Contents
Important information
1About this document .. . . . . . . . . . . . . 3
1.1 Warnings and symbols .. . . . . . . 3
1.2 Copyright information .. . . . . . . . 4
2 Safety .. . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1 Intended purpose .. . . . . . . . . . . 4
2.2 Intended use .. . . . . . . . . . . . . . . 4
2.3 Improper use .. . . . . . . . . . . . . . . 4
2.4 General safety information .. . . . . 5
2.5 Combining devices safely .. . . . . 5
2.6 Specialist personnel .. . . . . . . . . 5
2.7 Notification requirement of seri-
ous incidents .. . . . . . . . . . . . . . . 5
2.8 Electrical safety .. . . . . . . . . . . . . 5
2.9 Only use original parts .. . . . . . . . 5
2.10 Transport .. . . . . . . . . . . . . . . . . . 6
2.11 Disposal .. . . . . . . . . . . . . . . . . . 6
Product description
3Overview .. . . . . . . . . . . . . . . . . . . . . . . 7
3.1 Scope of delivery .. . . . . . . . . . . . 8
3.2 Optional items .. . . . . . . . . . . . . . 8
3.3 Consumables .. . . . . . . . . . . . . . 9
3.4 Wear parts and replacement
parts .. . . . . . . . . . . . . . . . . . . . . 9
4Technical data .. . . . . . . . . . . . . . . . . . . 10
4.1 VS 600 .. . . . . . . . . . . . . . . . . . . 10
4.2 VS 600 .. . . . . . . . . . . . . . . . . . . 12
4.3 VS 900 S .. . . . . . . . . . . . . . . . . 14
4.4 VS 1200 S .. . . . . . . . . . . . . . . . 16
4.5 Type plate .. . . . . . . . . . . . . . . . . 18
4.6 Evaluation of conformity .. . . . . . 18
5 Operation .. . . . . . . . . . . . . . . . . . . . . . 19
Assembly
6 Requirements .. . . . . . . . . . . . . . . . . . . 21
6.1 Installation/setup room .. . . . . . . 21
6.2 Setup options .. . . . . . . . . . . . . . 21
6.3 Pipe materials .. . . . . . . . . . . . . . 21
6.4 Hose materials .. . . . . . . . . . . . . 21
6.5 Information about electrical con-
nections .. . . . . . . . . . . . . . . . . . 21
6.6 Information about connecting
cables .. . . . . . . . . . . . . . . . . . . . 21
7 System components .. . . . . . . . . . . . . . 22
7.1 Control box .. . . . . . . . . . . . . . . . 22
7.2 Rinsing unit .. . . . . . . . . . . . . . . . 22
7.3 Flow accelerator .. . . . . . . . . . . . 22
7.4 Amalgam separator .. . . . . . . . . . 22
7.5 Surge tank .. . . . . . . . . . . . . . . . 22
7.6 Exhaust air filter .. . . . . . . . . . . . . 23
7.7 Noise reduction .. . . . . . . . . . . . . 23
8 Installation .. . . . . . . . . . . . . . . . . . . . . . 23
8.1 Installation and routeing of hoses
and pipes .. . . . . . . . . . . . . . . . . 23
9 Electrical connections .. . . . . . . . . . . . 26
10 Commissioning .. . . . . . . . . . . . . . . . . . 27
Usage
11 Disinfection and cleaning .. . . . . . . . . . 28
11.1 After every treatment .. . . . . . . . . 28
11.2 Daily after the end of treatment .. 28
11.3 Once or twice a week before the
midday break .. . . . . . . . . . . . . . 28
12 Cleaning the protective strainer .. . . . . 29
12.1 VS 600 .. . . . . . . . . . . . . . . . . . . 29
12.2 VS 900 S, VS 1200 S .. . . . . . . . 29
13 Maintenance .. . . . . . . . . . . . . . . . . . . . 30
Contents
9000-606-79/30 1912V003 1
EN

Important information
1 About this document
These installation and operating instructions rep-
resent part of the unit.
If the instructions and information in these
installation and operating instructions are
not followed, Dürr Dental will not be able
to offer any warranty or assume any liabil-
ity for the safe operation and the safe
functioning of the unit.
The German version of the installation and oper-
ating instructions is the original manual. All other
languages are translation of the original manual.
These installation and operating instructions
apply to:
VS 600
Order number: 7128-01; 7128-01/002;
7128-01/021; 7128-02; 7128-02/002;
7128-02/003; 7128100900
VS 900 S
Order number: 7134-01; 7134-01/002;
7134-01/021; 7134-02; 7134-02/002;
7134-02/021; 7134100900
VS 1200 S
Order number: 7138-02; 7138-02/002;
7138-02/021; 7138-02/003; 7138-03;
7138-03/002; 7138-03/003; 7138100900
1.1 Warnings and symbols
Warnings
The warnings in this document are intended to
draw your attention to possible injury to persons
or damage to machinery.
The following warning symbols are used:
General warning symbol
Warning – dangerous high voltage
Warning – hot surfaces
Warning - automatic start-up of the unit
Biohazard warning
The warnings are structured as follows:
SIGNAL WORD
Description of the type and source of
danger
Here you will find the possible conse-
quences of ignoring the warning
❯Follow these measures to avoid the
danger.
The signal word differentiates between four levels
of danger:
–DANGER
Immediate danger of severe injury or death
–WARNING
Possible danger of severe injury or death
–CAUTION
Risk of minor injuries
–NOTICE
Risk of extensive material/property damage
Other symbols
These symbols are used in the document and on
or in the unit:
Note, e.g. specific instructions regarding
efficient and cost-effective use of the unit.
Refer to Operating Instructions.
Wear protective gloves.
Wear protective goggles.
Disconnect all power from the unit.
Refer to the accompanying electronic
documents.
XX
YY
Lower and upper temperature limits
xx %
xx %
Lower and upper humidity limits
Protective ground connection
Important information
9000-606-79/30 1912V003 3
EN

CE labelling with the number of the noti-
fied body
Serial number
Order number
Medical device
Health Industry Bar Code (HIBC)
Manufacturer
1.2 Copyright information
All circuits, processes, names, software pro-
grams and units mentioned in this document are
protected by copyright.
The Installation and Operating Instructions must
not be copied or reprinted, neither in full nor in
part, without written authorisation from Dürr
Dental.
2 Safety
Dürr Dental has designed and constructed this
unit so that when used properly and for the
intended purpose it does not pose any danger to
people or property.
Despite this, the following residual risks can
remain:
– Personal injury due to incorrect use/misuse
– Personal injury due to mechanical effects
– Personal injury due to electric shock
– Personal injury due to radiation
– Personal injury due to fire
– Personal injury due to thermal effects on skin
– Personal injury due to lack of hygiene, e.g.
infection
2.1 Intended purpose
The suction unit provides the dental treatment
unit with vacuum and volume flow.
2.2 Intended use
Working in combination with the suction unit with
treatment unit, suction handpiece and cannula,
the media used in dental treatment (e.g. water,
saliva, dentine and amalgam) are removed by
suction for disposal.
This unit is technically suitable for the aspiration
of nitrous oxide (laughing gas). However, when
assembling a system for aspiration of nitrous
oxide, it is important to ensure that the other
components in the system are also suitable for
this purpose. Those responsible for setting up
the system must assess this and approve and
release the system for the aspiration of nitrous
oxide.
Operation with nitrous oxide is only per-
mitted if the exhaust air is transported
from the unit to the outside of the build-
ing.
2.3 Improper use
Any use of this appliance / these appliances
above and beyond that described in the Installa-
tion and Operating Instructions is deemed to be
incorrect usage. The manufacturer cannot be
held liable for any damage resulting from incor-
rect usage. The operator will be held liable and
bears all risks.
❯Do not use this device to aspirate flammable or
explosive mixtures.
Important information
4 9000-606-79/30 1912V003
EN

❯The unit must not be used as a vacuum
cleaner.
❯Do not use chemicals containing chlorine or
foaming chemicals.
❯Operation in operating theatres of explosive
areas is not permissible.
❯The suction unit must not be set up in the
patient environment (with a radius of 1.5 m).
2.4 General safety information
❯Always comply with the specifications of all
guidelines, laws, and other rules and regula-
tions applicable at the site of operation for the
operation of this unit.
❯Check the function and condition of the unit
prior to every use.
❯Do not convert or modify the unit.
❯Comply with the specifications of the Installa-
tion and Operating Instructions.
❯The Installation and Operating Instructions
must be accessible to all operators of the unit
at all times.
2.5 Combining devices safely
Take care when connecting units together or to
parts of other systems as there is always an ele-
ment of risk (e.g. due to leakage currents).
❯Only connect units when there can be no
question of danger to operator or to patient.
❯Only connect units when it is safe to do so and
when there is no risk of damage or harm to the
surroundings.
❯If it is not 100% clear from the unit data sheet
that such connections can be safely made or if
you are in any doubt, always get a suitably
qualified person (e.g. the manufacturer) to ver-
ify that the setup is safe.
Where applicable, the requirements for medical
products have been taken into account in the
development and construction of the device. As
a result, this device is suitable for installation
within medical supply equipment.
❯Where this device is integrated in other medical
supply equipment, the requirements of Euro-
pean Union Medical Device Regula-
tion 2017/745 and the relevant standards must
be observed.
2.6 Specialist personnel
Operation
Unit operating personnel must ensure safe and
correct handling based on their training and
knowledge.
❯Instruct or have every user instructed in han-
dling the unit.
The following groups are not permitted to
operate or use a commercially operated unit:
– People without the necessary experience and
knowledge
– People with reduced physical, sensory or men-
tal capabilities
– Children
Installation and repairs
❯Installation, readjustments, alterations,
upgrades and repairs must be carried out by
Dürr Dental or by qualified personnel specifi-
cally approved and authorized by Dürr Dental.
2.7 Notification requirement of
serious incidents
The operator/patient is required to report any
serious incident that occurs in connection with
the device to the manufacturer and to the com-
petent authority of the Member State in which
the operator and/or patient is established/resi-
dent.
2.8 Electrical safety
❯Comply with all the relevant electrical safety
regulations when working on the unit.
❯Never touch the patient and unshielded plug
connections on the device at the same time.
❯Replace any damaged cables or plugs immedi-
ately.
2.9 Only use original parts
❯Only use Dürr Dental parts or accessories and
special accessories specifically approved by
Dürr Dental.
❯Only use only original wear parts and replace-
ment parts.
Important information
9000-606-79/30 1912V003 5
EN

Dürr Dental accepts no liability for dam-
ages or injury resulting from the use of
non-approved accessories or optional
accessories, or from the use of non-origi-
nal wear parts or replacement parts.
The use of non-approved accessories,
optional accessories or non-genuine wear
parts / replacement parts (e.g. mains
cable) can have a negative effect in terms
of electrical safety and EMC.
2.10 Transport
The original packaging provides optimum protec-
tion for the unit during transport.
If required, original packaging for the unit can be
ordered from Dürr Dental.
Dürr Dental will not accept any responsi-
bility or liability for damage occurring dur-
ing transport due to the use of incorrect
packaging, even where the unit is still
under guarantee.
❯Only transport the unit in its original packaging.
❯Keep the packing materials out of the reach of
children.
2.11 Disposal
The unit may be contaminated. Instruct
the company disposing of the waste to
take the relevant safety precautions.
❯Decontaminate potentially contaminated parts
before disposing of them.
❯Uncontaminated parts (e.g. electronics, plastic
and metal parts etc.) should be disposed of in
accordance with the local waste disposal regu-
lations.
❯If you have any questions about the correct
disposal of parts, please contact your dental
trade supplier.
An overview of the waste keys for Dürr
Dental products can be found in the
download area at www.duerrdental.com
(document no. P007100155).
Important information
6 9000-606-79/30 1912V003
EN

Product description
3 Overview
4
5
6
1
2
3
1 Combination suction unit
2 Control box
3 Set of connection fittings
4 Suction hose
5 Exhaust air hose
6 Waste hose LW 20
Product description
9000-606-79/30 1912V003 7
EN

3.1 Scope of delivery
The following items are included in the scope of
delivery (possible variations due to country-spe-
cific requirements and/or import regulations):
VS 600, 230 V, 1~, 50 Hz
(basic unit) .. . . . . . . . . . . . . . . . . . . . . . 7128-01
VS 600, 230 V, 1~, 50 Hz
(with accessories) .. . . . . . . . . . . . . 7128-01/002
VS 600, 230 V, 1~, 50 Hz
(Power Tower) .. . . . . . . . . . . . . . . 7128-01/021
VS 600, 230 V, 1~, 50 Hz
(basic unit with accessories) .. . . . . 7128100900
VS 600, 400 V, 3~, 50/60 Hz
(basic unit) .. . . . . . . . . . . . . . . . . . . . . . 7128-02
VS 600, 400 V, 3~, 50/60 Hz
(with accessories) .. . . . . . . . . . . . . 7128-02/002
VS 600, 230 V, 3~, 50/60 Hz
(with accessories) .. . . . . . . . . . . . . 7128-02/003
– Control box
0700-500-50 for model 7128-01/002
0700-500-50 for model 7128100900
0732-100-56 for model 7128-02/002
0732-100-57 for model 7128-02/003
– Set of connection fittings
– Suction hose LW 40
– Exhaust air hose LW 50 (aluminium)
– Waste water hose LW 20
– OroCup
VS 900 S, 230 V, 1~, 50 Hz
(basic unit) .. . . . . . . . . . . . . . . . . . . . . . 7134-01
VS 900 S, 230 V, 1~, 50 Hz
(with accessories) .. . . . . . . . . . . . . 7134-01/002
VS 900 S, 230 V, 1~, 50 Hz
(Power Tower) .. . . . . . . . . . . . . . . 7134-01/021
VS 900 S, 230 V, 1~, 50 Hz
(basic unit with accessories) .. . . . . 7134100900
VS 900 S, 400 V, 3~, 50 Hz
(basic unit) .. . . . . . . . . . . . . . . . . . . . . . 7134-02
VS 900 S, 400 V, 3~, 50 Hz
(with accessories) .. . . . . . . . . . . . . 7134-02/002
VS 900 S, 400 V, 3~, 50 Hz
(Power Tower) .. . . . . . . . . . . . . . . 7134-02/021
– Control box
0732-100-55 for Modell 7134-01/002
0732-100-55 for model 7134100900
0732-100-56 for Modell 7134-02/002
– Set of connection fittings
– Suction hose LW 50
– Exhaust air hose LW 50 (aluminium)
– Waste water hose LW 20
– OroCup
VS 1200 S, 400 V, 3~, 50 Hz
(basic unit) .. . . . . . . . . . . . . . . . . . . . . . 7138-02
VS 1200 S, 400 V, 3~, 50 Hz
(with accessories) .. . . . . . . . . . . . . 7138-02/002
VS 1200 S, 400 V, 3~, 50 Hz
(Power Tower) .. . . . . . . . . . . . . . . 7138-02/021
VS 1200 S, 230 V, 3~, 50 Hz
(with accessories) .. . . . . . . . . . . . . 7138-02/003
VS 1200 S, 400 V, 3~, 60 Hz
(basic unit) .. . . . . . . . . . . . . . . . . . . . . . 7138-03
VS 1200 S, 400 V, 3~, 60 Hz
(with accessories) .. . . . . . . . . . . . . 7138-03/002
VS 1200 S, 230 V, 3~, 60 Hz
(with accessories) .. . . . . . . . . . . . . 7138-03/003
VS 1200 S, 400 V, 3~, 50 Hz
(basic unit with accessories) .. . . . . 7138100900
– Control box
0732-100-61 for Modell 7138-02/002
0732-100-61 for model 7138100900
0732-100-57 for Modell 7138-02/003
0732-100-61 for Modell 7138-03/002
0732-100-59 for Modell 7138-03/003
– Set of connection fittings
– Suction hose LW 50
– Exhaust air hose LW 50 (aluminium)
– Waste water hose LW 20
– OroCup
3.2 Optional items
The following optional items can be used with the
device:
Wall bracket .. . . . . . . . . . . . . . . . . 7130-190-00
Console for floor-mounted installa-
tion .. . . . . . . . . . . . . . . . . . . . . . . . 7130-191-00
Plug & play console .. . . . . . . . . . . 7130-195-50
Noise reduction hood .. . . . . . . . . . 7131-991-00
Surge tank .. . . . . . . . . . . . . . . . . . 7130-991-51
Bacteria filter .. . . . . . . . . . . . . . . . . 0705-991-50
Noise reduction for exhaust air .. . . 0730-991-00
Rinsing unit II .. . . . . . . . . . . . . . . . 7100-250-50
Product description
8 9000-606-79/30 1912V003
EN

Ventilation kit for cabinet installa-
tion .. . . . . . . . . . . . . . . . . . . . . . . . 7122-981-50
Exhaust air valve .. . . . . . . . . . . . . . 0732-020-00
3.3 Consumables
The following materials are consumed during
operation of the device and must be ordered
separately:
Orotol plus (2.5 litre bottle) .. . . . . CDS110P6150
MD 555 cleaner (2.5 litre bottle) .. CCS555C6150
3.4 Wear parts and replacement
parts
The following working parts need to be changed
at regular intervals (refer to the "Maintenance"
section):
Nonreturn valve (pack of 3) .. . . . . 7128-100-03E
Information about replacement parts is
available from the portal for authorised
specialist dealers at:
www.duerrdental.net.
Product description
9000-606-79/30 1912V003 9
EN

4 Technical data
4.1 VS 600
Electrical data 7128-01
7128100900
Rated voltage V 230, 1~
Mains frequency Hz 50
Nominal current A≤5.0
Start-up current A ~ 22
Motor protection * A -
Type of protection IP 24
Protection class I
* Motor winding overheat protector
Connections
Suction connection (outside) mm Æ40
Exhaust air connection (external) mm Æ50
Drain connection, DürrConnect mm Æ20
Media
Max. flow rate with unimpeded flow l/min 1500
Auxiliary air valve setting * mbar/hPa -160
Max. rate of flow of fluids l/min 10
Max. suction height cm 80
* The pressure in the suction system is limited by the supplied auxiliary air valve. The auxiliary air
valve is adjusted to the suction unit and must not be altered.
General data
Max. number of users 2
Duty cycle % 100
Dimensions (H x W x D) cm 48 x 41 x 39
Weight, approx. kg 22
Noise level * ca.
without housing
with housing
dB(A)
dB(A)
65
57
* Noise level in accordance with ISO 3746
Ambient conditions during storage and transport
Temperature °C -10 to +60
Relative humidity % < 95
Product description
10 9000-606-79/30 1912V003
EN

Ambient conditions during operation
Temperature °C +10 to +40
Relative humidity % < 70
Classification
Medical devices class IIa
Product description
9000-606-79/30 1912V003 11
EN

4.2 VS 600
Electrical data 7128-02
Rated voltage V 400, 3~ 230, 3~
Mains frequency Hz 50 60 50 60
Nominal current A≤2.2 ≤2.3 ≤3.8 ≤4.0
Start-up current A ~ 16 ~ 14 ~ 16 ~ 14
Motor protection * A 2.5 4.5
Type of protection IP 24
Protection class I
* Max. permitted setting
Connections
Suction connection (outside) mm Æ40
Exhaust air connection (external) mm Æ50
Drain connection, DürrConnect mm Æ20
Media
Max. flow rate with unimpeded flow l/min 1500 1700 1500 1700
Auxiliary air valve setting * mbar/hPa -160
Max. rate of flow of fluids l/min 10
Max. suction height cm 80
* The pressure in the suction system is limited by the supplied auxiliary air valve. The auxiliary air
valve is adjusted to the suction unit and must not be altered.
General data
Max. number of users 2
Duty cycle % 100
Dimensions (H x W x D) cm 48 x 41 x 39
Weight, approx. kg 22
Noise level * ca.
without housing
with housing
dB(A)
dB(A)
65
57
68
60
65
57
68
60
* Noise level in accordance with ISO 3746
Ambient conditions during storage and transport
Temperature °C -10 to +60
Relative humidity % < 95
Ambient conditions during operation
Temperature °C +10 to +40
Product description
12 9000-606-79/30 1912V003
EN

Ambient conditions during operation
Relative humidity % < 70
Classification
Medical devices class IIa
Product description
9000-606-79/30 1912V003 13
EN

4.3 VS 900 S
Electrical data 7134-01 7134-02
Rated voltage V 230, 1~ 400, 3~
Mains frequency Hz 50 50
Nominal current A≤7.4 ≤3.6
Start-up current A ~ 32 ~ 25
Motor protection * A 10.0 4.0
Type of protection IP 24
Protection class I
* Max. permitted setting
Connections
Suction connection (outside) mm Æ50
Exhaust air connection (external) mm Æ50
Drain connection, DürrConnect mm Æ20
Media
Max. flow rate with unimpeded flow l/min 2300
Auxiliary air valve setting * mbar/hPa -170 -170
Max. rate of flow of fluids l/min 16
Max. suction height cm 80
* The pressure in the suction system is limited by the supplied auxiliary air valve. The auxiliary air
valve is adjusted to the suction unit and must not be altered.
General data
Max. number of users 3 3
Duty cycle % 100
Dimensions (H x W x D) cm 52 x 41 x 43
Weight, approx. kg 29 28
Noise level * ca.
without housing
with housing
dB(A)
dB(A)
65
61
65
61
* Noise level in accordance with ISO 3746
Ambient conditions during storage and transport
Temperature °C -10 to +60
Relative humidity % < 95
Ambient conditions during operation
Temperature °C +10 to +40
Product description
14 9000-606-79/30 1912V003
EN

Ambient conditions during operation
Relative humidity % < 70
Classification
Medical devices class IIa
Product description
9000-606-79/30 1912V003 15
EN

4.4 VS 1200 S
Electrical data 7138-02 7138-03
Rated voltage V 230, 3~ 400, 3~ 230, 3~ 400, 3~
Mains frequency Hz 50 60
Nominal current A≤6.5 ≤3.8 ≤6.8 ≤3.9
Start-up current A ~ 43 ~ 25 ~ 30 ~ 17
Motor protection * A 6.3 4.0 6.3 4.0
Type of protection IP 24
Protection class I
* Max. permitted setting
Connections
Suction connection (outside) mm Æ50
Exhaust air connection (external) mm Æ50
Drain connection, DürrConnect mm Æ20
Media
Max. flow rate with unimpeded flow l/min 2400 2900
Auxiliary air valve setting * mbar/hPa -170 -135
Max. rate of flow of fluids l/min 24
Max. suction height cm 80
* The pressure in the suction system is limited by the supplied auxiliary air valve. The auxiliary air
valve is adjusted to the suction unit and must not be altered.
General data
Max. number of users 4 4
Duty cycle % 100
Dimensions (H x W x D) cm 52 x 41 x 43
Weight, approx. kg 28
Noise level * ca.
without housing
with housing
dB(A)
dB(A)
65
61
69
65
* Noise level in accordance with ISO 3746
Ambient conditions during storage and transport
Temperature °C -10 to +60
Relative humidity % < 95
Ambient conditions during operation
Temperature °C +10 to +40
Product description
16 9000-606-79/30 1912V003
EN

Ambient conditions during operation
Relative humidity % < 70
Classification
Medical devices class IIa
Product description
9000-606-79/30 1912V003 17
EN

4.5 Type plate
VS 600
The type plate is located on the upper part of the
turbine housing.
1
1 Type plate
VS 900 S, VS 1200 S
The type plate is located on the upper part of the
turbine housing.
1
1 Type plate
4.6 Evaluation of conformity
This device has been subjected to conformity
acceptance testing in accordance with the cur-
rent relevant European Union guidelines. This
equipment conforms to all relevant requirements.
Product description
18 9000-606-79/30 1912V003
EN
This manual suits for next models
8
Table of contents
Other Durr Dental Water Pump manuals
Popular Water Pump manuals by other brands

Neilsen
Neilsen CT2437 owner's manual

Xylem
Xylem Flygt 2620.172 Service and repair instructions

EBARA
EBARA 3E Series Original instructions

Biral
Biral A Series Installation and operating instructions

Pentair
Pentair FAIRBANKS NIJHUIS VTSH-SCR Installation, operation and maintenance manual

WilTec
WilTec 51545 Operation manual