DEEP GLOW Underwater Lighting System User manual

Lighting System General Operation
— Patent #7591564 —
Congratulations on the purchase of your new underwater light. Deep Glow Technologies takes pride in providing well designed,
high quality and thoroughly tested products that allow you to enhance the enjoyment of your waterfront.
Safety Information:
READ ALL INSTRUCTIONS BEFORE INSTALLING. NEVER TRY TO INSTALL OR REMOVE PRODUCT WHILE
POWER IS CONNECTED. UNDER NO CIRCUMSTANCE SHOULD THIS LIGHT BE DEPLOYED IN A POOL OR
SPA. UNDER NO CIRCUMSTANCE SHOULD THE LIGHT BE OPERATED ABOVE WATER. LOOKING DIRECTLY
INTO THE LIGHT ABOVE WATER CAN CAUSE DAMAGE TO THE EYE. THIS LIGHT MUST BE PLUGGED INTO
A GFCI PROTECTED OUTLET. NEVER PLUG INTO AN UNPROTECTED OUTLET. UNDER NO CIRCUMSTANCE
SHOULD THE LIGHT CABLE BE SPLICED TOGETHER. DO NOT SWIM NEAR THE LIGHTS DURING OPERATION.
THE OPERATING CONDITION OF ALL PRODUCT COMPONENTS AND ELECTRICAL CABLING SHOULD BE
VISUALLY INSPECTED PERIODICALLY. IF YOU HAVE ANY CONCERNS ABOUT THE SAFETY OF THIS PRODUCT,
DISCONNECT POWER AND CALL DEEP GLOW FOR ASSISTANCE.
General Operating Information:
• Deep Glow lights consume 2 amps of power. Other devices which draw from the same circuit may affect the number of
lights that can be operated. For example, operation of a boat lift on the same circuit may result in a temporary interruption
in the operation of the light
• Allow for a 15 minute interval before restarting the light.
• This product is intended for use in both saltwater and freshwater.
• The commercial materials used in this product will provide robust and reliable operation under normal operating conditions.
• The light is designed to be deployed by tossing or lowering into no less than three feet of water.
• Lights must remain submerged at all times while operating
•
Depending upon water clarity, depth and lighting conditions, the diameter of light can range from approximately 15 to 30 feet.
Maintenance:
We recommend the light(s) be operated for a minimum of 8 hours daily to ensure optimal performance.
Lights can be installed in lakes and ponds that freeze over, as long as they stay operational during the freezing periods.
Growth may occur on the light housing, around the lens flange and on the cable; this is normal and should not affect performance.
However, in some areas of heavy growth, growth may occur on the lens itself. If you are operating the light in an aggressive growth
area, cleaning may be necessary every 90 days. Always unplug the unit prior to cleaning. Light marine growth should be removed
from the lens using a stiff or metal brush. If heavier barnacle growth occurs, remove with a metal chisel or spackle knife.
Do not soak
in degreasers or citrus type cleaners. Do not get bottom paint on stainless bolts and wingnuts.
We are happy to assist you with questions regarding maintaining your light. Replacement parts and bulbs are readily available from the
factory. For optimum performance, bulbs should be replaced every two years. Do not handle the bulb with bare hands, as the oils may
damage the bulb.
Troubleshooting:
Please contact our technical support staff toll free at (888) 871-3334, extension 2, Monday through Friday from 9:00 am to 5:00 pm EST.
Warranty:
We truly want you to enjoy this product for many years and are here to support you. Please contact us if your light does not work
as expected. Deep Glow Technologies warrants this product to be free from defects in workmanship and materials for a period of
two years from the date of original purchase. Misuse, abuse, improper installation, neglect, improper shipping, damage caused by
disasters such as fire, flood and lightning, unauthorized repair or modifications will void said warranty. Should your product prove
defective during the warranty period, promptly contact Deep Glow Technologies for an RMA number and then return the
product with the RMA number clearly marked on the outside of the shipping container.
Phone: 727.234.1334 • Fax: 727.234.1335 • Toll Free: 888.871.3334
www.DeepGlow.com V.9.7.16

Flange
Wing
Nuts
Lens
O-Ring
Bulb
Light
Socket
Light
Housing
Office Mailing Address: PO Box 55055, St Petersburg, FL 33732
Warehouse Shipping Address: 13101 56th Court, Suite #811, Clearwater, FL 33760
Phone: 727.234.1334 • Fax: 727.234.1335 • Toll Free: 888.871.3334
www.DeepGlow.com
Deep Glow Technologies, Inc.
Lighting System Specifics
— Patents #7,591,564 and #8,123,372 —
Lower Unit Housing:
Dimensions:
Height 8" X Width 9"
Weight: 14Lbs.
Constructed with UL listed,
non-corrosive and
non-conductive
components/materials.
Bulb/Lamp:
150Watt Metal Halide Lamp
Over 10,000 Lumens
Available in Superior Colors:
Green, Blue, or Clear
Average Life of 5500 Hrs.
Inline GFCI Enclosure:
Dimensions:
7.2"L X 2.7"W X 2.7"H
Class A GFCI, 4-6 mA Trip Level
Rating: 125 VAC 60Hz, 15A
UL Listed for Outdoor Usage
LED Operation lndicator
Test and Reset Buttons
Operating System:
150W HID Electronic Ballast
Voltage: 120V to 240V AC nominal
Significant energy savings as compared
to magnetic ballasts.
Safety Shut Down Features
UL Type 1 Outdoor Ballast
Consumes 1.5 Amps

1. Please read Lighting System General Operation page before installing.
2. Choose an appropriate location by considering depth,
boat traffic and bottom surface material. (A)
3. Secure GFCI (B) and optional timer with supplied cable straps (C) well above
the highest potential water level.
GFCI must be installed vertically as shown.
4. Attach cable weight (D) to the cord as shown.
5. Toss or lower the light (E) into the water. The light is designed to land lens side up. In rocky areas,
the light should be lowered and placed carefully on the bottom. Light and cable
should never be placed in the potential path of a boat, without adequate clearance. (A)
6. Light should be plugged into a Ground Fault Circuit Interrupter (GFCI) Outlet. (F)
Under no circumstance should a light be installed on an unprotected outlet.
7. Allow a few minutes for the light to reach full brightness. The inline GFCI (B) is
equipped with a red indicator light. If the light is on, everything is working properly.
Do not submerge GFCI.
8. Enjoy!
F
GFCI
Dock
Outlet
B
Inline
GFCI Plug
Timer
optional
C
Cable
Straps
A
Boat
Clearance
E
Light
D
Cable
Weight
Please feel free to contact customer service at 727-234-1334 Ext. 2.
WARNING:
All power to the unit must be
disconnected during installation.
Do not plug in the unit until the
light is completely installed.
DeepGlow Installation Guide — Please read carefully.
Phone: 727.234.1334 • Fax: 727.234.1335 • Toll Free: 888.871.3334
www.DeepGlow.com
If you’re in an area with
musckrats, use conduit to
protect exposed cables.
V.7.25.14
Mount GFCI
at least 4'
above the
dock’s deck.
Table of contents
Popular Underwater Lighting manuals by other brands

Shadow-Caster
Shadow-Caster SCM-SNLC manual

OR STEEL light
OR STEEL light TALOS Technical manual

Sea & Sea
Sea & Sea YS-01 SOLIS instruction manual

Astral Pool
Astral Pool LumiPlus PAR56 DC Installation and maintenance manual

Astral Pool
Astral Pool SLX quick start guide

Keldan
Keldan CRI86 operating instructions

Kripsol
Kripsol PH300.C Manual for the installation, use and maintenance

Oase
Oase LunAqua Power LED Series operating instructions

MTS Systems
MTS Systems SSL 8053 manual

Nanight
Nanight Sport 2 user manual

RGBlue
RGBlue System 01/02:re instruction manual

lumishore
lumishore TIX 802 Installation and operating guide