Page 1 of 2
Product Profile
DSP-22 Vehicle Detector
All this and a 5-Year Warranty too!
Features
Works on any in-ground
inductive loop from 20 to
2000 microhenries.
Designed to be cross talk
free between other loops
Automatically compensates
for loop and lead-In sizes
Separate Power/Fail and
Detect LED's for both
channels
Small profile, perfect for
many installations
Fail safe operation
Operates on 12 VDC
This series of Diablo Controls
detectors are covered by
United States patent.
Patent number US 7,132,959
“Non-Interfering Vehicle
Detection.”
Available in single and dual
channel models. Matches
DKS® 9410-10 single
channel or DKS® 9409-10
dual-channel detector
Overview
The DSP-22S detector will add a new dimension of simplicity to your plug-in
detector requirements. This series of Diablo's detectors are covered by
United States patent number US 7,132,959 “Non-Interfering Vehicle
Detection.” These detectors are virtually cross-talk free in most applications.
This micro-sized detector will automatically adjust its sensitivity level when
used on different sized loops. The detector loop inductance should be
between 20 and 2000 microhenries.
LED Indicators
The green Power LED will be on steady to indicate the detector is operating
and powered. The red Detect LED will turn on when a vehicle is over the
loop detection area.
Detect Memory
Power interruptions of short duration are ignored. If power fails for
approximately 1 ½ seconds or less the detector “remembers” a vehicle.
Sensitivity and Reset Push Button
The Reset/Sens. button is used for two functions. A short press and
release of the button will reset the detector and the LED's will both flash
from 1 to 4 times, indicating the detector's sensitivity level. The detector is
shipped from the factory with the sensitivity set at level 3.
If a different sensitivity level is required:
Push and continue to hold the button until the LED's start flashing - release
the button immediately after the desired number of flashes. For example, if
the sensitivity is to be changed to level 2, push and hold the button until the
LED's flash twice then immediately release the button. The sensitivity level
can always be verified by a quick tap on the push button. This will reset the
detector and flash the two LED's indicating the present level.
Level 1 - Very Low
Level 2 - Low
Level 3 - Normal (Factory setting)
Level 4 - High
Loop or Wire Failures
In the case of a loop circuit failure, the green LED flashes slowly (twice per
second) for an open loop circuit failure. The green LED will flash fast (10
times per second) to indicate a shorted loop circuit.
Fail Safe vs Fail Secure
A fail safe detector will output “detect” when the loop circuit is failed. This is
always useful on a safety loop. On the free exit loop this will keep the gate
open until the situation is fixed. This is useful in applications where it is
important to allow traffic flow to continue. A fail secure detector will never
output “detect” when the loop circuit is failed. This will keep the gate
closed. This is useful in high-security areas or installations where
containment is needed. The DSP-11 is a fail safe detector. Note: Never
use a fail secure detector on a safety loop.
Page 2 of 2
Visit our Website at www.diablocontrols.com for the most current information on all of our products.
Specifications are subject to change.
DSP-22_CUT_A 2/5/2014
Product Profile
DSP-22 Vehicle Detector
Outputs
Solid-state (open transistor collector) for Channel 1 detect and a SPDT 1 amp relay output for Channel 2.
Power
12 to 30 volts DC
Operating Temperature
-35°F to 165°F (-37°C to 74°C)
Size
Height: 4.4" Width: 3.0" Depth: 0.8”
J1 Connector
3-position male for mating with the gate operator PCB.
Pin 1 – Power in 12 to 30 volts DC
Pin 2 ‒Common
Pin 3 ‒Channel 1 solid state output (Connects to common for detect)
J2 Connector
7-position terminal block for external connections
1 - Loop input for detector #1
2 - Loop input for detector #1
3 - Loop input for detector #2
4 - Loop input for detector #2
5 - Channel 2 relay N.O. (Closes for detect)
6 - Channel 2 relay common
7 - Channel 2 relay NC. (Opens for detect)
Ordering Information
Standard part numbers are as follows:
DSP-22-x
x = 1 = Single channel model
x = 2 = Dual channel model
Veteran Owned & Operated
Diablo Controls, Inc.
565 Dakota St, Unit F
Crystal Lake, IL 60012
Toll Free 866-395-6677
www.diablocontrols.com
[email protected]

Other Diablo Controls Security Sensor manuals

Diablo Controls DSP-40S User manual

Diablo Controls

Diablo Controls DSP-40S User manual

Diablo Controls DSP-100 Series User manual

Diablo Controls

Diablo Controls DSP-100 Series User manual

Diablo Controls DSP-15 User manual

Diablo Controls

Diablo Controls DSP-15 User manual

Diablo Controls DSP-50 User manual

Diablo Controls

Diablo Controls DSP-50 User manual

Popular Security Sensor manuals by other brands

Powerfix Profi 298736 Operation and safety notes

Powerfix Profi

Powerfix Profi 298736 Operation and safety notes

MSA FireHawk Rescue Belt II Instructions for use

MSA

MSA FireHawk Rescue Belt II Instructions for use

GORBEL Tether Track Installation, operation & maintenance manual

GORBEL

GORBEL Tether Track Installation, operation & maintenance manual

Visonic CLIP MCW installation instructions

Visonic

Visonic CLIP MCW installation instructions

Master cool 55600-A operating instructions

Master cool

Master cool 55600-A operating instructions

Nobile Smartmatic 9108011012 Mounting Operation Instruction

Nobile

Nobile Smartmatic 9108011012 Mounting Operation Instruction

DualLite SEWL Series Installation, Operation and Maintainance Instructions

DualLite

DualLite SEWL Series Installation, Operation and Maintainance Instructions

Pepperl+Fuchs NBB10-30GS50-Z4L-V1-3G-3D instruction manual

Pepperl+Fuchs

Pepperl+Fuchs NBB10-30GS50-Z4L-V1-3G-3D instruction manual

C.P. Electronics MWS3A-DD Product guide

C.P. Electronics

C.P. Electronics MWS3A-DD Product guide

Omron E9NC-TH Series instruction sheet

Omron

Omron E9NC-TH Series instruction sheet

teko Astra-621 RF user guide

teko

teko Astra-621 RF user guide

Mastech MS5905RTB manual

Mastech

Mastech MS5905RTB manual

Reno A&E U-1400 Operation manual

Reno A&E

Reno A&E U-1400 Operation manual

Macurco HD-11 User instructions

Macurco

Macurco HD-11 User instructions

Teletek electronics SensoIRIS GAS manual

Teletek electronics

Teletek electronics SensoIRIS GAS manual

SIUI CTS-9006 Operation manual

SIUI

SIUI CTS-9006 Operation manual

BEA WIZARD II SMR user guide

BEA

BEA WIZARD II SMR user guide

Hotron SSR-3 user manual

Hotron

Hotron SSR-3 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.