Dixon FloTech FT201-12 Operating and maintenance manual

10154 Feb 2010
5204 ...................... fixed handle, with sight glass
5204C.................... detachable handle, with sight glass
5204NG................. fixed handle, no sight glass
5204NGC.............. detachable handle, no sight glass
5204T.................... fixed handle, with sight glass, Teflon seals, SS spring
5204TC ................. detachable handle, with sight glass, Teflon seals, SS spring
5204NGT .............. fixed handle, no sight glass, Teflon seals, SS spring
5204NGTC............ detachable handle, no sight glass, Teflon seals, SS spring
5204B.................... fixed handle, sight glass, Bayloy nose ring
5204BC................. detachable handle, with sight glass, Bayloy nose ring
5204BNG.............. fixed handle, no sight glass, Bayloy nose ring
5204BNGC ........... detachable handle, no sight glass, Bayloy nose ring
5204SNG……… …fixed handle, no sight glass, stainless steel main spring
5204NGV…………fixed handle, no sight glass, Poppet O-ring, for B100
5204NGCV ........... detachable handle, no sight glass, Poppet O-ring, for B100
5204BNGV.........fixed handle, no sight glass, Bayloy nose ring, Poppet O-ring, for B100
5204BNGCV......detachable handle, no sight glass, Bayloy nose ring, Poppet O-ring, for B100
5204SNGV …… …fixed handle, no sight glass, stainless steel main spring, Poppet O-ring, for B100
5204P.................... fixed handle, with sight glass, drain plug
Maintenance & Operating Instructions
For
FloTech
Red & Black 2 Wire Retain / Overfill Compatible Optic Sensors
Part Numbers
FT201
FT201-12
FT201-18
FT202
FT202-12
FT202-18
FT206
USA:
Dixon Bayco USA
Chestertown, Maryland
Phone: 410-778-2000
Fax: 410-778-4702
Toll Free: 800-355-1991
E-mail: [email protected]om
www.dixonbayco.com
Canada:
Dixon Group Canada Limited
Innisfil (Barrie), Ontario
Phone: 705-436-1125
Fax: 705-436-6251
Toll Free: 877-963-4966
E-mail: [email protected]
www.dixongroupcanada.com
Mexico:
Dixva, S. de R.L. de C.V.
Monterrey, N.L
Phone: 01-800-00-DIXON (34966)
Fax: 01-81-8354-8197
E-mail :[email protected].mx
www.dixonvalve.com
Europe:
Dixon Group Europe Ltd
Preston, England
Phone: +44 (0)1772 323529
Fax: +44 (0)1772 314664
E-mail: [email protected]
www.dixoneurope.co.uk
Asia Pacific:
Dixon (Asia Pacific) Pty Ltd
Wingfield, South Australia
Phone: +61 8 8202 6000
Fax: +61 8 8202 6099
E-mail:[email protected].au
www.dixonvalve.com.au
For Sales & Service Contact

10154 Feb 2010
PRODUCT DESCRIPTIONS:
These instructions cover the following FloTech product:
FT201 Replacement 2 wire Optic Overfill Probe
FT202 2 wire Optic Overfill Sensor with 2”NPT Probe Holder
FT206 2 Wire Optic Retain Sensor with ½” NPT Probe Holder
FloTech FT201 and FT202 are mechanically and functionally compatible with Civacon R/M
models 1350 and 1050 ROM 2 wire optic sensors. FloTech FT206 sensor is compatible with
Civacon ROM models 1000 series. “Civacon” and “ROM” are registered trademarks of
Civacon / Dover Corporation.
INSTALLATION INSTRUCTIONS:
FloTech model FT202 can be mounted in a 2”NPT female pipe coupling or through a 2 3/8”
hole. When mounting in a 2 3/8” hole the gasket and lock nut provided are used to retain the
probe holder in the tank shell or manhole. After the sensor is mounted remove the cap.
Loosen the probe clamp screw and adjust the probe to the correct level point. This is typically
3% of compartment volume. It is not recommended cutting the standard 7” sensor to a shorter
length. This will cause insufficient time to stop the flow of product within the load racks
reaction time.
IMPORTANT: The actual sensing point adjustment should be determined by the total
response time required to prevent a tank overfill condition. The FloTech sensor reaction time
is one half second. The loading rack will also have a reaction time. Once the probe is adjusted
to the proper height, tighten the clamp screw.

10154 Feb 2010
RETAIN SENSOR:
FloTech model FT206 is designed to fit into a ½ NPT half coupling welded into the bottom of each
compartment. The mounting location should be the lowest point of the tank. The collar should not protrude
more than ¾ inch outside the tank and flush with the inside of the tank when possible. FloTech supplies a ½
NPT weld coupling with each sensor. The coupling requires a 1 1/8 inch diameter hole cut in the bottom of
the tank. After the welded coupling has cooled, install the sensor using pipe sealant or Teflon tape to
lubricate and seal the threads. NOTE: Check thread engagement to ensure the retain sensor prism tip is set
deep enough into the tank as to clear weld collar.
NOTE: DO NOT USE THE BODY OF THE SENSOR TO TIGHTEN!
RETAIN SENSOR
NEED ASSISTANCE? CALL 877-582-3569
DIXON WARRANTY:
For Warranty Information, please refer to the inside back cover of the latest Dixon
Petroleum/Overfill Detection catalog.

10154 Feb 2010(fr)
5204 ...................... fixed handle, with sight glass
5204C.................... detachable handle, with sight glass
5204NG................. fixed handle, no sight glass
5204NGC.............. detachable handle, no sight glass
5204T.................... fixed handle, with sight glass, Teflon seals, SS spring
5204TC ................. detachable handle, with sight glass, Teflon seals, SS spring
5204NGT .............. fixed handle, no sight glass, Teflon seals, SS spring
5204NGTC............ detachable handle, no sight glass, Teflon seals, SS spring
5204B.................... fixed handle, sight glass, Bayloy nose ring
5204BC................. detachable handle, with sight glass, Bayloy nose ring
5204BNG.............. fixed handle, no sight glass, Bayloy nose ring
5204BNGC ........... detachable handle, no sight glass, Bayloy nose ring
5204SNG……… …fixed handle, no sight glass, stainless steel main spring
5204NGV…………fixed handle, no sight glass, Poppet O-ring, for B100
5204NGCV ........... detachable handle, no sight glass, Poppet O-ring, for B100
5204BNGV.........fixed handle, no sight glass, Bayloy nose ring, Poppet O-ring, for B100
5204BNGCV......detachable handle, no sight glass, Bayloy nose ring, Poppet O-ring, for B100
5204SNGV …… …fixed handle, no sight glass, stainless steel main spring, Poppet O-ring, for B100
5204P.................... fixed handle, with sight glass, drain plug
Entretien & Mode d’emploi
pour
FloTech
Rouge & Noir- 2 brins capteur de fond / Sonde optique
compatible avec système anti-débordement
FT201 Sonde de remplacement 2 brins Optique Anti-Débordement
FT202 Sonde 2 brins avec boitier 2” NPT
FT206 Sonde de fond avec boitier ½” NPT
E-U:
Dixon Bayco USA
Chestertown, Maryland
Téléphone: 410-778-2000
Fax: 410-778-4702
Sans frais: 800-355-1991
E-mail: dixonbayco@dixonvalve.com
www.dixonbayco.com
Canada:
Dixon Group Canada Limited
Innisfil (Barrie), Ontario
Téléphone: 705-436-1125
Fax: 705-436-6251
Sans frais: 877-963-4966
E-mail: isales@dixongroupcanada.com
www.dixongroupcanada.com
Mexique:
Dixva, S. de R.L. de C.V.
Monterrey, N.L
Téléphone: 01-800-00-DIXON (34966)
Fax: 01-81-8354-8197
E-mail :contactenos@dixonvalve.com.mx
www.dixonvalve.com
Europe:
Dixon Group Europe Ltd
Preston, England
Téléphone: +44 (0)1772 323529
Fax: +44 (0)1772 314664
E-mail: enquiries@dixoneurope.co.uk
www.dixoneurope.co.uk
Asie et Pacifique:
Dixon (Asia Pacific) Pty Ltd
Wingfield, South Australia
Téléphone: +61 8 8202 6000
Fax: +61 8 8202 6099
E-mail:enquiries@dixonvalve.com.au
www.dixonvalve.com.au
Pour vente et service contactez

10154 Feb 2010(fr)
Les FT201 et les FT202 FloTech sont mécaniquement et fonctionnellement compatibles avec
les capteurs optiques Civacon modèles à 2 brins R/M 1350 et 1050 ROM à 2 brins avec
capteur optique. La sonde de fond FT206 FloTech est compatible avec le modèle 1000
Civacon ROM. “Civacon” et “ROM” sont des marques de commerces de la corporation
Civacon / Dover.
INSTRUCTIONS D’INSTALLATION:
Le modèle FT202 FloTech peut être vissé dans le coupleur femelle de tuyau de 2” NPT ou
installé dans un trou de 2 3/8”. Lorsque vous l’installez dans le trou de 2 3/8” le joint
d’étanchéité et l’écrou de blocage sont fournis pour retenir le support de la sonde dans la
citerne ou dans le trou d’homme. Après avoir installé le capteur retirez le couvercle.
Desserrez la vis de serrage de la sonde et ajustez la sonde au niveau approprié. Nous ne
recommandons pas de couper la sonde de 7” plus courte. Cela pourrait nuire aux rampes de
chargements et arrêter le débit du produit dans la durée temps alloué Les sondes de 12” et de
18” peuvent être coupée plus courtes.
Instructions pour couper les sondes :
1) Retirez le protecteur noir pour de filets.
2) Mesurez la nouvelle longueur de la sonde. La sonde devrait être réglée pour un
minimum de 60 gallons ou 250 litres d’espace dans la citerne après que la sonde soit
mouillée.
3) Tenez la sonde dans une main lorsque vous la couper en utilisant un coupe tube. Ne
mettez pas le capteur dans un étau. Cela endommagera le capteur.
4) Coupez le tube en utilisant un coupe tube. N’utilisez pas une scie. Ne coupez pas le
tube plus court que 7”.
5) Remettez le protecteur pour filets.
IMPORTANT: Le réglage du point réel de détection doit être déterminé par le temps de
réponse total nécessaire pour éviter qu’une situation de débordement de la citerne. Le temps de
réaction du capteur FloTech est d’une demie seconde. La rampe de chargement aura aussi un
temps de réaction. Une fois que la sonde sera ajustée à la bonne longueur, serrez la vis de la
serrage.

10154 Feb 2010(fr)
CAPTEUR DE FOND
Le capteur de retenu modèle FT206 FloTech est conçu pour un coupleur NPT ½ ” soudé sur le dessous de
chaque compartiment. L’endroit pour l’installation devrait être sur le point le plus bas de la citerne. Le col
ne devrait jamais dépasser plus que ¾” à l’extérieur de la citerne et devrait être égale avec l’intérieur du
réservoir si possible. Dixon fourni un coupleur de soudure de ½”NPT avec chaque capteurs. Le coupleur
exige qu’un trou avec un diamètre de 1 1/8” soit coupé sur le dessous de la citerne. Après que
l’accouplement soudé soit refroidi, installez le capteur en utilisant un produit d’étanchéité à raccord ou du
ruban téflon pour lubrifier et sceller les filets. NOTE: Vérifiez les filets pour vous assurez que le bout du
prisme du capteur de fond soit assez profond dans la citerne.
NOTE: N’UTILISEZ PAS LE CORPS DU CAPTEUR POUR LE SERRER!
CAPTEUR DE FOND
BESOIN D’ASSISTANCE ? APPELEZ LE
877-582-3569
GARANTIE DIXON: Pour plus d’informations complètes sur la garantie, s’il vous plait se référer à la
couverture intérieure de la dernière page du dernier catalogue Dixon.
This manual suits for next models
6
Table of contents
Languages:
Other Dixon Accessories manuals
Popular Accessories manuals by other brands

Skoda
Skoda OCTAVIA - ANNEXE 338 brochure

DOMUS LINE
DOMUS LINE PYBOX installation manual

eDecks
eDecks King Edward Fitting instructions

Philips
Philips CRP416 brochure

American Standard
American Standard Acrylux 32"x 32" Shower Wall Set 3232Y1.SW Specification sheet

Panasonic
Panasonic LS-H Series instruction manual