EaseTech ACCURON 7200 Series Installation instructions

eastech
eastech
ACCURON
®
7200
CARTRIDGE METERS
INSTALLATION &
OPERATING
MANUAL
4250 S. 76th E. Ave.
Tulsa, OK 74145
918-664-1212
800-226-3569
Fax: 918-664-8494
email: info@eastechflow.com
FLOW CONTROLS

INSTALLATION & OPERATING MANUAL
SCOPE OF MANUAL
ACCURON CARTRIDGE METER SERIES 7200
This manual contains information concerning the
installation, operation and maintenance of the Accuron
7200 Cartridge Meter. To ensure proper performance of
the meter, the instructions given in this manual should
be thoroughly understood and followed.
Keep the manual in a readily accessible location for
future reference.
Changes and additions to the original edition of this
manual will be covered by a “CHANGE NOTICE” supplied
with the manual. The change notice will explain any
changes made to the product described in this manual.

INSTALLATION & OPERATING MANUAL
UNPACKING & INSPECTION
ACCURON CARTRIDGE METER SERIES 7200
Retain the container and all packing material for possible
use in reshipment or storage.
Visually inspect the product and applicable accessories
for any physical damage such as scratches, loose or
broken parts, or any other sign of damage that may have
occurred during shipment.
Note: If damage is found, request an inspection by the
carrier’s agent within 48 hours of delivery and file a claim
with the carrier. A claim for equipment damaged in
transit is the sole responsibility of the customer.
To avoid damage in transit, Eastech Flow Controls
products are shipped to the customer in special shipping
containers. Upon receipt of the product, perform the
following unpacking and inspection procedures:
Note: If damage to the shipping container is evident
upon receipt, request the carrier to be present when the
product is unpacked.
Carefully open the shipping container following any
instructions that may be marked on the box. Remove all
cushioning material surrounding the product and
carefully lift the product from the container.

INSTALLATION & OPERATING MANUAL
TABLE OF CONTENTS
ACCURON CARTRIDGE METER SERIES 7200
TABLE OF CONTENTS
DailyTotals............................. 63
DataLogger.............................64
SetTime............................ 65
StorageRate......................... 65
SecondaryStorage..................... 66
LogChannels.........................66
LoggedGraph........................ 67
LoggedData......................... 68
AmountStored........................68
ClearData...........................68
SystemSet-up.......................... 69
Display............................. 70
Comm.Ports......................... 70
DisplayModes........................71
TotalReset...........................71
NewPassword........................ 71
DailyTotalReset.......................72
Sensor Option (Reverse Polarity & Power Mode) . . 72
MeterReset..........................73
NewFirmware........................ 73
FactoryAssistance.........................74
GeneralDescription....................... 2,3
General Specifications . . . . . . . . . . . . . . . . . . . . . 4, 5
Installation: Cartridge . . . . . . . . . . . . . . . . . . . . . 7-17
EnclosureMounting.....................18,19
Sensor Cable Preparation
VelocitySensors......................20-25
LevelSensor.......................... 26
Velocity and Level Sensor Wiring . . . . . . . . . . 27-33
PROGRAMMING
..................... 34-37
FunctionKeyF1........................38-40
FunctionKeyF2.......................... 41
FunctionKeyF3.......................... 42
FunctionKeyF4........................43,44
FunctionKeyF5.......................... 45
PROGRAMMING OPTIONS
Overview............................ 46,47
ReviewMeter........................... 49
Program............................... 50
MeasureUnits....................... 51-53
Level (H) Sensor Set-up . . . . . . . . . . . . . . . . . . . 54
Totalizer........................... 55-56
4-20mAOutputs..................... 57-58
Damping.............................59
LostSignalTime........................57
FlowSimulation........................ 60
ContactIntegrator...................... 60
SetPoints............................ 61
Relays...............................62
MeterFactor.......................... 62

3
INSTALLATION & OPERATING MANUAL
2
ACCURON CARTRIDGE METER SERIES 7200
GENERAL DESCRIPTION LOW FLOW MONITORING
Accuracy ±3-5% (act.rate)
Turndown: 60:1 During periods
of minimal flow (Zero to 1/3
pipe diameter), the Accuron
measures flow within it’s low
operating range by utilizing the
highly efficient combination of
a trapezoidal flume and
ultrasonic level sensor.
HIGH FLOW MONITORING
Accuracy ±1-2% (act.rate)
Turndown: 60:1 During periods
of maximum flow (1/3 to full
pipe diameter). The Accuron
measures flow within its high
operating range by utilizing an
extremely accurate area-velocity
system that combines an
ultrasonic level sensor with a
pair of transit-time velocity
sensors.
The Series 7200 Cartridge Meter is designed to measure
flow in open channels or partially filled conduits. The
Cartridge Meter utilizes ultrasonic measurments
techniques to determine fluid velocity and fluid depth
for calculating volume of flow.
The Series 7200 Cartridge Meters are calibrated at the
factory to the application parameters provided by the
customer. On-site calibration of the system is usually
never required.
By combining proven flume/level sensor technology with
chordal transit-time velocity measurements, the Accuron
7200 (pat.pend.) ushers in a new age of highly efficient
open channel flowmeters consistently operating in a 1-
5% (actual rate) accuracy range.
Eastech combines two highly accurate and proven
technologies within a single-dual range unit. Low flows
are consistently measured by an extremely reliable
stainless steel trapezoidal flume/Teflon® level sensor
combination. Higher flows are accurately ascertained by
combining the same Teflon level sensor with a pair of
non-fouling transit-time velocity sensors. Transit-time
chordal measurement is the most viable technique for
predicting average velocity. It provides for detection of
chordal velocity across the entire path of the fluid being
measured.

5
INSTALLATION & OPERATING MANUAL
4
ACCURON CARTRIDGE METER SERIES 7200
GENERAL SPECIFICATIONS
Pipe Size Range 8“ to 24”
Output: Three 4-20mADC isolated; 850 ohms max.Flow,Level and Velocity
Three programmable relays,SPDT .25 amp @ 120 VAC,.5 amp @ 24 VDC
RS-232 Serial Port,9600 – 38400 Baud,Modbus ™ Protocol
RS-485 Serial Port optically isolated,Modbus
12VDC,100ma Maximum
Data Logger & software CD
Display Backlit LCD,160 x 128 pixel Graphic Module
Programming Front panel mounted 24 button keypad
Power 80/240 VAC 50/60 Hz or 12-24 VDC @ 150 mA continuous
Accuracy Low Flow +/- 3 to 5% of actual flow
High flow +/- 1-2% of actual flow
Sensors: Velocity Sensors:
Temperature Range: -20° to 160°F (-30° to 70°C)
Operating Frequency: 1280 KHZ
Housing: PVC
Cable: 30 feet of Triaxial PVC coated (standard)
Optional:1000 ft maximum
Level Sensor:
Temperature Range: -20° to 160°F (-30° to 70°C)
Operating Frequency: 51 KHZ
Housing: Teflon
Cable: 30 feet of Triaxial PVC coated (standard)
Optional:1000 ft maximum
Enclosure IP66,Nema 4x standard
Temperature Range -4° to 158°F (-20° to -70°C)
Optional w/ heater: -40°F to -158°F (-40° to -70°C)
CARTRIDGE:
304 Stainless Steel.
ULTRASONIC LEVEL SENSOR:
The risk and expense
associated with repetitive confined space entry due to
fouled submerged sensor problems is eliminated by
utilizing an “above the flowstream” submersible Teflon
level sensor.
TRAPEZOIDAL FLUME:
The flat straight through bottom
permits the flume to pass debris quite readily and
reduces the problem of sediment build-up upstream of
the flume.
TRANSIT-TIME VELOCITY SENSORS:
Designed to
prevent the accumulation of rags, branches and similar
debris from interfering with the performance of the
transducers.

67
INSTALLATION & OPERATING MANUALACCURON CARTRIDGE METER SERIES 7200
FIELD READY INSTALLATION
THE CARTRIDGE METER IS A SINGLE FACTORY
INTEGRATED UNIT, DESIGNED FOR 30 MINUTE
FIELD INSTALLATION AND VALIDATION.
PRE-SIZED
Each field ready cartridge is pre-sized for it’s intended
application. Gasketed and manufactured of 304 stainless
steel, cartridges are installed within minutes.
PRE-ALIGNED
Installed accuracy is guaranteed through precision
factory alignment and calibration of each component
encased within the cartridge.
PRE-PROGRAMMED
Every Cartridge Meter is factory programmed in strict
accordance to customer supplied operating
specifications.

89
INSTALLATION & OPERATING MANUALACCURON CARTRIDGE METER SERIES 7200
CARTRIDGE INSTALLATION
HARDWARE
(Supplied by Eastech)
Masonry drill bit (1)
Lag shields (4)
Flat washes (10)
Marker (1)
Turnbuckles (2)
Socket Drill Bit (1)
Lag bolts (4)

11
INSTALLATION & OPERATING MANUAL
STEP 2
10
ACCURON CARTRIDGE METER SERIES 7200
STEP 1
Slide the Cartridge into the pipe until the
upstream flange is in contact with the wall.
The Cartridge should be installed in the
incoming pipe of the manhole.

13
INSTALLATION & OPERATING MANUAL
STEP 4
12
ACCURON CARTRIDGE METER SERIES 7200
STEP 3
Use a pencil or marker and mark the four
slotted holes provided in the flange of the
Cartridge. Remove the cartridge from the pipe.
NOTE: If the sewer pipe is not flush with the
sewer wall, utilize the two turnbuckles
provided. Insert the hook end into the hole
below the handle of the Cartridge and attach
other end to the sewer wall with the lag bolt.
Rotate the Cartridge until the bubble in level
provided is centered.

15
INSTALLATION & OPERATING MANUAL
STEP 6
14
ACCURON CARTRIDGE METER SERIES 7200
STEP 5
Insert the lag shields flush to the wall.Using the drill and the masonry drill bit
provided, drill all four holes for the lag shield.

17
INSTALLATION & OPERATING MANUAL
STEP 8
16
ACCURON CARTRIDGE METER SERIES 7200
STEP 7
Re-insert the Cartridge. Line up the slots
with the lag shield holes and screw the lag
bolts with the flat washers through the
flange in the Cartridge and snug tight.
If installing the Cartridge in a round manhole,
it may be necessary to use flat washers as
spacers between the Cartridge flange and
the wall.

19
INSTALLATION & OPERATING MANUAL
18
ACCURON CARTRIDGE METER SERIES 7200
ENCLOSURE MOUNTING
Hinge Lock and Optional Key Lock
Two plastic gray plugs are supplied with the Accuron
meter housing. The plugs may be utilized to
permanently lock either side of the cover by inserting
them into the keyhole. The optional Keylock may than
be used to lock and unlock the other side of the cover.
The key can only be removed if the cover is in the locked
mode.
Do not face the display towards the sun. A sunshade
must be used for outdoor installation. Conduit
openings must be properly prepared and sealed to
maintain the NEMA 4X rating.
The enclosure is rated IP
66 (NEMA 4X) and can be mounted indoors or out. There
are two stainless steel mounting brackets attached to the
enclosure.
The mounting tabs have slots for 1/4” bolts (4 places). The
electronics should be mounted with the display at eye
level or lower. There are five 1/2” holes in the bottom of
the enclosure for conduit fittings. These holes have rubber
plugs installed at the factory.
Opening the Enclosure:
There are two hinged floor clasps on the front cover of the
enclosure. To open, place thumb on one of the hinges, pull
toward the outside of the enclosure. Once the hinge pops
to the outside it will retract allowing the clasp at the
bottom of the hinge to release. Swing the cover towards
the front to open. The opposite side will act as a hinge to
swing the door freely. To close, re-attach the hinge into the
clasp and push the top of the hinge toward the enclosure
until it locks.
9.32”
8.25”
12.625”
13.25” 8.875”

21
INSTALLATION & OPERATING MANUAL
20
ACCURON CARTRIDGE METER SERIES 7200
SENSOR CABLE PREPARATION
2.
Remove outer shield. Measure 1-3/8” from the end of
the cable. With a pair of small side cutters, cut the shield
around the cable at the measured point and remove the
outer shield.
VELOCITY SENSORS (PAIR)
IMPORTANT
Before pulling the sensor cables through the conduits,
mark the ends of the cables to indicate which is the
upstream and downstream sensor cable. Leave
approximately 1 foot of cable extending from the
conduit in the enclosure. Prepare the cable ends in the
following manner.
NOTE: All Drawings are to scale.They may be used as a
template.
1.
Remove outer cable cover.
Measure 1-7/8” from the end of
the cable. With a cutting tool,
carefully cut through the outer
cover making sure not to cut into
the outer shield. Remove the
outer cover.
1-3/8”
1-7/8”
Remove
Outer
Shield
Remove
Outer
Cover
1
2

23
INSTALLATION & OPERATING MANUAL
22
ACCURON CARTRIDGE METER SERIES 7200
4.
Remove middle shield. Measure 3/4” from the end of
the cable. With a pair of small side cutters, cut the shield
around the cable and remove middle shield.
3.
Remove middle cover. Measure 1-1/8” from the end of
the cable. With a cutting tool, carefully cut through the
middle cover making sure not to cut into the middle
shield. Remove the middle cover.
3/4”
Remove
Middle
Shield
1-1/8”
Remove
Middle
Cover
34

25
INSTALLATION & OPERATING MANUAL
24
ACCURON CARTRIDGE METER SERIES 7200
USE DRAWING BELOW AS TEMPLATE
FOR CONFIRMATION
OF CORRECT CABLE PREPARATION
5.
Remove inner cover. Measure 1/2” from the end of the
cable. With a cutting tool or pair of wire strippers,
carefully cut the inner covering, making sure not to cut
into the center conductor. Remove the inner cover.
1/2”
1/4”
3/8”
1/4”
1/2”
Completed
Cable
1/2”
Remove
Inner
Cover
5

27
INSTALLATION & OPERATING MANUAL
VELOCITY &
LEVEL SENSOR
WIRING
26
ACCURON CARTRIDGE METER SERIES 7200
LEVEL SENSOR
CABLE PREPARATION
SINGLE LEVEL SENSOR
Red Wire:
Strip wire approximately 1/4 to 3/8”
White Wire:
Strip wire approximately 1/4 to 3/8”
Black, Green and Shield Wires:
Strip black and green wire and crimp all
three wires into the spade lug provided.
RED WHITE
BLACK,
GREEN, SHIELD

28 29
INSTALLATION & OPERATING MANUALACCURON CARTRIDGE METER SERIES 7200
METER ENCLOSURE WIRING METER WIRING DIAGRAM
There are three terminal strips provided for all wiring of the Accuron
7200. the AC power terminal is separate from the other two terminal
strips. The power terminal strip has three connections for High (Hot),
Low (Neutral), and Ground for AC voltage only. Refer to the wiring
diagram below for all internal wiring connections. The unit may also
be powered with 12-24 VDC at row B. Terminals 1 (+) and 2 (-).
The bottom of the Accuron enclosure is
furnished with (5) 1/2” conduit entrances
23451
PE
B
A
NC
C
NO
NC
C
NO
NC
C
NO
–
+
–
+
–
+
N/A
N/A
B
A
GNO
CTS
RTS
RX
TX
N/A
N/A
–
+
–
+
–
+
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
ProfiBus
Relay #3
Relay #2
Relay #1
4-20mA DC Out FLOW
4-20mA DC Out VELOCITY
4-20mA DC Out LEVEL
Battery (DC) In
LEVEL
SENSOR
WHITE
RED
RS-485
ROW B
TOP ROW
ROW A
BOTTOM ROW
RS-232
WR
Black, Green & Shield
(Optional)
SM-15
Surcharge
Sensor
WHITE
RED
WR
Black, Green & Shield
VELOCITY
SENSORS
(CHANNEL 1)
DOWNSTREAM
UPSTREAM
GND (ground)
LO (neutral)
HI (hot)
90-240 VAC
50/60 HZ
POWER
G
N
L

30 31
INSTALLATION & OPERATING MANUALACCURON CARTRIDGE METER SERIES 7200
METER WIRING cont. VELOCITY SENSOR
CABLE CONNECTIONS
After the ends of the cables have been prepaired, loosen
the screws on the terminals and remove the two pairs of
clamps on the velocity sensor cable terminal board.
OUTPUTS
3) 4-20 mADC
Isolated into 850 ohms max
Terminals 1-6 (bottom) Flow, Level and Velocity
3 Programmable Relays
SPDT .25 amp @ 120 VAC,
Terminals 7-15 (bottom) .5 amp @ 24 VDC
RS-232 Serial Port
9600-38400 Baud,
Terminals 9-13 (top) Modbus Protocol
RS-485 Serial Port
Optically isolated,
Terminals 14-16 (top) Modbus Protocol
DC Power In
Terminals 1-2 (top) 12 VDC. 100mA maximum
Data Logger & Software CD
Take the upsteam cable and insert the center conductor
into the upstream terminal connection and tighten the
screw. Slightly pull on the cable to insure the wire is
secured to the terminal. Take the downstream cable and
insert the center conductor into the downstream
terminal connection and tighten the screw. Slightly pull
on the cable to insure the wire is secured to the terminal.
Place the two clamps over the top and bottom shields
and secure them into place. Verify that the clamps are
making good contact with the shields and that frayed
shield wires are not extending beyond their own clamp-
down area.
DOWNSTREAM
SEMSOR
UPSTREAM
SEMSOR
CHANNEL 1

33
INSTALLATION & OPERATING MANUAL
LEVEL SENSOR
CABLE CONNECTIONS
32
ACCURON CARTRIDGE METER SERIES 7200
VELOCITY SENSOR
Red Wire: Terminate as shown
White Wire: Terminate as shown
Black, Green and Shield Wires:
Crimp all three wires into the spade lug provided.
Loosen the nut on the wiring termination and slide the
lug under the nut. Hand tighten the nut on top of the
lug wire.
PROPER INSTALLATION CONFIRMATION
Sensor cable connection continuity test.
This test will require the use of an ohmmeter. With the
power off, connect the test leads of the ohmmeter to
Points 1 and 3 of the sensor cable connections on the
sensor terminal block. The ohmmeter should read 10,000
ohms +/- 5%. Repeat this test at Points 2 and 3.
Connect the test leads to Points 3 and 4.
The reading should indicate infinity (or an open).
Connect the test leads to Points 1 and 4, then 2 and 4.
The reading should indicate infinity (or an open).
SENSOR CABLE CONNECTIONS
ON POWER SUPPLY BOARD
UPSTREAM
SEMSOR
DOWNSTREAM
SEMSOR
1
2
3
4
Black, Green & Shield
LEVEL
SENSOR
WHITE
RED
Black, Green & Shield
(Optional)
SM-15
Surcharge
Sensor
WHITE
RED