GX360
360 deg ceiling PIR with Audio detection
INSTALLATION AND OPERATING INSTRUCTIONS
FORWARD
The GX360 is a 12 volt DC ceiling passive detectors with the addition of Audio detection. Up to four (4) GX360 detectors may be
connected to one (1) DX360 control unit. Four core alarm or telephone cable is used to wire the detectors to the control unit.
The DX360 produces 12 volts DC for the GX360 detectors and switches mains voltage up to 3KW of incandescent lighting or
2KW of fluorescent lighting.
A light sensor which is built in to the GX360 detectors inhibits the DX360 from turning the lights ON if the room is too bright.
The DX360 can only be initiated by PIR detection but once activated, sound detection will keep the lights ON. This is especially
useful in offices where people sit very still or are obscured by furniture. The sound of speech or typing on a key board will be
sufficient to maintain detection.
FIXING
The GX360 can be fitted to a wall or ceiling where it will view 360
degrees to cover the appropriate area. The range is variable up to
12 metres. As the GX360 detector also detects sound, it is
important to fit the detector on a solid surface with limited vibration.
Any vibration will be picked up by the detector and cause it to keep
the lighting ON. An audio sensitivity control is provided to reduce
this detection or disable it altogether.
3 4 5 6 7 8 9 10 11 12
- + LS T - + LS T
DX360
TECHNICAL HELPLINE 0181 3615255
LUMINITE Electronics LTD
2a Bellevue Road, Friern Barnet
LONDON N11 3ER
Tel: 0181 3687887 Fax: 0181 3683952
www.luminite.co.uk
SPECIFICATION
•Input voltage 12 volts DC
•Power consumption 15 m/a
•Detector output voltage 3-12 volts DC
•Audio sensitivity Adjustable
•PIR sensitivity Adjustable
GX360 GX360 etc.
Fig 1
DETECTOR WIRING
The detectors may be wired in a chain or alternatively wired back
separately to the control unit using 4 core alarm cable (7/2/4) or
telephone cable. The wiring example in Fig 1 shows two detectors
wired to one DX360. Up to four (4) detectors may be connected to
one DX360 control unit.
All GX360 detectors have built in light sensors but only one is required
for each DX360 control unit as shown.
COMMISSIONING.
Set the DX360 for walk test. Allow about two minutes for the
detectors to settle before beginning the tests. Turn both audio and
PIR sensitivity controls to maximum. Each time movement or sound
is detected by the GX360’s the red trigger indicator will light. In
addition the room lights will come on for about 20 seconds. Walk about
within the detection area to make sure you are satisfied with the
coverage. Try to keep quiet when walk testing or turn the audio
detection control on the GX360 down to minimum. When satisfied
with the set up, set the DX360 up for normal use. See separate
DX360 instructions.
TROUBLE SHOOTING
PROBLEM Lights remain ON
SOLUTION Look at the detector and observe the red
detection indicator. In a quiet room
without movement this indicator should
not light. If it does, turn the AUDIO
sensitivity control down as it may be
picking up vibration from the ceiling.
Turning this control down fully stops the
audio detection altogether.
If the problem persists, turn down the PIR
sensitivity as well.
If both the above methods fail, try
removing the trigger wire from terminal 5.
The lights must turn off after the
set time period. If they do not, check the
wiring for Live In and Live Out to make
sure they are the correct way round.
Optional over-ride switch
Lens Information
Mounting height Sensing
Above floor diameter
6.0m 15.2m
5.4m 14.0m
4.8m 12.6m
4.2m 11.6m
3.6m 10.4m
3.0m 9.2m
2.7m 8.6m
2.4m 8.0m
At 2.4m
Ceiling height
4.0m 4.0m
7.6m
At 2.4m
Ceiling height
At 2.4m ceiling height
the detectors cover a
radius of 4 metres.
(Diameter 8 metres)
To cover a large area it will be
necessary to use more than one
detector as shown. Detector
coverage should overlap for best
results.
DX360
Lighting
Control Unit
Mains IN
220-240V
50Hz
To
Lighting
Max 2KW
Resistive
4 core cable

Popular Security Sensor manuals by other brands

Trocen AWC78 Series user manual

Trocen

Trocen AWC78 Series user manual

IKEA TRÅDFRI E1745 manual

IKEA

IKEA TRÅDFRI E1745 manual

HELVAR Digidim 317 manual

HELVAR

HELVAR Digidim 317 manual

Evikon PluraSens E2638-LEL user manual

Evikon

Evikon PluraSens E2638-LEL user manual

Amprobe ULD-405 user manual

Amprobe

Amprobe ULD-405 user manual

Honeywell FIRE-LITE ALARMS SD365CO Installation and maintenance instructions

Honeywell

Honeywell FIRE-LITE ALARMS SD365CO Installation and maintenance instructions

Lince 1597ZENITHDT Programming and operating manual

Lince

Lince 1597ZENITHDT Programming and operating manual

Aritech EV1116 Series Installation sheet

Aritech

Aritech EV1116 Series Installation sheet

IGM Vega FD 330-4-1 user manual

IGM

IGM Vega FD 330-4-1 user manual

Nice LP21 User, installation and safety instructions

Nice

Nice LP21 User, installation and safety instructions

Baumer URDK 10P8914/S35A quick start guide

Baumer

Baumer URDK 10P8914/S35A quick start guide

teko Astra-531 AC User instruction

teko

teko Astra-531 AC User instruction

Versahaul VH-SR quick start guide

Versahaul

Versahaul VH-SR quick start guide

Dors 1300 user manual

Dors

Dors 1300 user manual

Fieldpiece ACM4 Operator's manual

Fieldpiece

Fieldpiece ACM4 Operator's manual

BEA FALCON EXXL manual

BEA

BEA FALCON EXXL manual

Code 3 Z3 Series Installation & operation manual

Code 3

Code 3 Z3 Series Installation & operation manual

Sonoff SNZB-P user manual

Sonoff

Sonoff SNZB-P user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.