E.C.A. ESA1309A100 User manual

SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL
SPYLOS DUVAR TİPİ SPLİT KLİMA KULLANMA KLAVUZU
ESA1309A100
ESA1312A100
ESA1318A100
ESA1324A100
Please read this operation manual before usingthe air
conditioner. Keep this operation manual for future reference
This appliance is filled with R32.
Klimayı kullanmadan önce bu kullanım kılavuzunu okuyunuz.
Kullanım kılavuzunu saklayınız.
Bu cihaz R32 gaz ile doldurulmuştur
0011510304

WARNING:
·If the supply cord is damaged, it must be replaced by the manufacturer,its service agent or
similarly qualified persons in order to avoid a hazard.
·This appliance can be used by children aged 8 years and above and persons with reduced
physical, sensory or mentao capabilities or lack of experience and knowledge if they have
been given superivision or instruction concering use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the appliance. Cleaning and
·The wiring method should be in line with the local wiring standard.
user maintenance shall not be made by children without supervision.
All the cables shall have got the European authentication certificate. During installation, when the
·connecting cables break off, it must be assured that the grouding wire is the last one to be broken off.
The explosion-proof breaker of the air conditioner should be all-pole switch. Distance between its two
contacts should not be no less than 3mm. Such means for disconnection must be incorporated in the
·Make sure installation is done according to local wiring regulation by professional persons.
·
·A leakage explosion-proof breaker must be installed.
Make sure ground connection is correct and reliable.
Read the precautions in this manual
carefully before operating the unit. This appliance is filled with R32.
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
·
Keep this manual where the user can easily nd it.
The appliance must be stored in a room without continuously operating ignition sources (for
example: open flames, an operating gas appliance or an operating electric heater).
Do not pierce or burn.
·
·Be aware that refrigerants may not contain an odour.
·The appliance must be installed, operated and stored in a room with a floor area larger than
3 .
·
·
Do not use a refrigerant other than the one indicated on the outdoor unit(R32) when installing,
moving or repairing. Using other refrigerants may cause trouble or damage to the unit, and
personal injury.
The type of connecting wire is H07RN-F.
wiring.

9
1
2
8
5
10
Contents
PARTS AND FUNCTIONS
OPERATION
INDOOR UNIT INSTALLATION
MAINTENANCE
CAUTIONS
TROUBLE SHOOTING

Parts and Functions
Remote controller
Indoor Unit
Outdoor Unit
4
OUTLET
INLET
CONNECTING PIPING
AND ELECTRICAL WIRING
DRAIN HOSE
4
Actual inlet grille may vary from the one shown in the
manual according to the product purchased
Display board
(adjust left and
ow)
Vertical blade
right air fl
Air Purifying Filter
Inlet
(inside)
Emergency
Switch
Horizontal flap
(adjust up and down air flow
Don't adjust it manually)
Outlet
Inlet grille
6
5
2
1
4
3
6
4
2
1
5
3
(inside)
7
8
Anion generator
10.
12. SWING UP/DOWN button
13.
15. SLEEP button
14. HEALTH button
16.
18. Auto button
19. POWER ON/OFF button
21. TEMP button
22.
TIMER OFF/ON
23.
1. Mode display
Operation mode AUTO FAN
COOL DRY
Remote controller
2. Signal sending display
4. FAN SPEED display
5. LOCK display
6. TIMER OFF display
TIMER ON display
7. TEMP display
3. SWING display
LO MED HI AUTO
Display
circulated
8. Additional functions display
Operation mode
Remote controller
QUIET TURBO
SLEEP
Supplemented
electrical
heating HEALTH
9. TURBO/Quiet button
HEAT button
11. COOL button
FAN SPEED button
LOCK button
Control the lightening and extinguishing
of the indoor LED display board.
17. LIGHT button
20. DRY button
button
SWING LEFT/RIGHT button
24. EXTRA FUNCTION button
25.CANCEL/CONFIRM button
Function: Setting and cancel to the
timer and other additional functions.
26. RESET button
When the remote controller appears
abnormal, use a sharp pointed
article to press this button to reset
the remote.
Function: FAN Healthy airflow
Fahrenheit/Celsius mode conversion
1
2
3
24
23
25
26
20
21
22
19
18
58
7
6
4
15
16
9
10
11
12
13
14
17
Turbo/Quiet Auto
Cool Heat Dry
Health
Sleep
Lock
Timer On
Timer off
Light
Extra Function
Confirm/Cancel
Low-Temperature Heating Operation Down to 10℃
Fresh air A-B yard
1
Display board
1Signal receiver
1
23
2
3
Setting temp.display
Operation mode indicator
1 4
23
(lights up when the compressor is on.)
4
WIFI(Optional)

Operation
Air Flow Direction Adjustment
Base Operation
Remote controller
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective
or lost, and with function of emergency running, air conditoner
can run automatically for a while.
When the emergency operation switch is pressed, the " Pi "
sound is heard once, which means the start of this operation.
When power switch is turning on for the first time and
emergency operation starts, the unit will run automatically in
the following modes:
It is impossible to change the settings of temp. and fan speed,It
is also not possible to operate in timer or dry mode.
Pi
1.
3.Fan function
For each press
changes as follows:
Remote controller:
button fan speed
Display
circulated
LOW MED HI
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
temperature is below 16oC, do not use it in the
Test operation:
Use this switch in the test operation when the room
normal operation.
your finger from the switch: the cooling
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice, release
Test ope ration switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor
unit will run in high speed.
Pi Pi
Room
temperature Designated
temperature
Timer
mode Fan
speed
Operation
mode
Above 23oC 26oC AUTO COOL
No
When restart after remote turning off, the remote controller
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY
otherwise, condensate water might occur.
adjusted to left or at air outlet if all vertical louvers are right.
mode ,
controller will automatically memorize the previous set swing position.
Note:
1.Status display of air flow
2.Left and right air flow adjustment
Pos.1 Pos.2 Pos.3 Pos.4
Pos.5 Pos.6
For each press of button, remote controller
displays as follows :
remote controller:
For each press of button, remote controller
displays as follows :
remote controller:
Cautions:
Press button
Every time the button is pressed, temp.setting
increase 1oC,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1oC,if kept depressed, it will
decrease rapidly
Select a desired temperature.
2.Select temp.setting
Unit start
Press ON/OFF on the remote controller, unit starts.
In HEAT mode,warm air will blow out after a short
periodof the time due to cold-draft prevention function.
When FAN is set to AUTO, the air conditioner automatically
adjusts the fan speed according to room temperature.
Cooling only unit do not have displays and functions
related with heating
Remote
Controller Note
COOL
DRY
HEAT
FAN
In DRY mode, when room temperature becomes
lower than temp.setting+2oC,unit will run intermittently
at LOW speed regardless of FAN setting.
Under the mode of auto operation, air conditioner will
automatically select Cool or Heat operation according
to room temperature.
air conditioner automatically adjusts the fan speed
temperature.
When FAN is set to AUTO, the
according to room
In FAN operation mode, the unit will not operate in
COOL or HEAT mode but only in FAN mode ,AUTO is
not available in FAN mode.And temp.setting is disabled.
In FAN mode,SLEEP operation is not available.
Operation
Mode
AUTO
Vertical flap
COOL/DRY:
HEAT: Initial state
2
Turbo/Quiet Auto
Cool Heat Dry
Temp+
Swing Swing
3
Temp-
Health Extra Function
Timer On
Sleep Timer Off Confirm/Cancel
Lock Light Reset
(This function is unavailable on some models.)

Operation
Comfortable SLEEP 5. When quiet sleeping function is set to 8 hours the quiet
sleeping time can not be adjusted.When TIMER function is
set,the quiet sleeping function can't be set up.After the
sleeping function is set up,if user resets TIMER function, the
sleeping function will be cancelled; the machine will be in the
state of timing-on,if the two
modes are set up at the same
time,
either of their operation time is ended first,the unit will
stop automatically,and the other mode will be cancelled.
Note
When TIMER function is set, the sleeping function can’t be
set up .After the sleeping function is set up,if user resets
TIMER function, the sleeping function will be cancelled; the
machine will be in the state of timing-on.
Note to the power failure resume:
Press the sleep button ten times in five seconds and enter
function after hearing four sounds.And press the sleep button
ten times within five seconds and leave this function after
hearing two sounds.
Press Sleep button , the remote controller will
show , and then achieve to the sleep function.
Press again this
be cancelled.
button , the sleep function will
Sleep
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts,temp.will become
1OChigher than temp.setting.After another 1 hours,
temp.risesby 1 futhe
OCr .The unit will run for further
6 hours then stops Temp. is higher than temp.setting
so that room temperature won’t be too low for your
sleep. Power Failure Resume Function
SLEEP operation starts SLEEP operation stops
Approx.6hrs
If the unit is started for the first time, the compressor will not
start running unless 3 minutes have elapsed. When the power
resumes after power failure, the unit will run automatically,
and 3 minutes later the compressor starts running.
1 hr Rises 1OC
1 hr Rises 1OCHealthy airflow Operation
Temp.setting Unit stop
In COOL, DRY mode
2.In HEAT mode
1 hours after SLEEP mode starts, temp will become Press button to enter additional options,Press this
Extra Function
button continuously, the louvers location will cycle between
in the following three locations, to choose the swing location
what you needed,and then press button to confirm.
O
2 C lower than temp.setting. After another 1 hours,
O
temp decrease by 2 C further. After more another
O
3 hours, temp.risesby 1 C further.The unit will run
for further 3 hours then stops.Temp. is lower than
temp. setting so that room temperature won't be too
high for your sleep.
Confirm/Cancel
Healthy Healthy
airflow Present
airflow
upwarder position
downwarder
3.The cancel of the healthy airflow function
Press button to enter additional options,Press this
Temp.setting Unit stop
Extra Function
button continuously, the louvers location will cycle between
in the following three locations again,and then press
1 hr Decreases 2
O
C
Confirm/Cancel
1 hr Decreases 2
O
C
button to cancel.
Notice: Do not direct the flap by hand. Otherwise, the
grille will run incorrectly. If the grille is not run correctly, stop
for a minute and then start, adjusting by remote
controller.
Note:
1.After setting the healthy airflow function, the position
grill is fixed.
3 hrs
3 hrs
Rises 1
O
C
SLEEP
operation starts SLEEP
operation stops
In HEAT mode
2.In cooling, it is better to select the mode.
3.In cooling and dry, using the air conditioner for a long
time under the high air humidity, condensate water may
occur at the grille .
3
1.Press to starting
Setting the comfort work conditions.
2.The setting of healthy airflow function
3.In AUTO mode
The unit operates in corresponding sleep mode
corresponding sleep mode adapted to the
automatically selected operation mode.
4. In FAN mode
It has no SLEEP function.

Operation
Timer On/Off On-Off Operation TURBO/QUIET Operation
1.After unit starts, select your desired operation mode.
2.Press / button to change TIMER mode.
Timer On Timer off
Turbo/Quiet Auto
Press
Timer On
button "ON 0.5 " will appear ,after 10 seconds 2Cool Heat Dry
the time display will be blank.
Press
Timer off
button "OFF 0.5 " will appear ,after 10 seconds
When you need fast cool or fast dehumidification,you
can choose the Turob function; when you sleep, read,
you can choose Quiet function
the time display will be blank.
Then select your desired TIMER mode (TIMER ON or
TIMER OFF ). " "will flash."or "
Press the bu on, you can switch the “Turbo”
Turbo/Quiet
3.Press / button to set time.
Timer On Timer off
and “Quiet”
Press the button for each time, setting time in the first
12 hours increased by 0.5 hour every time, after 12
hours,increased by 1 hour every time.
will swith as below
(TURBO)(QUIET)
cancel
4.Confirm timer setting
After adjust the time,press button and confirm the
Confirm/Cancel
When running in Turbo,the fan speed is the highest,
when running in Quiet, the fan speed is super slow
time ON or OFF button will not flash any more.
5.Cancel timer setting
Press the button the time display eliminated.
Confirm/Cancel
Hints:
After replacing batteries or a power failure happens, time
setting should be reset.
According to the Time setting sequence of TIMER ON or
TIMER OFF, either Start-Stop or Stop-Start can be
achieved.
Loading of the battery
1Remove the battery cover;
2Load the batteries as illustrated.
2 R-03 batteries, resetting key
(cylinder);
3Be sure that the loading
is in line with the" + "/"-";
HEALTH Operation
(This function is unavailable on some models.) 4Load the battery,then put on the cover again.
Note:
The distance between the signal transmission head and the rece-
iver hole should be within 7m without any obstacle as well.
Press HEALTH button , the remote controller will show
and then achieve to the health function.
Press again this HEALTH button , the health function will be
cancelled.
The anion generatorin the airconditioner can generate
a lot of anion effectively balance the quantity of position
and anion in the air and also to kill bacteria and speed
up the dust sediment in the room and finally clean the
air in the room.
When electronic-started type fluorescent lamp or change- over
type fluorescent lamp or wireless telephone is installed in the
room, the receiver is apt to be disturbed in receiving the signals,
so the distance to the indoor unit should be shorter.
Full display or unclear display during operation indicates the
batteries have been used up. Please change batteries.
If the remote controller can't run normally during operation, please
remove the batteries and reload several minutes later.
4

Indoor Unit Installation
Driver Torque wrench
(17mm,22mm,26mm)
Nipper
Reamer
Hacksaw Pipe cutter
Gas leakage detector or
soap-and-water solution
Hole core drill Flaring tool
Spanner(17,19 and 26mm) Knife
Measuring tape
Necessary Tools for Installation Power Source
Before inserting power into receptacle, check the voltage without
fail.
The power supply is the same as the corresponding nameplate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable
can be reached.Donotextendthecablebycuttingit.
Selection of Installation Place
Place, robust not causing vibration, where the body can be
supported sufficiently.
ƽ
Place, not affected by heat or steam generated in the vicinity,
where inlet and outlet of the unit are not disturbed.
ƽ
Place, possible to drain easily, where piping can be conne-
cted with the outdoor unit.
ƽ
Place,wherecoldaircanbespreadinaroomentirely.
ƽ
Place, nearby a power receptacle, with enough space around.
ƽ
Place where the distance of more than lm from televisions,
radios, wireless apparatuses and fluorescent lamps can be
left.
ƽ
In the case of fixing the remote controller on a wall, place
where the indoor unit can receivesignalswhenthefluore-
scent
ƽ
lamps in the room are lightened.
ƽ
ƽ
ƽ
The distance between the indoor unit and the floor should be more than 2m.
The models adopt HFC free refrigerant R32
more than
10cm
more than 15cm
more than 10cm
Arrangement of piping
directions
Rear left
Left Rear
right
Right
Below
Attention must be paid to
the rising up of drain hose
Please be subject to the actual product purchased,the above picture is just for your reference.
If using the left side drain pipe, make sure the hole is got through.
Drawing for the installation of indoor units
5

Indoor Unit Installation
Fix to side bar andlintel a mountingbar, Which is separately sold, and
then fasten the plate to the fixed mountingbar.
Refer to the previous article, “ When the mounting plate is fi
position of wallhole.
Make a hole of 60 mm in diameter, slightly descending to outside the wall
Installpipinghole cover andsealit off with putty afterinstallation
1. Carry out, based on the neighboring pillars or lintels, a
to be fixed against the wall, then temporarily fasten the plate
with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread
with a weight from the central top of the plate, then fasten securely the
plate with the attachment steel nail.
3. Find the wall hole location A/C using a measuring tape
When the mounting plate is fixed side bar and lintel
A=150mm C=120mm
C=113mm
B=
Ø
60mm
A=70mm
B=
Ø
60mm B=
Ø
60mm
B=
Ø
60mm
30mm
45mm
45mm
30mm
35mm
35mm
B=
Ø
60mm
B=
Ø
60mm
A=120mm C=80mm
A=130mm C=110mm
35mm
35mm
B=
Ø
60mm B=
Ø
60mm
ESA1309A100
ESA1312A100
ESA1318A100
ESA1324A100
Fitting of the Mounting Plate and Positioning of the wall Hole
Lid for right
piping
Lidforunderpipingpipe
Fix with adhesive tape
Lidforleft piping
Indoor/outdoor electric cable and drain hose must be bound with
efrigerant piping by protecting tape.
[ Other direction piping ]
Cutaway, with a nipper, the lidforpiping according to the piping
direction andthen bend the pipe according to theposition of wall
hole. Whenbending, be careful not to crashpipes.
Connect beforehand the indoor/outdoor electric cable, and then
pullout the connected to the heatinsulation of connecting part
specially.
proper leveling
forthe plate
rst fixed “,
for the
Making a Holeon the Wall and Fitting the Piping Hole Cover
Drawing of pipe
Installation of the Indoor Unit
[ Rearpiping ]
Draw pipesandthe drainhose, thenfasten themwiththe adhesive tape
[ Left Left-rearpiping ]
In case of left sidepiping, cut away, with a nipper, the lid forleft
piping.
In case of left-rearpiping,bend the pipes according to the piping
direction to themark of holeforleft-rearpipingwhich is marked on
heatinsulation materials.
1. Insert the drainhoseinto the dent of heatinsulation materials of
indoor unit.
2. Insert the indoor/outdoor electric cable from backside of indoor
unit,and pull it out on the front side, then connect them.
3. Coat the flaringseal face with refrigerant oil and connect pipes.
Cover the connectionpart withheat insulation materials closely,
andmake sure fixingwith adhesive tape
Hang surely the unit body onto the upper
notches of the mountingplate. Move thebody
fromside to side to verify its secure fixing.
In order to fix the body onto the mounting
plate,hold up thebody aslant fromthe
undersideandthen put it down perpendicularly.
Remove terminal cover at right bottom corner of
indoorunit, then take off wiring cover by removing
its screws.
mountingplate
When you unload the indoor unit,please use your hand to arise
slightly and lift the unit aslant until it leaves the mounting plate.
agraffe mounting plate
the body to leave agraffe,then lift the bottom of the body outward
Heat insulation
material
Drainhose
Piping
Pipesupporting
plate
Indoor/outdoor electric cable
IndoorsideOutdoor side
Ø60mm
Wall hole
Thickness of wall
(Section of wall hole) Piping hole pipe
G
When the mounting plate is first fixed
Fixing the indoor unit body
Unloading of indoor unit body
Connectingtheindoor/outdoor Electric Cable
Removingthewiring cover
6

1.Insertfromoutsidetheroomcableintoleftsideofthewall
hole, in which the pipe has already existed.
2. Pull out the cable on the front side, and connect the cable
making a loop.
When connecting the cable, confirm the terminal number of indoor and
outdoor units carefully. If wiring is not correct, proper operation can not
becarriedoutandwillcausedefect.
Insertthecablefromtheback
ƽ
side of the unit, then pull it out on the front side.
Loosen the screws and insert
ƽ
the cable ends fully into terminal block, then
tighten the screws.
Pull the cable slightly to
ƽ
make sure the cables have been properly inserted and
tightened.
After the cable connection,
ƽ
never fail to fasten the connected cable with the
wiring cover.
When connecting the cable after installing the indoor unit
When connecting the cable before installing the indoor unit
Note:
1. If the supply cord is damaged, it must be replaced by the manufacturer or its
service agent or a similar qualified person. The type of connecting wire is
H07RN-F.
2.IfthefuseonPCboardisbrokenpleasechangeitwiththe type of
3.Thewiringmethodshouldbeinlinewiththelocalwiringstandard.
4. After installation, the power plug should be easily reached.
5.Abreakershouldbeincorporatedintofixed wiring. The breaker should be
all-pole switch and the distance between its two contacts should be not less
than 3mm.
T.3.15A/250VAC (Indoor).
To Outdoor unit
Connecting wiring
4G1.0mm
2
Code
indication Trouble description Analyze and diagnose
E1
E2
E4
E7
E14
Heat-exchange
sensor failure
Indoor EEPROM
error
Communication
fault between
indoor and outdoor
units
Indoor fan motor
malfunction
Operation halt due to breaking
of wire inside the fan motor;
Operation halt due to breaking
of the fan motor lead wires;
Detection error due to faulty
indoor unit PCB;
Indoor unit- outdoor unit signal
transmission error due to wiring
error;
Faulty PCB;
Faulty EEPROM data;
Faulty EEPROM;
Faulty PCB;
Faulty connector connection;
Faulty thermistor;
Faulty PCB;
Room temperature
sensor failure
The power source must be exclusively used for air
ƽconditioner.
In the case of installing an air conditioner in a moist place,
ƽplease install
an ea
For installation in other places, use a circuit breaker as far
ƽas possible.
Pipecuttingiscarriedoutwithapipecutterandbursmust beremoved.
After inserting the flare nut, flaring work is carried out.
Power Source Installation
Cutting and Flaring Work of Piping
Flare tool Conventional flaretool
Clutch-type clutch-type(Rigid-type) Wing-nut type (Imperial-type)
A 0~0.5mm 1.0~1.5mm 1.5~2.0mm
rth leakage breaker.
Lean Damage of flare Partial Too outside
Correct Incorrect
On Drainage
It becomes
high midway. The gap with the
ground is too small.
There is the bad
smell from a ditch
It waves.
The end is imm-
ersed in water.
Pleaseinstallthedrainhosesoastobedownwardslopewithoutfail.
Please don’t do the drainage as shown below.
ƽ
ƽ
Please pour water in the drain pan of the indoor unit, and
ƽ
is carried out surely to outdoor.
In case that the attached drain hose is in a room, please
ƽapply heat
insulation to
Less than
5cm
confirm that
drainage
it without fail.
Crack
Indoor unit
CheckItemsforTestRun
Gasleakfrompipeconnecting?
Heat insulation of pipe connecting?
Are the connecting wirings of indoor and outdoor firmly
Is the connecting wiring of indoor and outdoor firmly fixed?
Is drainage securely carried out?
Is the earth line securely connected?
Is the indoor unit securely fixed?
Is power source voltage abided by the code?
Is there any noise?
Is the lamp normally lighting?
Arecoolingandheating(wheninheatpump)performednormally?
Is the operation of room temperature regulator normal?
Please kindly explain to our customers how to
operate through the instruction manual.
inserted to the terminal block?
Ƶ
Put check mark in boxes
Flare tooling die 1.Cut pipe 2.Remove burs
3.Insert the flare nut 4.Flare pipe
ƽ
ƽ
On Drainage
Check for Installation and Test Run
7
6.ESA1312A100 Connecting wiring
4G1.5mm 2

Maintenance
Setting of proper room
temperature
Close doors and windows
during operation
If the unit is not to be used
for a long time, turn off the
power supply main switch.
Use the timer effectively
Use the louvers effectively
Do not block the air inlet
or outlet
Proper
temperature
During cooling operation
prevent the penetration
of direct sunlight with
curtain or blind
OFF
Remote Controller Indoor Body
1.Open the lnlet Grille
2.Detach the standard air filter
3.Attach Air Purifying Filter
4.Attach the standard air filter
(Necessary installation)
5.Close the Inlet Grille
Close the Grille surely
Slide the knob slightly upward to
release the filter, then withdraw it.
Put air purifying filter appliances into the
right and left filter frames.
NOTE:
The photocatalyst air purifying filter will be solarized in fixed
time. In normal family, it will be solarized every 6 months.
Prop up the inlet grille by using a
small device named grille-support
ATTENTION:
Please keep the bacteria-killing medium air purifying filter in
avoid long time directly sunshine
when you stop using it,or its ability of sterilization will be
reduced.
The bacteria-killing medium air purifying filter will be used
for a long time,no need for replacement. But in the period
of using them ,you should remove the dust frequently by
which located in the right side of
the indoor unit.
using vacuum cleaner or flaping them lightly,otherwise ,
its performance will be affected.
the cool and dry conditions
For Smart Use of The Air Conditioner
Replacement of Air Purifying Filter
The white side of the photocatalyst air purifying filter
face outside,and the black side face the unit The green
side of the bacteria-killing medium air purifying filter face
outside,and the white side face the unit.
Do not usewater,wipe the controller
with a dry cloth.Do not use glass
cleaner or chemical cloth.
wipe the air conditioner by using a
soft and dry cloth.For serious stains,
use a neutral detergent diluted with
water.Wring the water out of the
cloth before wiping,then wipe off the
detergent completely.
Air Filter cleaning
Open the inlet grille by pulling it upward.
Remove the filter.
Clean the filter.
Attach the filter.
Close the inlet grille.
Push up the filter's center tab slightly until it is
from the stopper, and remove the filter downward.
Use a vacuum cleaner to remove dust, or wash the filter with
water.After washing, dry the filter completely in the shade.
Attach the filter correctly so that the "FRONT" indication
facing to the front.Make sure that the filter is
fixed behind the stopper.If the right
attached correctly, that
Do not use the following for cleaning
Gasoline,benzine, thinner or cleanser
ay damage the coating of the unit. Hot water over 40OC(104OF) may
discoloring or deformation.
Once every
two weeks
mcause
released
is
completely
and left filters are not
may cause defects.
Detach old Air Purifying Filter
8

the power supply cord
and so on.
2.Do not install in the place where there is any
possibility of inflammable gas leakage around the unit.
3.Do not get the unit exposed
to vapor or oil steam.
Cautions
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works
may cause electric shock, fire, water leakage.
Connect the earth
cable.
earthing
WARNING
When abnormality such as burnt-small found,
immediately stop the operation button and
contact sales shop.
OFF
Use an exclusive
power source
with a circuit
breaker
ENFORCEMENT
Connect power supply cord
to the outlet completely Use the proper voltage
Do not use power supply
cord in a bundle. Take care not to damage
the power supply cord.
1.Do not use power supply cord extended
or connected in halfway
STRICT
ENFORCEMENT
STRICT
STRICT
ENFORCEMENT PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
Do not start or stop the
operation by disconnecting
Do not channel the air flow directly
at people, especially at infants or
the aged.
Do not try to repair or
reconstruct by yourself.
Do not use for the purpose of storage of
food, art work, precise equipment,
breeding, or cultivation.
CAUTION
Take fresh air occasionally especially
when gas appliance is running at the
same time.
PROHIBITION
STRICT
ENFORCEMENT
Do not operate the switch with
wet hand.
PROHIBITION
PROHIBITION
PROHIBITION PROHIBITION
PROHIBITION
Do not install the unit near a fireplace
or other heating apparatus. Check good condition of the
installation stand
Do not pour water onto the unit
for cleaning
PROHIBITION
Do not place animals or plants in
the direct path of the air flow
Do not place any objects on or
climb on the unit. Do not place flower vase or water
containers on the top of the unit.
Do not insert objects into the air
inlet or outlet.
PROHIBITION
PROHIBITION
PROHIBITION
STRICT
ENFORCEMENT
Check proper
installation of the
drainage securely
WARNING
9

Trouble shooting
Normal
Performance
inspection
Noise is heard
Phenomenon Cause or check points
The system
immediately.
Smells are
generated.
Mist or steam are
Multiple
check
Poor cooling
When unit is stopped, it won't restart
elapsed to protect the system.
When the electric plug is pulled out
and reinserted, the protection circuit
During unit operation or at stop,
a swishing or gurgling noise may
(This noise is generated by
refrigerant flowing in the system.)
During unit operation, a cracking
noise may be heard.This noise is
temperature changes.
Should there be a big noise from
filter may be too dirty.
This is because the system
circulates smells from the interior
During COOL or DRY operation,
This is due to the sudden cooling
Is power plug inserted?
Is there a power failure?
Is fuse blownout?
Is the air filter dirty?
Are there any obstacles before
Is temperature set correctly?
Are there some doors or
Is there any direct sunlight
through the window during the
Are there too much heat sources
or too many people in the room
In dry mode,
fan
speed can’t be
changed.
In DRY mode, when room temperature
setting+2 oC,unit will run
regardless of FAN setting.
during cooling operation?
cooling operation?(Use curtain)
windows left open?
inlet and outlet?
Normally it should be cleaned
every 15 days.
intermittently at LOW speed
becomes lower than temp.
indoor unit may blow out mist.
of indoor air.
air such as the smell of furniture,
paint, cigarettes.
air flow in unit operation, air
generated by the casing expanding
or shrinking because of
be heard.At first 2-3 minutes after
unit start, this noise is more noticeable.
will work for 3 minutes to protect the
air conditioner.
immediately until 3 minutes have
Cautions
3.If the fuse of indoor unit on PC board is
it with the type of T. 3.15A/ 250V outdoor
broken,change it with the type of T.25A/250V
The refrigerating circuit is leak-proof.
1.Applicable ambient temperature range:
Specifications
The machine is adaptive in following situation
The power plug and connecting cable acquired the local
2. If the power supply cord is damaged, it must be replaced
manufacturer qualified
person.
4. The wiring method should be in line with
the local wiring
5. After installation, the power plug should
be easily reached.
6. The waste battery should be disposed
properly.
7. The appliance is not intended for use
persons
without supervision.
8.Young children should be supervised
with
the appliance.
9. Please employ the proper power plug,
cord.
11.In order to protect the units,please turn
30 seconds
later, cutting off the power.
10.
Cooling
Indoor
Maximum:D.B/W.B
Maximum:D.B/W.B
D.B
Maximum:D.B
D.B
Minimum:D.B/W.B
Maximum:D.B/W.B
Minimum:D.B/W.B
Outdoor
Indoor
Outdoor
Heating
32
o
C/23
o
C
24
o
C/18
o
C
o
C/-8
o
C
43oC/26oC
-10oC
27
o
C
21
o
C/15
o
C
Outdoor
Maximum:D.B/W.B
Minimum:D.B
24
o
C/18
o
C
-15
o
C
(INVERTER)
o
C
7
-
Minimum:
Minimum:
or its service agent or a similar
broken,please
. If the fuse of
standard.
by young children or
to ensure that they
which fit into the
must have
off the A/C first,
Before asking for service, check the following
first.
blown out.
does not restart
by the
change
unit is
infirm
do not play
power supply
attestation.
and at least
15
Do not obstruct or cover the ventilation
conditoner.Do not put fingers
inlet/outlet and swing louver.
This appliance is not intended for use by persons (including children)
with reduced physiced, sensory or mental capabilities or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of appliance by person responsible for
their safety. Children should be supervised to ensure that they do not
play with the appliance.
grille of the air
or any other things into the
10

Üniteyi çal t rmadan önce bu
k lavuzdaki uyar lar dikkatle Bu cihaz, R32 ile doldurulur.
okuyun.
Bu kullan m k lavuzu kullan c n n kolayca bulabilece i bir yerde saklanmal d r.
UYARI:
Buz çözme sürecini hızlandırmak için, üretici tarafından tavsiye edilenden başka, temizleme cihazlarını
kullanmayın.
Cihaz, sürekli çalışan ateşleme kaynakları bulunmayan bir odada saklanmalıdır (örneğin: açık alevler,
çalışan bir gaz cihazı veya çalışan bir elektrikli ısıtıcı).
Delmeyin veya ateşe atmayınız.
Dikkat! Soğutucu akışkanların kokusuz olabileceğini unutmayınız.
Cihazın montajı, çalıştırılması ve saklanması zemin alanı en az “3 m² olan bir odada yapılmalıdır.
Elektrik kablosu hasarl ise,bir tehlike olu mas n önlemek için üretici, servis temsilcisi ya da benzer
nitelikli kiiler taraf ndan de i tirilmesi gerekir.
Bu cihaz,azalm fiziksel ve duyarsal yetenekleri veya tecrübe ve bilgi eksikli i olan ki iler ile8ya aras ve
yukar s ndaki çocuklar taraf ndan kullan labilir. E er onlar güvenli bir ekilde cihaz n kullan m yla ilgili
denetimtalimatalmam sa,çocuklar cihazla oynamamal d r. Temizlik ve kullan c bak m Zamanlayıcı
gözetimi olmaks z n çocuklar taraf ndan yap lamaz.
Kablolama yöntemi yerel kablolama standard ile uyumlu olmal d r.
Kablo ba lant tipi H07RN-F'dir.
Tüm kablolar Avrupa do rulama belgesine sahip olmu tur.Montajs ras nda,ba lantkablolar kesilebilir,
bu topraklama kablosunun en son kesilen kablo oldu undan emin olmal snz.
Klima kesicis n n tüm kutupluanahtar olmaldr; ve iki kontak aras ndaki mesafe 3 mm'den daha az
olmamal d r. Ba lants n n kesilmesi için bu cihazlar kablo içine dahil edilmelidir.
Montaj i lemleri profesyonel ki iler taraf ndan yerel kablolama yönetmeli ine göre yap lmas ndan emin
olun.
Topraklama ba lants n n do ru ve güvenilir oldu undan emin olun.
Bir toprak kaça devre kesicisi monteetti inizden emin olun.
Cihaz hareketli veya tamir s ras nda montajyapmay n,dünite(R32) üzerinde belirtilen so utucudan
ba ka birini kullanmay n.Di er so
açabilir.
utucunun kullan lmas sorun veya ünitenin hasar ve yaralanmalar na yol
çindekiler
PARÇALAR VE LEVLERI……………………………………………………………………………………………….
1
ÇALI MA……………………………………………………………………………………………………………………………
2
ÜN TE KURULUMU
…………………………………………………………………………………………...........
5
BAKIM
…………………………………………………………………………………………………………….
8
DKKAT ED LMES GEREKENLER
…………………………………………………………………………
9
SORUN G DERME
………………………………………………………………………………………………
10

1
2
3
24
23
25
26
15
16
14
17
Turbo/Quiet Auto
Cool Heat Dry
Health
Sleep
Lock
Timer On
Timer off
Light
Extra Function
Confirm/Cancel
20
21
22
19
18
58
7
6
4
9
10
11
12
13
1
Görüntü Paneli
11 4
2323
1
1-Uzaktan kumanda alıcısı
Ortam sıcaklı
2
ıgösterimi
(Uzaktan kontrol sinyali alındı ında, ayar sıcaklı ınıgösterir)
3
Operasyon modu göstergesi
(Kompresör açıldı ında yanar.)
4WIFI (Isteğe bağlı)

Turbo/Quiet Auto
Cool Heat Dry
Temp+
Swing Swing
3
Temp-
Health Extra Function
Timer On
Sleep Timer Off Confirm/Cancel
Lock Light Reset
COOL/DRY:
HEAT:
2
(Bu fonksiyon bu modelde aktif değildir.
sadece Klima üzerinden el ile yapılmaktadır.)

(Bu fonksiyon bu modelde çalışmamaktadır.)
3

/
Timer On Timer off
Timer On
Timer off
Confirm/Cancel
Confirm/Cancel
4

ç ünite Birim Kurulumu
Kurulum için Gerekli Araçlar
Tornavida Tork anahtar
Kesici (17mm,22mm,26mm)
Demir testeresi Boru kesici
Delik karot matkab Geni letme cihaz
Somun anahtar Bçak
(17,19 ve 26mm) erit metre
Gaz sznt alglayc veya Rayba
sabunlu su çözeltisi
Kurulum Yeri Seçimi
Yer, gövdenin yeterli ekilde desteklendi i yerde titre ime neden olmayan
sa lam .
Yer, ünitenin giri ve çk nda da lmayan yer civarnda s veya buhar
tarafndan olu umundan etkilenmemeli.
Yer, borunun d ünite ile ba land yerde kolay drenaj mümkün olmal.
Yer, so uk havann tamamen yaylabildi i bir oda.
Yer, etrafnda yeterli bo alanl bir güç elektrik prizine yan olmal.
Televizyonlar, radyolar, kablosuz aparatlar ve floresan lambalardan 1 m
mesafede olmal.
Uzaktan kumandann bir duvara sabitlenmesi durumunda, floresan lamba
yand nda ünitenin sinyalleri alabilen bir yer olmaldr.
Güç Kayna
Fi i prize takmadan önce voltaj hatasz kontrol edin.
Güç kayna ilgili isim plakasnn ki ile ayndr.
Özel bir güç devresi kablosu kurun.
Bir elektrik prizi güç kablosunun ula labilece i yer mesafesinde kurulmal.
Onu keserek kabloya uzatmayn
ç ünitenin kurulumu için örnek resim
HFC’siz so utucu R32’ya sahip modeller
15 cm den daha fazla
10cm den daha fazla
10cm den daha fazla
Drenaj hortumu
yükseltilirken dikkat
edilmelidir
ç ünite ve yer arasindaki mesafe 2 metreden fazla olma .Lütfensa na nürüne ba z, yuka daki resim sadece size referans olma
içindir.
9k ve 12k için Sıvı Borusu Φ 6.35*0,8 mm
Gaz Borusu Φ 9.52*0,8 mm
18k için Sıvı Borusu Φ 12.7*0,8 mm
Gaz Borusu Φ 9.52*0,8 mm
24 k için Sıvı Borusu Φ 6.35*0,8 mm
Gaz Borusu Φ 12.7*0,8 mm

øç ünite Kurulum
1 Askı Sacı Sabitlenmesi ve Duvar Deli÷inin Pozisyonlanması
Askı Sacı ilk önce sabitlenirken:
1. Mahaldeki sütunlar veya kapı üstü söveleri üzerine dayalı olarak, duvara
karúı uygun bir seviyelendirme levhası yerleútirilmelidir, sonra geçici olarak bir
çivi ile levhayı sabitlenir.
2. Sacın uygun seviyesinden bir kez daha emin olun, levhanın merkezinin
üstünden bir úahkül sarkıtarak, sonra levhayı çelik ba÷lama çivisi ile sa÷lamca
ba÷layın.
3. Bir úerit metre kullanarak duvar delik yerini bulun.
2 Duvarda bir Delik Açın ve Borulama Deli÷i Kapa÷ını Sabitleyin
Ɣ60 mm. çapında bir delik açın (dıúarıya do÷ru azalan hafif meyilli)
ƔBorulama deli÷ini kurun ve onu kurulum sonrasında mastik çekin
Duvar kalınlı÷ı
(Duvar deli÷i bölümü) Borulama deli÷i borusu
3øç Ünite Kurulumu
Boru Çizimi
[ Arka borulama ]
Ɣøzoleli bakır boruları ve drenaj borusunun çekin, sonra onları yapıúkan bant
ile dıútan yapıútırın
[Sol,·Sol-arka borulama]
ƔYan borulama durumunda, bir kesici ile iç unite boru çıkıúkapa÷ını kesin.
ƔSol geri borulama durumunda, ısıtma yalıtım malzemeleri üzerinde
iúaretlenmiúolan sol arka borulama için deli÷in iúareti borulama yönüne göre
boruları bükün.
1. Drenaj borusunu iç ünitenin ısı yalıtım malzemelerinin oyu÷una takın.
2. øç/Dıúünite elektrik kablosunu üç ünitenin arka tarafından takın ve onu ön
taraftan dıúarı çekin, sonra onları ba÷layın.
3. Geniúletme mührü yüzünü so÷utucu ya÷ve ba÷lama boruları ile kaplayın.
Ba÷lantı parçasını ısı yalıtım malzemeleri ile yakın úekilde ba÷layın, ve
yapıúkan bant ile sabitlendi÷inden emin olun
Ɣøç/dıúelektrik kablosu ve drenaj hortumu koruyucu bant ile so÷utucu borusu
ile ba÷lanmalıdır.
[ Di÷er yön borulaması]
ƔKesim, bir kesici ile, borulama yönüne göre borulama için kapak ve sonra
duvar deli÷inin pozisoyonuna göre boruyu bükün. Bükme esnasında, boruları
ezmemeye dikkat edin.
Ɣøç/dıúelektrik kablosunu ba÷lamadan önce ba÷layın, ve sonra ba÷lanmıú
olanı özellikle ba÷lantı parçasının ısı yalıtımına çekin.
øç ünite gövdesi sabitleme:
ƔÜnite gövdesini ba÷lama levhasının üst
çenti÷ine emin úekilde asın. Sabit ba÷lantısından
emin olmak için gövdeyi yan yana taúıyın.
ƔGövdeyi ba÷lama levhası üzerine sabitlemek
için, alt taraftan meyilli úekilde kaldırın ve sonra
dikey úekilde onu aúa÷ıkoyun.
ba÷lama levhası
øç ünite gövdesinin indirilmesi:
Ɣøç üniteyi indirirken, ellerinizi kullanarak çengelden ayırmak için gövdeyi
kaldırın, sonra hafifçe gövdeyi yukarı yönde kaldırın ve birimi meyilli olarak
ba÷lantı levhasında ayrılana kadar kaldırın.
çengel ba÷lama levhası
4øç / DıúElektrik Kablosu Ba÷lantısı
Kablolama kapa÷ının kaldırılması:
Ɣøç ünitenin sa÷alt köúesinde terminal kapa÷ını kaldırın, sonra kablolama
kapa÷ını vidalarını kaldırarak çıkartın.
øç ünite kurduktan sonra kabloyu ba÷larken:
1. Borunun hazır oldu÷u yerde oda kablosunun dıúından duvar deli÷inin içine
takın.
2. Ön tarafta kabloyu dıúarı çekin, ve bir dü÷üm yaparak kabloyu ba÷layın.
Duvar deli÷i
øç ünite tarafı Dıúünite tarafı
A=150mm C=120mm
C=113mm
B=
Ø
60mm
A=70mm
B=
Ø
60mm B=
Ø
60mm
B=
Ø
60mm
30mm
45mm
45mm
30mm
35mm
35mm
B=
Ø
60mm
B=
Ø
60mm
A=120mm C=80mm
A=130mm C=110mm
35mm
35mm
B=
Ø
60mm B=
Ø
60mm
ESA1309A100
ESA1312A100
ESA1318A100
ESA1324A100
6
Ø
60mm
This manual suits for next models
3
Table of contents
Languages:
Popular Air Conditioner manuals by other brands

GE
GE APCA10 Series Owner's manual and installation instructions

LG
LG LS243HLV installation manual

LG
LG LP1415SHR owner's manual

Fujitsu
Fujitsu ABY14LBAJ Service manual

LG
LG LW8016ERY7 owner's manual

Airwell-Fedders
Airwell-Fedders Thru-the-Wall Room Air Conditioner Installation instructions and owner's manual