to select 1~10 patterns plus a sequence of 10 patterns with chase speed & fade time.
In Full DMX Control Mode, allows to set up DMX starting address.
In Stand Alone(Manual) Mode, built-in 1~8 patterns selection with chase speed & fade time is available by
conguring the dip switch.
In IR Control Mode, allows to set work modes and relative parameters with LED Remote control operation. Built-
in IR and external connected IR EYE sensor are optional. R.G.B. Color intensity can be adjustable separately.
And 1~10 patterns plus a sequence of 10 patterns selection with chase speed & fade time is available.
Improvements and specications in the design of the unit and the manual are subject to change without any
prior written notice.
User Instructions
DecaLED Controller 3 Mini
for 24V
Part No.:24-004-2392-00
Version:1.0
Product Code:95350246
www.decaled.com
for 24V
Product code: 95350246
0 Dip Switches
1 Setup tool
SETUP TOOL
1=ON
0= OFF
11
IR
1=ON
0= OFF
12
0 IR OFF
1 IR ON
on
12345678910
RSON
DMX Address (Slave)
(Dip Switches 10 = on)
Start
CH#
Start
CH#
Switches On Switches On
1
2
3
4
5
6
7
8
9
10
1
2
1,2
3
1,3
2,3
1,2,3
4
1,4
2,4
1,2,4
3,4
1,3,4
2,3,4
1,2,3,4
:
:
:
:
1,2,3,4,5,6,7,8,9
11
12
13
14
15
:
:
:
:
511
000
100
010
110
001
101
011
111
Fade Time Speed Program
0%
:
:
:
:
:
:
100%
000
100
010
110
001
101
011
111
0.1S
0.2S
0.5S
1S
5S
10S
20S
30S
000
100
010
110
001
101
011
111
1
2
3
4
5
6
7
Auto
12345678910
RSON
Stand Alone
(Dip Switches 10 = off)
on
123
on
456
on
789
on
Controller 3 Mini

Precautions
This product is designed to control DecaLED• ®24V products and may not be used in conjunction with other
appliances.
Never open the housing without removing the power supply. Some parts may still powered.•
Only qualied personnel may open the housing. •
The DecaLED• ®Controller 3 Mini is only suited for indoor use.
Check the DecaLED• ®Controller 3 Mini for visible damage before use.
Never exceed the maximum allowed amount of strips to connect and choose a high quality connection•
cord.
Do not cover the ventilation area on the backside of the device. The cooling area may reach high•
temperatures, so make sure there is enough room for ventilation. Do not put other devices on top of or
behind this device.
If you nd a defect, immediately turn off the device and contact your distributor. •
Do not insert objects into the ventilation openings.•
Do not use this device in humid environments.•
Do not use this device in environments with strong magnetic elds and strongly polluted and/or dusty •
rooms.
All directions for installation and usage that are applicable to this product must be observed. Only let•
qualied personnel work on electric connections and service.
Cleaning
Only clean the product when the device is disconnected from the power supply.•
Use a dry and smooth cloth for cleaning.•
Do not use aggressive chemicals.•
Do not let liquids penetrate the device.•
Never use sharp objects when cleaning.•
Warranty
This product is guaranteed to have no defects as a result of material and manufacturing mistakes for a•
period of one year after the date of purchase.
This guarantee only comprises parts that have broken down and repairing costs.•
Repairing will only be done under warranty if it is convincingly proven (for example by way of an invoice)•
that the day on which the complaint has been led is within the guarantee period.
The manufacturer cannot be held liable when the defect has occurred as a result of improper use, bad
maintenance, use in an unsuitable environment or when repairs have been made by unqualied personnel.
Controls and functions
Front Panel View
1. Power adapter input, 100-240VAC, 50/60Hz, 100W
2. Fuse holder Use only with a 250V fuse
3. Power switch ON/OFF
Power
DMX
1
DMX out
Controller 3 Mini for 24V
Product code: 95350246
IR
IR
EXT. Sensor
2
1234
BRG
+
DMX in
1 = Ground;2=Data-;3=Data+
Max. Total 100W
Max. 70W per output
on
DMX Address Setting
1
2
3
4
5
6
7
8
9
0
1
2
4
8
16
32
64
128
256
Stand alone
(Dipswitch 10 = OFF)
1 - 3 Fade time
4-6Speed
7 - 9 Program
Setup Tool
123
Made in PRC
CAUTION:
DO NOT OPEN!
CAUTION:
RISK OF ELECTRIC SHOCK
THIS UNIT MUST BE GROUNDED
RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR!
METTRE CETTE APPAREIL A LA MASSE
Serial Number:
POWER
www.decaled.com
POWER IN:
100-240V 50/60Hz 100WAC,
Product code: 95350246
Controller 3 Mini
for 24V
FUSE:
T2.5A 250V 5x20mm
Rear Panel View
1.
Green LED (flashing) indication for DMX signal.
Quick flashing: an DecaLED Setup tool is updating.
Slow flashing: DMX signal active.
2.
Red LED (power) indication for presence of tension.
3. (3-pin XLR socket / Terminal Strip)
XLR chassis part male, 3-polar for DMX connection.
4.
XLR chassis part female, 3-polar for DMX Output.
DMX LED
Power LED
DMX / Programming input
DMX output (connection) (3-pin XLR socket / Terminal Strip)
5. 24
4-polar terminal strips*2pcs for connecting DecaLED RGB modules(24V DC).
Never connect the DMX signal and the Setup Tool to an XLR 3-polar input or output simultaneously.
This can severely damage your DecaLED Controller 3 Mini for 24V.
6.
7. To connect an external connected IR EYE sensor
8.
To set work modes and relative parameters
V DC outputs
Built-in IR sensor
IR in
10-digit Addressing Dip Switch & 2-digit Function Dip Switch
Note:
R
R
R
Controls & Functions:
1. AC100~240V, 50/60Hz
2. Use only with a 250V fuse
3. ON/OFF
Power input
Fuse holder
Power switch
Front Panel View
1
2
3
12
34345
678
Physical Dimensions:
-Page 3-

Rear Panel View
1. DMX LED
Green LED (ashing) DMX signal indicator. Quick ashing: a DecaLED® Setup tool is up dating. Slow ashing:
DMX signal active.
2. Power LED
Red LED (power) Power indicator
3. DMX / Programming input (3-pin XLR socket / Terminal Strip) XLR chassis part male, 3-polar for DMX
connection.
4. DMX output (connection) (3-pin XLR socket / Terminal Strip) XLR chassis part female, 3-polar for DMX
Output.
5. 12V DC outputs
4-polar terminal strips*2pcs for connecting DecaLED® 24V products.
Note: Never connect the DMX signal and the DecaLED®Setup Tool to an XLR 3-polar input or output
simultaneously. This can severely damage your DecaLED®Controller 3 Mini.
6. Built-in IR sensor
7. IR in to connect an external connected IR EYE sensor
8. 10-digit addressing dip switch & 2-digit function dip switch
to set work modes and related parameters
Physical Dimensions
Power
DMX
1
DMX out
Controller 3 Mini for 24V
Product code: 95350246
IR
IR
EXT. Sensor
2
1234
BRG
+
DMX in
1 = Ground;2=Data-;3=Data+
Max. Total 100W
Max. 70W per output
on
DMX Address Setting
1
2
3
4
5
6
7
8
9
0
1
2
4
8
16
32
64
128
256
Stand alone
(Dipswitch 10 = OFF)
1 - 3 Fade time
4-6Speed
7 - 9 Program
Setup Tool
123
Made in PRC
CAUTION:
DO NOT OPEN!
CAUTION:
RISK OF ELECTRIC SHOCK
THIS UNIT MUST BE GROUNDED
RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR!
METTRE CETTE APPAREIL A LA MASSE
Serial Number:
POWER
www.decaled.com
POWER IN:
100-240V 50/60Hz 100WAC,
Product code: 95350246
Controller 3 Mini
for 24V
FUSE:
T2.5A 250V 5x20mm
Rear Panel View
1.
Green LED (flashing) indication for DMX signal.
Quick flashing: an DecaLED Setup tool is updating.
Slow flashing: DMX signal active.
2.
Red LED (power) indication for presence of tension.
3. (3-pin XLR socket / Terminal Strip)
XLR chassis part male, 3-polar for DMX connection.
4.
XLR chassis part female, 3-polar for DMX Output.
DMX LED
Power LED
DMX / Programming input
DMX output (connection) (3-pin XLR socket / Terminal Strip)
5. 24
4-polar terminal strips*2pcs for connecting DecaLED RGB modules(24V DC).
Never connect the DMX signal and the Setup Tool to an XLR 3-polar input or output simultaneously.
This can severely damage your DecaLED Controller 3 Mini for 24V.
6.
7. To connect an external connected IR EYE sensor
8.
To set work modes and relative parameters
V DC outputs
Built-in IR sensor
IR in
10-digit Addressing Dip Switch & 2-digit Function Dip Switch
Note:
R
R
R
Controls & Functions:
1. AC100~240V, 50/60Hz
2. Use only with a 250V fuse
3. ON/OFF
Power input
Fuse holder
Power switch
Front Panel View
1
2
3
12
34345
678
Physical Dimensions:
-Page 3-
Power
DMX
1
DMX out
Controller 3 Mini for 24V
Product code: 95350246
IR
IR
EXT. Sensor
2
1234
BRG
+
DMX in
1 = Ground;2=Data-;3=Data+
Max. Total 100W
Max. 70W per output
on
DMX Address Setting
1
2
3
4
5
6
7
8
9
0
1
2
4
8
16
32
64
128
256
Stand alone
(Dipswitch 10 = OFF)
1 - 3 Fade time
4-6Speed
7 - 9 Program
Setup Tool
123
Made in PRC
CAUTION:
DO NOT OPEN!
CAUTION:
RISK OF ELECTRIC SHOCK
THIS UNIT MUST BE GROUNDED
RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR!
METTRE CETTE APPAREIL A LA MASSE
Serial Number:
POWER
www.decaled.com
POWER IN:
100-240V 50/60Hz 100WAC,
Product code: 95350246
Controller 3 Mini
for 24V
FUSE:
T2.5A 250V 5x20mm
Rear Panel View
1.
Green LED (flashing) indication for DMX signal.
Quick flashing: an DecaLED Setup tool is updating.
Slow flashing: DMX signal active.
2.
Red LED (power) indication for presence of tension.
3. (3-pin XLR socket / Terminal Strip)
XLR chassis part male, 3-polar for DMX connection.
4.
XLR chassis part female, 3-polar for DMX Output.
DMX LED
Power LED
DMX / Programming input
DMX output (connection) (3-pin XLR socket / Terminal Strip)
5. 24
4-polar terminal strips*2pcs for connecting DecaLED RGB modules(24V DC).
Never connect the DMX signal and the Setup Tool to an XLR 3-polar input or output simultaneously.
This can severely damage your DecaLED Controller 3 Mini for 24V.
6.
7. To connect an external connected IR EYE sensor
8.
To set work modes and relative parameters
V DC outputs
Built-in IR sensor
IR in
10-digit Addressing Dip Switch & 2-digit Function Dip Switch
Note:
R
R
R
Controls & Functions:
1. AC100~240V, 50/60Hz
2. Use only with a 250V fuse
3. ON/OFF
Power input
Fuse holder
Power switch
Front Panel View
1
2
3
12
34345
678
Physical Dimensions:
-Page 3-

Connecting the power supply
Check whether or not the source voltage in your area matches the required voltage for the controller power
supply. Note: If the source voltage is 110V, do NOT connect a 230V power supply. This can severely damage
your device. The DecaLED®Controller 3 Mini is supplied with a power cable. The device is powered by an
IEC cord which ts into the power adapter (1) on the backside of the device. Keep pushing the IEC until it is
xed into position in the adapter. The device can be turned on by using the power switch. An indicator shows
whether the device is turned on or off.
Connecting the DecaLED®24V products to the DecaLED®Controller 3 Mini.
Conguration
1. Maximum amount of connected DecaLED®24V products
A maximum of 6 channels (2x RGB channels) can be controlled separatelyseparately, only a maximum
loading capacity of 3A(1A per individual channel) is allowed on a single output and the maximum amount of
the total load can not exceed 4A distributed over all 2 outputs.
2. Connector conguration
The DMX conguration is depicted below. The DMX connections consist of one XLR 3 male connector (input)
and one XLR 3 female connector (transited output) or 3-polar terminal connector.
The XLR 3-polar connector: 1 = ground, 2 = data -, 3 = data +
3. Connector conguration outputs - The output conguration is depicted below. The output connections
consist of eight 5-polar terminal connectors.
The 4-polar terminal connector:
1 = +
2 = R
3 = G
4 = B
A 120 ohm impedance DMX signal cable MUST be used for signal connection.
Configuration:
1. Maximum amount of connected
A maximum of 24 channels (8x RGB channels) can be controlled separately. The maximum amount of connected
DecaLED RGB modules must not exceed 250. Please note: only 50 modules are allowed on a single output.
2. Connector configuration
The DMX configuration is depicted below. The DMX connections consist of one XLR 3 male connector (input) and
one XLR 3 female connector (transited output) or 3-polar terminal connector .
DecaLED RGB modules
The XLR 3-polar connector: 1 = GROUND
2 = DATA -
3 = DATA +
Chassis part XLR-3 male Chassis part XLR-3 female
The 5-polar terminal connector:
3. Connector configuration outputs
The output configuration is depicted below. The output connections consist of eight 5-polar terminal connectors.
5-polar terminal connector
R
R
3-polar terminal connector
1 = Blue
2 = Red
3 = Green
4 = White
5 = Yellow
NOTE:
DMX signal cable: 120 ohm impedance DMX signal cable MUST be used for signal connection.
Connecting the Tension Provider
Check whether or not the source Voltage in your area matched the required voltage for the controller power supply.
Note: If the source Voltage is 110V, do NOT connect a 230V power supply. This can severely damage your device.
The Controller comes with a complete power cable. The device is powered by an IEC cord which fits into the power
adapter (1) on the backside of the device. Keep pushing the IEC until it is fixed into position in the adapter. The
device can be turned on by means of a power switch. An indicator shows whether the device is turned on or off.
Connecting the DecaLED RGB modules to the DecaLED Controller 1 for RGB modules
Only 50pcs DecaLED RGB modules
are allowed on a single output and the
maximum amount of connected modules
can not exceed 250pcs.
R
DMX Controller A LED Setup Tool
(XB-R1)
Or
DecaLED Controller 1
for RGB modules
(A Driver Unit)
DMX out
DMX in
R
RR
IR EYE(Sensor)
LED REMOTE
IR In
-Page 5-
Configuration:
1. Maximum amount of connected
A maximum of 6 channels (2x RGB channels) can be controlled separately. O
2. Connector configuration
The DMX configuration is depicted below. The DMX connections consist of one XLR 3 male connector (input) and
one XLR 3 female connector (transited output) or 3-polar terminal connector .
DecaLED RGB modules(24V)
nly a maximum loading capacity of
3A(1A per individual channel) is allowed on a single output and the maximum amount of the total load can not
exceed 4.5A distributed over all 2 outputs.
The XLR 3-polar connector: 1 = GROUND
2 = DATA -
3 = DATA +
Chassis part XLR-3 male Chassis part XLR-3 female
The 4-polar terminal connector:
3. Connector configuration outputs
The output configuration is depicted below. The output connections consist of eight 4-polar terminal connectors.
4-polar terminal connector
R
3-polar terminal connector
1=+
2=R
3=G
4=B
NOTE:
DMX signal cable MUST: 120 ohm impedance DMX signal cable be used for signal connection.
Connecting the Tension Provider
The device is powered by an IEC cord which fits into the power socket on the backside of the device. Keep pushing
the IEC until it is fixed into position in the socket. The device can be turned on by means of the power switch. An
indicator shows whether the device is turned on or off.
Connecting the DecaLED RGB modules(24V) to the DecaLED Controller 3 Mini for 24V
DMX Controller DecaLED Setup Tool
Or
DecaLED Controller 3 Mini
for 24V
(A Driver Unit)
DMX out
DMX in
R
RR
Only a maximum loading capacity of 3A(1A
per individual channel) is allowed on a single
output and the maximum amount of the total
load can not exceed 4.5A distributed over all
2 outputs.
-Page 4-
IR EYE(Sensor)
LED REMOTE
IR In
R
Configuration:
1. Maximum amount of connected
A maximum of 24 channels (8x RGB channels) can be controlled separately. O
2. Connector configuration
The DMX configuration is depicted below. The DMX connections consist of one XLR 3 male connector (input) and
one XLR 3 female connector (transited output) or 3-polar terminal connector .
DecaLED RGB modules(12V)
nly a maximum loading capacity of
3A(1A per individual channel) is allowed on a single output and the maximum amount of the total load can not
exceed 12A distributed over all 8 outputs.
The XLR 3-polar connector: 1 = GROUND
2 = DATA -
3 = DATA +
Chassis part XLR-3 male Chassis part XLR-3 female
The 4-polar terminal connector:
3. Connector configuration outputs
The output configuration is depicted below. The output connections consist of eight 4-polar terminal connectors.
4-polar terminal connector
R
3-polar terminal connector
1 = +
2 = R
3 = G
4 = B
NOTE:
DMX signal cable: 120 ohm impedance DMX signal cable MUST be used for signal connection.
Connecting the Tension Provider
Check whether or not the source Voltage in your area matched the required voltage for the controller power supply.
Note: If the source Voltage is 110V, do NOT connect a 230V power supply. This can severely damage your device.
The Controller comes with a complete power cable. The device is powered by an IEC cord which fits into the power
adapter (1) on the backside of the device. Keep pushing the IEC until it is fixed into position in the adapter. The
device can be turned on by means of a power switch. An indicator shows whether the device is turned on or off.
Connecting the DecaLED RGB modules(12V) to the DecaLED Controller 2 for 12V
DMX Controller A LED Setup Tool
(XB-R1)
Or
DecaLED Controller 2
for 12V
(A Driver Unit)
DMX out
DMX in
R
RR
Only a maximum loading capacity of 3A(1A
per individual channel) is allowed on a single
output and the maximum amount of the total
load can not exceed 12A distributed over all
8 outputs.
IR EYE(Sensor)
LED REMOTE
IR In
-Page 5-

Operation guide
1. DecaLED®Setup Tool Control Mode-Programming
DecaLED®Setup Tool Control Mode enabled.
In this mode, the dip switch 11 (2-digit function dip switch) is ipped to the “ON”
position and RGB output loading is set by default.
A DecaLED®Setup Tool is required to program the DecaLED®Controller 3 Mini. For
further information, please refer to its accompanying manual.
1.1. Slave control (DMX Mode)
In Slave control mode, the settings for the addresses(001-512) and the Glide effect
functions can be congured with a DecaLED®Setup Tool. There are 6 work modes
for Slave control. A DecaLED®Setup Tool (Sold separately)
MODE-1 RGB mode (6 channels in total=2x3 channels)
2 RGB mode: has 2 groups with RGB output, of which each group consists of 3 channels (6 channels in total).
MODE-2 Color and Brightness mode (4 channels in total=2x2 channels)
2 C&B mode: has 2 groups with colour and intensity C&B output, of which each group consists of 2 channels
(4 channels in total).
MODE-3 Color mode (2 channels in total=2x1 channels)
2 COLOR mode: has 2 groups with colour control, of which each group consists of 1 channel (2 channels in
total). The brightness is always 100% in this mode.
MODE-4 Patch mode RGB of 2 outputs---->1 outputs (1x3 channels)
1 RGB mode: in this mode, 2 outputs are patched.
Operation Guide:
1. DecaLED Setup Tool Control Mode-Programming
A LED Setup Tool (DecaLED Setup Tool) is required to program
DecaLED Controller 2 Mini for 12V RGB modules. For further information,
please refer to its accompanying manual.
1.1. Slave Control(DMX Mode)
DecaLED Setup Tool Control Mode enables.
In this mode, the Dip Switch 11 (2 ) is flipped to the " "
position and R.G.B. output loading is set by default.
-digit Function Dip Switch ON
1
2
4
5
36
Group 1 Group 2
Color (R/G/B) Channel 1-6 / Group 1-2
Output 1 Output 2
Red
Blue
MODE-1 RGB mode (6 channels in total=2x3 channels)
2 RGB mode: has 2 groups with RGB output, of which each group consists of 3 channels(6 channels in total).
1
2
3
4
C&B
Color
Brightness
Group 1 Group 2
Channel 1-4 / Group 1-2
Output 1 Output 2
2 C&B mode: has 2 groups with color and intensity C&B output, of which each group consists of 2 channels
(4 channels in total).
MODE-2 Color and Brightness mode(4 channels in total=2x2 channels)
12
C&B
Color
Group 1 Group 2
Channel 1-2 / Group 1-2
Output 1 Output 2
100% 100%
Brightness
2 COLOR mode: has 2 groups with Color control, of which each group consists of 1 channel (2 channels in total).
The brightness is always 100% in this mode.
MODE-3 Color mode(2 channels in total=2x1 channels)
-Page 5-
In Slave Control, the settings for the addresses(001-512) and the Glide Effect
functions can be configured with DecaLED Setup Tool. There are 6 work modes
for Slave Control.
R
11
12
ON
OFF
1=
0=
DecaLED Setup Tool
(Sold separately)
R
R
R
R
3
Blue
MODE-4 Patch mode RGB of 2 outputs---->1 output(1x3 channels)
1 RGB mode: in this mode, 2 outputs are patched.
Channel 1-3
Group 1/
Output 1-2
Color (R/G/B)
1
Red
2
LED Setup Controller
www.decaled.com
R
A
T
E
REV FWD
Productcode:95350247
Setup Tool
Operation Guide:
1. DecaLED Setup Tool Control Mode-Programming
A LED Setup Tool (DecaLED Setup Tool) is required to program
DecaLED Controller 2 Mini for 12V RGB modules. For further information,
please refer to its accompanying manual.
1.1. Slave Control(DMX Mode)
DecaLED Setup Tool Control Mode enables.
In this mode, the Dip Switch 11 (2 ) is flipped to the " "
position and R.G.B. output loading is set by default.
-digit Function Dip Switch ON
1
2
4
5
36
Group 1 Group 2
Color (R/G/B) Channel 1-6 / Group 1-2
Output 1 Output 2
Red
Blue
MODE-1 RGB mode (6 channels in total=2x3 channels)
2 RGB mode: has 2 groups with RGB output, of which each group consists of 3 channels(6 channels in total).
1
2
3
4
C&B
Color
Brightness
Group 1 Group 2
Channel 1-4 / Group 1-2
Output 1 Output 2
2 C&B mode: has 2 groups with color and intensity C&B output, of which each group consists of 2 channels
(4 channels in total).
MODE-2 Color and Brightness mode(4 channels in total=2x2 channels)
12
C&B
Color
Group 1 Group 2
Channel 1-2 / Group 1-2
Output 1 Output 2
100% 100%
Brightness
2 COLOR mode: has 2 groups with Color control, of which each group consists of 1 channel (2 channels in total).
The brightness is always 100% in this mode.
MODE-3 Color mode(2 channels in total=2x1 channels)
-Page 5-
In Slave Control, the settings for the addresses(001-512) and the Glide Effect
functions can be configured with DecaLED Setup Tool. There are 6 work modes
for Slave Control.
R
11
12
ON
OFF
1=
0=
DecaLED Setup Tool
(Sold separately)
R
R
R
R
3
Blue
MODE-4 Patch mode RGB of 2 outputs---->1 output(1x3 channels)
1 RGB mode: in this mode, 2 outputs are patched.
Channel 1-3
Group 1/
Output 1-2
Color (R/G/B)
1
Red
2
LED Setup Controller
www.decaled.com
R
A
T
E
REV FWD
Productcode:95350247
Setup Tool
Operation Guide:
1. DecaLED Setup Tool Control Mode-Programming
A LED Setup Tool (DecaLED Setup Tool) is required to program
DecaLED Controller 2 Mini for 12V RGB modules. For further information,
please refer to its accompanying manual.
1.1. Slave Control(DMX Mode)
DecaLED Setup Tool Control Mode enables.
In this mode, the Dip Switch 11 (2 ) is flipped to the " "
position and R.G.B. output loading is set by default.
-digit Function Dip Switch ON
1
2
4
5
36
Group 1 Group 2
Color (R/G/B) Channel 1-6 / Group 1-2
Output 1 Output 2
Red
Blue
MODE-1 RGB mode (6 channels in total=2x3 channels)
2 RGB mode: has 2 groups with RGB output, of which each group consists of 3 channels(6 channels in total).
1
2
3
4
C&B
Color
Brightness
Group 1 Group 2
Channel 1-4 / Group 1-2
Output 1 Output 2
2 C&B mode: has 2 groups with color and intensity C&B output, of which each group consists of 2 channels
(4 channels in total).
MODE-2 Color and Brightness mode(4 channels in total=2x2 channels)
12
C&B
Color
Group 1 Group 2
Channel 1-2 / Group 1-2
Output 1 Output 2
100% 100%
Brightness
2 COLOR mode: has 2 groups with Color control, of which each group consists of 1 channel (2 channels in total).
The brightness is always 100% in this mode.
MODE-3 Color mode(2 channels in total=2x1 channels)
-Page 5-
In Slave Control, the settings for the addresses(001-512) and the Glide Effect
functions can be configured with DecaLED Setup Tool. There are 6 work modes
for Slave Control.
R
11
12
ON
OFF
1=
0=
DecaLED Setup Tool
(Sold separately)
R
R
R
R
3
Blue
MODE-4 Patch mode RGB of 2 outputs---->1 output(1x3 channels)
1 RGB mode: in this mode, 2 outputs are patched.
Channel 1-3
Group 1/
Output 1-2
Color (R/G/B)
1
Red
2
LED Setup Controller
www.decaled.com
R
A
T
E
REV FWD
Productcode:95350247
Setup Tool
Operation Guide:
1. DecaLED Setup Tool Control Mode-Programming
A LED Setup Tool (DecaLED Setup Tool) is required to program
DecaLED Controller 2 Mini for 12V RGB modules. For further information,
please refer to its accompanying manual.
1.1. Slave Control(DMX Mode)
DecaLED Setup Tool Control Mode enables.
In this mode, the Dip Switch 11 (2 ) is flipped to the " "
position and R.G.B. output loading is set by default.
-digit Function Dip Switch ON
1
2
4
5
36
Group 1 Group 2
Color (R/G/B) Channel 1-6 / Group 1-2
Output 1 Output 2
Red
Blue
MODE-1 RGB mode (6 channels in total=2x3 channels)
2 RGB mode: has 2 groups with RGB output, of which each group consists of 3 channels(6 channels in total).
1
2
3
4
C&B
Color
Brightness
Group 1 Group 2
Channel 1-4 / Group 1-2
Output 1 Output 2
2 C&B mode: has 2 groups with color and intensity C&B output, of which each group consists of 2 channels
(4 channels in total).
MODE-2 Color and Brightness mode(4 channels in total=2x2 channels)
12
C&B
Color
Group 1 Group 2
Channel 1-2 / Group 1-2
Output 1 Output 2
100% 100%
Brightness
2 COLOR mode: has 2 groups with Color control, of which each group consists of 1 channel (2 channels in total).
The brightness is always 100% in this mode.
MODE-3 Color mode(2 channels in total=2x1 channels)
-Page 5-
In Slave Control, the settings for the addresses(001-512) and the Glide Effect
functions can be configured with DecaLED Setup Tool. There are 6 work modes
for Slave Control.
R
11
12
ON
OFF
1=
0=
DecaLED Setup Tool
(Sold separately)
R
R
R
R
3
Blue
MODE-4 Patch mode RGB of 2 outputs---->1 output(1x3 channels)
1 RGB mode: in this mode, 2 outputs are patched.
Channel 1-3
Group 1/
Output 1-2
Color (R/G/B)
1
Red
2
LED Setup Controller
www.decaled.com
R
A
T
E
REV FWD
Productcode:95350247
Setup Tool
Operation Guide:
1. DecaLED Setup Tool Control Mode-Programming
A LED Setup Tool (DecaLED Setup Tool) is required to program
DecaLED Controller 2 Mini for 12V RGB modules. For further information,
please refer to its accompanying manual.
1.1. Slave Control(DMX Mode)
DecaLED Setup Tool Control Mode enables.
In this mode, the Dip Switch 11 (2 ) is flipped to the " "
position and R.G.B. output loading is set by default.
-digit Function Dip Switch ON
1
2
4
5
36
Group 1 Group 2
Color (R/G/B) Channel 1-6 / Group 1-2
Output 1 Output 2
Red
Blue
MODE-1 RGB mode (6 channels in total=2x3 channels)
2 RGB mode: has 2 groups with RGB output, of which each group consists of 3 channels(6 channels in total).
1
2
3
4
C&B
Color
Brightness
Group 1 Group 2
Channel 1-4 / Group 1-2
Output 1 Output 2
2 C&B mode: has 2 groups with color and intensity C&B output, of which each group consists of 2 channels
(4 channels in total).
MODE-2 Color and Brightness mode(4 channels in total=2x2 channels)
12
C&B
Color
Group 1 Group 2
Channel 1-2 / Group 1-2
Output 1 Output 2
100% 100%
Brightness
2 COLOR mode: has 2 groups with Color control, of which each group consists of 1 channel (2 channels in total).
The brightness is always 100% in this mode.
MODE-3 Color mode(2 channels in total=2x1 channels)
-Page 5-
In Slave Control, the settings for the addresses(001-512) and the Glide Effect
functions can be configured with DecaLED Setup Tool. There are 6 work modes
for Slave Control.
R
11
12
ON
OFF
1=
0=
DecaLED Setup Tool
(Sold separately)
R
R
R
R
3
Blue
MODE-4 Patch mode RGB of 2 outputs---->1 output(1x3 channels)
1 RGB mode: in this mode, 2 outputs are patched.
Channel 1-3
Group 1/
Output 1-2
Color (R/G/B)
1
Red
2
LED Setup Controller
www.decaled.com
R
A
T
E
REV FWD
Productcode:95350247
Setup Tool

MODE-5 Patch mode C&B of 2 outputs---->1 output (1x2 channels)
1 C&B mode: has 1 group with C&B output, which consists of 2 outputs that are controlled by 1 channels
(2 channels in total).
MODE-6 Patch mode colour of 1 output ---->1 output (1x1 channel)
1 COLOR mode: has1group with colour control, which consists of 2 outputs that are controlled by 1 channel
(1 channel in total). The brightness is always 100% in this mode.
Note:
The ‘Glide’ Effect function can be switched on(YES) or off(NO). The transition from one level to another is1.
smoother when this function is switched on.
When this function is switched off, the lighting intensity will be changed from one level to another instantly. 2.
Thus, when a quick lighting effect is required, the ‘Glide’ effect function should be switched off.
If the DMX signal is interrupted, the driver will keep the last received DMX signal(information) until the driver3.
is switched off or a new and valid DMX signal is sent.
When in link, the Slave will follow the Master, all parameter settings of each slave connected unit will be 4.
of no effect.
1.2.Master Control
AUTO mode and MANUAL mode are for Master Control. Relevant functions are as below:
AUTO mode:1.
Preset programs:1-10 programs and “AUTO” program (“AUTO”program is the sequential running of these
presets.)
Auto Speed: 1~100. Auto Fadetime: 0%~100%.
MANUAL mode:2. BLUE Dimmer: 0%~100%., RED Dimmer: 0%~100%., GREEN Dimmer: 0%~100%.
Note:
The LEDs will light up red in Slave Control mode. The LEDs will give respond smoothly when the parameters1.
are adjusted in Master Control.
If the LED is not selected in “Setup with answer”, it will light up red. If the LED is not selected in “Setup no 2.
answer”, it will switch off.
When the user conrms the settings of the LED products, the LEDs will strobe momentarily to conrm that the
setting have been saved.
1 C&B mode: has 1 group with C&B output, of which group consists of 2 outputs that are controlled by 1
channel(2 channels in total).
1
2
C&B
Color
Brightness
Group 1/
Output 1-2
Channel 1-2
1 COLOR mode: has 1 group with Color control. The brightness is always 100%, of which group consists of 2
outputs that are controlled by 1 channel(1 channel in total). The brightness is always 100% in this mode.
100%
1
C&B
Color
Brightness
Group 1/
Output 1-2
Channel 1
MODE-5 Patch mode C&B of 2 outputs---->1 output(1x2 channels)
MODE-6 Patch mode Color of 1 output---->1 output(1x1 channel)
NOTE:
1).The Glide Effect function can be switched on(YES) or off(NO). The transition from one level to another is
smoother when this function is switched on.
2).When this function is switched off, the lighting intensity will changed from one level to another abruptly.(thus,
when a quick lighting effect is required, the Guide Effect function should be switched off.)
3).If the DMX signal is interrupted, the driver will keep the last received DMX signal(information) until the driver
is switched off or a new and valid DMX signal is sent.
4).When in link, the Slave will follow the Master, all parameter settings of each slave connected unit will be of
no effect.
1.2.Master Control
(1) AUTO mode:
(2) MANUAL mode:
AUTO mode and MANUAL mode are for Master Control. Relevant functions are as below:
Preset programs:1-10 programs and "AUTO" program ( program is the sequential
running of these1-10 programs.)
"AUTO"
Auto Speed: 1~100. Auto Fadetime: 0%~100%.
Blue/ Duration: 0%~100%. Red/Speed: .0%~100% Green/Dimmer: .0%~100%
NOTE:
1).The LEDs will turn red in Slave Control mode.
The LEDs will give responding sensitive when the parameters are adjusted in Master Control.
2).If the LED is not selected in "Setup with answer", it will turn red.
If the LED is not selected in "Setup no answer", it will switch off.
When the user confirms the settings of the LED products, the LEDs will flash momentarily to confirm that the
setting have been saved.
-Page 6-
1 C&B mode: has 1 group with C&B output, of which group consists of 2 outputs that are controlled by 1
channel(2 channels in total).
1
2
C&B
Color
Brightness
Group 1/
Output 1-2
Channel 1-2
1 COLOR mode: has 1 group with Color control. The brightness is always 100%, of which group consists of 2
outputs that are controlled by 1 channel(1 channel in total). The brightness is always 100% in this mode.
100%
1
C&B
Color
Brightness
Group 1/
Output 1-2
Channel 1
MODE-5 Patch mode C&B of 2 outputs---->1 output(1x2 channels)
MODE-6 Patch mode Color of 1 output---->1 output(1x1 channel)
NOTE:
1).The Glide Effect function can be switched on(YES) or off(NO). The transition from one level to another is
smoother when this function is switched on.
2).When this function is switched off, the lighting intensity will changed from one level to another abruptly.(thus,
when a quick lighting effect is required, the Guide Effect function should be switched off.)
3).If the DMX signal is interrupted, the driver will keep the last received DMX signal(information) until the driver
is switched off or a new and valid DMX signal is sent.
4).When in link, the Slave will follow the Master, all parameter settings of each slave connected unit will be of
no effect.
1.2.Master Control
(1) AUTO mode:
(2) MANUAL mode:
AUTO mode and MANUAL mode are for Master Control. Relevant functions are as below:
Preset programs:1-10 programs and "AUTO" program ( program is the sequential
running of these1-10 programs.)
"AUTO"
Auto Speed: 1~100. Auto Fadetime: 0%~100%.
Blue/ Duration: 0%~100%. Red/Speed: .0%~100% Green/Dimmer: .0%~100%
NOTE:
1).The LEDs will turn red in Slave Control mode.
The LEDs will give responding sensitive when the parameters are adjusted in Master Control.
2).If the LED is not selected in "Setup with answer", it will turn red.
If the LED is not selected in "Setup no answer", it will switch off.
When the user confirms the settings of the LED products, the LEDs will flash momentarily to confirm that the
setting have been saved.
-Page 6-

2. Full DMX control mode
In this mode, the Dip Switch 3(4-digit function Dip Switch) is ipped to
the “OFF” position, the Dip Switch 10(10-digit addressing Dip Switch)
is to the “ON” position. And these switches are used to activate
special functions of attached xtures.
DMX Addressing
DMX is short for Digital Multiplex. This is a universal binary language used as a form of communication between
intelligent xtures. Each Dip Switch(10-digit Addressing Dip Switch) represents a binary value.
A DMX value(address) is set by combining the different dipswitches that will add up to the value you wish to
achieve, for example:
Remark:
In DMX Mode one output with R.G.B. Is controlled by three channels separately. And the Red effect is controlled
by Channel1, the Green effect is controlled by Channel 2 and the Blue effect is controlled by Channel3.
-Page 7-
2.Full DMX Control Mode
DMX is short for Digital Multiplex. This is a universal binary language used as a form of communication between
intelligent fixtures. Each Dip Switch(10-digit Addressing Dip Switch) represents a binary value.
A DMX value(address) is set by combining the different dipswitches that will add up to the value you wish to achieve,
for example: Setting DMX address for 21.
Flip switches1,3,&5 to the
"ON" position
Setting DMX address for 201.
Flip switches1,4,7,& 8 to the
"ON" position
Dipswitches# Value
1=1
3=4
5=16
=21
Dipswitches# Value
1=1
4=8
7=64
8=128
=201
In this mode, the Dip Switch 11(2 )
is flipped to the " " position, the Dip Switch 10(
) is to the " " position. And these
switches sometimes used to activate a fixture special functions.
-digit function Dip Switch
OFF 10-digit
addressing Dip Switch ON
Dip Switch 1 address equals 1
Dip Switch 2 address equals 2
Dip Switch 3 address equals 4
Dip Switch 4 address equals 8
Dip Switch 5 address equals 16
Dip Switch 6 address equals 32
Dip Switch 7 address equals 64
Dip Switch 8 address equals 128
Dip Switch 9 address equals 256
1,2,4
3,4
1,3,4
2,3,4
1,2,3,4
1
2
1,2
3
1,3
2,3
1,2,3
4
1,4
2,4
SWITCHES ON SWITCHES ON
START
CH#
START
CH#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
..
..
..
..
..
..
1 2 3 4 5 6 7 8 9 10
ON
OFF
1=
0=
511 1,2,3,4,5,6,7,8,9
ON
OFF
1=
0=
(10-digit Addressing Dip Switch)
123456789 10 11 12
..
..
Remark:
In , one output with R.G.B. Is controlled by three channels separately. And the Red effect is controlled
by Channel1, the Green effect is controlled by Channel 2 and the Blue effect is controlled by Channel3.
DMX Mode
DMX Addressing
-Page 7-
2.Full DMX Control Mode
DMX is short for Digital Multiplex. This is a universal binary language used as a form of communication between
intelligent fixtures. Each Dip Switch(10-digit Addressing Dip Switch) represents a binary value.
A DMX value(address) is set by combining the different dipswitches that will add up to the value you wish to achieve,
for example: Setting DMX address for 21.
Flip switches1,3,&5 to the
"ON" position
Setting DMX address for 201.
Flip switches1,4,7,& 8 to the
"ON" position
Dipswitches# Value
1=1
3=4
5=16
=21
Dipswitches# Value
1=1
4=8
7=64
8=128
=201
In this mode, the Dip Switch 11(2 )
is flipped to the " " position, the Dip Switch 10(
) is to the " " position. And these
switches sometimes used to activate a fixture special functions.
-digit function Dip Switch
OFF 10-digit
addressing Dip Switch ON
Dip Switch 1 address equals 1
Dip Switch 2 address equals 2
Dip Switch 3 address equals 4
Dip Switch 4 address equals 8
Dip Switch 5 address equals 16
Dip Switch 6 address equals 32
Dip Switch 7 address equals 64
Dip Switch 8 address equals 128
Dip Switch 9 address equals 256
1,2,4
3,4
1,3,4
2,3,4
1,2,3,4
1
2
1,2
3
1,3
2,3
1,2,3
4
1,4
2,4
SWITCHES ON SWITCHES ON
START
CH#
START
CH#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
..
..
..
..
..
..
1 2 3 4 5 6 7 8 9 10
ON
OFF
1=
0=
511 1,2,3,4,5,6,7,8,9
ON
OFF
1=
0=
(10-digit Addressing Dip Switch)
123456789 10 11 12
..
..
Remark:
In , one output with R.G.B. Is controlled by three channels separately. And the Red effect is controlled
by Channel1, the Green effect is controlled by Channel 2 and the Blue effect is controlled by Channel3.
DMX Mode
DMX Addressing
-Page 7-
2.Full DMX Control Mode
DMX is short for Digital Multiplex. This is a universal binary language used as a form of communication between
intelligent fixtures. Each Dip Switch(10-digit Addressing Dip Switch) represents a binary value.
A DMX value(address) is set by combining the different dipswitches that will add up to the value you wish to achieve,
for example: Setting DMX address for 21.
Flip switches1,3,&5 to the
"ON" position
Setting DMX address for 201.
Flip switches1,4,7,& 8 to the
"ON" position
Dipswitches# Value
1=1
3=4
5=16
=21
Dipswitches# Value
1=1
4=8
7=64
8=128
=201
In this mode, the Dip Switch 11(2 )
is flipped to the " " position, the Dip Switch 10(
) is to the " " position. And these
switches sometimes used to activate a fixture special functions.
-digit function Dip Switch
OFF 10-digit
addressing Dip Switch ON
Dip Switch 1 address equals 1
Dip Switch 2 address equals 2
Dip Switch 3 address equals 4
Dip Switch 4 address equals 8
Dip Switch 5 address equals 16
Dip Switch 6 address equals 32
Dip Switch 7 address equals 64
Dip Switch 8 address equals 128
Dip Switch 9 address equals 256
1,2,4
3,4
1,3,4
2,3,4
1,2,3,4
1
2
1,2
3
1,3
2,3
1,2,3
4
1,4
2,4
SWITCHES ON SWITCHES ON
START
CH#
START
CH#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
..
..
..
..
..
..
1 2 3 4 5 6 7 8 9 10
ON
OFF
1=
0=
511 1,2,3,4,5,6,7,8,9
ON
OFF
1=
0=
(10-digit Addressing Dip Switch)
123456789 10 11 12
..
..
Remark:
In , one output with R.G.B. Is controlled by three channels separately. And the Red effect is controlled
by Channel1, the Green effect is controlled by Channel 2 and the Blue effect is controlled by Channel3.
DMX Mode
DMX Addressing

3. Stand Alone (manual) mode
In this mode, the Dip Switch 3 (4-digit Function Dip Switch) is ipped to the “OFF” position, and the Dip Switch
10(10-digit Addressing Dip Switch) to the “OFF” position. Flip the dip-switch 1~3(10-digit Addressing Dip Switch)
to set up fade time, the dip-switch 4~6 (10-digit Addressing Dip Switch) to select chase speed and the dip-
switch 7~9 (10-digit Addressing Dip Switch) to select built-in 8 patterns. Their details can be referred to the
below table;
4. IR control mode with DecaLED®Control Remote
In this mode, the Dip Switch3 (4-digit Function Dip Switch) is ipped to the “OFF” position and Dip Switch4 to
the “ON” position. It allows to set up work modes and relative parameters by operating LED Remote.
Note:
The DecaLED®Controller 3 Mini is available in being controlled by selecting built-in IR sensor or external
connected IR EYE sensor. If the user want to select external connected IR EYE sensor, the IR EYE sensor should
be connected properly before operation.
4.1.Connecting an external connected IR EYE sensor to the DecaLED®Controller 3 Mini
4.1.1 Before connecting, please isolate the main power.
4.1.2 Plug the external connected IR EYE sensor into the external IR EYE connector correctly.
4.1.3 Turn the main power on.
Note:
Once you’ve conrmed all work modes and relative parameters, you can remove the external connected 1.
IR EYE sensor.
NEVER remove the external connected IR EYE sensor when powering on for preventing from the2.
damage.
4.2.Operation instructions
Before operation, make sure the batteries(3V, CR2025) have been installed properly.
There are 8 dedicated colour brightness pushbuttons (marked Red, Green, Blue, White, Cyan, Magenta,
Yellow, Amber). There are also the “AUTO” and the “UNIT SETTING” pushbuttons, as well as raise and lower keys
(marked “raise” and for “lower”) on the remote unit.
Detailed functions will be illustrated in the table on the next page.
4.2.Operation Instructions
4.2.1 Before operation, make sure the batteries(3V, CR2025) have been installed properly.
4.2.2 Operation Instructions
There are 8 dedicated color brightness keys(marked Red, Green, Blue, White, Cyan, Magenta, Yellow, Amber).
Also the "AUTO" and the "UNIT SETTING" keys, Up & Down keys(marked for "Up" and for "Down") are
on the remote controller as well.
The detailed functions are illustrated in the next table.
1).Once you've confirmed all work modes and relative parameters, you can remove the external connected IR EYE
sensor.
2).NEVER plug or unplug the external connected IR sensor when powering on for preventing from the damage.
Note:
LED Remote Cotroller
IR EYE Sensor
-Page 8-
3.Stand Alone(Manual)Mode
In this mode, the Dip Switch 11 (2 ) is flipped to the " " position, and the Dip Switch
10( ) to the " " position. Flip the dip-switch 1~3(10-digit Addressing Dip Switch)
to set up fade time, the dip-switch 4~6 (10-digit Addressing Dip Switch) to select chase speed and the dip-switch
7~9 (10-digit Addressing Dip Switch) to select built-in 8 patterns. Their details can be referred to the below table;
-digit Function Dip Switch OFF
10-digit Addressing Dip Switch OFF
"0" = "OFF" position
"1" = "ON" position.
000
100
010
110
001
101
011
111
0%
100%
123
14%
28%
43%
57%
71%
86%
ON
OFF
1=
0=
000
100
010
1
2
3
789
110
001
101
011
111
4
5
6
7
8
ON
OFF
1=
0=
11 12
2-digit Function Dip Switch
10-digit Addressing Dip Switch
1 2 3 4 5 6 7 8 9 10
456
000
100
010
110
001
101
011
111
0.2S
0.5S
1S
5S
10S
20S
30S
ON
OFF
1=
0=
0.1S
FADE TIME SPEED PROGRAM
4.IR Control Mode(with LED Remote Controller Operation)
In this mode, the Dip Switch11 (2 ) is flipped to the " " position and Dip Switch12 to
the " " position. It allows to set up work modes and relative parameters by operating LED Remote Controller.
-digit Function Dip Switch OFF
ON
Remark:
The DecaLED Controller 2 Mini for 12V is available in being controlled by selecting built-in IR sensor or external
connected IR EYE sensor. If the user want to select external connected IR EYE sensor, the IR EYE sensor should
be connected properly before operation.
11
12
2-digit Function Dip Switch
ON
OFF
1=
0=
R
R
4.
4.1.1 Before connecting, please isolate the main power.
4.1.2 Plug the external connected IR EYE sensor into the external IR connector correctly.
4.1.3 Thus, turn the main power on.
1.Connecting an external connected IR EYE sensor to the DecaLED Controller 2 Mini for 12V
3.Stand Alone(Manual)Mode
In this mode, the Dip Switch 3 (4-digit Function Dip Switch) is flipped to the "OFF" position, and the Dip Switch
10(10-digit Addressing Dip Switch) to the "OFF" position. Flip the dip-switch 1~3(10-digit Addressing Dip Switch)
to set up fade time, the dip-switch 4~6 (10-digit Addressing Dip Switch) to select chase speed and the dip-switch
7~9 (10-digit Addressing Dip Switch) to select built-in 8 patterns. Their details can be referred to the below table;
"0" = "OFF" position
"1" = "ON" position.
000
100
010
110
001
101
011
111
0%
100%
123
14%
28%
43%
57%
71%
86%
ON
OFF
1 =
0=
000
100
010
1
2
3
789
110
001
101
011
111
4
5
6
7
8
ON
OFF
1 =
0=
1234
4-digit Function Dip Switch
10-digit Addressing Dip Switch
12345678910
456
000
100
010
110
001
101
011
111
0.2S
0.5S
1S
5S
10S
20S
30S
ON
OFF
1 =
0=
0.1S
FADE TIME SPEED PROGRAM
4.IR Control Mode(with LED Remote Operation)
In this mode, the Dip Switch3 (4-digit Function Dip Switch) is flipped to the "OFF" position and Dip Switch4 to
the "ON" position. It allows to set up work modes and relative parameters by operating LED Remote.
4.2.Operation Instructions
4.2.1 Before operation, make sure the batteries(3V, CR2025) have been installed properly.
4.2.2 Operation Instructions
There are 8 dedicated color brightness pushbuttons(marked Red, Green, Blue, White, Cyan,
Magenta, Yellow, Amber). There are also the "AUTO" and the "UNIT SETTING" pushbuttons,
as well as Raise&Lower keys(marked for "raise" and for "lower") on the remote unit.
Their detailed functions will be illustrated in the next table.
LED Remote
4.1.Connecting an external connected IR EYE sensor to the DecaLED Controller 1 for RGB modules
4.1.1 Before connecting, please isolate the main power.
4.1.2 Plug the external connected IR EYE sensor into the external IR EYE connector correctly.
4.1.3 Thus, turn the main power on.
Note:
1).Once you've confirmed all work modes and relative parameters, you can remove the external connected IR EYE
sensor.
2).NEVER remove the external connected IR EYE sensor when powering on for preventing from the damage.
Remark:
The DecaLED Controller 1 for RGB modules is available in being controlled by selecting built-in IR sensor or
external connected IR EYE sensor. If the user want to select external connected IR EYE sensor, the IR EYE sensor
should be connected properly before operation.
1234
4-digit Function Dip Switch
ON
OFF
1 =
0=
R
R
IR EYE Sensor
-Page 10-
4.2.Operation Instructions
4.2.1 Before operation, make sure the batteries(3V, CR2025) have been installed properly.
4.2.2 Operation Instructions
There are 8 dedicated color brightness keys(marked Red, Green, Blue, White, Cyan, Magenta, Yellow, Amber).
Also the "AUTO" and the "UNIT SETTING" keys, Up & Down keys(marked for "Up" and for "Down") are
on the remote controller as well.
The detailed functions are illustrated in the next table.
1).Once you've confirmed all work modes and relative parameters, you can remove the external connected IR EYE
sensor.
2).NEVER plug or unplug the external connected IR sensor when powering on for preventing from the damage.
Note:
LED Remote Cotroller
IR EYE Sensor
-Page 8-
3.Stand Alone(Manual)Mode
In this mode, the Dip Switch 11 (2 ) is flipped to the " " position, and the Dip Switch
10( ) to the " " position. Flip the dip-switch 1~3(10-digit Addressing Dip Switch)
to set up fade time, the dip-switch 4~6 (10-digit Addressing Dip Switch) to select chase speed and the dip-switch
7~9 (10-digit Addressing Dip Switch) to select built-in 8 patterns. Their details can be referred to the below table;
-digit Function Dip Switch OFF
10-digit Addressing Dip Switch OFF
"0" = "OFF" position
"1" = "ON" position.
000
100
010
110
001
101
011
111
0%
100%
123
14%
28%
43%
57%
71%
86%
ON
OFF
1=
0=
000
100
010
1
2
3
789
110
001
101
011
111
4
5
6
7
8
ON
OFF
1=
0=
11 12
2-digit Function Dip Switch
10-digit Addressing Dip Switch
1 2 3 4 5 6 7 8 9 10
456
000
100
010
110
001
101
011
111
0.2S
0.5S
1S
5S
10S
20S
30S
ON
OFF
1=
0=
0.1S
FADE TIME SPEED PROGRAM
4.IR Control Mode(with LED Remote Controller Operation)
In this mode, the Dip Switch11 (2 ) is flipped to the " " position and Dip Switch12 to
the " " position. It allows to set up work modes and relative parameters by operating LED Remote Controller.
-digit Function Dip Switch OFF
ON
Remark:
The DecaLED Controller 2 Mini for 12V is available in being controlled by selecting built-in IR sensor or external
connected IR EYE sensor. If the user want to select external connected IR EYE sensor, the IR EYE sensor should
be connected properly before operation.
11
12
2-digit Function Dip Switch
ON
OFF
1=
0=
R
R
4.
4.1.1 Before connecting, please isolate the main power.
4.1.2 Plug the external connected IR EYE sensor into the external IR connector correctly.
4.1.3 Thus, turn the main power on.
1.Connecting an external connected IR EYE sensor to the DecaLED Controller 2 Mini for 12V

Pushbuttons & Keys Functions
NOTE:
The built-in presets consist of 1~10 patterns plus a sequence of 10 patterns.1.
There are 10 different optional levels for chase speed;2.
Fade time is available from 0% to 100%, 11 levels in total, 10% per level.3.
Effective distance from IR sensor to the DecaLED4. ®Control Remote is limited to about 10m.
Pushbuttons&Keys Functions
RED pushbutton
GREEN pushbutton
BLUE pushbutton
CYAN pushbutton
MAGENTA pushbutton
YELLOW pushbutton
WHITE pushbutton
AMBER pushbutton
AUTO pushbutton
UNIT SETTING pushbutton
PATTERN/RED key
PATTERN/RED key
SPEED/GREEN key
SPEED/GREEN key
FADE/BLUE key
FADE/BLUE key
BRIGHTNESS key
BRIGHTNESS key
Red, 100% brightness
Green, 100% brightness
Blue, 100% brightness
Cyan, 100% brightness
Magenta, 100% brightness
Yellow, 100% brightness
White, 100% brightness
Amber, 100% brightness
The color is changing automatically, and the brightness is 100%.
To cancel the LED remote settings. All settings will be done by flipping
dip-switches.
To select the next pattern or increase the red brightness, and holding it down,
the brightness will increase continuously until up to the maximum.
To select the previous pattern or decrease the red brightness, and holding it down,
the brightness will increase continuously until up to the minimum.
To increase the speed or the green brightness, and holding it down, it will
increase continuously until up to the maximum.
To decrease the speed or the green brightness, and holding it down, it will
increase continuously until up to the minimum.
To increase the fade time or the blue brightness, and holding it down, it will
increase continuously until up to the maximum.
To decrease the fade time or the blue brightness, and holding it down, it will
decrease continuously until up to the minimum.
To increase the overall brightness, and holding it down, it will increase
continuously until up to the maximum.
To decrease the overall brightness, and holding it down, it will increase
continuously until up to the minimum.
NOTE:
1.The built-in patterns consists of 1~10 patterns plus a sequence of 10 patterns.
2.There are optional 10 different levels for chase speed;
Speed
Time
10
1S
9
2S
8
4S
7
8S
6
16S
54321
32.5S 65S 130S 260S 512S
3.And fade time is available from 0% through 100%, total 11levels, 10% per level.
-Page 11-
4.Effective distance from IR sensor to LED Remote shall be limited within the range of 10m. Otherwise, it
results out of control.
Pushbuttons&Keys Functions
RED pushbutton
GREEN pushbutton
BLUE pushbutton
CYAN pushbutton
MAGENTA pushbutton
YELLOW pushbutton
WHITE pushbutton
AMBER pushbutton
AUTO pushbutton
UNIT SETTING pushbutton
PATTERN/RED key
PATTERN/RED key
SPEED/GREEN key
SPEED/GREEN key
FADE/BLUE key
FADE/BLUE key
BRIGHTNESS key
BRIGHTNESS key
Red, 100% brightness
Green, 100% brightness
Blue, 100% brightness
Cyan, 100% brightness
Magenta, 100% brightness
Yellow, 100% brightness
White, 100% brightness
Amber, 100% brightness
The color is changing automatically, and the brightness is 100%.
To cancel the LED remote settings. All settings will be done by flipping
dip-switches.
To select the next pattern or increase the red brightness, and holding it down,
the brightness will increase continuously until up to the maximum.
To select the previous pattern or decrease the red brightness, and holding it down,
the brightness will increase continuously until up to the minimum.
To increase the speed or the green brightness, and holding it down, it will
increase continuously until up to the maximum.
To decrease the speed or the green brightness, and holding it down, it will
increase continuously until up to the minimum.
To increase the fade time or the blue brightness, and holding it down, it will
increase continuously until up to the maximum.
To decrease the fade time or the blue brightness, and holding it down, it will
decrease continuously until up to the minimum.
To increase the overall brightness, and holding it down, it will increase
continuously until up to the maximum.
To decrease the overall brightness, and holding it down, it will increase
continuously until up to the minimum.
NOTE:
1.The built-in patterns consists of 1~10 patterns plus a sequence of 10 patterns.
2.There are optional 10 different levels for chase speed;
Speed
Time
10
1S
9
2S
8
4S
7
8S
6
16S
54321
32.5S 65S 130S 260S 512S
3.And fade time is available from 0% through 100%, total 11levels, 10% per level.
-Page 11-
4.Effective distance from IR sensor to LED Remote shall be limited within the range of 10m. Otherwise, it
results out of control.

Troubleshooting
The DecaLED®Controller 3 Mini does nothing.
Check that the device is connected to the socket via the supplied power cord and that it is switched•
on.
Check that the red light on the power switch on the backside of the device is turned on. If not, remove the•
device from the socket and change the fuse. This is located under a small lid near the power adapter.
Check that the Power LED is on. If not, return the device.•
The DecaLED®Controller 3 Mini does not respond to DMX.
Check that the DMX control LED is on.•
If the control LED is not on, check that DMX is present and/or that the connector is connected correctly. •
Check that the DMX addresses have been set correctly by means of the DecaLED• ®Setup Tool.
The connected DecaLED®24V products do not respond.
Check that the output cables and all connections have been connected correctly. If necessary, remove•
all outputs except 1.
Only a maximum loading capacity of 3A(1A per individual channel) is allowed on a single output and the•
maximum amount of the total load can not exceed 4A distributed over all 2 outputs.
The DecaLED®Controller 3 Mini cannot be programmed.
Remove the DMX signal when connecting the DecaLED• ®Setup Tool.
Check the DecaLED• ®Setup Tool and its cables and connections.
Check the batteries or connect the supplied power supply to the DecaLED• ®Setup Tool.
If you cannot nd a cause for a defect, we advise you to contact your supplier. Leave repairs to professionals.
Never try to repair the device yourself, as this could inuence your warranty.
Info: www.lagotronics.com
This manual suits for next models
1
Table of contents
Other DecaLED Controllers manuals
Popular Controllers manuals by other brands

Victron energy
Victron energy BlueSolar MPPT 75/10 manual

Emerson
Emerson Tescom 44-3400 Series Instructions for use

Matelec
Matelec FPC-15007-CON Owner's operation

AAON
AAON Orion VCCX2 Technical guide

VALPES
VALPES VRX25 TECHNICAL LITERATURE SET UP PROCEDURE

Bray
Bray Series 70 Operation and maintenance manual