Eastern Energy 840063 User manual

- 2 -
CONTENTS
Title Page
I. Introduction................................................................... 2
II. Panel escription ......................................................... 3
III. Operating Instructions
A. General Measurement Procedures ......................... 3~4
B. Peak......................................................................... 5
C. ata Hold................................................................. 5
. atra Record ........................................................... 5
E. Automatic Shut Off................................................... 5
F. RS232 PC Serial Interface....................................... 5~6
G. Battery Replacement............................................... 6
H. Optional Accessories............................................... 6
I. Classification Ranges............................................... 6~7
J. ISO 2954 Sensitivity Relative Table ........................ 7
IV. Specifications ............................................................... 7~8
V. Warranty....................................................................... 8
I. INTRODUCTION
The level of vibration is a useful guide to the balance, alignment and gen-
eral condition of pumps, motors, and other machinery. Poor balance, mis-
alignment and looseness results in higher levels of vibration and indicates
maintenance is required for operational as well as safety reasons.
Measures velocity and acceleration. The large display indicates RMS,
Peak, min-max, hold, and low battery. Features auto power off and an
RS232 computer interface. Comes ready to use in a foam-lined, hard-
shell carrying case, with a detachable strongly magnetic probe, 9V battery
and instructions.
www.eastern-energy.net
Email: [email protected]

- 3 -
II. PANEL DESCRIPTION (fig. A)
III. OPERATING INSTRUCTIONS
A. GENERAL MEASUREMENT PROCEDURES
1. Attached the BNC PLUG (A11) to the BNC SOCKET (A10).
2. Attached the MINI PLUG (A12) to the INPUT SOCKET (A13).
3. a. Acceleration (ACC) Measurement:
Switch the ACC/VEL SELECTOR (A7) to the "ACC" position.
b. Velocity (VEL) Measurement:
Used for general industrial vibration. Switch the ACC/VEL
SELECTOR (A7) to the "VEL" position.
4. Switch the RMS/PEAK SELECTOR (A4) to the "RMS" position.
5. Press the POWER BUTTON (A2) once to turn on the meter.
1. ISPLAY
2. POWER BUTTON
3. HOL BUTTON
4. RMS/PEAK SELECTOR
5. RECOR BUTTON
6. RECALL BUTTON
7. ACC/VEL SELECTOR
8. BATTERY COVER
9. RS232 OUTPUT TERMINAL
10. BNC SOCKET
11. BNC PLUG
12. MINI PLUG
13. INPUT SOCKET
14. VIBRATION SENSOR
15. MAGNETIC BASE
9
2
5
11
12
13
14
15
10
1
4
3
7
6
8
www.eastern-energy.net
Email: [email protected]
www.eastern-energy.net

- 4 -
6 a. If the surface material of the object
you are testing is a non-magnetic
material, hold the VIBRATION
SENSOR and touch the tip to the
object (above).
b. If the surface material is magnetic,
connect the VIBRATION SENSOR
to the MAGNETIC BASE (left) and
touch it to the object's surface
(below).
www.eastern-energy.net
Email: [email protected]

- 5 -
B. PEAK VALUE
Switch the RMS/PEAK SELECTOR (A4) to the "PEAK" position.
Peak value = 1.414 RMS value.
C. DATA HOLD
1. Press the HOLD BUTTON (A3) during measurement to freeze the
displayed value. " .H" is shown on the LC .
2. Press the HOLD BUTTON (A3) a second time to resume
measurement.
D. DATA RECORD (Displays t e Maximum and Minimum readings.)
1. To start the ata Record function, press the RECORD BUTTON (A5)
once. The LC display will indicate "REC."
2. Press the RECALL BUTTON (A6) and the "Max" symbol (along with
the maximum value) will appear on the LC display.
3. Press the RECALL BUTTON (A6) again and the "Min" symbol (along
with the minimum value) will appear on the display.
4. To exit the memory record function, press and hold the RECORD
BUTTON (A5) for approximately 2 seconds. The display will revert
back to the current reading.
E. AUTOMATIC SHUT OFF
This unit has a built-in automatic shut off function to prolong battery life.
The meter will shut off automatically if no buttons are pressed within 10
minutes. To deactivate this feature, select the memory record function
during measurement, by pressing the RECORD BUTTON (A5).
F. RS232 PC SERIAL INTERFACE
The unit features an RS232 output via 3.5 mm Terminal. The connector
output is a 16 digit data stream which can be utilized by user's specific
application. An RS232 lead with the following connection will be required
to link the instrument with the PC serial input.
The 16 digit data stream will be displayed as follows:
Meter (3.5 mm jack plug) PC (9W " " Connector)
Center Pin Pin 2
Ground/Shield Pin 5
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
www.eastern-energy.net
Email: [email protected]

- 6 -
Each digit indicates the following status:
G. BATTERY REPLACEMENT
When the top left corner of LC display indicates "LBT," it is time to
replace the battery. Accurate readings may be taken for several hours
after the low battery indicator appears. Open the battery cover, install a
fresh 9V battery and replace the cover.
H. OPTIONAL ACCESSORIES
850080 Software
840094 RS232 to USB Adaptor Cable
840055 RS232 cable 48" required for use w/software
840090 Water Resistant Instrument Pouch
I. CLASSIFICATION RANGES
There are 4 different machine groups with 4 classification ranges and
O End Word
1 to 4 Upper isplay reading, 1=LS , 4=MS
5 to 8 All "?" (?, ?, ?, ?)
9 ecimal Point( P), position from right to the left ;0 = No
P, 1 = 1 P, 2 = 2 P, 3 = 3 P
10 to 14 All Zeros (0, 0, 0, 0, 0)
15 Start Word
RS232 FORMAT: 9600, N, 8, 1
GROUP K: Small mac ines, especially production electrical motors
of up to 15 KW.
Good 0 ~ 0.71 mm/s
Acceptable 0.72 ~ 1.80 mm/s
Still permissible 1.81 ~ 4.5 mm/s
angerous > 4.5 mm/s
Good 0 ~ 1.12 mm/s
Acceptable 1.13 ~ 2.80 mm/s
Still permissible 2.81 ~ 7.1 mm/s
angerous > 7.1 mm/s
GROUP M: Medium sized mac ines, especially electrical motors
wit 15 to 75 KW output, wit out special foundations.
www.eastern-energy.net
Email: [email protected]

- 7 -
IV. SPECIFICATIONS
Range Resolution Accuracy
Acceleration 0.5 ~ 199.9 m/s
2
0.1 m/s2 +/- (5% +2d) rdg,
160 Hz, 80 Hz.
@ 23 +/- 5ºC
Velocity 0.5 ~ 199.9 mm/s 0.1 mm/s
GROUP G: Large mac ines on eavy foundations.
Good 0 ~ 1.80 mm/s
Acceptable 1.81 ~ 4.50 mm/s
Still permissible 4.51 ~ 11.2 mm/s
angerous > 11.2 mm/s
GROUP T: Largest mac ines and turbo mac ines wit
special foundations.
Good 0 ~ 2.80 mm/s
Acceptable 2.81 ~ 7.10 mm/s
Still permissible 7.11 ~ 18.0 mm/s
angerous > 18 mm/s
J. ISO 2954 Sensitivity Relative Table
Frequency Hz Relative sensitivity
Normal Value Minimum Value Maximum Value
10 1.0 0.8 1.1
20 1.0 0.9 1.1
40 1.0 0.9 1.1
80 1.0 1.0 1.0
160 1.0 0.9 1.1
500 1.0 0.9 1.1
1000 1.0 0.8 1.1

- 8 - Rev. 6/1/11
SPECIFICATIONS (continued)
Frequency 10 Hz~ 1 KHz, sensitivity relative during the frequency
range meets ISO 2954 (see pg 6).
Weight Meter with battery: 10 oz (230 g).
Probe with magnetic base: 2 oz (50 g).
imension Meter: 17" × 3" × 1 ½" (80 × 75 × 35 mm)
Probe cord: 49" (125 cm), probe diameter: (19 mm)
isplay 61 mm x 34 mm super large LC display.
15 mm (0.6") digit size.
Calibration
Point
Velocity: 50 mm/s (160 Hz)
Acceleration: 50 m/s
2
(160 Hz)
Sampling
time
Approx. 1 second.
Operating
conditions
Temperature: 0 ~ 50°C (32 ~ 122°F)
Humidity: Less than 80% R.H.
Power
supply
Alkaline or heavy duty type C 9V battery.
Power
consumption
Approx. C 6 mA.
Circuit Exclusive microcomputer circuit.
V. WARRANTY
Sper Scientific warrants this product against defects in materials and
workmanship for a period of one (1) year from the date of purchase, and
agrees to repair or replace any defective unit without charge. If your
model has since been discontinued, an equivalent Sper Scientific product
will be substituted if available. This warranty does not cover probes, bat-
teries, or damage resulting from accident, misuse, or abuse of the prod-
uct. In order to obtain warranty service, simply ship the unit postage pre-
paid to:
SPER SCIENTIFIC. 7720 East Redfield, Suite 7 Scottsdale, AZ 85260
(480) 948-4448, info@sperscientific.com, www.sperscientific.com.
The defective unit must be accompanied by a description of the problem
and your return address. Register your product online or return your
warranty card within 10 days of purchase.
Table of contents
Other Eastern Energy Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

SEC
SEC Signature DIR Instruction and operation manual

Apera Instruments
Apera Instruments DO8500 instruction manual

Afikim
Afikim Afi-lite Plus user manual

Cropico
Cropico DO5003 user manual

Molecular Devices
Molecular Devices SpectraMax i3x installation guide

Vivax Metrotech
Vivax Metrotech vLocPro Series Procedure