Dormakaba SafeRoute STL-G Series User manual

EN
STL-G/STL-G NT
Mounting instructions WN 059727 45532/15191
2020-07
1 About this document
1.1 Contents and purpose
This document describes the mounting of the
STL-G door terminal with a profile cylinder and the
connection to a SafeRoute® system.
1.2 Target group
This document is intended for assembling technicians
and specialists authorized to carry out installation by
dormakaba.
1.3 Other applicable documents:
The following documents belong to the unit’s
complete documentation and must be observed:
• The optional accessory components’ assembly
instructions and documents
• The SafeRoute® system manual
• The respective door unit’s inspection log
• The approved components’ declaration of
conformity
1.4 Documents storage
This document must be handed over to the facility
operator after mounting and commissioning.
1.5 Symbols used
1.5.1 Hazard categories
WARNING
This signal word indicates a possible
hazardous situation which may result in
death or serious injury if not averted.
1.5.2 More symbols
1. 2. Sequence of action steps
6Reference to a chapter
Components may be damaged by
electrostatic discharge. Ground
your own body before touching a
component!
2 Safety
2.1 Intended use
The STL-G is a door terminal for operating and/or
controlling dormakaba's SafeRoute® electrical locking
system.
2.2 Personnel qualification
Mounting may only be carried out by persons
authorized by dormakaba.
Contents
1 About this document 1
2 Safety 1
3 Product description 2
4 Mounting 4
5 Disassembly, recycling and disposal 12

2STL-G/STL-G NT 2020-07
WN 059727-45532
dormakaba Mounting instructions Product description
3 Product description
The STL-G door terminal is a component in a
SafeRoute® system. The STL-G contains the DCW®
component emergency button SCU-TL and a key
switch ST. The installation and connection of other
components is possible. Only components and parts
approved by dormakaba for a SafeRoute® system
may be used (see approved components’ declaration
of conformity).
With a license card inserted, the SCU-TL emergency
button is a SafeRoute® Control Unit in a SafeRoute®
escape route security system.
Fig. 1
4
31
2
5
6
STL-G door terminal with profile cylinder
Fig. 2
2
STL-G door terminal with round cylinder
1Emergency button SCU-TL
2Key switch ST for receiving a 30/10 lock cylinder
(version as profile or round cylinder; profile or
round cylinder is not part of the delivery)
3Slot for optional SLI license card and SLI-A
application card
4Installation space for optional distributor STL-G V
5Installation space for optional flush-mounted
components UP with installation depth up to 62
mm (up to 35 mm installation depth when using
the SLON-UP module)
6Installation space for optional SLON-UP module
3.1 Variants
The STL-G door terminal is available with profile or
round cylinder in versions with power supply (STL-G
NT) and without power supply (STL-G).
3.2 Technical data
Supply voltage version
without power supply
Power consumption
24VDC +/- 15% or
better
Quiescent current:65
mA
in case of alarm:100
mA
Supply voltage version with
power supply
Power consumption
Output voltage
Output current
230 V AC +/- 15%
max. 0.7 A
24VDC +/- 2%
max. 1 A
Ambient temperature: -10°C to +55°C
Rel. humidity: up to 93%
(non condensing)
Protection class: IP30

3STL-G/STL-G NT 2020-07WN 059727-45532
dormakaba Mounting instructions Product description
3.3 Parts included
3.4
WN059285 45532, 2018- 02
18 k
Dimensions
3.5
88
63
245
181
30
35
5
95 86
54
15
252,5
7594,5
A
Mounting position
The STL-G door terminal must be installed in the immediate vicinity of the door. The installation may be lower
than installation height A in areas where the users are predominantly small children.
WN059 45532,2018-02285
AAEltVTR = 850 – 1200 mm
A DIN EN 13637 = 800 – 1200 mm
0 – 600 mm
0 – 600 mm
RC
PC

63
86
300
A
95
63
86
300
A
95
4STL-G/STL-G NT 2020-07
WN 059727-45532
dormakaba Mounting instructions Mounting
1A 1B
2A
1.
2.
3.
1.
1.
1.
1.
230V
NYM 3 x 1.5 mm²
J-Y(St)Y 2x2x0.8
(DCW® bus) J-Y(St)Y 2x2x0.8
(DCW® bus)
STL-G
STL-G STL-G NT
4 Mounting
WARNING
Risk to life due to electric shock.
Works on electrical systems must only be
carried out by qualified electricians.
• Before starting work on electrical systems
and equipment, establish a voltage-
free state and maintain this state while
carrying out the work.
4.1 Mount the door terminal

L1
N
5STL-G/STL-G NT 2020-07WN 059727-45532
dormakaba Mounting instructions Mounting
230V
NYM 3 x 1.5 mm²
2B
4.
1.
2.
5.
5.
6.
7.
8.
10.
9.
min. 10mm
STL-G NT
24VDC (rt)
GND (ws)
3.
10.

6STL-G/STL-G NT 2020-07
WN 059727-45532
dormakaba Mounting instructions Mounting
3
4

90o
45o
30 10
4.2
7STL-G/STL-G NT 2020-07WN 059727-45532
dormakaba Mounting instructions Mounting
5
6
1.
1.
2.
2.
24VDC (rt)
GND (ws)

4.2
X5
X5
X2
2.
1.
8STL-G/STL-G NT 2020-07
WN 059727-45532
dormakaba Mounting instructions Mounting
7
8

CR 1220
+
9STL-G/STL-G NT 2020-07WN 059727-45532
dormakaba Mounting instructions Mounting
1.
9
10
SLI license card
(optional)
Battery (optional)

0
WN 059285 45532, 2018-02
S2S6 S5 S4
4.2
10 STL-G/STL-G NT 2020-07
WN 059727-45532
dormakaba Mounting instructions Mounting
11
13
12
14
1.
1.
2.

11STL-G/STL-G NT 2020-07WN 059727-45532
dormakaba Mounting instructions Mounting
4.2 Assignment of terminals and switch/button
STV1xx
STV5xx
TV-Z 510
STV2xx
SCU-TL
X2
X3
X4
1AB3
Out2
1G
In1
3
1
Out1
AS
GND
Rx
Tx
RS232
18 k
J-Y(St)Y 2x2x0,8 STVxxx
1
A
B
3
DCW®
ST
X5
X2
X3
X4
1AB3
Out2
1G
In1
3
1
Out1
AS
GND
Rx
Tx
DCW®
X1 X5
S2
S4
S6
S
B
ON
1 2
LED SLI
S5 A
B
X1
X1 Connection to key switch ST
X2
A
1
3
B
1G
Out2
24VDC
DCW® bus
DCW® bus
GND
24VDC
Output 2
Stabilized power supply
Switched voltage (test “Power Reserve Modul M-SVP/SVP”)
Common alarm (default value)
X3
3
In1
1
Out1
AS
5–28VDC
GND
18k
Output 1
Static control (default value)
Output
Locked (default value) Alarm system, e.g. fire alarm system or smoke
detector (see default value)
X4
Rx
Tx
3GND
TxD
RxD
RS232 interface
X5 Connection to distributor STL-G-S
LED SLI LED display license card/application card
S2
BS
Service switch for suppression of tamper alarm:
B = Operation (housing tampering contact activated)
S = Service (housing tampering contact shut off, internal and external
tampering messages are suppressed)
S4 Service button
S5
AB
Alarm system switch
A = alarm system activated
B = alarm system not connected (default value)
S6 DIP switch for setting the number of doors (operation of SCU-TL with
license card and multi-door application) or to set up the DCW® address
of other connected emergency buttons (operation of SCU-TL without
license card):
DCW® address DIP switch
1
2
3
4
0
1
0
1
0
0
1
1
Number of doors DIP switch
1
2
3
4
0
1
0
1
0
0
1
1

dormakaba Deutschland GmbH
DORMA Platz 1 58256 Ennepetal Germany T: +49 2333 793-0 F: +49 2333 793-4950 www.dormakaba.com
4.3 Complete mounting
1. Document the mounting and commissioning in
the inspection log.
2. Hand over this document to the facility operator.
5 Disassembly, recycling and
disposal
Disassembly is carried out in the reverse order of
mounting and must be carried out by qualified
personnel.
The product must be disposed of in an
environmentally friendly manner.
Electrotechnical parts and batteries must not
be disposed of as domestic waste. Dispose of
electrotechnical parts and batteries in the designated
acceptance and collection points. Refer to the
statutory regulations for your country.
Translation of the original manual, subject to change without notice
STV1xx
STV5xx
TV-Z 510
STV2xx
SCU-TL
X2
X3
X4
1AB3
Out2
1G
In1
3
1
Out1
AS
GND
Rx
Tx
RS232
18 k
J-Y(St)Y 2x2x0,8 STVxxx
1
A
B
3
DCW®
ST
X5
X2
X3
X4
1AB3
Out2
1G
In1
3
1
Out1
AS
GND
Rx
Tx
DCW®
X1 X5
S2
S4
S6
S
B
ON
1 2
LED SLI
S5 A
B
X1
STL-G-S *
Example of wiring diagrams
STL-G NT + STVxxx
Optional
alarm system
Power
supply unit
NT
*for louder acoustic signals
and the housing’s tamper contact
This manual suits for next models
1
Table of contents
Other Dormakaba Intercom System manuals