7
ENGLISH
L2000631 Installation guide for DucoBox Focus (Revision J | 17.07.2019)
05.B Pairing the control valves
The control valves are paired automatically to the DucoBox whenever ‘installer mode’ is activated (see “Pairing components” chap-
ter).
05.C Removing / replacing a control valve
Taking control valve out temporarily
Follow these steps to take a control valve out of the unit
temporarily, e.g. to clean it during maintenance. Take care to
ensure that it is inserted back in the same location. Use the
letter labels on the DucoBox and the relevant valve for this. The
DucoBox will retain all its settings when the control valve is
reconnected.
Temporarily removing control valve
1Short-press the valve button in order to drive it
shut for 15 minutes. The LED will go out.
2Disconnect the wiring.
3Slide the valve out of the DucoBox.
Permanently removing or replacing control valve
To remove a control valve permanently from the system or to replace it (e.g. in the event of a fault) it is important that it should be
paired correctly. The DucoBox will not be able to be calibrated correctly if this is not done.
Permanently removing control valve
1Short-press the valve button in order to drive it shut.
2
Activate ‘Installer mode’ by pressing ‘INST’ on the
DucoBox. The LEDs on the DucoBox and control
valves will flash green rapidly.
3
Long-press the button once on the control valve to be
removed in order to remove it from the network. NB:
any underlying components will also be removed
from the network.
4Disconnect the wiring from the control valve to be
removed and slide it out of the DucoBox.
5Deactivate ‘Installer mode’ by pressing ‘INST’ on the
DucoBox. All LEDs will stop flashing.
Replacing a control valve
1Short-press the valve button in order to drive it shut.
2
Activate ‘Installer mode’ by pressing ‘INST’ on the
DucoBox. The LEDs on the DucoBox and control
valves will flash green rapidly.
3Short-press the button twice on the control valve to
be replaced in order to remove it from the network.
4Disconnect the wiring from the control valve to be
replaced and slide it out of the DucoBox.
5Slide the new control valve into the DucoBox and
connect it.
6
Short-press the button on the new control valve
once. The latter will take on all settings / connecti-
ons in the network.
7Deactivate ‘Installer mode’ by pressing ‘INST’ on the
DucoBox. All LEDs will stop flashing.
05.D LED indications
The LED on the control valves will be white or off in normal
operation, depending on the control valve position. The bright-
ness of the LED indicates the flow rate through the valve.
Please refer to “07.B LED indications on page 9 for the
meaning of the remaining LED colours.
Valve open
= max air flow
LED
Valve shut
= lowest air flow
LED