VT 5004S 2X
Proportional Amplifier(for Manual T e Operation)
2
REV:0/07
::: Hidrosam Hidropar Hidrolik Pnömatik Elektronik San. ve Tic. Ltd. Şti. :::
Nilüfer Ticaret Merkezi Demirci Mah. 62. Sok. No:2 Nilüfer / BURSA / TÜRK YE
Tel : 90-224-441 88 77 Pbx Fax : 90-224-441 03 33 www.hidrosam.com info@hidrosam.com
amplifier. It means that programmable ontroller (PLC)
should not use the same power with the amplifier.
The usage of the amplifier
1. This amplifier an supply +9V(16A, C) and –9V(14A or 26C) flat voltage.
Besides self voltage supply, +9V an be supply voltage signal to external
potentiometer.
2. When the differential motion signal from program ontroller (PLC) or the
omputer, the bit shift of the solenoid an be ontrolled by the 0-+10V
voltage input from 22A and 24 C.
3. There is two pair of testing hole for nominal value (0-+6V) and real value
(0- -6V), through voltage value of the testing hole for the nominal value,
the monitoring for the input voltage an be realized. When the input
voltage is 0-+9V, the nominal value from the testing hole is 0-+6V. When
the real value is zero, the spool should be zero position. When the real
value is -6V, the spool should be at the Max.stro k. . If the spool is in the
middle, the real valve should be between the 0- -6V. The nominal value
and the absolute value o the real value should be equivalen e. It is also
the way to test if the amplifier is work or not.
4. There are potentiometers that an adjust the ramp time, it an adjust the
rise time and fall time separately. When the input voltage to the
Max.value (+9V), the rise time is the Max. value. If no spe ial
requirement, the Max. ramp time is 5 se ond.
If the power unit do not need the ramp time:
(1). Counter lo kwise rotate potentiometer for the ramp time to the
minimum
(2). Swit h on the relay, Short ir uit the ramp ir uit (short ir uit 8A
and 28A)
(3). Short ir uit 30Cand 32C
5. If the amplifier and bit shift shut down or improper onne tion. The
feedba k shut down led light, the able failure identifi ation will key off
the urrent in the solenoid.
Ⅲ. Caution
1. If there is spool vibration, it is aused be ause there is air in the valve
usually. You an pulse on the hydrauli ir uit, open the air bleed s rew,
let the spool alternating motion till the air was exhausted.
2. The voltage of <MO> port (18A,C) is ompared with the input voltage
0V(10A, C) in rease +9V, never short- ir le them.
Ⅳ. This amplifier is European standard 32 pin (5.08X5.08mm). VT-3002B
and VT1516B holder an mat h with this amplifier.