DFI iMage-M User manual

Multi-Person Fever Detection
With Mobotix M16 Thermal camera
User’s Manual

- 2 -
Version information:
Version
Content
Date
1.0
First release
2020/05
EZMatch Face Specification

- 3 -
1. Installation........................................................................................... 4
2. Camera Setting
2-1. Initial system setting................................................................... 5
2-2. IP setting............................................................ 6
2-3. Temperature Compensation........................................................ 7
2-4. Connect with EZ Pro........................................................ 8
2-5. Alarm Sound Setting........................................................ 9
2-6. Temperature Alarm Event and Measurement Area...................... 10
2-7. Alarm event setting............................................................ 14
2-8. Alarm Output............................................................ 15
2-9. Save the Configuration............................................................ 16
3. EZ Pro Setting
3-1. EZ Pro event setting..........................................................17

- 4 -
1. Installation
(1) The recommended erection height is 2.5-3 meters
(2) The recommended distance to the subjects is 3 meters
(3) The thermal lens must be adjusted according to the environment.
(4) Avoid strong light in the installation environment.
(5) Outdoor ground temperature would affected by weather, please avoid capturing the
outdoor ground.
(6) Thermal camera is unable to capture subjects blocked by glass.
(7) Subjects shouldn’t be set under the air-conditioner, and avoid reflective objects,
reflective objects, and hot objects around, such as: stainless steel, mirror, glass,
electrical appliances, hot food, etc.

- 5 -
2. Camera Setting
2-1. Initial system setting
(1)Default ip of the camera is posted on the outer box
(2)To search the camera, please check the ip setting of your PC.
The IP address must be set to 10 network segments, and the subnet
mask should be set to 255.0.0.0
(3)To get to the web interface, please enter the default ip of camera
(4)Default login information:
user:admin password:admin13579

- 6 -
2-2. IP setting
To modify the IP of the camera, please go to the web interface【Admin Menu】>【Network
Setup】>【Ethernet Interface】
(1)Turn off BOOTP/DHCP
(2)Set up newIP address and network mask

- 7 -
2-3. Temperature Compensation
To do the temperature calibration, please go to the web interface【Setup Menu】>【Image
Control】>【Thermal Sensor Settings】>【Temperature Compensation】
Device has been set the temperature compensation before leaving the factory. To ensure the
accuracy, please set the temperature compensation before you start to use.
To calibrate the temperature, you need to set a subject with constant temperature. If the
temperature measured by is different from the subject, please adjust the atmospheric
transmission and ambient temperature.
(* The recommended value of atmospheric transmission is below 98. When the atmospheric
transmission be set as 100, it means ther is no air obstruction between device and subject, it
makes the ambient temperature parameter invalid.)
2-4. Connect with EZ Pro
To connect with EZ Pro, please go to the web interface【Admin Menu】>【Transfer Profiles】
>【IP Notify Profiles】>【Add New Profile】
Please set the new profile as below:
(1) IP Notify Type
Choose
(2) Destination Address
Enter EZ Pro serverIP(and port)
(3) Data Protocol
Please choose the item as below and the fill admin:admin13579 in the third field.
(4) Data Type
Choose Plain text

- 8 -
Fill in the string below
&caption=$(SEN.TTR.CELSIUS)&description=$(ID.ET0), $(ID.ETHERNET)
(5) Send Port
Set

- 9 -
2-5. Alarm Sound Setting
Turn on the Audio Output
To set the audio input/output, please go to the web interface【Admin Menu】
>【Audio and VoIP Telephony】>【Speaker and Microphone】
Alarm Sound Setting
Please go to the web interface【Admin Menu】>【Audio and VoIP Telephony】
>【Sound Profiles】

- 10 -
2-6. Temperature Alarm Event and Measurement Area
Please go to the web interface【Setup Menu】>【Event Control】>【Event Overview】>
【Environment Events】
Set the minimum alarm temperature (ex:alarm when temperature reach 37.5
degree)
(1) Add a new Environment Events, we named as ‘Tar’.
(2) Event Dead Time
Delay alarm for few seconds when event occur.
(3) Event Sensor Type
Choose Thermal Radiometry
(4) Edit Measurement Area
To set the measurement area, please click the blank setting box first.
Open the live view page (don’t close the setting page).
Use shift + left-click on the thermal image, you will see the first set point.
Then release shift, left-click second point in the image.
Two point will be connected into a quad automatically.
After drawing the quad, press ,system will update the coordinate.

- 11 -
(5) Measurement Mode and Trigger Mode
(6) Set the Alarm Condition
Set the minimum alarm temperature, and choose Higher than.
Camera will alarm when the temperature higher than 37.5 degree.
(7) Thermal Radiation Setting
The are some thermal radiation parameters down below, please choose the
suggested options.
(8) Press to save the configuration.

- 12 -
Set the maximum alarm temperature (ex:alarm when temperature lower than
40 degree)
(1) Add a new Environment Events, we named as ‘Limit’
(2) Event Dead Time
Delay alarm for few seconds when event occur.
(3) Event Sensor Type
Choose Thermal Radiometry.
(4) Edit Measurement Area
To set the measurement area, please click the blank setting box first.
Open the live view page (don’t close the setting page).
Use shift + left-click on the thermal image, you will see the first set point.
Then release shift, left-click second point in the image.
Two point will be connected into a quad automatically.
After drawing the quad, press ,system will update
the coordinate.

- 13 -
(5) Measurement Mode and Trigger Mode
(6) Set the Alarm Condition
Set the maximum alarm temperature, and choose lower than.
Camera will alarm when the temperature lower than 40
(7) Thermal Radiation Setting
The are some thermal radiation parameters down below, please choose the
suggested options.
(8) Press to save the configuration.

- 14 -
2-7. Alarm event setting
Please go to the web interface【Setup Menu】>【Event Control】>【Event Overview】>
【Meta Events】
Press to enter the edit page.
(1) Add a new event
(2) Event Sensor Type
(3) Logic event need to set two logic condition, please set the event ’Tar’ and ‘Limit’
we just set, and set the order of occurrence.
(4) Minimum Delay
Set the time delay between two events.
(5) Maximum Delay
Set the time limit between two events.

- 15 -
2-8. Alarm Output
Please go to the web interface【Setup Menu】>【Event Control】>【Event Overview】>
【Action Group Overview】
(1) Edit the alarm setting
(2) Action Group
Here user can name a alarm, turn on the alarm, and set time table.
(*Choose No time table to enable the alarm whole day.)
(3) Event Selection
Please choose the alarm event we have set.
(4) Action Details
(*For real-time, multi-object detection, it is recommended to select the action
chain Simultaneously)

- 16 -
(5) Actions
Do the actions below when event occur.
(*Commonly actions like: Visual Alarm: Red Frame, Play Sound...)
2-9. Save the Configuration
Please go to the web interface【Admin Menu】->【Configuration】
After setting all the parameters and event, must save the configuration into the camera flash .
Store:store current configuration to camera flash permanently. Need to restart the camera
after save it.
Reset:reset all configuration.
Restore:restore last stored configuration.
Load:import cfg file from local server. It is necessary to‘store’ to the camera flash after
import it.
Save:export cfg file with current configuration.

- 17 -
3. EZ Pro Setting
3-1. EZ Pro event setting
【Set camera recording】
To use the broadcast function of EZ Pro (including: sound alarm, record events,
etc.), it is necessary to turn on the camera recording.
(1) Right-click on the camera name, choose ‘Camera Setting’.
(2) Turn on the ‘recordming’ in the Recording page.

- 18 -
(3) There will be a red point on the left side of camera icon when the camera is
recording.
【Add an alarm event】
(1) New an event rule
【Main Menu】> 【System Sdministration】> 【Event Rules】> 【Add
new event rule】
(2) Set the event rule
Press on the right side.
Choose Generic Event, and enter the source contains hot.
(3) Set action
When event occurs, do the action on EZ Pro. (ex:play sound, write
bookmark, etc. One event rule can only do one action, if you need to do
more than one action, please add new event rule.)

- 19 -
(4) Interval of action
An interval between events. If immediate report is required, please cancel.
(5) Press save.