1 FUNCTION
The detector is designed to detect intrusion into
protected space and/or glass breaking of the
glazed structures, generate an alarm notifica-
tion and transmit the notification via radio to the
radio receiver.
The detector is insensitive to pets up to 20 kg
weight.
2 DETECTION ZONE
3 SPECIFICATIONS
2 range of acoustic operation frequencies:
- first (high), kHz ..................................6.0 ± 0.1
- second (low), Hz................................150 ± 10
Wireless coverage range (line-of-sight), m...300
Supply voltage, V................................2.2 to 3.0
Overall dimensions, mm.....................92×64×45
Operation conditions
Temperature range, °С.................... - 20 to + 55
Relative air humidity, % .......up to 98 at + 25°С
without moisture condensa-
tion
4 DELIVERY SET
Set includes: mounting parts (dowel - 2 pcs.,
screw - 2 pcs.), battery CR123A 3V (installed) –
1 pc., bracket –1 pc., user guide –1 copy.
5 INDICATION
Notification indication turns off 60 min. later
(except for the “Power failure” notification) after
the installation of the battery. Re-enabling the
indication - when installing the battery or upon
receiving any command from the laser tool
Astra-942.
Notification
LED
CP
Boot time
Lights up for a peri-
od of 1 to 20 sec,
then flashes 1 time
in 2 sec (no more
than 60 sec)
-
Norm
Off
+
Acoustic
alarm
Lights up for 2 sec
+
PIR-alarm
Lights up for 1 sec
+
Low freq.
interference
1x flashes with a
period of 0.6 ec
when exposed to
interference
-
Hi freq. inter-
ference
2x flashes
with a period of 0.6
sec when exposed
to interference
-
Tampering
Off
+
Tampering
recovered
Off
+
Power failure
3x flashes with a
period of 25 sec
+
‘+’–notification issued,
‘-‘–notification not issued
6 REGISTRATION
ATTENTION!
When registering a detector in the receiver, the
frequency of the detector and the receiver must
match.
1) Remove the detector
cover by pushing the
cover latch out of the
base groove.
2) Pull out the battery
insulator or install the battery, observing the
polarity.
3) By closing the Lit contact with a screwdriver,
set the required operating frequency of the
detector in accordance with the receiver’s fre-
quency
- 1x flash –frequency 1 set
- 3x flash –frequency 3 set
4) Start the registration mode on the receiver
according to the method described in the Man-
uals.
The mode starts for 45-60 sec.
5) Power on the detector by removing and rein-
stalling the battery. Wait at least 20 sec before
power on again.
In case of unsuccessful registration, remove the
battery and repeat the procedure.
6) Check the registration, according to the
method described in the Manuals.
7 INSTALLATION PLACE
1) Recommended installation height is
2.3-2.5 m and at a distance not more than 6m
from the most distant point of protected glass.
2) The detector cannot be used in premises
with high level of acoustic interference.
To eliminate false alarms
1) It is recommended to close all doors, air-
vents, switch off possible sourses of intense air
flows (fans, air-conditioners) and acoustic inter-
ferences (loudspeakers, etc.) in the room during
protection period.
2) The detector's location should provide di-
rect visibility of all secured glass parts; masking
the detector with decorative curtains is not al-
lowed, as sensitivity may be lost.
8 INSTALLATION ORDER
1) Fix the bracket
2) Power on the de-
tector if it was previ-
ously turned off (see
p. 6, steps 1) and 2)).
3) Close detector’s
cover.
4) Mount the detector on the
bracket, aligning the grooves
for the bracket on the detec-
tor base with the bracket
latches and pushing the
base until it stops (until it
clicks).
Orient the base of the detector strictly
according to the figure!
It is possible to install using the Atra-5/621 bracket
(supplied separately).
5) Test Acoustic-channel and PIR-channel (see
p. 9)
9 TEST
If more than 60 minutes have passed since the
detector was powered on, reinstall the battery
and close the detector’s cover, or light up the
detector indicator with any button of the laser
tool.
AC-channel:
1) Using a glass break simulator, check the
detector operation for glass break simulation,
high-frequency and low-frequency noise (see
table).
Note –It is recommended to use “Honeywell“: FG-
701 Glassbreak Simulator, “DSCTM”: AFT-100
Glass-break Simulator.
2) Check in the event log of the receiver
presence of the “Alarm” entry on the 2nd
detection channel.
PIR-channel:
1) Perform TEST-pass.
2) At the moment of detection,
the indicator of the detector
lights up for 1 sec.
3) Check in the event log of the
receiver presence of the
“Alarm” entry on the 1st
detection channel.
10 WARRANTY
The operation warranty period is 5 years from
the date of operation start-up but no longer than
years 6 months from the date of manufacturing
subject to the requirements of the User guide.

Other teko Security Sensor manuals

teko Astra-7 ver.A User manual

teko

teko Astra-7 ver.A User manual

teko Astra-8 User manual

teko

teko Astra-8 User manual

teko Astra-5121 User manual

teko

teko Astra-5121 User manual

teko Astra-GB User manual

teko

teko Astra-GB User manual

teko Astra-3221 User manual

teko

teko Astra-3221 User manual

teko Astra-621 User manual

teko

teko Astra-621 User manual

teko Astra-515 ver.A User manual

teko

teko Astra-515 ver.A User manual

teko Astra-5131 User manual

teko

teko Astra-5131 User manual

teko Astra-516 User manual

teko

teko Astra-516 User manual

teko Astra-9 Installation instructions

teko

teko Astra-9 Installation instructions

teko Astra-642 User manual

teko

teko Astra-642 User manual

teko Astra-43A User manual

teko

teko Astra-43A User manual

teko Astra-621 User manual

teko

teko Astra-621 User manual

teko Astra-3321 User manual

teko

teko Astra-3321 User manual

teko Astra-5131 User manual

teko

teko Astra-5131 User manual

teko Astra-531 PIR Installation instructions

teko

teko Astra-531 PIR Installation instructions

teko Astra-621 User manual

teko

teko Astra-621 User manual

teko Astra-361 Installation instructions

teko

teko Astra-361 Installation instructions

teko Astra-551 User manual

teko

teko Astra-551 User manual

teko Astra-6131 User manual

teko

teko Astra-6131 User manual

teko Astra-431 ver. RF User manual

teko

teko Astra-431 ver. RF User manual

teko Astra-551 User manual

teko

teko Astra-551 User manual

teko Astra-5 Ver.A User manual

teko

teko Astra-5 Ver.A User manual

teko Astra-Z-3645 User manual

teko

teko Astra-Z-3645 User manual

Popular Security Sensor manuals by other brands

TRU Components KMP001-1 operating instructions

TRU Components

TRU Components KMP001-1 operating instructions

Amprobe ULD-300 user manual

Amprobe

Amprobe ULD-300 user manual

BEA LZR-FLATSCAN SW quick guide

BEA

BEA LZR-FLATSCAN SW quick guide

MAXIMUM Security VIP Pro Installation & operating guide

MAXIMUM Security

MAXIMUM Security VIP Pro Installation & operating guide

Reed Instruments C-380 instruction manual

Reed Instruments

Reed Instruments C-380 instruction manual

LEGRAND Bticino MyHOME 3518MW instructions

LEGRAND

LEGRAND Bticino MyHOME 3518MW instructions

Altronix ABH-B Series installation guide

Altronix

Altronix ABH-B Series installation guide

B.E.G. LUXOMAT PD4N-DALILINK Mounting instructions

B.E.G. LUXOMAT

B.E.G. LUXOMAT PD4N-DALILINK Mounting instructions

Bohle BO 51 646 12 quick start guide

Bohle

Bohle BO 51 646 12 quick start guide

STEINEL MotionSwitch LED Z-Wave manual

STEINEL

STEINEL MotionSwitch LED Z-Wave manual

ion science TIGER LT user manual

ion science

ion science TIGER LT user manual

ETC Echoflex Elaho installation guide

ETC

ETC Echoflex Elaho installation guide

Uni-Trend UT12B operating manual

Uni-Trend

Uni-Trend UT12B operating manual

Videofield IMD 200 Product installation sheet

Videofield

Videofield IMD 200 Product installation sheet

Aprilaire Z10ODT Installation and operator's manual

Aprilaire

Aprilaire Z10ODT Installation and operator's manual

Det-Tronics Automatic Eagle Quantum EQ2200UV manual

Det-Tronics

Det-Tronics Automatic Eagle Quantum EQ2200UV manual

Bosch ISW-EN1262 installation guide

Bosch

Bosch ISW-EN1262 installation guide

Elko INELS RFWD-100 manual

Elko

Elko INELS RFWD-100 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.