DirectOut Technologies ANDIAMO.MC Installation instructions

D.O.TEC®ANDIAMO.MC
Ver sion 1.1
Hardware Guide
DirectOut Technologies®

DirectOut Technologies
®
page 2 of 52 © 2013 DirectOut GmbHD.O.TEC®ANDIAMO.MC Manual - Version 1.1
Copyright Note
Copyright
All rights reserved. Permission to reprint or electronically reproduce any docu-
ment or graphic in whole or in part for any reason is expressly prohibited, un-
less prior written consent is obtained from the DirectOut GmbH.
All trademarks and registered trademarks belong to their respective owners. It can-
not be guaranteed that all product names, products, trademarks, requisitions, regulations,
guidelines, specifications and norms are free from trade mark rights of third parties.
All entries in this document have been thoroughly checked; how-
ever no guarantee for correctness can be given.
DirectOut GmbH cannot be held responsible for any misleading or in-
correct information provided throughout this manual.
DirectOut GmbH reserves the right to change specifications at any time without notice.
DirectOut Technologies®andD.O.TEC®are registered trademarks of the DirectOut GmbH.
© DirectOut GmbH, 2013

DirectOut Technologies
®
page 3 of 52© 2013 DirectOut GmbH D.O.TEC®ANDIAMO.MC Manual - Version 1.1
Table of Contents
Table of contents
ABOUT THIS MANUAL 5
How to Use This Manual 5
Conventions 5
CHAPTER 1: OVERVIEW 6
Introduction 6
Feature Summary 6
Applications 7
CHAPTER 2: LEGAL ISSUES & FACTS 8
Before Installing This Device 8
Defective Parts/Modules 8
First Aid (in case of electric shock) 9
Contents 10
Accessories 10
Updates 12
Intended Operation 12
Conditions of Warranty 12
Conformity & Certificates 13
Contact 13
CHAPTER 3: INSTALLATION 14
Installing the Device 14
CHAPTER 4: OPERATION 18
Introduction 18
Global Control 18
Menu Control 19
Clocking 20
Clocking continued - MADI STATE 21
Sample Rates 22
Bank Selection / Signal Routing 23
Output Format 24
Level Settings 25
Level Meters - analog input 26
Display - input channel settings 27
Level meter - analog output 27
Remote protocol 28
MADI / Word clock / USB 30
General Purpose Output 31
Analog Input / Output 32
Delay Compensation 33
CHAPTER 5: MENU NAVIGATION 34
Menu Map 35
Input sensitivity (Gain setting) 36
CHAPTER 6: TROUBLESHOOTING AND
MAINTENANCE 39
Troubleshooting 39
Maintenance 39

DirectOut Technologies
®
page 4 of 52 © 2013 DirectOut GmbHD.O.TEC®ANDIAMO.MC Manual - Version 1.1
Table of Contents
CHAPTER 7: TECHNICAL DATA 40
APPENDIX A: WIRING DSUB-25 43
DSUB-25 - analog (female) 43
APPENDIX B: WIRING GPO 43
DSUB-9 (female) 43
APPENDIX C: CONFIGURATION EXAMPLES 44
APPENDIX D: SENSITIVITY <> GAIN 46
Explanation 46
Examples 47
INDEX 48

DirectOut Technologies
®
page 5 of 52© 2013 DirectOut GmbH D.O.TEC®ANDIAMO.MC Manual - Version 1.1
About This Manual
About This Manual
How to Use This Manual
This manual guides you through the installation and operation of the
ANDIAMO.MC.
Use the Table of Contents at the beginning of the manual or Index
Directory at the end of the document to locate help on a particular
topic.
You can access more information and latest news by visiting on the
DirectOut website at www.directout.eu.
Conventions
The following symbols are used to draw your attention to:
Tips – indicate useful tips and shortcuts.
Notes – are used for important points of clarification or cross refer-
ences.
Warning
Warnings – alert you when an action should always be observed.

DirectOut Technologies
®
page 6 of 52 © 2013 DirectOut GmbHD.O.TEC®ANDIAMO.MC Manual - Version 1.1
CHAPTER 1: Overview
CHAPTER 1: Overview
Introduction
Welcome to the ANDIAMO.MC, D.O.TEC’s 32 channel microphone
amplifi er with MADI I/O and remote control.
The ANDIAMO.MC provides twoMADI inputs and outputs, 32 chan-
nels mic/line input and 32 channels line output. With two RU height,
low weight, two redundant power supplies and excellent sounding
converters the device offers best and safe audio quality at a minimal
need of rackspace.
Feature Summary
MADI Ports 2 x MADI input and output
2 x SC multi-mode connectors (SC/SC)
or
1 x SC multi-mode connectors &
1 x coaxial BNC connectors (BNC/SC)
MADI Formats 56/64 channel, 48k/96k Frame, S/MUX 2
Sample Rates 44.1, 48, 88.2, 96 kHz +/-12.5%
Clock Inputs 1 x Word clock coaxial BNC (75 Ω
termination switchable)
This input also accepts an
AES3 frame (AES11).
Clock Output 1 x Word clock coaxial BNC
Mic/Line Inputs 4 x DSUB-25 (8 channels each)
phantom power switchable (+ 48 V)
PAD switchable (30 dB)
Line Outputs 4 x DSUB-25 (8 channels each)
GPO 2 x MOSFET switch
USB Port USB 2.0 port for firmware
updates and remote control.
Power Supply This device is equipped with two wide
range power supplies (84 V to 264 V
AC / 47 Hz to 63 Hz / safety class 1).

DirectOut Technologies
®
page 7 of 52© 2013 DirectOut GmbH D.O.TEC®ANDIAMO.MC Manual - Version 1.1
CHAPTER 1: Overview
Applications
ANDIAMO.MC can be used for conversion, amplifi cation, monitor-
ing and recording of analog and digital signals.
Typical applications include:
• recording mic / line signals (32 inputs)
• redundant recording using both MADI I/Os
• 1:2 splitting of analog input signals (input MADI & line out)
• monitoring a MADI signal (32 line outputs)
• signal distribution (routing matrix)
• daisy-chained use of two ANDIAMO.MCs for conversion of all
64 channels of a MADI signal
• ...

DirectOut Technologies
®
page 8 of 52 © 2013 DirectOut GmbHD.O.TEC®ANDIAMO.MC Manual - Version 1.1
CHAPTER 2: Legal issues & facts
CHAPTER 2: Legal issues & facts
Before Installing This Device
Warning
Please read and observe ALL of the following notes before
installing this product:
• Check the hardware device for transport damage.
• Any devices showing signs of mechanical damage or damage
from the spillage of liquids MUST NOT be connected to the
mains supply, or disconnected from the mains immediately by
pulling out the power lead.
• All devices MUST be grounded. The device is grounded
through its IEC power connections.
• All devices MUST be connected to the mains using the three-
cord power leads supplied with the system. Only supply
electrical interfaces with the voltages and signals described in
these instructions.
• Do NOT use the device at extreme temperatures. Proper op-
eration can only be guaranteed between temperatures of 5º C
and 45º C and a maximum relative humidity of 80 %, non-
condensing.
• The cabinet of the device will heat up. DO NOT place the de-
vice close to heating sources (e.g. heaters). Observe the envi-
ronmental conditions.
Defective Parts/Modules
Warning
This device contains no user-serviceable parts. Therefore do NOT
open the device.
In the event of a hardware defect, please send the device to your
D.O.TEC®representative together with a detailed description of the
fault.
We would like to remind you to please check carefully whether the fail-
ure is caused by erroneous configuration, operation or connection be-
fore sending parts for repair. See „CHAPTER 6: Troubleshooting and
Maintenance“ on page 39 for assistance with troubleshooting.

DirectOut Technologies
®
page 9 of 52© 2013 DirectOut GmbH D.O.TEC®ANDIAMO.MC Manual - Version 1.1
CHAPTER 2: Legal issues & facts
First Aid (in case of electric shock)
Warning
• DO NOT touch the person or his/her clothing before power
is turned off, otherwise you risk sustaining an electric shock
yourself.
• Separate the person as quickly as possible from the electric
power source as follows:
Switch off the equipment.
Unplug or disconnect the mains cable.
• Move the person away from the power source by using dry
insulating material (such as wood or plastic).
• If the person is unconscious:
Check their pulse and reanimate if their respiration is
poor.
Lay the body down and turn it to one side. Call for a doc-
tor immediately.
• Having sustained an electric shock, A LWAYS consult a doc-
tor.

DirectOut Technologies
®
page 10 of 52 © 2013 DirectOut GmbHD.O.TEC®ANDIAMO.MC Manual - Version 1.1
CHAPTER 2: Legal issues & facts
Contents
The contents of your ANDIAMO.MC package should include:
• 1 x ANDIAMO.MC (19’’, 2 RU)
• 2 x power chord
• 2 x fixing unit for power plug
• 1 x Hardware Guide
To complete the delivery please download from the DirectOut
website:
• Software Guide ANDIAMO Remote
• D.O.TEC®USB Serial driver
• ‘ANDIAMO Remote’ application
www.directout.eu/en/support/downloads/andiamo.mc.html
Accessories
D.O.TEC®BREAKOUT series
The BREAKOUT series are adaptor boxes - available in different
variants - to widen the application range of the D.O.TEC®ANDIAMO
series.
Each box is equipped with XLR connectors at the front panel and
DSUB-25 connectors at the rear panel. Audio signals are carried
passively between front and rear panel.
Three different models for analog signals are available:
BREAKOUT.AN8 - analog input / output, 8 channels
BREAKOUT.AN16I - analog input, 16 channels

DirectOut Technologies
®
page 11 of 52© 2013 DirectOut GmbH D.O.TEC®ANDIAMO.MC Manual - Version 1.1
CHAPTER 2: Legal issues & facts
BREAKOUT.AN16O - analog output, 16 channels

DirectOut Technologies
®
page 12 of 52 © 2013 DirectOut GmbHD.O.TEC®ANDIAMO.MC Manual - Version 1.1
CHAPTER 2: Legal issues & facts
Updates
D.O.TEC®products are continually in development, and therefore
the information in this manual may be superseded by new releases.
To access the latest documentation, please visit the DirectOut web-
site: www.directout.eu.
This guide refers to fi rmware version 1.2.
Intended Operation
The ANDIAMO.MC is designed for conversion of audio signals from
analog to digital and vice versa. In this context digital audio refers to
a MADI signal (AES10).
Warning
No compensation can be claimed for damages caused by operation
of this unit other than for the intended use described above. Con-
secutive damages are also excluded explicitly. The general terms
and conditions of business of DirectOut GmbH are applied.
Conditions of Warranty
This unit has been designed and examined carefully by the manu-
facturer and complies with actual norms and directives.
Warranty is granted by DirectOut GmbH over the period of two years
for all components that are essential for proper and intended opera-
tion of the device. The date of purchase is applied for this period.
Warning
All claims of warranty will expire once the device has been opened
or modified, or if instructions and warnings were ignored.
For warranty claims please contact the dealer where your device
was acquired.

DirectOut Technologies
®
page 13 of 52© 2013 DirectOut GmbH D.O.TEC®ANDIAMO.MC Manual - Version 1.1
CHAPTER 2: Legal issues & facts
Conformity&Certificates
CE
This device complies with the basic requests of applicable EU guide-
lines. The appropriate procedure for approval has been carried out.
RoHS
(Restriction of the use of certain Hazardous Substances)
This device was constructed fulfilling the directive on the restriction
of the use of certain hazardous substances in electrical and elec-
tronic equipment 2002/95/EC.
WEEE
(Directive on Waste Electrical and Electronic Equipment)
Due to the directive 2002/96/EC for waste disposal this device must
be recycled.
For correct recycling please dispatch the device to:
IMM Elektronik GmbH,
Leipziger Strasse 32
09648 Mittweida
Germany
Only stamped parcels will be accepted!
WEEE-Reg.-No. DE 93924963
Contact
Sales:
DirectOut GmbH, Leipziger Strasse 32, 09648 Mittweida, Germany
Phone: +49 (0)3727 6205-333 // Fax: +49 (0)3727 6205-56
www.directout.eu
Manufacturer:
IMM Elektronik GmbH, Leipziger Strasse 32, 09648 Mittweida,
Germany
Phone: +49 (0)3727 6205-0 // Fax: +49 (0)3727 6205-56
www.imm-gruppe.de

DirectOut Technologies
®
page 14 of 52 © 2013 DirectOut GmbHD.O.TEC®ANDIAMO.MC Manual - Version 1.1
CHAPTER 3: Installation
CHAPTER 3: Installation
Installing the Device
1. Open the packaging and check that the contents have been
delivered complete and undamaged.
2. Fix the device in a 19’’ frame with four screws, or place it on
a non-slip horizontal surface.
Warning
Avoid damage from condensation by waiting for the device to adapt
to the environmental temperature. Proper operation can only be
guaranteed between temperatures of 5º C and 45º C and a maxi-
mum relative humidity of 80%, non-condensing.
Ensure that the unit has suffi cient air circulation for cooling.
3. Remove the protective cap from the optical MADI port(s)
before use.
Retain the protective cap if the optical port is unused. This will pro-
tect against soiling which can lead to malfunction.
4. Connect signal cable for the MADI signals.
ANDIAMO.MC- SC / SC version (optical / optical)
ANDIAMO.MC- SC / BNC version (optical / coaxial)

DirectOut Technologies
®
page 15 of 52© 2013 DirectOut GmbH D.O.TEC®ANDIAMO.MC Manual - Version 1.1
CHAPTER 3: Installation
5. Connect the signal cables1for the analog audio signals to
the DSUB-25 connectors (TASCAM pinout - see page 43).
1 signal cables are not included in delivery
7. Using the power cords provided connect both PSUs to a
matching power supply:
6. Optional: Connect an USB cable to the USB port for remote
control or fi rmware updates. This requires the D.O.TEC® USB
driver (Windows) being installed fi rst. The driver and the instal-
lation instructions are available at www.directout.eu.
Link: http://www.directout.eu/en/support/downloads/andiamo.mc.html
Warning
Do not connect voltage sources to the analog outputs. This may
cause damage at the output stages. Observe the technical specifi -
cations - see „CHAPTER 7: Technical Data“ on page 40.
Warning
This device MUST be connected to the mains using the three-cord
power leads supplied with the system. Only supply the voltages and
signals indicated (84 V – 264 V).
This device may operate with only one power supply. To provide
power supply redundancy, it is recommended to connect both PSU 1
and PSU 2 to independent power supplies with separate fuses.

DirectOut Technologies
®
page 16 of 52 © 2013 DirectOut GmbHD.O.TEC®ANDIAMO.MC Manual - Version 1.1
CHAPTER 3: Installation
Keep any packaging in order to protect the device should it need to
be dispatched for service.
The fi rst seconds after switch-on the actual fi rmware is indicated by
the lower metering panel - e.g. fi rmware version 1.2.
To update the fi rmware an installed D.O.TEC® USB Serial driver (Win-
dows) and the D.O.TEC® Update Tool are necessary. The software
and the installation instructions are available at www.directout.eu.
Link: http://www.directout.eu/en/support/downloads/andiamo.mc.html
8. Turn on the power switch and check the status of PSUs on
the front panel:
Use the D.O.TEC® Release Map to match your D.O.TEC® device
with the latest fi rmware or software release.
Link: http://www.directout.eu/upload/dokumente/dotec_release_map.pdf

DirectOut Technologies
®
page 17 of 52© 2013 DirectOut GmbH D.O.TEC®ANDIAMO.MC Manual - Version 1.1
CHAPTER 3: Installation
9. Installation of D.O.TEC® USB Serial driver
• download the D.O.TEC® USB Serial driver
• download the ‘Installation Guide for USB Control’
Link: http://www.directout.eu/en/support/downloads/andiamo.mc.html
• follow the installation instructions in the ‘Installation Guide for
USB Control’
10. Installation of ‘ANDIAMO Remote’
• download the ‘Software Guide ANDIAMO Remote‘
• download the ‘ANDIAMO Remote’ application
Link: http://www.directout.eu/en/support/downloads/andiamo.mc.html
• follow the installation instructions in the ‘Software Guide AN-
DIAMO REMOTE’
11. Start the ‘ANDIAMO Remote’ application
• Check selected COM port or MIDI I/O
• Click ‘CONNECT’

DirectOut Technologies
®
page 18 of 52 © 2013 DirectOut GmbHD.O.TEC®ANDIAMO.MC Manual - Version 1.1
CHAPTER 4: Operation
CHAPTER 4: Operation
Introduction
This chapter describes the basic operation of the device. Note that
throughout this manual, the abbreviation FS refers to sample rate or
sample frequency. So, when dealing with scaling factors, the follow-
ing sample rates can be written as:
• 44.1 kHz = 1 FS; 88.2 kHz = 2 FS
or
• 48 kHz = 1 FS; 96 kHz = 2 FS
Global Control
The control on the right of the front panel indicates the power supply.
Power switches are on the back panel:
Power 2 Switches
Enable / disable power supply.
PSU 1 & PSU 2 2 LEDs (green): indicate the status
of both power supply units
LED OFF = Power supply inactive
LED ON = Power supply active
The green LEDs (PSU 1 & PSU 2) indicate that a working power
supply is connected to the power supply unit. Note that an unlit LED
does not guarantee that the device is free of voltage. To ensure
that the device is completely disconnected from mains voltage, the
power chords must be disconnected.

DirectOut Technologies
®
page 19 of 52© 2013 DirectOut GmbH D.O.TEC®ANDIAMO.MC Manual - Version 1.1
CHAPTER 4: Operation
Menu Control
All functions of the converter can be accessed using a simple menu.
Two pairs of push buttons are used for navigation and settings.
The upper pair is used to modify a setting. The lower pair is used to
navigate the menu.
SET Buttons - ▲▼
Press to adjust a setting. Only
active in menu mode.
SELECT Buttons - ▲▼
Press longer than 2 seconds to
enter the menu. Press short for
navigation in menu mode.
When the menu mode is active a LED will blink in one of the sec-
tions while the remaining LEDs of this section are glowing weak.
This indicates:
• a setting can be adjusted in this section
• the blinking LED(s) is the selected option in this section
After a short period of time the menu mode is exit automatically.
See also „CHAPTER 5: Menu Navigation“ on page 34.
Blinking LEDs are also used to indicate an error (e.g. missing sync).
Concentrate on the section where one LED is blinking and the re-
maining LEDs are glowing weak.

DirectOut Technologies
®
page 20 of 52 © 2013 DirectOut GmbHD.O.TEC®ANDIAMO.MC Manual - Version 1.1
CHAPTER 4: Operation
Clocking
The system clock can be set to one of three possible clock sources
in the menu (see „CHAPTER 5: Menu Navigation“ on page 34).
The LEDs on the front panel inform about selection and sync state
of the selected source.
75Ω LED (yellow): indicates the termination
status of the word clock input
LED ON = Termination active
LED OFF = Termination inactive
WCK LED (green): indicates use of
word clock as clock source
LED ON = Clock source set to word clock
LED blinking = Clock source
set to word clock and no signal present
LED blinking pattern = signal
locked but not in sync
MADI LED (green): indicates use of
MADI input as clock source
LED ON = Clock source set to MADI input
LED blinking = Clock source
set to MADI input and no signal present
INT LED (green): indicates use of internal
clock generator as clock source
LED ON = Clock source
set to internal clock generator
Other manuals for ANDIAMO.MC
1
Table of contents