DeRoyal Aqua-Box 1200-00 User manual

Aqua-Box®Owner’s Manual
Fluid Waste Evacuation & Disposal
Models: 1200-00, 1300-00, 1500-00 & 1300-R

Aqua-Box Owner’s Manual
2
GENERAL INFORMATION .......................................................3-6
About this Manual ............................................................................................................ 3
Introduction...................................................................................................................... 3
OSHA & EPA Considerations............................................................................................. 4
Sales & Distribution........................................................................................................... 4
Warranty Policy ............................................................................................................... 4-5
Model Comparison........................................................................................................... 6
TECHNICAL INFORMATION ....................................................7-8
Dimensions ...................................................................................................................... 7
Vacuum Source ................................................................................................................ 7
Unit Placement ................................................................................................................. 7
Evacuation Rate................................................................................................................ 7
Model 1500..................................................................................................... 7
Model 1300, 1200 & 1100.............................................................................. 7
Installation Requirements.................................................................................................... 8
Disinfectant Solution.......................................................................................................... 8
Power Switch/Timer (Models 1500 & 1300)....................................................................... 8
INSTALLATION........................................................................9-15
Packing List ...................................................................................................................... 9
Mounting the Unit............................................................................................................. 9
Plumbing Connections....................................................................................................... 10
Installation Diagrams: Plumbing Connections....................................................................... 11-12
Electrical Connections ....................................................................................................... 13-14
Installation Diagrams: Electrical Connections ....................................................................... 13-14
Adjusting the Automatic Timer Switch (Models 1500 & 1300) .............................................. 15
INSTRUCTIONS FOR USE ........................................................16-19
Non-Rinsing Units ............................................................................................................. 16-17
Rigid Canisters.................................................................................................. 16
Liner Systems .................................................................................................... 17
Rinsing Units .................................................................................................................... 18-19
Rigid Canisters.................................................................................................. 18
Liner Systems .................................................................................................... 19
Evacuation Tubes.............................................................................................................. 20
MAINTENANCE......................................................................20
TROUBLESHOOTING...............................................................21
REPLACEMENT PARTS..............................................................22-23
TABLE OF CONTENTS
www.deroyal.com 800.251.9864

Fluid Waste Evacuation & Disposal
www.deroyal.com 800.251.9864
3
ABOUT THIS MANUAL
This manual is designed to serve as both installation instructions
as well as usage instructions. It also includes maintenance and
troubleshooting information as well as a parts list for user
replaceable components.
This manual covers all the various models of Aqua-Box. If
a model number is not specified, then the text refers to all
models. If the first part of the model number only is specified,
then the text refers to any model with the same prefix. For
example, when referencing model number 1300, then the text
would be relevant to models 1300-00 and 1300-R.
When referencing “non-rinsing” units, then the text would be
relevant to 1500-00, 1300-00, 1200-00, and 1100-00 Models.
“Rinsing” unit would refer to the 1300-R Model.
INTRODUCTION
Medical waste is a 5 billion pound problem for hospitals and
surgery centers each year. Medical waste fluid generated during
surgery is a costly and growing concern for healthcare personnel
across the country. Due to technological advancements and
the popularity of endoscopic procedures, such as cystoscopy
and arthroscopy, there is a tremendous increase in the amounts
of potentially infectious waste fluid. As a result, disposal of the
medical waste fluids has become a financial burden for hospital
administrations. With increased efforts by the Environmental
Protection Agency and the American Hospital Association
to reduce waste, and the Occupational Safety and Health
Administration’s efforts to enforce Title 29, Part 1910.1030,
concerning healthcare personnel safety, DeRoyal realizes
that hospitals and surgery centers are in need of simple, cost-
effective and safe solutions for disposal of medical waste fluid.
Specifically designed to comply with OSHA Title 29, Part
1910.1030, concerning blood-borne pathogens, hospitals and
surgery centers can now eliminate red bag expenses with the
Aqua-Box, a simple but innovative waste fluid elimination
and disposal system. The Aqua-Box is a compact, stand-alone,
wall-mounted unit that optionally adds a disinfectant before
safely discarding the waste fluid down existing facility sewer
lines. The Aqua-Box empties and discards fluid from any
suction canister, liner, collection bag, kick bucket or any other
fluid collection source. The process is quick, efficient and safe.
Able to evacuate a standard suction canister in less than 30
seconds, the Aqua-Box has the fastest fluid disposal time in
the industry. Research has shown that suction canisters may
be changed as many as 40 times in one and a half to two-hour
procedure. Because of this high volume handling of waste
fluid, the chance of spills and personnel exposure to potentially
infectious blood-borne pathogens increases dramatically.
Hospital and surgery center liability can extend for as long as 30
years when personnel contamination occurs. With the Aqua-
Box, the risks associated with transportation of the canisters
to distant locations for disposal are virtually eliminated. In
most cases, the Aqua-Box pays for itself in less than four
months by saving hospitals and surgery centers thousands of
dollars associated with red bag disposal fees. And because the
Aqua-Box offers a safer alternative for handling the potentially
infectious fluids, hospitals and surgery centers can expect fewer
GENERAL INFORMATION

4
Aqua-Box Owner’s Manual
www.deroyal.com 800.251.9864
liabilities creating even more bottom line savings. Optionally,
a disinfectant can be added to the evacuated waste fluid,
making for an even safer disposal process.
The Aqua-Box can be installed in just about any wall-
mounted location, thus not consuming any valuable floor
space. For location convenience, the Aqua-Box can be placed
in areas near the operating room, central processing, labor and
delivery and the emergency department.
Due to its simple operation, space saving design, low
maintenance requirements and potential cost savings, the
Aqua-Box is becoming the standard for waste fluid disposal.
OSHA & EPA CONSIDERATIONS
OSHA has issued a regulation titled OSHA Regulations
(Standards – 29 CFR) Bloodborne Pathogens. – 1910–1030
that spells out the manner in which staff members are
to handle medical waste fluid as well as other potentially
infectious waste. In November of 1999, a compliance directive
titled CPL 2–2.44d was issued that requires employers to “...
update their Bloodborne Pathogen Exposure Control Plan to
document consideration and implementation of ‘safer medical
devices.’ Employers are also required to use engineering
and work practice controls that eliminate occupational
exposure, or reduce it to the lowest feasible extent, through
a comprehensive program including engineering controls (i.e.
the use of ‘safer medical devices’) and proper work practices.
Employers must provide training to all employees in the use
of these safer medical devices.
SALES & DISTRIBUTION
Aqua-Box and Aqua-Box accessories are sold exclusively
direct through DeRoyal.
WARRANTY POLICY
Limited Warranty
The Aqua-Box (all models) is covered under a three-year parts
& labor warranty. For three years from the date of purchase
(invoice date) by the original owner, DeRoyal will, at its
option, repair or replace any part of the unit, which proves to
be defective in material or workmanship under normal use.
During this period DeRoyal will provide all parts and labor
necessary to correct such defects free of charge, so long as the
unit has been installed and operated in accordance with the
written instructions in this manual. If there is a unit failure
that cannot be resolved by phone, by a visit by a DeRoyal
representative, or by a sub-contracted plumber during the
warranty period, DeRoyal will ship a replacement unit.
This warranty is in lieu of any other warranties and conditions
express or implied, including warranties of merchantability and
fitness for any other particular purpose. The obligations under
this warranty are exclusive and DeRoyal assumes or authorizes
no one to assume for them any other obligations.
This warranty gives the original owner specific legal rights,
and you may also have other rights, which vary from state to
state.
Items Not Covered
• Incidental or consequential damages.
• Service calls that do not involve defects in material
or workmanship such as customer education or improper
installation, including low water inlet flow of less than 12
GPM.
• Service calls involving a clogged unit that can be resolved
with the backwash procedure or clogged drains past the
unit discharge.

www.deroyal.com 800.251.9864
5
Fluid Waste Evacuation & Disposal
• Standard maintenance and cleaning of the unit.
• Service calls that are related to external problems, such as
abuse, misuse, inadequate electrical power, inadequate water
flow, accidents, fire, floods, or acts of God.
• Replacement of fuses or resetting circuit breakers.
• Failure of the product if it is used for other than its intended
purpose.
• Parts and labor costs for the following will not be considered
as warranty items as these are considered “normal wear” items
and are user replaceable:
o Thumb Valve
o Suction Hose
o Suction Hose Check Valve
o Disinfectant Hose
o Disinfectant Ball Valve
o Disinfectant Hose Fitting
o Suction Hose Hanger
o Suction Hose Adapters
o Reduced Pressure Zone (RPZ) valve
• This warranty does not apply outside the USA.
Extended Warranty
A three-year extension for all Aqua-Box models is available for an
additional charge. Contact your DeRoyal Sales Representative
for additional information.
The Aqua-Box must be installed per specifications
for the warranty to be valid. The proper amount
of water flow (see spec) and the correct electrical
supply (see spec) must be provided. For example,
if the specification calls for 12 gallons per minute,
the Aqua-Box will not work effectively with less
flow and may result in clogging of the unit. The
electrical will need to be 120 volts, the Aqua-Box
will not work properly with 12 volts or 220 volts;
connect as per the specifications.

Aqua-Box Owner’s Manual
6
www.deroyal.com 800.251.9864
DEROYAL AQUA-BOX MODEL COMPARISON
Feature
Automatic with
Canister Rinsing
Large
Automatic
Small
Automatic
Small
Manual
Small
Manual
Model # 1300-R 1500-00 1300-00 1200-00 1100-00
Fluid Evacuation Flow Rate (# seconds/liter) 3.5 seconds
3.5 seconds
3.5 seconds
6 seconds 8 seconds
Adjustable Canister Rinsing Cycle Yes No No No No
Automatic Adjustable Electronic On/Off Switch Yes Yes Yes No No
Works with Any Brand/Style Canister Yes Yes Yes Yes Yes
Disinfectant Solution Additive Yes Yes Yes Yes No
Suction Hose 5 Feet 5 Feet 5 Feet 5 Feet 5 Feet
Inlet
3/4“ tap water
@ 12 GPM
3/4” tap water
@ 12 GPM
3/4“ tap water
@ 12 GPM
3/4“ tap water
@ 12 GPM
1/2“ tap water
@ 12 GPM
Outlet 1” drain 1” drain 3/4” drain 3/4” drain 3/4” drain
Installation Instructions & Video Included Included Included Included Included
Reduced Pressure Zone (RPZ) Valve Yes Yes Yes Yes No
Dimensions (H” x W” x D”) 18” x 16” x 10” 14” x 16” x 6” 12” x 14” x 6” 12” x 14” x 6” 8” x 12” x 7”
Unlimited Phone Technical Support (Business Hours) Yes Yes Yes Yes Yes
Warranty (Parts & Labor) 3 Years 3 Years 3 Years 3 Years 3 Years
Extended 3-Year Warranty Available Available Available Available Available
Patented Technology
Patent #
7,273,585
Patent #
7,273,585
Patent #
7,273,585
Patent #
7,273,585
Patent #
7,273,585

Fluid Waste Evacuation & Disposal
www.deroyal.com 800.251.9864
7
DIMENSIONS
TECHNICAL INFORMATION
VACUUM SOURCE
The Aqua-Box generates its own vacuum by utilizing water
flow through the unit.
UNIT PLACEMENT
The Aqua-Box wall mounts easily near hoppers or sinks in
workrooms, dirty utility rooms or on any wall containing
water and sewer lines. The unit(s) can be mounted in surgery
suites and used for liquid clean up on the floors using the
Puddle Guppy™.
EVACUATION RATE
Model 1500 & 1300
A 3-liter canister will evacuate directly into sewer lines in
approximately 10.5 seconds. A 16-liter Omni-Jug® will
evacuate directly into sewer lines in approximately 56
seconds.
Model 1200
A 3-liter canister will evacuate directly into sewer lines in
approximately 13.5 seconds. A 16-liter Omni-Jug
®
will
evacuate directly into sewer lines in approximately 72
seconds.
Model 1100
A three liter canister will evacuate directly into the sewer
lines in approximately 15 seconds. A 16 liter Omni-Jug
®
will evacuate directly into sewer lines in approximately 80
seconds.
1300-R 1500-00 1300-00 1200-00 1100-00
Controller Box
(all models)
Width
18 in.
(45.7 cm)
16 in.
(40.6 cm)
14 in.
(35.6 cm)
14 in.
(35.6 cm)
12 in.
(30.5 cm)
7 in.
(17.8 cm)
Height
16 in.
(40.6 cm)
14 in.
(35.6 cm)
12 in.
(30.5 cm)
12 in.
(30.5 cm)
8 in.
(20.3 cm)
7 in.
(17.8 cm)
Depth
10 in.
(25.4 cm)
6 in.
(15.2 cm)
7 in.
(17.8 cm)
7 in.
(17.8 cm)
7 in.
(17.8 cm)
6 in.
(15.2 cm)
Weight
21 lbs
(9.5 kg)
17 lbs.
(7.7 kg)
10lbs.
(4.5 kg)
10 lbs.
(4.5 kg)
9 lbs.
(4.0 kg)
3 lbs.
(1.4 kg)

Aqua-Box Owner’s Manual
8
www.deroyal.com 800.251.9864
INSTALLATION REQUIREMENTS
A standard 110/120 AC Volt, 15/60-Hertz cycle, 3 Amp
electrical outlet is required for the power switch for the 1500
and 1300 Models; no electricity is required for Model 1200
or 1100. A unit can typically be installed in less than three
hours, including plumbing by the in-house biomedical or
maintenance department.
For 1500, 1300 & 1200 Models, a 3/4” water line with a
minimum flow rate of 12 gallons per minute at 30 PSI is
required for optimal performance. For Model 1100, a 1/2”
water line with a minimum flow rate of 12 gallons per minute
at 30 PSI is required for optimal performance. Smaller pipes
or slower flow rates will result in longer evacuation times.
Purchaser of the Aqua-Box is responsible for the installation of
the included RPZ (reduced pressure zone backflow preventer)
valve for the fresh water line. The Model 1100 does not come
with a back flow preventer.
DISINFECTANT SOLUTION
This feature has been added mainly to accommodate those
facilities that simply prefer to treat their fluid on their own
accord. This feature can be easily turned on or off. The ratio
of sodium hypochlorite (common household bleach) to waste
fluid is pre-set at 1,100 PPM (parts per million). The Model
1100 does not have a disinfectant solution inlet.
POWER SWITCH/TIMER
Models 1500-00 & 1300-00
The Aqua-Box power button is set to stay on for 2 minutes.
This pre-set time can be easily changed by the facility as
needed. A “kill” switch (the red button on the right side of
the electrical box) will turn off the unit prior to the end of the
timed cycle if desired.
Model 1300-R
The Aqua-Box power button is set to stay on for 5 minutes
This pre-set time can be easily changed by the facility as
needed. A “kill” switch (the red button on the right side of
the electrical box) will turn off the unit prior to the end of the
timed cycle if desired.
Model 1200-00 & 1100-00
These models do not have a power switch/timer.

Fluid Waste Evacuation & Disposal
www.deroyal.com 800.251.9864
9
INSTALLATION
The following procedures are important for correct mounting,
plumbing and electrical installation of the Aqua-Box. The
fluid disposal system is lightweight and can be mounted on
almost any wall with approximately drilled holes, anchors
and screws. For proper installation of the Aqua-Box, carefully
follow the instructions below.
PACKING LIST
(1) Aqua-Box Fluid Disposal System – Master Unit
(1) Automatic Control Box
(1500-00, 1300-00 & 1300-R Models only)
(1) 3/4” Electric Solenoid Valve
(1500-00 and 1300-00 Model only)
(1) RPZ (Reduced Pressure Zone) Valve
(except 1100-00 Model)
(1) 5 Foot Suction Hose with Thumb Valve
(1) 1/2” Valve and Hose for Disinfectant
(1) Tube of Thread Sealant
(1) Set of Screws and Wall Anchors
(5) Evacuation Tubes
MOUNTING THE UNIT: NON-RINSING MODELS
1. Models 1500, 1300 & 1200: Mount the Aqua-Box on the
wall no more than 5 feet off the floor (top of Aqua-Box) using
the #10 stainless steel screws and matching anchors provided
or by screwing directly into wall studs.
2. Models 1500 & 1300 only: Remove the cover of the
control box by unscrewing the four cover screws. Mount
the electrical control box on the wall at a position that is
comfortable, convenient and safe for staff with the #8 stainless
steel screws and matching anchors provided. The electrical
requirements are 110/120 AC Volts, 50/60-Hertz cycle, 3
Amps. Installation diagram follows. The Aqua-Box ships with
a standard heavy-duty 10 foot 110/120 Volt plug which may
be plugged directly into an electrical outlet. Optionally, it may
be hard wired. Replace the control box cover.
3. Model 1100: Remove the cover. There are four holes that
can be accessed through the box. Attach to wall approximately
five feet from floor to top of box using the #10 stainless steel
screws and matching anchors provided, or by screwing directly
into wall studs.
MOUNTING THE UNIT: RINSING MODELS
1. Mount the Aqua-Box Master Box on the wall such that
the top of the unit is 5 feet off the floor using the #10 stainless
steel screws and matching anchors provided or by screwing
directly into wall studs.
2. Remove the cover of the control box by unscrewing the
four cover screws. Mount the electrical control box on the
wall at a position that is comfortable, convenient and safe for
staff with the #8 stainless steel screws and matching anchors
provided. The black seal should give you a good guide for
placement. The electrical requirements are 110/120 Volt,
50/60-Hertz cycle, 3 amps. Installation diagram follows. The
Aqua-Box ships with a standard heavy-duty 10 foot 110/120
Volt plug which may be plugged directly into an electrical
outlet. Optionally, it may be hard wired. Replace the control
box cover.

Aqua-Box Owner’s Manual
10
www.deroyal.com 800.251.9864
PLUMBING CONNECTIONS: ALL UNITS
1. A 3/4” (1/2” for Model 1100) standard copper water
supply line will need to supply a minimum of 12 gallons per
minute at 30 psi (minimum). A 1” Reduced Pressure Zone
(RPZ) valve is included (except model 1100) and must be
installed with the system per local codes. The installation
diagram follows. The RPZ valve will need to be tested and
certified by a licensed plumber. For all plumbing connections,
especially the PVC connections, be sure to connect the fittings
securely. DO NOT OVERTIGHTEN FITTINGS!
2. Connect the 3/4” (1/2” for Model 1100) copper water
supply line to the inlet of the RPZ valve.
3. Connect a section of 3/4” (1/2” for Model 1100) copper
pipe to the outlet of the RPZ valve. It is recommended that
union fittings be used on either side of the RPZ valve so that
it can be easily removed should maintenance be required.
4. For 1500 & 1300 Models: Install the inlet of the electric
solenoid valve after the RPZ valve.
5. For 1500 & 1300 Models: Connect the outlet of the
electric solenoid valve to the inlet of the Aqua-Box. The
electric solenoid valve should now be mounted between the
RPZ valve and the Aqua-Box. Ensure the electric solenoid
valve flow arrows, markings are pointed towards the Aqua-
Box. Refer to Electrical Connections below for connecting
the wires of the electric valve.
6. For 1200 & 1100 Models: Connect the outlet of the RPZ
valve to the inlet of the Aqua-Box.
7. A 1” gate valve is supplied for backwashing. Union fittings
are recommended for ease of installation and removal should
maintenance be required. The 1”valve on the discharge side
of the unit should be mounted where employees will not be
closing it when not needed.
8. To insure maximum staff safety, the fluid discharge line from
the Aqua-Box should be plumbed directly to an existing sewer
line. Connect the outlet of the Aqua-Box using minimum 2”
sewer line with an outside vent, per the Southern Building
code. The discharge line can run back up above the Aqua-
Box into a sewer line running along the ceiling if necessary
(Please contact Aqua-Box Technical Support for this type of
installation). In this case, a check valve needs to be added to
prevent fluids from running back into the unit after it has been
turned off. As the Aqua-Box is sealed, a trap is not necessary,
but may be installed without issue.
9. The discharge line must be adequately vented. Failure to
do so may result in pressure buildup in discharge line causing
fluid waste to flow back into the Aqua-Box. A minimum 2”
drain and vent is needed.

Fluid Waste Evacuation & Disposal
www.deroyal.com 800.251.9864
11
INSTALLATION DIAGRAM: PLUMBING CONNECTIONS
Applies to 1500 & 1300 Models
™

12
Aqua-Box Owner’s Manual
www.deroyal.com 800.251.9864
INSTALLATION DIAGRAM: PLUMBING CONNECTIONS
Applies to 1200 & 1100 Models
™
(1/2” for Model 1100)

www.deroyal.com 800.251.9864
13
Fluid Waste Evacuation & Disposal
1. Remove the cover from the control box
by unscrewing the four plastic cover screws.
2. Feed the three wires from the electric
solenoid valve into the control box. A rigid
or flexible conduit is recommended to house
the wires from the solenoid valve to the
control unit. A flexible conduit is included
with the Aqua-Box.
3. The electrical supply wires ship pre-
connected. Should they need to be
reconnected, the hot (white) wire should be
connected to post #1 and the neutral (black)
to post #2.
4. Connect one of the red wires from the
solenoid valve to post #8 and the other red
wire to post #2. The green (ground) wire
should be connected to post #3.
5. The control box cover should be replaced
by screwing clockwise the four plastic cover
screws.
6. Plug the control box into a standard
110/120 Volt electrical outlet. The electrical
outlet should be GFCI protected as per local
codes. The electrical connection may be hard
wired by cutting off the plug, if preferred.
ELECTRICAL CONNECTIONS: NON-RINSING UNITS
For Models 1500-00 and 1300-00 only, the following steps provide the instructions for the electrical connections.
(White)
(Black)
(Green)
(Red)
(Red)

14
Aqua-Box Owner’s Manual
www.deroyal.com 800.251.9864
ELECTRICAL CONNECTIONS: RINSING UNITS
For Model 1300-R only, the following steps provide the instructions for the electrical connections. The 1300-R ships completely
pre-wired. Other than plugging the unit into a standard 110/120 AC Volt outlet, no electrical connections are required for
installation. The following instructions are provided should the controller box need to be disconnected for some reason (i.e.,
replacement).
1. Remove the cover from the control box
by unscrewing the four plastic cover screws.
2. Feed the wiring harness into the
connection on the large box. Tighten fitting
and attach the marked wires to the terminal
strip marked the same.
3. Connect the three wires marked Q1,
Q2, and Q3 to the terminal. Connect the
white common and the green ground to the
strip marked the same.
4. Plug the control box into a standard
110/120 Volt electrical outlet. The electrical
connection may be hard wired if preferred.
The program will start and the time needs
to be set. Press ESC, scroll down to the
clock, press OK and adjust the clock with
the arrow buttons Press OK again when the
time is set, close the program out and go to
start. Your clock should now be set.
5. The control box cover should be replaced
by screwing clockwise the four plastic cover
screws.
GROUND
COMM
Q3
Q2
Q1

www.deroyal.com 800.251.9864
15
Fluid Waste Evacuation & Disposal
ADJUSTING THE AUTOMATIC TIMER SWITCH
(MODELS 1500-00 & 1300-00)
For Models 1500 and 1300, the Aqua-Box power button is
pre-set to stay on for 2 minutes. This pre-set time can be
easily changed by the facility as needed. The “kill” switch will
turn off the unit prior to the end of the timed cycle if desired.
To adjust the automatic timer switch, conduct the following
steps.
1. Unscrew the face of the control unit by unscrewing
(counter-clockwise) the four plastic cover screws.
2. Adjust the timer according to your specific needs. The
timer scale is in seconds.
3. Replace the face of the control unit by screwing in
(clockwise) the four plastic cover screws.
SETTING & ADJUSTING THE ELECTRONIC CONTROLLER
(MODEL 1300-R)
For Model 1300-R, the Aqua-Box power button is pre-set to
stay on for 5 minutes. This pre-set time can be easily changed
by the facility as needed. The “kill” switch will turn off the
unit prior to the end of the timed cycle if desired. To adjust
the automatic timer switch, conduct the following steps.
1. Once the electrical cord has been plugged into the 110
volt outlet, the Program should start. The time will need to
be set.
2. Adjust the timer according to your specific needs. The
timer scale is in seconds. Press ESC, scroll down to the clock,
press OK and adjust the timer with the arrow buttons. Press
OK when you have selected the correct times, close the
program and go to Start. Your timers should now be set.
3. Replace the face of the control unit by screwing in
(clockwise) the four plastic cover screws.

16
Aqua-Box Owner’s Manual
www.deroyal.com 800.251.9864
RIGID CANISTERS
1. Transport full canisters by cart or roll-stand to the Aqua-
Box using PPE’s in accordance with hospital policy.
2. Ensure that the appropriate Evacuation Tube is attached
to the end of the suction hose (C).
3. If fluid treatment option is used, verify that there is
sodium hypochlorite (bleach) and that the yellow tube (F)
is submerged in the bleach. Check to see if the valve (E) for
bleach line is open (vertically oriented).
4. Open pour spout of the suction canister(s).
5. Insert the Evacuation Tube and seal the port with the
purple cap.
6. Turn the unit “On”.
a. For Models 1500 and 1300, press the “Start” button
(A). If the Aqua-Box shuts off while evacuating,
simply press “Start” button (A) again.
b. For Models 1200 and 1100, turn the valve on the
right side of the unit to the “On” position.
7. Open Thumb valve (D) to begin evacuation.
INSTRUCTIONS FOR USE
NON-RINSING UNITS
A - “Start” Switch
B - “Kill” Switch
C - Suction Hose (Grey)
D - Thumb Valve
E - Treatment Solution Valve
F - Treatment Solution Tube (Yellow)
G - Suction Hose Hanger
A B
D
G
C
E
F
Warning: As whenever handling any infections liquid waste, PPE’s should be worn at all times in accordance with facility policies.

www.deroyal.com 800.251.9864
Fluid Waste Evacuation & Disposal
17
8. When canister is empty, leave thumb valve open for a
few seconds, then close thumb valve (D), replace cap on
canister, then discard empty canister.
9. If evacuating multiple canisters at one time, leave the
thumb valve (D) open and move the evacuation tube to the
next canister. Repeat until the last canister has been emptied.
10. When the last canister has been evacuated, and with the
Aqua-Box still running, place the Evacuation Tube in either:
a. Fresh water for 5 seconds to flush the Aqua-Box.
b. Enzymatic solution for 2 seconds to flush,
deodorize, and prevent organic and mineral deposits
from accumulating within the Aqua-Box.
11. Close the thumb valve (D) on the suction hose.
12. Turn the unit “Off”.
a. For Models 1500 and 1300, press the “Kill” switch
(B) on the side of the control box.
b. For Models 1200 and 1100, turn the valve on the
right side of the unit to the “Off” position.
13. Discard the old evacuation tube and replace with a new
tube.
14. Hang up suction hose (C) on suction hose hanger (G).
LINER SYSTEMS
When purchasing an Aqua-Box for a facility that utilizes
liners without pour spouts, such as those manufactured by
Hospira, the Aqua-Box must be ordered with a liner adapter.
Because the adapter attaches directly to the liner portal, it
eliminates the need for evacuation tubes.
NOTE: A liner adapter can only be used with flexible liners.
1. Remove liner from canister shell and uncap tubing. Use a
clamp on the hose.
2. Press fit end of suction hose to any fluid port on liner.
(Be careful not to attach suction hose to vacuum port on
liner because fluid will be prevented from being evacuated
due to shut off valve).
3. Turn the unit “On”.
a. For Models 1500 and 1300, press the “Start” button
(A). If the Aqua-Box shuts off while evacuating,
simply press “Start” button (A) again.
b. For Models 1200 and 1000, turn the valve on the
right side of the unit to the “On” position.
4. Liner will collapse as fluid is evacuated.
5. Detach the liner from the suction hose and replace tube
to suction port and discard.
6. With the Aqua-Box running, aspirate some disinfectant
through adapter.
7. Turn the unit “Off”.
a. For Models 1500 and 1300, press the “Kill” switch
(B) on the side of the control box.
b. For Models 1200 and 1100, turn the valve on the
right side of the unit to the “Off” position.

18
Aqua-Box Owner’s Manual
www.deroyal.com 800.251.9864
RIGID CANISTERS
1. Transport full canisters by cart or roll-stand to Aqua-Box
using PPE’s in accordance to hospital policy.
2. Ensure that the appropriate Evacuation Tube is attached
to the end of the suction hose (C).
3. If fluid treatment option is used, verify that there is
sodium hypochlorite (bleach) and that the yellow tube (F)
is submerged in the bleach. Check to see if the valve (E) for
bleach line is open (vertically oriented).
4. Open pour spout of the suction canister(s).
5. Insert the Evacuation Tube and seal the port with the
purple cap.
6. Turn the unit “On”.
a. For Models 1500 and 1300, press the “Start” button
(A). If the Aqua-Box shuts off while evacuating,
simply press “Start” button (A) again.
b. For Models 1200 and 1000, turn the valve on the
right side of the unit to the “On” position.
7. Open Thumb valve (D) to begin evacuation.
8. When canister is empty, close thumb valve (D), replace
cap on canister, then discard empty canister.
9. After the canister is empty, leave the wand in the
canister and press the Rinse button. Fresh water will flow
back through the wand (about 600ccs). The suction will
automatically start to evacuate the remaining fluid. Close the
Thumb valve and press the stop button.
RINSING UNITS
A - “Start” Switch
B - “Kill” Switch
C - Suction Hose (Grey)
D - Thumb Valve
E - Treatment Solution Valve
F - Treatment Solution Tube (Yellow)
G - Suction Hose Hanger
H - “Start” Rinse Switch
AH
B
D
G
C
F
E

www.deroyal.com 800.251.9864
19
Fluid Waste Evacuation & Disposal
10. When the last canister has been evacuated, and with the
Aqua-Box still running, place the Evacuation Tube in either:
a. Fresh water for 5 seconds to flush the Aqua-Box.
b. Enzymatic solution for 2 seconds to flush,
deodorize, and prevent organic and mineral deposits
from accumulating within the Aqua-Box.
11. Close the thumb valve (D) on the suction hose.
12. Turn the unit “Off”.
a. For Models 1500 and 1300, press the “Kill” switch
(B) on the side of the control box.
b. For Models 1200 and 1100, turn the valve on the
right side of the unit to the “Off” position.
13. Discard the old evacuation tube and replace with a new
tube.
14. Hang up suction hose (C) on suction hose hanger (G).
LINER SYSTEMS
When purchasing an Aqua-Box for a facility that utilizes
liners without pour spouts, such as those manufactured by
Hospira, the Aqua-Box must be ordered with a liner adapter.
Because the adapter attaches directly to the liner portal, it
eliminates the need for evacuation tubes.
NOTE: A liner adapter can only be used with flexible liners.
1. Remove liner from canister shell and uncap tubing. Use a
clamp on the hose.
2. Press fit end of suction hose to any fluid port on liner.
(Be careful not to attach suction hose to vacuum port on
liner because fluid will be prevented from being evacuated
due to shut off valve).
3. Turn the unit “On”.
a. For Models 1500 and 1300, press the “Start” button
(A). If the Aqua-Box shuts off while evacuating,
simply press “Start” button (A) again.
b. For Models 1200 and 1000, turn the valve on the
right side of the unit to the “On” position.
4. Liner will collapse as fluid is evacuated.
5. To Rinse: after Canister is empty, leave the adapter inside
the canister and press the rinse button. Fresh water will
flow back through the wand (about 600ccs). Suction will
automatically initiate to evacuate remaining fluid. Close the
thumb valve and press the stop button when finished.
6. Detach the liner from the suction hose and replace tube
to suction port and discard.
7. With the Aqua-Box running, aspirate some disinfectant
through adapter.
8. Turn the unit “Off”.
a. For Models 1500 and 1300, press the “Kill” switch
(B) on the side of the control box.
b. For Models 1200 and 1100, turn the valve on the
right side of the unit to the “Off” position.

20
Aqua-Box Owner’s Manual
www.deroyal.com 800.251.9864
EVACUATION TUBES
The Evacuation Tube is the disposable portion of the Aqua-
Box’s suction line that enters the suction canister. It is to be
used as follows:
1. After canister evacuation, keep Evacuation Tube attached
to canister.
2. Detach the Evacuation Tube from the Aqua-Box’s gray
suction hose.
3. Reseal canister and discard tube.
4. Attach a NEW Evacuation Tube to the Aqua-Box hose.
5. Submerge the new evacuation tube in clean water or
enzyme solution for 1 second while the Aqua-Box is running.
This flushes the gray suction hose and Aqua-Box interior of
waste fluid.
6. Hang-up hose and evacuation tube on hanger for next
use.
MAINTENANCE
Cleaning
Routine maintenance is limited to a periodic enzymatic
cleaning to prevent mineral and organic build up allowing
the unit to run at peak efficiency. The Aqua-Box must have
an enzymatic cleaner flushed through it on a weekly basis
to prevent mineral and organic build-up. This will keep the
unit running at peak efficiency. One gallon of concentrated
cleaner will last well over a year in most facilities. Any
enzymatic cleaner already stocked by the facility will work. A
recommended weekly enzymatic cleaner is available from:
Enzyme Industries
Heath, OH
Phone: 888-236-9963
Product #4198-1
To clean, mix enzymatic cleaner with water according to
manufacture’s instructions in a suction canister, or other
container. Evacuate the enzymatic solution as you would
normally.
Reduced Pressure Zone (RPZ) Valve
The RPZ valve requires annual certification by a licensed
plumber. It may require periodic maintenance in accordance
with the manufacture’s instructions. Maintenance kits are
available at most plumbing supply stores.
This manual suits for next models
3
Table of contents
Popular Control Unit manuals by other brands

Siemens
Siemens SIPROTEC 4 7XT7100-0 A00/EE Series Product information

Emerson
Emerson YARWAY 60Y Series Installation, operation and maintenance manual

Lucent Technologies
Lucent Technologies PacketStar PSAX 1250 manual

GAI-Tronics
GAI-Tronics MDC-1200 installation instructions

BIRD
BIRD Termaline 8792 Series Operation manual

CommScope
CommScope ATSBT-4G Series instruction sheet