4
Dimensions 123 x 70 x 50mm
Mounting height 2.1m (Min) ~ 3.1m(Max)
Coverage 12m x 12m @ 90°
PIR Detector zones 20 dual element zones
Pulse count Selectable 1~2 or 3~4
Microwave Range Selectable Low/High
Pet Immunity Single pet up to 25kg or multi-
ple pets up to 15kg total
PIR Sensor Dual element pyroelectric
Microwave frequency 10.525 GHz
Visual display Green: PIR LED
Amber: Microwave LED
Red: Alarm LED
Alarm period 2 seconds
Warm up period 60 seconds
Alarm output Normally Closed relay (fail
safe) dry contacts with 47
Ohm resistor in series
Tamper output Normally Closed dry contacts
with 47 Ohm resistor in series
Operating voltage 9~15V DC
Current draw 20mA, (28mA Walk Test)
Operating temperature 0~50°C
Operating humidity Up to 95% Relative Humidity
(non condensing)
sPecIFIcatIonsProgram lInks
COUNT:
COUNT link selects two pulse count positions.
COUNT LINK ON: 1~2 Pulses or walk steps should cause
an alarm.
COUNT LINK OFF: 3~4 Pulses or walk steps should
cause an alarm.
DOCUMENT PART NUMBER 890-258
For products: 100-694 Ness Pet Aware DUAL
© 2011 Ness Corporation Pty Ltd ABN 28 069 984 372
Specifications may change without notice.
The COUNT link MUST be in the OFF
position when protecting an area with
a pet weighing MORE than 10kg.
MICROWAVE RANGE:
The MICROWAVE RANGE rotary control (VR1) selects
low~high microwave range.
ANTICLOCKWISE: Decrease microwave range
CLOCKWISE: Increase microwave range
The MICROWAVE RANGE control should be set to the
minimum setting that will adequately cover the protected
area.
LEDS:
The LEDS link disables all LEDs. Default position is ON.