E. LOCATION OF THE BROILER
Properplacementofthebroilerwillgiveyouthebest
resultslong-termuserconvenience.Weurgeyouto
giveadequatethoughtintheplacementofyourbroiler
priortoitsarrival.
• Thebroilershouldbeplacedinanareathatisfree
fromdraftsandaccessibleforproperoperationand
servicing.
• Theareaaroundthebroilermustbekeptclearof
combustiblematerialsasspecicbelow:
COMBUSTIBLE SURFACE SPACING
DischargeEnd(leftside) 305 mm
AccessPanelEnd(rightside) 76 mm
Rear 102 mm
Floor/Table 0 mm
F. GAS PIPING
The standard broiler consumes gas at a total of
100,000 BTU/hr, 29.4 KW.Theoverallpipingplan
of the kitchen must support the supply rating to
supportappliancetoachievetheperformancerating.
Generally, piping should be sized to provide a gas
supplysufcienttomeetthemaximumdemandofall
gasappliancesonalinewithoutunduelossofpressure
totheequipment.ThetotalBTUrequirementsofall
equipmentbeingservedandthepipinglengthfromthe
meteraremajorconsiderationsintheproperdesignof
thegassupplysystem.
NOTE: A xed restraint of the proper length
must be incorporated to secure the broiler to
a non-movable surface to eliminate strain on
the gas connector.
G. ELECTRICAL CONNECTIONS
Yourbroilermustbesuppliedfroma230Volt50Hz,
groundedcircuitwithasupplycordforeachcountry’s
requirements.Awiringdiagramisattachedtothebroiler
controlcompartmentandwiththismanual.
The Main Supply safety / earth ground wire must
be longer than main conductors at the unit's
interconnectionstopreventstressunderpull.
Ifthesupplycordisdamaged,itmustbereplacedby
themanufacture,it'sserviceagentorsimilarlyqualied
personsinordertoavoidahazard.
EXTERNAL EQUIPOTENTIAL
Terminal provides a connection for bonding to
equipmentenclosure.
: This appliance employs an
earthed, safety ground electrical supply system.
DO NOT cut or modify the earthing provisions of
this appliance.
H. VENTILATION
This appliance shall be installed with sufficient
ventilationtopreventtheoccurrenceofunacceptable
concentrationsofsubstancesharmfultohealthinthe
roominwhichtheapplianceisinstalled.
Venting to a Canopy Exhaust Hood
A mechanically driven exhaust hood must have a
minimumcapacityof1700m3/hr(1000cfm)witha
minimum100cmby130cm(39.4inby51.2in)opening
to adequately vent this appliance. The specied
capacityandopeningisrequiredinadedicatedhood
for this appliance or in addition to other appliance
ventedthroughacommoncanopyexhausthood.
Maintenance of Ventilation System
The ventilation system must be maintained and
annuallyinspectedbyQualiedPersonnelconcurrent
aspartoforinadditiontogovernmentalrequirements.
This inspection/maintenance should consist of, but
notbelimitedto:
• Inspectionforblockagesorbuildupwhichmight
interferewiththeventingofthebroiler.
• Repairofsuchblockages.
• Inspectionoftheventingcanopy,itsdrivemotors
andbells,etc.
: Do not place any objects such as
sheet pans, food containers or aluminum foil on
the top of the broiler. This will obstruct the venting
of cooking vapors and airow through the unit—
resulting in poor cooking performance.