●This pump like all mechanical equipment requires maintenance.
●Clean the filter and reservoir thoroughly every 6 months using an
anti-bacterial wash. Take care not to damage the signal pins on the
reservoir cover.
Warranty
This warranty covers all parts with material or manufacturing defects for two
(2) years from date of purchase. The buyer’s only remedy is the replacement
or repair of the defective parts. In no case can labor costs and any
consequential damage be cited as a basis for a complaint. Any returned units
must be complete and must be accompanied by a written list of the defects
identified. We are unable to accept any liability in case of nonconforming
installation or noncompliance with the specifications or maintenance
recommendations.
Maintenance
Faults and Troubleshooting
Problem Cause Action
1. Reservoir is not leveled.
2. Reservoir is dirty.
1. Check reservoir to ensure it is installed flat-
side down and on a level horizontal surface.
2. Clean the reservoir and the surface of the
signal pins.
Pump runs all the
time
Remove air from the tube between the
reservoir and the pump after installation and
during operation.
Pump stops and
starts and makes a
loud noise
The water is siphoning back
through the pump
Pump runs but does
not pump any water
There are air-leaks in the pipe
running to the pump.
Check the reservoir and section tube are
free of sludge and debris.
No power supply. Check the power supply.
Incorrect or damaged cable. Check the power cable.
Incorrect voltage. Check the voltage.
Pump does not
operate
-07-
-08-
NOTE: