Distech Controls Allure EC-Sensor-T Manual

www.distech-controls.com
1/3
1. Product Description
This document describes the hardware installation procedures for the Allure
EC-Sensor-T (temperature only); a space temperature sensor, inside an Allure
enclosure (Figure 1-1), used to monitor room temperature.
The Allure EC-Sensor-T’s modern, alluring profile enclosure is suitable for
classrooms, hotels, executive areas, office spaces and other commercial
areas. It consists only of a temperature sensor (thermistor), approximately
4.75 inches (12 cm) of wire and a clip with adhesive inside the enclosure
(Figure 1-2).
Mounting hardware with a separate sub-base is provided with the device for
installation on a dry wall or on an electrical junction box.
Figure 1-1: Allure EC-Sensor-T space temperature sensor
Figure 1-2: Inside the Allure EC-Sensor-T enclosure - temperature sensor
(thermistor), approximately 4.75 inches (12 cm) of wire and a clip to hold
thermistor/wire in place.
Hardware Installation Guide
Allure™EC-Sensor-T:
Space temperature sensor

Total Quality Commitment
All Distech Controls product lines are built to meet rigorous quality standards. Distech Controls is an ISO 9001 registered company.
©, Distech Controls Inc., 2013. All rights reserved. Specifications subject to change without notice.
While all efforts have been made to verify the accuracy of information in this manual, Distech Controls is not responsible for damages or claims arising from the use of this manual. Persons
using this manual are assumed to be trained HVAC specialist / installers and are responsible for using the correct wiring procedures and maintaining safe working conditions with fail-safe
environments. Distech Controls reserves the right to change, delete or add to the information in this manual at any time without notice.
Distech Controls, the Distech Controls logo, Innovative Solutions for Greener Buildings, and Allure are trademarks of Distech Controls Inc. All other trademarks are property of their
respective owners.
2/3
2. General Installation Requirements
For proper installation and subsequent operation of the Allure EC-Sensor-T
sensor, pay special attention to the following recommendations:
- Upon unpacking the product, inspect the contents of the carton for
shipping damages. Do not install damaged sensors.
- Allow for proper clearance of device enclosure and wiring terminals for
easy access, hardware configuration and maintenance.
- The device is designed to operate under the following environmental
conditions:
Operating temperature from 32°F to 122°F (0°C to 50°C)
Storage temperature from -4°F to 158°F (-20°C to 70°C)
Relative humidity from 0% to 90%, non-condensing.
- Ensure proper ventilation of device and avoid areas where corroding,
deteriorating or explosive vapors, fumes or gases may be present. The
device must be oriented with the ventilation slots towards the top.
Any type of modification to any Distech Controls product will
void the product’s warranty.
3. General Wiring Recommendations
- All wiring must comply with electrical wiring diagrams as well as
national and local electrical codes.
- Use the screws, wall anchors, and wire nuts included for wall mounting
and wiring.
Turn off power before any kind of servicing.

3/3
Allure EC-Sensor-T_IG_10_EN
4. Mounting Instructions
The Allure EC-Sensor-T sensor has been specially designed for easy
installation. However, certain conditions apply when choosing a suitable
location for the device:
- Install the device in a location of average temperature approximately 5
ft (1.5 m) above the floor
- The device should not be installed on an exterior wall.
- The device should not be installed near a heat source.
- The device should not be installed near an air discharge grill.
- The device should not be installed in a place where it can be affected by
the sun.
- Install the device in an area that provides proper device ventilation.
Nothing must restrain air circulation to the device.
The Allure EC-Sensor-T sensor has not been designed for
outdoor use.
Wall Mounting Installation Procedure
The Allure EC-Sensor-T sensor can be mounted on a dry wall using supplied
screws.
1. Remove the security screw from the device (Figure 5-1).
2. Open the device by pressing in the two (2) tabs on the bottom of the
device and pulling the bottom side of the front plate out.
3. Pull all cables 6” (15cm) out of the wall, and insert them through the
central hole of the back plate.
4. Align the back plate with the wall and mark the location of the mounting
holes on the wall. Make sure to orient the proper side of the back plate
facing upwards.
5. Remove the back plate and drill holes in the wall if necessary.
6. Install anchors in the wall if necessary.
7. Make sure that the mounting surface is flat and clean.
8. Screw the back plate onto the wall. Do not over tighten.
9. Strip each wire if needed and connect each one according to the wiring
diagram shown in this document (Figure 7-1).
10. Gently push excess wiring back into the wall.
11. Reattach the front plate and make sure it clips tightly into place.
12. Install security screw.
Electrical Junction Box Installation Procedure
The Allure EC-Sensor-T sensor can be mounted in most American, European
or Asian style electrical junction box using screws.
1. Remove the security screw from the device (Figure 5-1).
2. Open the device by pressing in the two (2) tabs on the bottom of the
device and pulling the bottom side of the front plate out.
3. Pull all cables 6” (15cm) out of the wall, and insert them through the
central hole of the back plate.
4. Screw the back plate onto the electrical junction box.
5. Strip each wire if needed and connect each one according to the wiring
diagram shown in this document (Figure 7-1).
6. Gently push excess wiring back into the electrical junction box.
7. Reattach the front plate and make sure it clips tightly into place.
8. Install security screw.
5. Device Components
Wall anchors
Security screw
ß
To temperature sensor
Figure 5-1: Mounting an Allure EC-Sensor-T
6. Device Dimensions
Figure 6-1: From top left to bottom: Front view, back plate, side view
7. Device Wiring
Wiring the Thermistor
The 10kΩ type 2 NTC thermistor is connected to the controller in the
following manner using the wire nuts included with the Allure EC-Sensor-T:
UI
COM
Controller Input
Internal NTC Thermistor 10kΩ
Figure 7-1: 10kΩ Type 2 NTC Thermistor Wiring
26.83
(1.06)
Unit Legend:
mm (inches)
Other Distech Controls Temperature Controllers manuals
Popular Temperature Controllers manuals by other brands

Seltron
Seltron ACC40 user manual

Elko
Elko RFTC-10/G Assembly instruction and manual

t.a.c.
t.a.c. TS-8101 General instructions

Ecom Instruments
Ecom Instruments Ex-Pt 720 operating instructions

S+S Regeltechnik
S+S Regeltechnik AERASGARD RFTM-PS Series Operating Instructions, Mounting & Installation

Hanshin
Hanshin Smart Thermal Detector user manual