Eagle Pro EPB Series User manual

Form No. E09005
Rev. A. 09.18.2015
INSTRUCTION MANUAL
EPB SERIES HYDRAULIC PUMPS
Models: EPB-17xx, EPB-50xx, EPB-100xx

EAGLE PRO INDUSTRIAL TOOLS, INC. 2FORM NO. E09005 REV. A.
Carefully inspect all components for shipping damage. If shipping damage is found, notify the carrier at once.
The carrier is responsible for any damage resulting from shipment.
To avoid personal injury or property damage, please read, understand, and follow all safety instructions.
EAGLE PRO is not responsible for injury or damage resulting from unsafe and/or incorrect product use or
system operation, or lack of proper maintenance.
DANGER! Is used only when your action or lack of action may cause serious injury or death.
WARNING! Is used when a potential danger exists that requires correct action to avoid personal injury.
IMPORTANT! Is used when action of lack of action can cause equipment failure.
DANGER!
The hydraulic equipment user must be a qualified operator with correct training and work experience with
hydraulic equipment. Lack of knowledge in any of these areas can lead to equipment damage or personal
injury.
Carefully inspect hydraulic pump before using . If any damage is found, discontinue use and contact your
closest authorized EAGLE PRO Service Center.
To avoid personal injury, do not modify or weld hydraulic equipment without approval of EAGLE PRO
INDUSTRIAL TOOLS, INC.
EPB electric pumps are designed for a maximum of 10,000 PSI/700 bar. Ensure that all hydraulic
equipment (cylinders, hoses, accessories, etc.) used with these pumps are rated at 10,000 PSI/700 bar
pressure rating or equipment damage may occur.
Always stay clear of loads supported only by hydraulic means. A cylinder is a load lifting device, not a
load holding device. After a load has been raised or lowered it must always be supported mechanically.
IMPORTANT!
To avoid personal injury or property damage, please read, understand, and follow all safety instructions.
Always keep work area clean and free of clutter.
When not in use, tools should be properly stored to avoid damage .
Operator must wear proper safety attire when working with hydraulic equipment. Work gloves, safety
glasses, hard hats, approved safety shoes, and hearing protection and/or other required clothing should be
worn while operating this equipment.
01
SAFETY INSTRUCTIONS

EAGLE PRO INDUSTRIAL TOOLS, INC. 3FORM NO. E09005 REV. A.
Use only rigid cribbing pieces to hold loads. Select solid wood or steel blocks that are capable of
supporting the load.
Keep hands and feet away from cylinder and work-piece during operation
Never exceed equipment ratings. Never attempt to lift a load weighing more than the capacity of the
smallest cylinder in the hydraulic system. Overloading will cause equipment failure and possible
personal injury.
Never set the relief valve higher than the maximum rated pressure of the pump. Higher setting may result
in equipment damage and personal injury.
Install pressure gauges to monitor system pressure. System pressure must never exceed maximum rated
pressure of the electric pump.
Do not pick up the hydraulic pump by the power cord, pendant control cord, or hydraulic hose.
Electrical pumps should never be used in a potentially explosive environment.
Ensure that the pump is properly grounded to guard against electrical shock.
Do not use kinked or damaged hydraulic hoses.
Carefully inspect the hydraulic couplers on pump, hoses, and other hydraulic tools before using. Never
connect tools with damaged couplers or damaged port threads. The damaged coupler(s) or damaged port
threads may cause equipment failure and possible personal injury.
Install couplers in a clean environment. Always prevent dirt or other debris from entering into the
cylinder or tool. Dirt or debris will damage the tool and result in equipment failure and possible personal
injury.
Before removing or tightening hose(s) or coupler(s), always release hydraulic pressure in system .
Never handle pressurized hoses; escaping oil under high pressure can penetrate the skin, causing serious
injury. Seek medical aid immediately if injured.
When the pump is not in use, release system pressure, remove the hose(s) and use the dust cap to recover
the port.
Do not drop anything on hydraulic hoses.
Do not use equipment in temperatures of 150°F (65°C) or higher. Overheating will soften seals and
weakens hose materials, resulting in oil leaks or other equipment failure.
Ensure the electric power supply is compatible with the electric pump.
Always disconnect the electric pump from the power supply when performing maintenance or repair.
For hydraulic technical help or repair service, please contact the closet authorized EAGLE PRO Service
Center. EAGLE PRO INDUSTRIAL TOOLS, INC. has no obligations under any warranty with respect
to products that have been repaired by unauthorized personnel, modified, or damaged through misuse,
abuse, accident, neglect, or mishandling.

EAGLE PRO INDUSTRIAL TOOLS, INC. 4FORM NO. E09005 REV. A.
02 INITIAL SETUP INSTRUCTIONS
Visually inspect the pump for any shipping damage. If any damage is found, notify the carrier immediately.
Carrier is responsible for any damage that occurs during shipment.
2.1 Terminology
A. OIL FILLER CAP
B. VENTILATION KNOB
C. OIL LEVEL MONITOR AND THERMOMETER
D. POWER SWITCH
E. PUSH BUTTON CONTROL SWITCH (if applicable)
F. CONTROL VALVE
G. PRESSURE GAUGE
H. RESERVOIR OIL PLUG
2.2 Filling The Oil Reservoir
For shipping safety, the pump has been shipped without hydraulic oil in the reservoir. Remove the pump
from the shipping carton and fill the reservoir with the provided hydraulic fluid.
First, remove the filler cap (A). Using a clean funnel, and the provided hydraulic fluid fill the reservoir.
The reservoir is full when the oil level covers the top oil level gauge (C) .
Once the oil reservoir is full replace the filler cap (A). and properly dispose of the hydraulic fluid
containers.

EAGLE PRO INDUSTRIAL TOOLS, INC. 5FORM NO. E09005 REV. A.
2.4 HYDRAULIC CONNECTIONS
Ensure proper power availability to prevent motor failure or dangerous overloading. Use the recommended
amperage listed on the motor nameplate. Do not use the electric pump if the ground is not connected on the
power plug.
2.3 ELECTRICAL CONNECTIONS
Always minimize the length of extension cords and be
sure they are of adequate wire size, with proper ground
connections. See FIG A. for recommended minimum
wire size (AWG) of any extension cords that are used
with EAGLE PRO electric pumps.
EAGLE PRO recommends using extension cords that
no longer than 25 feet.
WARNING!
Do not operate in a potentially explosive environment, as electric motors may produce sparks.
FIG A
1. Clean all areas around the oil ports of the pump and cylinders or hydraulic tools to be used.
2. Inspect all threads and fittings for wear or damage. Replace if any damage or excessive wear found.
3. Clean all hose ends, couplers or other fittings.
4. Remove the thread protector(s) from the hydraulic oil ports. Thread the hose assembly into the oil port
and attach the hose to the cylinder or hydraulic tool. Use a non-hardening thread sealant to seal the
threads. PTFE tape may be used to seal hydraulic connections if only one layer of the tape is used. Apply
tape carefully, two threads back, to prevent the tape from being pinched by the coupler and broken off
inside the fitting. Any loose pieces of tape could travel through the hydraulic system and obstruct the flow
of oil.
Voltage 115V Voltage 230V, 3PH
Operating Pressure 10,000 PSI/700 Bar Operating Pressure 10,000 PSI/700 Bar
Electrical Requirements 10 AMPS 115V GROUNDED 60HZ Electrical Requirements 8.2 AMPS 230V GROUNDED 60HZ
Motor Rating 0.5HP 115V 60Hz Motor Rating 3HP 230V 3PH 60Hz
Flow Rate 275/17 IN3 Flow Rate 550/50 IN3
Maximum Operating Temp
150° F Maximum Operating Temp 150° F
Voltage 115V
Operating Pressure 10,000 PSI/700 Bar
Electrical Requirements 20 AMPS 115V GROUNDED 60HZ
Motor Rating 1.5HP 115V 60Hz
Flow Rate 550/50 IN3
Maximum Operating Temp
150° F
EPB-17x Series
EPB-50x Series
EPB-100x Series
0-25 FEET 25-50 FEET 50-100 FEET 100-150 FEET
(0-8M) (8-15M) (15-30M) (30-45M)
6 18 (.82) 16 (1.33) 14 (2.09) 12 (3.32)
8 18 (.82) 16 (1.33) 12 (3.32) 10 (5.37)
10 18 (.82) 14 (2.09) 12 (3.32) 10 (5.37)
12 16 (1.33) 14 (2.09) 10 (5.37) 8 (8.37)
14 16 (1.33) 12 (3.32) 10 (5.37) 8 (8.37)
16 16 (1.33) 12 (3.32) 10 (5.37) 8 (8.37)
18 14 (2.09) 12 (3.32) 8 (8.37) 8 (8.37)
20 14 (2.09) 12 (3.32) 8 (8.37) 6 (13.30)
22 14 (2.09) 10 (5.37) 8 (8.37) 6 (13.30)
24 14 (2.09) 10 (5.37) 8 (8.37) 6 (13.30)
26 12 (3.32) 10 (5.37) 8 (8.37) 6 (13.30)
28 12 (3.32) 10 (5.37) 6 (13.30) 4 (21.29)
30 12 (3.32) 10 (5.37) 6 (13.30) 4 (21.29)
CORD SIZE AWG (MM2) 3.2% VOLT DROP
LENGTH OF CORD
AMP
DRAW AT
FULL
LOAD

EAGLE PRO INDUSTRIAL TOOLS, INC. 6FORM NO. E09005 REV. A.
5. Ensure that all couplers, hoses, valves, and other accessories are securely tightened to prevent accidental
removal of components while in use.
6. Ensure all hoses are not kinked or twisted.
WARNING!
Improperly connected hydraulic couplers can be dangerous if pressurized. Do not grab, touch or come in
contact with a pressurized hydraulic fluid leak. Escaping fluid can penetrate the skin and cause severe
injury.
Avoid kinking or tightly bending hoses. If a hose becomes kinked or otherwise damaged, it must be
replaced. Damaged hoses may rupture at high pressure causing personal injury.
3.1 ASSEMBLING THE SYSTEM
The EAGLE PRO EPB electric pumps are shipped with a shipping plug in the 3/8”-NPT oil outlet port(s).
Remove this plug using an 8mm hex head wrench.
For pumps with Single Acting valves, connect the hose assembly into the pump
and attach the hose to the cylinder or hydraulic tool being used. See FIG B.
For pumps with Double Acting valves, connect one hose assembly into the
ADVANCE port (A) and connect this hose to the bottom port on the cylinder or
tool. Connect another hose into the RETRACT port (B) and connect this hose to
the top port on the cylinder or tool. See FIG C.
FIG B FIG C
RETRACT
ADVANCE
03 OPERATION INSTRUCTIONS
WARNING!
Before using, always open the reservoir ventilation knob (B) by
rotating it 2 complete counter-clockwise rotations.

EAGLE PRO INDUSTRIAL TOOLS, INC. 7FORM NO. E09005 REV. A.
3.2 MOTOR AND VALVE OPERATION—SINGLE ACTING
Turn the pump on by pushing the ON/OFF (D) toggle
switch (located on the electrical box ) up, to the ON
position. To operate the pump see the valve operating
diagram below, FIG C.
FIG C
(*) If the electric pump does not feature a pendant control switch, operate the pump using the ON/OFF toggle switch
(D) above
Pendant
Control
Switch
Electric Solenoid
Valve Operation
Hand Wheel EV-4x Valve 2 Button Pendant
Advance CLOSE Turn Handle to A (1) ADVANCE Button A
Retract OPEN Turn Handle to B (2) RETRACT Button R
Hold CLOSE W/Motor Off
A Position or N Position
W/Motor off
Release Button
Pendant
ON/OFF
Toggle Motor On or Off Toggle Motor On or Off Toggle Motor On or Off
Valve Image
Operating
Diagram
Operation
Manual Valve Operation
Electric
Solenoid
Valve
Manual
Control
Valve
Pendant
Control
Valve
Hand
Wheel

EAGLE PRO INDUSTRIAL TOOLS, INC. 8FORM NO. E09005 REV. A.
04 MAINTENANCE
4.1 HYDRAULIC FLUID LEVEL
Before each operation it is important that the fluid level is checked. If the fluid level is low, add hydraulic
fluid as Section 02 Initial Setup shows.
3.2 MOTOR AND VALVE OPERATION—DOUBLE ACTING
Turn the pump on by pushing the ON/OFF (D) toggle switch
(located on the electrical box ) up, to the ON position. To
operate the pump see the valve operating diagram below, FIG
D.
FIG D
IMPORTANT!
In order to ensure proper operation of the electric pump, completely drain and clean the pump reser-
voir every 250 hours, or more frequently if used in dirty environments. In general hydraulic fluid should be a
light yellow and transparent liquid. If hydraulic fluid appears dark or cloudy replace the fluid.
(*) If the electric pump do not have handle control switch, take on or off the power switch (D)
Pendant
Control
Switch
Electric Solenoid
Valve Operation
EV-4x Valve 2 Button Pendant
Advance Turn Handle to A (1) ADVANCE Button A
Retract Turn Handle to B (2) RETRACT Button R
Hold
A Position or N Position
W/Motor off
Release Button
Pendant
ON/OFF
Toggle Motor On or Off Toggle Motor On or Off
Valve Image
Operating
Diagram
Operation
Manual Valve
Operation
Electric
Solenoid
Valve
Manual
Control
Valve
(*) If the electric pump does not feature a pendant control switch, operate the pump using the ON/OFF toggle switch
(D) above

EAGLE PRO INDUSTRIAL TOOLS, INC. 9FORM NO. E09005 REV. A.
4.2 CHANGING THE HYDRAULIC FLUID
Follow the steps below to change the hydraulic fluid.
STEP 1. Ensure pump is unplugged from power source and system
pressure has been released.
STEP 2. Loosen and remove reservoir drain plug using a 6mm hex
wrench. See FIG E.
STEP 3. Drain oil into approved container and dispose of properly
according to local regulations.
STEP 4. Unscrew and remove the bolts holding the reservoir to the top
plate of the hydraulic pump.
STEP 5. Lift the top plate off of the pump reservoir, being careful not
to damage the pump body and set aside.
STEP 6. Clean the pump reservoir and reservoir magnet with a mild cleaning agent and wipe dry. Ensure that
any small pieces of paper towel or rag are removed from the reservoir.
STEP 7. Unscrew the oil filter by hand from the pump body and clean using a mild cleaning agent and a soft
brush. Flush the filter with clean hydraulic fluid to ensure any cleaning agents and/or
small particles have been removed from the filter. If the oil filter is damaged contact the nearest
authorized Eagle Pro service center to order a replacement.
STEP 8. Screw oil filter back onto pump body, be sure to only hand tighten oil filter. Over tightening may
damage the pump body.
STEP 9. Reassemble pump and reservoir.
STEP 10. Once pump is completely assembled, add new, clean ISO #32 hydraulic fluid, see Section 02
Initial Setup Instruction's on how to add hydraulic fluid.
FIG E
Reservoir Oil Drain Plug

EAGLE PRO INDUSTRIAL TOOLS, INC. 10 FORM NO. E09005 REV. A.
05 ELECTRIC PUMP TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION
1. No power or incorrect voltage 1. Check power supply and voltage
2. Damaged power cord 2. Contact your local Authorized Eagle Pro Service Center
3. Tripped circuit breaker 3. Ensure electrical supply is adequate
4. Loose or faulty wiring 4. Contact your local Authorized Eagle Pro Service Center
5. Defective On/Off Switch 5. Contact your local Authorized Eagle Pro Service Center
6. Defective Motor 6. Contact your local Authorized Eagle Pro Service Center
7. Overheated Motor 7. Wait for motor to cool before restarting
1. Ensure electrical supply is adequate
2. If using extension cord ensure correct size
1. Air in system or pump cavitation 1. Follow pump/cylinder instructions fro bleeding air
2. External fluid leak 2. Ensure all connections are tight and properly sealed
3. Internal fluid leak 3. Contact your local Authorized Eagle Pro Service Center
1. External fluid leak 1. Ensure all connections are tight and properly sealed
2. Internal fluid leak 2. Contact your local Authorized Eagle Pro Service Center
3. Pump or valve malfunction 3. Contact your local Authorized Eagle Pro Service Center
1. Load greater than cylinder capacity 1. Reduce load, or select higher capacity cylinder
2. Flow to cylinder blocked 2. Ensure couplers are properly connected
1. Cylinder return spring is damaged 1. Contact your local Authorized Eagle Pro Service Center
2. Valve is not open 2. Ensure pump valve is opened correctly
3. Valve malfunction 3. Contact your local Authorized Eagle Pro Service Center
4. Pump reservoir too full 4. Drain hydraulic fluid to correct level
5. No load on "Load Return" cylinder 5. Add load to cylinder
1. Return flow restricted or blocked 1. Ensure couplers are properly connected
2. Valve is not open 2. Ensure pump valve is opened correctly
3. Valve malfunction 3. Contact your local Authorized Eagle Pro Service Center
1. Incorrect electrical connections
1. Check power supply, voltage, and ensure extension
cord is correctly sized
2. Hydraulic fluid level low 2. Add hydraulic fluid
3. Pump running too long 3. Wait for motor to cool before restarting
4. Work environment too hot
4. Remove from work site. Do not use equipment in
temperatures of 150°F (65°C) or higher
1. Relief valve set too high 1. Contact your local Authorized Eagle Pro Service Center
2. Relief valve malfunction 2. Contact your local Authorized Eagle Pro Service Center
Single Acting Cylinder
Will Not Retract
Double Acting Cylinder
Will Not Retract
Pump Runs Hot
Pump Pressure Too High
Motor Will Not Run
1. Low voltage
Motor Stalls Under Load
Erratic Cylinder
Operation
Pump Will Not Hold
Pressure
Pump Builds full
Pressure, But Load Does
Not Move

EAGLE PRO INDUSTRIAL TOOLS, INC. 11 FORM NO. E09005 REV. A.
06 ELECTRIC PUMP PARTS BREAKDOWNS
6.1 EPB-171A

EAGLE PRO INDUSTRIAL TOOLS, INC. 12 FORM NO. E09005 REV. A.
6.1 EPB-171A CONTINUED
NO Part No. Description QTY NO Part No. Description QTY
1 DQH01 Electric Control Box 1 19 EDYB2.7 Gear Motor 1
2 ML7124/B5 Motor 0.5Hp 115V 60Hz 1 20 EGYB03 Pump Head 1
313005 Bolt (M8*30) 421 EPB-3B5P5A-1 Top Plate 1
413125 Washer (12.3*8.1*2.1) 4 22★24220 O-ring 1
5 XKSB.2 Pendant Switch 1 23 EPB-3B5P5A.1 Block Kit 1
6 YY-3 Plug 1 24 12015 Bolt (M5*12) 2
7★EPB-3B1P2B-1 Motor Gasket 1 25 11004 Bolt (M6*20) 2
811033 Bolt (M6*16) 126 ELYX0500A Oil Reservoir 1
9★QY2-13 Copper washer 10 27★EPB-3B5P5A-2 Reservoir Gasket 1
10 13082 Bolt (M6*16) 528 EPB-3B5P5A-3 Oil Return Tube 1
11 EPA21621.3-1 Air Vent Screw 1 29★24164 O-ring 2
12★24187 O-ring 1 30 EPB-3B5P5A-4 Fitting 1
13 EPA21621.3-2 Oil Cap 1 31★21073 Gasket 2
14★24227 O-ring 1 32 EV42H3A Control Valve 1
15 WU-10*80-J Filter 1 33 13083 Bolt (M6*20) 4
16 EJB107 Fitting 1 34 ETS01 Handle 1
17 EJF106 Fitting 1 35★03.03.0049 Eagle Pro Label 2
18 13013 Bolt (M8*80) 2
Note: ★Denotes items in and only available in pump repair kit: EPB171-RP-A
EPB-171A Parts List

EAGLE PRO INDUSTRIAL TOOLS, INC. 13 FORM NO. E09005 REV. A.
6.2 EPB-175A

EAGLE PRO INDUSTRIAL TOOLS, INC. 14 FORM NO. E09005 REV. A.
6.2 EPB-175A
EPB-175A Parts List
NO Part No. Description QTY NO Part No. Description QTY
1 DQH01 Electric Control Box 1 19 EDYB2.7 Gear Motor 1
2 ML7124/B5 Motor 0.5Hp 115V 60Hz 1 20 EGYB03 Pump Head 1
313005 Bolt (M8*30) 421 EPB-3B5P5A-1 Top Plate 1
413125 Washer (12.3*8.1*2.1) 422★24220 O-ring 1
5 XKSB.2 Pendant Switch 1 23 EPB-3B5P5A.1 Block Kit 1
6 YY-3 Plug 1 24 12015 Bolt (M5*12) 2
7★EPB-3B1P2B-1 Motor Gasket 1 25 11004 Bolt (M6*20) 2
811033 Bolt (M6*16) 126 ELYX0500A Oil Reservoir 1
9★QY2-13 Copper washer 10 27★EPB-3B5P5A-2 Reservoir Gasket 1
10 13082 Bolt (M6*16) 528 EPB-3B5P5A-3 Oil Return Tube 1
11 EPA21621.3-1 Air Vent Screw 1 29★24164 O-ring 2
12★24187 O-ring 1 30 EPB-3B5P5A-4 Fitting 1
13 EPA21621.3-2 Oil Cap 1 31★21073 Gasket 2
14★24227 O-ring 1 32 EV-43M4E Control Valve 1
15 WU-10*80-J Filter 1 33 13083 Bolt (M6*20) 4
16 EJB107 Fitting 1 34 ETS01 Handle 1
17 EJF106 Fitting 1 35★03.03.0049 Eagle Pro Label 2
18 13013 Bolt (M8*80) 2
★Denotes items in and only available in pump repair kit: EPB171-RP-A

EAGLE PRO INDUSTRIAL TOOLS, INC. 15 FORM NO. E09005 REV. A.
6.3 EPB-1710A

EAGLE PRO INDUSTRIAL TOOLS, INC. 16 FORM NO. E09005 REV. A.
6.3 EPB-1710A
NO Part No. Description QTY NO Part No. Description QTY
1 DQH01 Electric Control Box 1 19 BKP1Q0D2.7 Gear Motor 1
2 ML7134(71C4A)Motor 0.5Hp 115V 60 Hz 1 20 EPB-3B10P5A.1 Pump Head 1
313005 Bolt(M8*30) 4 21 EPB-3B5P5A-1 Top Plate 1
413125 Washer (12.3*8.1*2.1) 4 22★24220 O-ring (6.8*1.9) 1
5 XKSB.2 Pendant Switch 1 23 EPB-3B10P5A.2 Block Kit 1
6 YY-3 Plug 1 24 12015 Bolt (M5*12) 2
7 EPB-3B1P2B-1 Motor Gasket 1 25 11004 Bolt (M6*20) 2
811033 Bolt (M6*16) 1 26 ELYX0500A Oil Reservoir 1
9★QY2-13 Copper washer 10 27 EPB-3B5P5A-2 Reservoir Gasket 1
10 13082 Bolt (M6*16) 5 28 EPB-3B5P5A-3 Oil Return Tube 1
11 EPA21621.3-1 Air Vent Screw 1 29★24164 O-ring (8.8*1.9) 2
12★24187 O-ring (2.8*1.8) 1 30 EPB-3B5P5A-4 Fitting 1
13 EPA21621.3-2 Oil Cap 1 31 21073 Gasket (12*9*1.4) 2
14★24227 O-ring (23.6*1.8) 1 32 EV42H2 Control Valve 1
15 WU-10*80-J Filter 1 33 13083 Bolt (M6*20) 4
16 EJB107 Fitting 1 34 ETS01 Handle 1
17 EJF106 Fitting 1 35★03.03.0049 Eagle Pro Label 2
18 13013 Bolt (M8*80) 2
Note: ★Denotes items in and only available in pump repair kit: EPB1710A-RP-A
EPB-1710A Parts List

EAGLE PRO INDUSTRIAL TOOLS, INC. 17 FORM NO. E09005 REV. A.
6.4 EPB-502SA

EAGLE PRO INDUSTRIAL TOOLS, INC. 18 FORM NO. E09005 REV. A.
6.4 EPB-502SA
NO Part No. Description QTY NO Part No. Description QTY
1 DQH02 Electric Control Box 1 19 EDYB2.7 Gear Motor 1
2 ML8022/B5 Motor 1.5Hp 115v 60Hz 1 20 EGYB08 Pump Head 1
313019 Bolt (M10*30) 421 12016 Bolt (M5*16) 2
413126 Washer (15.7*10.2*2.6) 422 EPB-8B5P8A-1 Top Plate 1
5 XKSB.2 Pendant Switch 1 23★24220 O-ring 1
6 YY-3G/3C Plug 1 24 EPB-8B5P8A.1 Block Kit 1
7★EPB-10B-3 Motor Gasket 1 25 12015 Bolt (M5*12) 2
811033 Bolt (M6*16) 226 11004 Bolt (M6*20) 2
9★QY2-13 Copper washer 12 27 ELYX0750A Oil Reservoir 1
10 13082 Bolt (M6*16) 628★EPB-8B5P8A-2 Reservoir Gasket 1
11 EPA21621.3-1 Air Vent Screw 1 29 EPB-3B5P5A-3 Oil Return Tube 1
12★24187 O-ring 1 30★24164 O-ring 2
13 EPA21621.3-2 Oil Cap 1 31 EPB-3B5P5A-4 Fitting 1
14★24227 O-ring 1 32★21073 Gasket 2
15 WU-10*80-J Filter 1 33 EV-52M2 Control Valve 1
16 EJB107 Fitting 1 34 13083 Bolt (M6*20) 4
17 EJF106 Fitting 1 35 ETS02 Handle 1
18 13013 Bolt (M8*80) 236★03.03.0049 Eagle Pro Label 2
EPB-502SA Parts List
Note: ★Denotes items in and only available in pump repair kit: EPB502-RP-A

EAGLE PRO INDUSTRIAL TOOLS, INC. 19 FORM NO. E09005 REV. A.
6.5 EPB-504SA

EAGLE PRO INDUSTRIAL TOOLS, INC. 20 FORM NO. E09005 REV. A.
6.5 EPB-504SA
NO Part No. Description QTY NO Part No. Description QTY
1 DQH02 Electric Control Box 1 19 EDYB2.7 Gear Motor 1
2 ML8022/B5 Motor 1.5Hp 115v 60Hz 1 20 EGYB08 Pump Head 1
313019 Bolt (M10*30) 421 12016 Bolt (M5*16) 2
413126 Washer (15.7*10.2*2.6) 422 EPB-8B5P8A-1 Top Plate 1
5 XKSB.2 Pendant Switch 1 23★24220 O-ring 1
6 YY-3G/3C Plug 1 24 EPB-8B5P8A.1 Block Kit 1
7★EPB-10B-3 Motor Gasket 1 25 12015 Bolt (M5*12) 2
811033 Bolt (M6*16) 226 11004 Bolt (M6*20) 2
9★QY2-13 Copper washer 12 27 ELYX0750A Oil Reservoir 1
10 13082 Bolt (M6*16) 628★EPB-8B5P8A-2 Reservoir Gasket 1
11 EPA21621.3-1 Air Vent Screw 1 29 EPB-3B5P5A-3 Oil Return Tube 1
12★24187 O-ring 1 30★24164 O-ring 2
13 EPA21621.3-2 Oil Cap 1 31 EPB-3B5P5A-4 Fitting 1
14★24227 O-ring 1 32★21073 O-ring 2
15 WU-10*80-J Filter 1 33 EV-52H4B Control Valve 1
16 EJB107 Fitting 1 34 13083 Bolt (M6*20) 4
17 EJF106 Fitting 1 35 ETS02 Handle 1
18 13013 Bolt (M8*80) 236★03.03.0049 Eagle Pro Label 2
EPB-504SA Parts List
Note: ★Denotes item in and only available in pump repair kit: EPB504-RP-A
This manual suits for next models
3
Table of contents
Popular Water Pump manuals by other brands

PVR
PVR DRY 100 Operating and maintenance instructions

DiamaPro Systems
DiamaPro Systems DP-PUMP10GAL owner's manual

Danfoss
Danfoss APP series Installation, operation and maintenance manual

BUSCH
BUSCH Mink MV 1202 A instruction manual

Griswold
Griswold 811 Installation, operation and maintenance manual

Liberty Pumps
Liberty Pumps Pro370 Series installation manual

SPERONI
SPERONI RSM 3 operating instructions

blueZPring
blueZPring AQUAINOX 200 instruction manual

Bosch
Bosch GardenPump 18 Original instructions

Kamoer
Kamoer KSP-F01A-DC user manual

NIKKISO
NIKKISO CHEMIPON BX Series instruction manual

Xylem
Xylem FLYGT Concertor Installation, operation and maintenance manual