Dome Sx User manual

Dome®Sx Display
User’s Guide

© 2012 NDS Surgical Imaging. All rights reserved.
Information in this document has been carefully checked for accuracy; however, no
guarantee is given to the correctness of the contents. This document is subject to
change without notice. Go to web site ndssi.com for the latest documentation.
NDSsi provides this information as reference only. Reference to products from other
vendors does not imply any recommendation or endorsement.
This document contains proprietary information protected by copyright. No part of
this manual may be reproduced by any mechanical, electronic, or other means, in
any form, without prior written permission of NDSsi.
NDS Surgical Imaging, NDSsi, the NDSsi logo, Dome, the Dome by NDSsi logo,
Dome S3, Dome S3c, Dome S10, Dome CXtra, RightLight are either registered or
unregistered trademarks of NDS Surgical Imaging. All other trademarks are the
property of their respective owners.
020-0904 Rev02A

About the Display
The Dome® Sx displays are available in 3 and 10 megapixels and
contain a TFT LCD panel. The display’s thin film transistors, in
a transmissive-type display, use an integrated cold cathode
fluorescent tube (CCFT) backlight system.
The display is designed for medical imaging in diagnostic settings and
comes fully tuned with gamma correction that complies with the
DICOM Part 14 Standard. The all-digital design enables the display to
produce the sharp, crisp images critical to softcopy medical viewing.
Unwanted analog display image artifacts are eliminated.
For display classification and use; environmental guidelines; safety
precautions; handling, cleaning and storage tip; and specifications,
see “Technical Information” on page 7.
System Requirements
• Windows 7 (x86 or x64) or Windows XP Service Pack 3 (x86 or x64)
• Intel or AMD multi-core processor
• PCI Express x16 lane slot
• 50 MB hard disk space
•512MBRAM
•CD-ROMdrive
• Power supply, 350 watts or greater

2 | Dome Sx Display
NOTE: DVI-to-DVI and DisplayPort cables ship in the Dome S3 and Dome S3c display packages. DVI and mini USB
cables ship in the Dome S10 display package.
The Dome S10 display, shown here for illustrative purposes. Your display package
may contain a Dome S3, Dome S3c, or Dome S10 unit.
DC power adapter Power cord
DVI cable DisplayPort cable Mini USB cable Quick reference

About the Display | 3
Display Components
Review the following illustrations to identify controls and ports on
the front and back panels of the Dome Sx displays.
The sensor on the front of the Dome S3 and Dome S3c displays allows
you to run an auto-conformance test without using a photometer.
The MQSA (Mammography Quality Standards Act) button (lower
right, beneath display ID) on the Dome S10 display facilitates any
daily, weekly, or annual tests that you have preset via calibration and
monitoring software.
Front sensor on Dome S3/Dome S3c MQSA button on Dome S10

4 | Dome Sx Display
The Dome Sx displays include the following components on
the connector plate:
•Powerinput.
– On Dome S3, drives power to the display via an 8-pin
DIN connector. The power input is 12V ±5% (130 W).
– On Dome S3c and Dome S10, drives power to the display via
a 6-pin DIN connector. The power input is 24V ±5% (150 W).
•USBport.
– Dome S3/Dome S3c uplink B port. Usage to be defined at
a future time.
– Dome S10 uplink mini-B port. Usage assigned for MQSA
button functionality.
• Video input. Drives the data to the display.
– The Dome S3/Dome S3c display offers two video connector
options: a standard DVI connector or a DisplayPort connector.
– The Dome S10 display offers two standard DVI connectors.
• Reset button. Restores the display configuration to default
setting.
• LED lights. Provides information on the status of the display.
Dome S3/Dome S3c
connector plate
Dome S10
connector plate

Installing the Display | 5
Installing the Display
Turn your computer off. Leave the power cord plugged into the
grounded outlet. Use the Dome Sx display with the power
adapter and video cable shipped.
Connecting the Video and Power Cables
IMPORTANT! For the Dome S3 or Dome S3c display only. Install either
the DVI or the DisplayPort video cable, not both.
To connect the cables
1 Plug one end of the video cable into the video port on
the connector plate. Secure the connection.
2 Plug the power cord into the power input port on the
connector plate.
3 Plug the other end of the cable into the video port on your
computer system. Secure the connection.
4 Plug the other end of the power cord into the power supply.
5 Plug the power supply cord(s) into a grounded AC outlet.
6 Turn on the adapter power before you turn on the computer.
Warning
In locations where 240V outlets are used, connect the Dome Sx
display only to a center-tapped, 240V, single-phase supply (for
Canada and the United States only).

6 | Dome Sx Display
Video Cable Installation on the Dome S10 Display
Note the location of the primary input on the Dome S10 display,
shown below, for proper video cable installation. Improper
connection may cause VGA boot messages not to appear on
the display screen.
Primary video signal input on the Dome S10 connector plate

Technical Information | 7
Technical Information
The design of the Dome® Sx digital display takes into account every
known measure to ensure your personal safety. Improper use of
the display can result in electric shock, fire, or damage to the display.
Read all instructions before setting up the display.
Classification
Shock Protection: Class I.
Degree of Protection Against Electric Shock: No applied part.
Degree of Protection Against Harmful Ingress of Water:
Ordinary equipment (IPX0).
Degree of Safety in the Presence of Flammable Anaesthetic
Mixture with Air or with Oxygen or Nitrous Oxide:
Not suitable for use in the presence of a flammable
anaesthetic mixture with air or with oxygen or nitrous oxide.
Mode of Operation: Continuous.
No applied part
Important recycle instruction
HAZARDOUS SUBSTANCE. Lamp(s) inside this product contain
mercury. This product may contain other electronic waste
that can be hazardous if not disposed of properly. Recycle
or dispose in accordance with local, state, or federal laws.
For more information, contact the Telecommunications
Industry Association at WWW.ECYCLINGCENTRAL.COM. For lamp-
specific disposal information, check WWW.LAMPRECYCLE.ORG.
DISPOSAL. Do not use household or municipal waste
collection services for disposal of electrical and electronic
equipment. EU countries require the use of separate
recycling collection services.
ENVIRONMENT-FRIENDLY USE PERIOD. Hazardous
substances are present. The number encircled by the
recycling symbol indicates the safe-use period (in years).
China requires the use of recycling services at the end of
product life.

8 | Dome Sx Display
Symbol explanations
Intended use
The Dome S series offers AMLCD units designed for viewing medical
X-ray images. A Dome Sx display should not be used near patients
and should be kept outside of 1.83 m perimeter and 2.29 m vertical.
Dome S3 and Dome S3c are intended for use in displaying and
viewing medical images for review and analysis by trained medical
practitioners.
Dome S10 is intended for use in displaying and viewing medical
images for review and analysis by trained medical practitioners, or
for use in displaying and viewing radiographs of the breast for review
and analysis by trained medical practitioners.
IMPORTANT: Only the Dome S10 display can be used for review and
analysis in mammography. Do not use the Dome S3 or Dome S3c
display in mammography review and analysis.
Federal law restricts this device to sale by or on the order of
a medical practitioner.
CAUTION. Read the accompanying text carefully, for
proper operation and maintenance of the display
system.
DANGEROUS VOLTAGE. Important precautions about
electric shock. Read the accompanying text carefully, to
prevent damage to display components and to guard
your safety.
DIRECT CURRENT.
BAROMETRIC PRESSURE. Transport and storage
12,000 meters (39,400 feet), maximum in unpressurized
container.
RELATIVE HUMIDITY. Transport and storage 5% to 90%
(noncondensing).
TEMPERATURE. Transport and storage -20° to 60° C.

Technical Information | 9
Safety precautions
External equipment intended for connection to signal input, signal
output, or other connectors, must comply with the relevant IEC standard
(EN/IEC 60601-1 series for medical electrical equipment). In addition, all
such combinations (systems) must comply with the standard IEC 60601-1-1,
Safety requirements for medical electrical systems.
Equipment not complying to IEC 60601 must be kept outside the patient
environment, as defined in the standard as at least 1.5 meters from the
patient or the patient support.
Any person who connects external equipment to signal input, signal output,
or other connectors has formed a system and is therefore responsible for the
system to comply with the requirements of IEC 60601-1-1. If in doubt, speak
with a qualified technician.
GROUNDING RELIABILITY CAN ONLY BE ACHIEVED WHEN EQUIPMENT IS
CONNECTED TO AN EQUIVALENT RECEPTABLE MARKED “HOSPITAL ONLY” OR
“HOSPITAL GRADE.”
Safety tips
• Never open the display case, even when the power is off. Dangerous
voltage inside may cause electric shock or death.
• To avoid damage to the display, use the grounded power supply and
video cable supplied by NDSsi, or use certified replacements.
• Be sure the display is electrically grounded. You must connect the third
grounding pin on the US power cord to a grounded outlet. The European
power cord does not have a third grounding pin, but it must be plugged
into a grounded outlet.
• If you cannot insert the plug into the outlet you plan to use, have a
licensed electrician replace the outlet with a properly grounded outlet.
If the power cord connects directly into the computer, make sure the
computer is grounded.
• Keep the display dry if it is part of a surgical system. The display lacks
protection against liquids or spills.
• In locations where 240V outlets are used, connect the Dome Sx
display only to a center-tapped, 240V, single-phase supply (for
Canada and the United States).

10 | Dome Sx Display
Unpacking and handling tips
The Dome Sx display is a precision instrument that requires proper care to
maintain product operation and adherence to specification. Unpack the
display and components carefully, then set up and handle the unit properly
to avoid damage to the LCD panel.
• Use both hands to grasp the display case when lifting it from the shipping
carton, but avoid touching the screen.
• Do not apply pressure to the screen or touch the screen with bare fingers
or objects. Pressure can affect image quality. Cosmetics and oils on the skin
are both detrimental to the screen and difficult to remove.
• Allow the display to warm up to room temperature before turning it on.
Avoid sudden temperature changes in the environment, as this may cause
condensation, which damages the display.
• Secure the display properly onto a standard VESA 100-mm mounting unit if
you elect not to use the desk stand.
• Do not set up the display near strong light or heat sources.
• Do not block the vents on the back of the display or install the display in
a built-in enclosure. Blocked vents cause excessive heat to build up inside
the display, increasing risk of fire.
• When installing components, turn off your computer, but leave it plugged
into a grounded outlet.
• Do not remove the back cover or disassemble the display. There are
no user-serviceable parts inside.
Preventing fire and injury
• Replace the power supply or cables if damaged.
• Use only the power source indicated in this guide or listed on the display.
• Do not plug the power supply into an overloaded AC outlet or extension
cord. Overloaded AC outlets and cords can result in electric shock or fire.
• Do not drop or push objects into the display case. Internal components
contain high voltage.
• Unplug the power cord from the wall outlet during thunderstorms.
• Do not place magnetic devices, such as motors, near the display.

Technical Information | 11
Cleaning the display
Observe the following guidelines to maintain the display and the LCD screen.
• Use a clean, lint-free, absorbent cotton cloth to clear off any residual glue
from removal of the protective film or to remove surface dust. Apply light
pressure to remove the dust.
• Dampen a clean cloth with a small amount of isopropyl alcohol to
remove glue or dust if the screen is still not clean. Do not saturate the
cloth; otherwise, alcohol may seep into the display case and collect in the
enclosure. Use a clean, dry cloth to completely remove the alcohol residue.
• Do not use chemically treated dust cloths, acetone, toluene, or harsh
solvents on the display case or the screen. They can damage the polarizer
and the display case.
• Do not expose the display to water or excessive moisture. Do not allow
water or other stains to stand on the unit. Wipe liquids off immediately to
prevent damage to the display case and the screen.
Shipping/storing the display
Keep the display in its shipping container until installation. Return the display
to its original container whenever you need to store the unit, move it to
another location, or return it for repair. The packaging supplied by the
manufacturer protects the display while it is in transit. See environment
specifications for more information.
Before returning the display to the container, do the following:
1 Swivel the display panel to landscape mode.
2 Push the panel down to the lowest position.
3 Use the stand lock to anchor the panel.
Disposal information
Follow your local governing ordinance and recycling policy for
proper disposal or recycling of display components.
WARNING
DISCONNECT SUPPLY BEFORE SERVICING
AVERTISSEMENT
COUPER L’ALIMENTATION AVANT L’ENTRETIEN ET LE DEPANNAGE

12 | Dome Sx Display
Dome S3 Specification
In locations where 240V outlets are used, connect the Dome S3 display to a center-tapped,
240V, single-phase supply only (for Canada and the United States).
Category Characteristic Item Specification
Screen Type AMLCD (active-matrix liquid crystal display)
Screen size diagonal 540 mm (21.3 in.)
Resolution 1536 x 2048 pixels (portrait)
2048 x 1536 pixels (landscape)
Pixel pitch 0.2115 mm, 120 dpi
Pixel arrangement LCR vertical stripe
Active area (H x V) 433.2 x 324.9 mm (17.05 x 12.79 in.)
Grayscale supported 1024 shades of gray (programmable gamma from
palette of up to 3061 shades of gray)
Refresh rate 60 Hz
Contrast ratio 900:1 typical; 650:1 minimum
Brightness 1450 cd/m2typical; 1150 cd/m2minimum
Pixel rise/fall time 27 ms typical
Viewing angle (CR 10: 1) 170° (± 85°) horizontal/vertical
Interface Digital Video In DVI Rev. 1.0 digital dual-channel connector
DisplayPort Revision 1.1a connector
Display control (brightness/contrast) DDC2B+
Display identification EDID read using DDC2B+
USB hub (on stand) N/A
USB uplink (on display) Universal Serial Bus Rev. 2.0: 1 uplink B port
Display status Dual-stack tricolor LEDs on back of unit
Input formats Landscape orientation 2048 x 1536 (10-bit per pixel)
Portrait orientation 1536 x 2048 (10-bit per pixel)
VGA/XGA 640 x 480 to 1280 x 768 pixels (displayed in
portrait orientation)
Physical Display size (without stand) 475 mm x 363 mm x 99 mm (18.6 in. x 14.3 in. x 3.9 in.)
Display weight (without stand) 6.6 kg (14.6 lb.) typical
Display weight (with stand) 9.5 kg (20.9 lb.) typical
Mounting options Desktop stand (standard);
100-mm VESA compliant mounting
Power Adapter BridgePower BPM130S12F02 (with power switch)
(CAUTION: Use only the adapter supplied with unit.)

Technical Information | 13
Power Supply
CAUTION: Use only the power adapter supplied with the Dome S3 display unit;
the BridgePower BPM130S12F02 (130W) model.
Reliability
Environment
Category Characteristic Item Specification
Power input
requirements
Voltage selection Universal auto switching with medical
approvals and PFC
Voltage 100–240V AC
Current 3.0 A
Frequency 50–60 Hz
Power consumption Wattage 90 W typical
Power output
requirements
Voltage 12 V DC ±5%
Current 10.8 A (130 W)
Physical Size 228.6 mm x 76.2 mm x 50.8 mm
(9 in. x 3 in. x 2 in.)
Weight 1.3 kg (2.75 lb.)
Characteristic item Specification
Display MTBF > 50,000 hours
Backlight MTBF 50,000 hours to 50% brightness with backlight on continuously
Characteristic item Specification
EMI shielding No emission of low-level radiation
Temperature operating 0° C ~ 40° C
storage -20° C ~ 60° C
Humidity operating 20% ~ 90% Relative Humidity
(noncondensing)
storage 5% ~ 90% Relative Humidity
(noncondensing)

14 | Dome Sx Display
Dome S3c Specification
In locations where 240V outlets are used, connect the Dome S3c display to a center-
tapped, 240V, single-phase supply only (for Canada and the United States).
Category Characteristic Item Specification
Screen Type AMLCD (active-matrix liquid crystal display)
Screen size diagonal 540 mm (21.3 in.)
Resolution 1536 x 2048 pixels (portrait)
2048 x 1536 pixels (landscape)
Pixel pitch 0.2115 mm, 120 dpi
Pixel arrangement R,G,B vertical stripe
Active area (H x V) 433.2 x 324.9 mm (17.05 x 12.79 in.)
Color supported 16.7 million colors; 256 shades of gray
(programmable gamma from palette of up to
2041 shades)
Refresh rate 60 Hz
Contrast ratio 750:1 typical; 600:1 minimum
Brightness 700 cd/m2typical; 550 cd/m2minimum (when new)
Pixel rise/fall time 24 ms typical (14 ms Tr/10 ms Tf)
Viewing angle (CR 10: 1) 170° (± 85°) horizontal/vertical
Interface Digital Video In DVI Rev. 1.0 digital dual-channel connector
DisplayPort Revision 1.1a connector
Display control (brightness/contrast) DDC2B+
Display identification EDID read using DDC2B+
USB hub (on stand) N/A
USB uplink (on display) Universal Serial Bus Rev. 2.0: 1 uplink B port
Display status Dual-stack tricolor LEDs on back of unit
Input formats Landscape orientation 2048 x 1536 (24-bit per pixel; 30-bit per pixel
via DisplayPort)
Portrait orientation 1536 x 2048 (24-bit per pixel; 30-bit per pixel
via DisplayPort)
VGA/XGA 640 x 480 to 1280 x 768 pixels (displayed in
portrait orientation)
Physical Display size (without stand) 472 mm x 363 mm x 102 mm
(18.6 in. x 14.3 in. x 3.9 in.)
Display weight (without stand) 6.4 kg (14.0 lb.) typical
Display weight (with stand) 9.3 kg (20.5 lb.) typical
Mounting options Desktop stand (standard);
100-mm VESA compliant mounting
Power Adapter BridgePower BPM150S24F05 (with power switch)
(CAUTION: Use only the adapter supplied with unit.)

Technical Information | 15
Power Supply
CAUTION: Use only the power adapter supplied with the Dome S3c display unit;
the BridgePower BPM150S24F05 (150W) model.
Reliability
Environment
Category Characteristic Item Specification
Power input
requirements
Voltage selection Universal auto switching with medical
approvals and PFC
Voltage 100–240V AC
Current 2.5 A
Frequency 50–60 Hz
Power consumption Wattage 108 W typical
Power output
requirements
Voltage 24 V DC ±5%
Current 6.25 A (150 W)
Physical Size 223.5 mm x 63.5 mm x 38.1 mm
(8.8 in. x 2.5 in. x 1.5 in.)
Weight 0.8 kg (1.8 lb.)
Characteristic item Specification
Display MTBF > 50,000 hours
Backlight MTBF 50,000 hours to 50% brightness with backlight on continuously
Characteristic item Specification
EMI shielding No emission of low-level radiation
Temperature operating 0° C ~ 35° C (10° C ~ 35° C within specification)
storage -20° C ~ 60° C
Humidity operating 20% ~ 90% Relative Humidity
(noncondensing)
storage 5% ~ 90% Relative Humidity
(noncondensing)

16 | Dome Sx Display
Dome S10 Specification
In locations where 240V outlets are used, connect the Dome S10 display to a center-
tapped, 240V, single-phase supply only (for Canada and the United States).
Category Characteristic Item Specification
Screen Screen size diagonal 762 mm (30.0 in.)
Resolution 4096 x 2560 pixels (landscape)
Pixel pitch 0.158 mm, 161 dpi
Pixel arrangement Single pixel, IPS structure
Active area (H x V) 645.1 x 403.2 mm (25.40 x 15.87 in.)
Grayscale supported 1024 shades of gray (programmable gamma from
palette of up to 4096 shades of gray)
Refresh rate 50 Hz
Contrast ratio 850:1 typical; 700:1 minimum
Brightness 1250 cd/m2typical; 1000 cd/m2minimum (when new)
Pixel rise/fall time 35 ms typical (20 ms Tr/15 ms Tf)
Viewing angle 170° (± 85°) horizontal/vertical
Interface Digital Video In 2x DVI Rev. 1.0 digital dual-channel connector
Display control (brightness/contrast) DDC2B+
Display identification EDID read using DDC2B+
USB hub (on stand) N/A
USB uplink (on display) Universal Serial Bus Rev. 2.0: 1 uplink mini-B USB port
Display status Dual-stack tricolor LEDs on back of unit
MQSA Two color bottom facing LEDs on front of unit with
push-button activation
Input formats Landscape orientation 4096 x 2560 (10-bit per pixel)
Portrait orientation 2x 2048 x 2560 (10-bit per pixel)
VGA/XGA 640 x 480 to 1280 x 1024
Screen type AMLCD (active-matrix liquid crystal display)
Physical Display size (without stand) 699 mm x 473 mm x 79 mm
(27.5 in. x 18.6 in. x 3.1 in.)
Display weight (typical) 7.7 kg (17 lb.) without stand; 10.9 kg (24 lb.) with stand
Mounting options Desktop stand (standard);
100-mm VESA mounting (optional)
Power Adapter BridgePower BPM150S24F05 (with power switch)
(CAUTION: Use only the adapter supplied with unit.)

Technical Information | 17
Power Supply
CAUTION: Use only the power adapter supplied with the Dome S10 display unit;
BridgePower BPM150S24F05 (150W).
Reliability
Environment
Category Characteristic Item Specification
Power input
requirements
Voltage selection Universal auto switching with medical
approvals and PFC
Voltage 100–240V AC
Current 2.5 A
Frequency 50–60 Hz
Power consumption Wattage 138 W maximum
Power output
requirements
Voltage 24 V DC ±5%
Current 6.25 A (150 W)
Physical Size 223.5 mm x 63.5 mm x 38.1 mm
(8.8 in. x 2.5 in. x 1.5 in.)
Weight 0.8 kg (1.8 lb.)
Characteristic item Specification
Display MTBF >50,000 hours
Backlight MTBF 50,000 hours to 50% brightness with backlight on continuously
Characteristic item Specification
EMI shielding No emission of low-level radiation
Temperature operating 5° C ~ 35° C (within specification)
storage -20° C ~ 60° C
Humidity operating 20% ~ 90% Relative Humidity (noncondensing)
storage 5% ~ 90% Relative Humidity (noncondensing)

18 | Dome Sx Display
Video Modes
Resolutions expressed in pixels (W x H).
Connector Plate
All Dome Sx displays have a DVI connector. The Dome S3 and Dome S3c displays also
have a DisplayPort connector.
Display Resolution Orientation Palette Bits per pixel
Dome S3 1536 x 2048
2048 x 1536
Portrait
Landscape
32-bit 10
Dome S3c 1536 x 2048
2048 x 1536
Portrait
Landscape
True Color 24; 30 (DisplayPort only)
Dome S10 2x 2048 x 2560
(non-span mode)
Portrait 32-bit 10
4096 x 2560
(horizontal span mode)
Landscape 32-bit 8 (Windows 7);
10 (Windows XP)
Display Video Port DIN Connector Power Input Adapter
Dome S3 DVI and
DisplayPort
8-pin 12V ±5% (130 W) BPC BPM130S12F02
(with power switch)
Dome S3c DVI and
DisplayPort
6-pin 24V ±5% (150 W) BPC BPM150S24F05
(with power switch)
Dome S10 DVI 6-pin 24V ±5% (150 W) BPC BPM150S24F05
(with power switch)
8-pin connector on Dome S3 display
6-pin connector on Dome S3c and Dome S10 displays
VCC 7
VCC 8
1 GND
VCC 5 3 GND
2 GND
VCC 6
4 GND
1 GND
VCC 6
VCC 4 3 GND
2 GND
VCC 5
Table of contents