Dong-Do IM-2DT User manual

High Precision 2-Axis Digital Electronic Inclinometer
IM-2DT
User’s Guide
The contents of this manual could be different according to the software version
and it can be changed without notice.
Please use this good after reading the manual thoroughly.

Table of Contents
Table of Contents & Introduction……………………………………………………………………………2
Product features ….…………………………………………………………………………3
Functions .……………………………………………………………………………4
How to use the ‘Flat’ mode .……………………………………………………………………………7
RS232C Serial communication …..………………………………………………………………………..8
Specifications …………………………………………………………………………….9
Introduction
Thanks for buying our product.
IM-2DT is a high precision dual axis inclinometer with a color TFT and touch panel.
It is possible to do high speed horizontal plane setting for high precision machines
or home appliance as like laundry machine.
Specialty of IM-2DT
1. Easy to set the level of the space with 2 axis angles display at once.
2. Level up the visual-effects by the color LCD!
3. Small & light so that possible to use to a sensor unit.
4. Possible to insert to high precision systems.
5. Included the RS232C output.
6. Built-in Li-ion rechargeable battery. (Rechargeable to USB port on PC)

Product features
Charge &
RS232C port Flash light
•Master button
- Master button has 4 functions below,
1. Power On : Pushing the key once if power is off then the power is on with a sound.
2. Power Off : Pushing the key for around 2 sec when the power is on. Then the power is off.
3. Flash On/Off : Pushing the key for under 1 sec after power is on. Then the flash is on / off.
The touch pad is not worked when the flash is on.
4. Touch pad Calibration : Pushing the key for over 5 sec. Then it is in the calibration mode of touch pad.
- This function is used when the touch pad doesn’t work well.
- The power should be on to enter this calibration mode.
Color TFT LCD
Master button
Touch Pad
⑤X/Y angle [ ˚ ]
•Touch Pad
- There’re 3 sections on the touch pad that have their own function. The below functions are exceeded
if each sections are touched.
1. Main menu entrance: To enter the main menu, touch the ‘MENU’ area.
2. Absolute / Relative value change area : To change the X / Y to absolute or relative value. (ABS ↔ REL)
- Absolute value : The displayed values of X / Y are from the absolute coordinate system.
The absolute coordinate system is set from the factory or user’s updating at the calibration menu.
- Relative value : To make current X / Y values to zero.
3. Tilt direction display area : To change the tilted direction display method. (Line ↔ bubble)
③Absolute / Relative
value change area.
①Tilted direction
display area.
④Main menu
entrance.
②Battery

Functions
1. Run
- To exit the main menu and display the measuring screen.
•Main Menu
-The main menu is composed as like the picture 1.
-Each functions can be chosen by touching the letters.
1. Run : To exit the main menu and display the measuring screen.
2. Mode : To change the mode of display.
3. Spec : To setup the specifications for the FLAT mode.
4. Calibration : To calibrate the absolute zero.
5. Average : To change the number of inputting row data to average them.
6. Display : To change display options as like brightness, power on time, etc.
7. Serial : To change the RS232C serial output method.
8. Save : To save whatever user has changed, it should be done.
9. About : To see the information of the manufacturer.
2. Mode
- To change the mode of display.
< Pole mode > < Flat mode >
* The composition of the screen for Flat mode (to adjusting 4 legs machines)
Absolute value /
Relative value
To change ABS & REL,
touch this area.
Battery remains
X/Y angle [ ˚ ] /
To enter the main menu, touch this area.
The adjusting points display area.
-The heights of the each points are already calculated
depends on the tilted angles. So users can adjust
the horizontal plane faster and easier.
The direction of tilted space
The height to adjust
The amount to turn
the adjusting screw legs
Picture 1 –main menu

Product features and function
3. Spec
- To setup the spec. for the FLAT mode.
1. Go Back : To exit the ‘Spec’ menu.
2. Tolerance : To setup the tolerance of the tilted direction display line.
3. Model : 10 memory spaces are given to save the users’ specification
setting. And user could recall them later.
4. X : The width of the setting points.
5. Y : The length of the setting points.
6. Pitch : The pitch of the screwed legs at the home appliances or other
machines.
7. Angle : It is set by 360 deg. normally.
4. Calibration
- To calibrate the absolute zero. Please follow the steps carefully.
If not, it can not be guaranteed the angle data.
Fig.1
Fig.2
Step 1 [XY Calibration]
Put the inclinometer on the surface as like Fig.1 and choose
the ‘XY 1st’. Then you might see ‘XY 1st Please Touch Screen’.
If the inclinometer is settled well on the surface, touch the screen
and wait until the inclinometer gathers the data and averages them.
Put the inclinometer as like Fig.2 and choose the ‘XY Rev’.
And touch the screen if the inclinometer is settled.
Step 2 [X Calibration]
Put the inclinometer on the surface as like Fig.3 and choose
the ‘X 1st’. Then you might see ‘X 1st Please Touch Screen’.
If the inclinometer is settled well on the surface, touch the screen.
Put the inclinometer as like Fig.4 and choose the ‘X Rev’.
And touch the screen if the inclinometer is settled.
Fig.3
Fig.4
* [Y Calibration]
User doesn’t have to do the Y calibration because the Y calibration
is done automatically if the X calibration is done.
* [Default]
If the calibration is not done well, user can choose the ‘default’.
Then IM-2DT will recall the zero setting values at the factory.

Functions
5. Average
- To change the number of inputting row data to average them. It can be set from 1 to 30.
6. Display
- To change display options as like brightness, display off time, etc.
1. Go back : To exit the ‘Display’ menu.
2. Touch Calib. : To calibrate the touch pad.
It is the same with pushing the master button for over 5 sec when power is on.
3. Brightness : To change the brightness of the screen.
4. Display Off : To change the display on time. The screen will be off after this time.
5. Power Off : To change the power on time. The power will be off after this time.
6. Line width: To change the width of the tiled direction indicating line
at the POLE mode
[ Touch pad calibration method ]
- Just touch the blue crosses at the five points in order.
7. Serial
- To change the RS232C serial output method.
1. Poll mode : There’re 4 RS232C output method as like below.
- Command : X / Y data is outputted once whenever it gets ‘CALL+ID’ command.
( Default ID is 00 so that the command should be ‘CALL00’ )
- Polling : X / Y data is outputted continuously.
- Polling 1 sec. : X / Y data is outputted every 1 sec.
- Polling 10 sec. : X / Y data is outputted every 10 sec.
2. ID : IM-2DT can have the id from 0 to 99
so that user can get the tilted data from the various IM-2DTs.
8. Save**
- To save whatever user has changed, it should be done. If user doesn’t want to save the current
changes, just turn off the power by pushing the master button for around 2 sec.
9. About
- To see the information of the manufacturer.

How to use the FLAT mode
FLAT mode is used to adjust the 4 legs machines, as like laundry machine, etc., very easily.
There are shown the 3 points, that makes a plane, with the heights to raise up.
P1 :
It should be up 19.2mm
(1.9 turns up if there’s
a screwed leg)
P2 :
The highest point.
So, it doesn't have to be
raise up anymore.
P3 :
should be up 196.42mm
(19.6 turns up)
P4 :
Floated point
(It should chosen by user.)
* The floated point should be taught by user. It could be P1, P2, P3, or P4 depend on situation.
If user touches the area of the floated point on the screen, IM-2DT calculates and displays the heights of the
other 3 points. The floated point should be filled up at the last after user finishes to adjust the 3 points level.
** Before measuring!
To use this flat mode, user also has to set the below parameters.
1. Model : 10 memory spaces are given to
save the users’ specification setting. And
user could recall them later.
2. X : The width of the setting points.
3. Y : The length of the setting points.
4. Pitch : The pitch of the screwed legs at the
home appliances or other machines.
5. Angle : It is set by 360 deg. normally.
X
Y

RS232C serial communication
Communication protocol(ASCII)
* ISC-T :
It is necessary to do RS232C serial communication with IM-2DT.

Specifications
System
Model IM-2DT
Measuring range ±30˚
Resolution 0.01˚
Accuracy ±0.03˚
Non linearity < 1% FS
Response time < 1.0 sec
Input / Output port
Charging / RS232C Mini type 5 pin USB connector
Power
& Other features
Power Li-ion Battery 3.7V (Rechargeable)
Operation time Around 7 hours with fully charged battery. *
Charging 5 pin mini type USB cable to PC or USB connector type adapters.
LCD 320 x 240 pixel, Color TFT LCD
Size(W/L./H) 115 x 66 x 22mm
Weight 180g
Operation environment
Temp. : 0˚C ~ +45˚C / Humidity : below 80%
* Tip to save the battery power:
1. Reduce the brightness of the LCD.
2. Reduce the display on time if it’s not uncomfortable.
3. Reduce the power on time if it’s not uncomfortable.

Gyeonggi-do Yongin-si Cheoin-gu Baegam-myeon Bakgok-ri 706-2
Tel: +82-31-339-6704 / Fax: +82-31-339-4577
Table of contents
Popular Measuring Instrument manuals by other brands

BASETech
BASETech BTTH-1014 operating instructions

Dostmann Electronic
Dostmann Electronic 5020-0343 Instructions for use

FRONIUS
FRONIUS Smart Meter IP quick start guide

Digi-Sense
Digi-Sense 20250-19 user manual

Ink Bird
Ink Bird MH-068 manual

thermastor
thermastor Santa-Fe Crawlspace Alert installation manual