manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Duratool
  6. •
  7. Thermometer
  8. •
  9. Duratool D03129 User manual

Duratool D03129 User manual

Other Duratool Thermometer manuals

Duratool D03308 User manual

Duratool

Duratool D03308 User manual

Duratool D03055 User manual

Duratool

Duratool D03055 User manual

Duratool PSG08700 User manual

Duratool

Duratool PSG08700 User manual

Popular Thermometer manuals by other brands

Delton 981A instruction manual

Delton

Delton 981A instruction manual

Baker MM2P instruction manual

Baker

Baker MM2P instruction manual

Tarmo 320281 manual

Tarmo

Tarmo 320281 manual

Citizen CTD 504 instruction manual

Citizen

Citizen CTD 504 instruction manual

TFA 14.1500 instruction manual

TFA

TFA 14.1500 instruction manual

Vive DMD1010 user manual

Vive

Vive DMD1010 user manual

Gotemp THB4002 user guide

Gotemp

Gotemp THB4002 user guide

GREISINGER G 1202 Quick reference guide

GREISINGER

GREISINGER G 1202 Quick reference guide

Amprobe TMD-53W user manual

Amprobe

Amprobe TMD-53W user manual

Trotec BP10 operating manual

Trotec

Trotec BP10 operating manual

Radiance instruments RT616 Series product manual

Radiance instruments

Radiance instruments RT616 Series product manual

Eurolec IR151 operating instructions

Eurolec

Eurolec IR151 operating instructions

Scaneo TS42B instruction manual

Scaneo

Scaneo TS42B instruction manual

Sper scientific 800043 instruction manual

Sper scientific

Sper scientific 800043 instruction manual

Motorola MBP69SN General questions

Motorola

Motorola MBP69SN General questions

The MeatStick The MeatStick quick start guide

The MeatStick

The MeatStick The MeatStick quick start guide

Hama TH35-A operating instructions

Hama

Hama TH35-A operating instructions

Veridian Healthcare 09-349 instruction manual

Veridian Healthcare

Veridian Healthcare 09-349 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

MODEL: D03129
Digital Thermometer
IMPORTANT SAFETY INFORMATION
Please read these instructions carefully before use and retain for future
reference.
• When using electrical appliances basic safety precautions should always be
followed.
• Before use, check that there is no damage to the instrument, there is no metal
exposed or sign of wear to the insulating layer of the probe.
• When the low battery indicator is displayed, replace the battery immediately to
avoid any potential measurement error.
• If the thermometer is not going to be used for a long period of time, remove the
batteries to avoid any potential product damage caused by battery leakage.
• The instrument is not suitable for fast measuring changes in ambient temperature.
• Do not allow the thermocouple probe to contact charged objects, otherwise it may
damage the instrument.
• Do not fold the thermocouple leads, as repeated bending over a period of time
may cause the wire to break.
OVERVIEW
1. Room temperature sensor
2. LCD
3. Data hold key
4. Slide switch
• OFF - Power off
• °C - Celsius display unit
• °F - Fahrenheit display unit
5. Range selection key: Range
switching 0.1 or 1 resolution
6. Thermocouple jack
7. K-type thermocouple probe
USAGE
• Insert the K-type thermocouple into the thermocouple jack.
• Move the slide switch to the “°C” or the “°F” position.
• Place the thermocouple probe in contact with the measured object.
• Read the results on the LCD.
• If the value displayed is less than 200, you can choose to display 0.1 range
resolution by pressing the “RANGE” button.
Note: When the thermocouple is not inserted into the thermocouple or the
thermocouple is open, the instrument will display the temperature of the environment.
GENERAL SPECIFICATIONS
Working environment conditions 0~40°C (<80%RH)
Storage environment conditions -10~60°C (<70%RH, without batteries)
Sampling rate About two times/second
Display 3½ bit LCD
Thermocouple open indication Displays the environment temperature
Low battery indication will be displayed on the LCD
Power requirement 2 x 1.5V AAA batteries
Dimensions 128 x 61 x 25mm
Thermocouple probe TP-01 type K
Range: -50°C~250°C (-58°F~482°F)
Accuracy: ± (0.5% + 1°C)
Length: 1m, with a miniature plug
ACCURACY SPECIFICATIONS
• The accuracy is applicable within one year of calibration.
• Reference conditions: the environmental temperature is 18°C to 28°C and relative
humidity is no more than 80%.
Celsius
Range Resolution Accuracy
-50°C ~ -20°C 0.1°C ± 6°C
-20°C ~ 0°C 0.1°C ± 3°C
0° ~ -200°C 0.1°C ± (1% reading + 2°C)
200°C ~ -500°C 1°C ± (1% reading + 2°C)
500°C ~ -750°C 1°C ± (1% reading + 3°C)
Fahrenheit
Range Resolution Accuracy
-58°F ~ -4°F 0.1°F ± 8°F
-4°F ~ 32°F 0.1°F ± 5°F
32°F ~ 200°F 0.1°F ± (1% reading + 4°F)
200°F ~ 932°F 1°F ± (1% reading + 4°F)
932°F ~ 1382°F 1°F ± (1% reading + 5°F)
CLEANING & MAINTENANCE
• Do not attempt to repair the instrument unless you are an experienced repair
person and have associated calibration, performance testing and maintenance
information.
• To clean the outer casing, use a clean, damp cloth and some mild detergent.
• Do not use any chemicals, abrasives or solvents that may damage the instrument.
REPLACING THE BATTERIES
• When the low battery indicator is displayed, replace the battery immediately to
avoid any potential measurement error.
• Turn off the power supply to the instrument.
• Loosen the screws of the battery cover and replace the battery cover.
• Remove the old batteries and replace with new ones.
• Replace the battery cover and tighten the screws so the cover is secure.
INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF
ELECTRICAL & ELECTRONIC EQUIPMENT.
This symbol indicate that separate collection of Waste Electrical and
Electronic Equipment (WEEE) or waste batteries is required. Do not dispose
of these items with general household waste. Separate for the treatment,
recovery and recycling of the materials used. Waste batteries can be
returned to any waste battery recycling point which are provided by most
battery retailers. Contact your local authority for details of the battery and
WEEE recycling schemes available in your area.
Made in China. PR2 9PP