EAW CIS6 User manual

CIS6
Ceiling Loudspeaker
INSTRUCTION MANUAL

2 – CIS6
CIS6 – 3
1. SAFETY INSTRUCTIONS
1. Read Instructions
2. Keep these Instructions
3. Heed all Warnings
4. Follow all Instructions
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Do not block any ventilation openings. Install in
accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as
radiators, heat registers, stoves, or other apparatus
(including ampliers) that produce heat.
9. Only use attachments/accessories specied by the manufacturer.
10. Refer all servicing to qualied service personnel. Servicing is required when the apparatus
has been damaged in any way, such as liquid has been spilled or objects have fallen into the
apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.
11. The entire sound system must be designed in compliance with the current standards and laws
regarding electrical systems.
12. When installing and using this apparatus, keep in mind the technical specications indicated in the
dedicated section of the manual.
13. Exposure to high sound levels can cause permanent hearing loss. The sound pressure level which
leads to hearing loss varies considerably from one person to another, and depends on the duration
of exposure. The U.S. Government’s Occupational Safety and Health Administration (OSHA) has
established the maximum sound pressure levels that can be with stood without causing damage,
which are shown in the table below. According to the OSHA regulations, any exposure over the
maximum limits indicated in the table can reduce the hearing capacity of a person. To prevent
potentially dangerous exposure to high sound pressure levels, anyone subjected to such levels
must use suitable protection. When a EAW Commercial product capable of producing high sound
levels is being used, it is therefore necessary to wear ear plugs or protective earphones when
the limits shown in the table are exceeded. Consult the specications provided in the instruction
manual to know the maximum sound pressure (SPL) the loudspeaker is capable of producing.
repnoitaruD
)sruoh(yad
leveldnuoS
)ABd( elpmaxelacipyT
8 09 b
ulcllamsaniouD
6 2
9
4 59 n
iartyawbuS
3 7
9
2 0
01 cisumlacissalcduolyreV
5.1 201
1 5
01 teef05taevitomocoL
5.0 011
sselro52.0 511 trecnockcoratastraptseduoL
WARNING! This equipment has
been designed to be installed
by qualied professionals
only! There are many factors
to be considered when
installing professional sound
reinforcement systems,
including mechanical and
electrical considerations, as
well as acoustic coverage
and performance. EAW
Commercial strongly
recommends that this
equipment be installed only by
a professional sound installer
or contractor. Part No. 0010797 Rev. A 05/2004
© 2004 LOUD Technologies Inc. All Rights Reserved.
CAUTION AVIS
RISK OF ELECTRIC SHOCK • DO NOT OPEN
RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED PERSONNEL
ATTENTION: POUR EVITER LES RISQUES DE CHOC
ELECTRIQUE, NE PAS ENLEVER LE COUVERCLE. AUCUN
ENTRETIEN DE PIECES INTERIEURES PAR L'USAGER. CONFIER
L'ENTRETIEN AU PERSONNEL QUALIFIE.
AVIS: POUR EVITER LES RISQUES D'INCENDIE OU
D'ELECTROCUTION, N'EXPOSEZ PAS CET ARTICLE
A LA PLUIE OU A L'HUMIDITE
The lightning flash with arrowhead symbol within an equilateral triangle is
intended to alert the user to the presence of uninsulated "dangerous voltage"
within the product's enclosure, that may be of sufficient magnitude to constitute
a risk of electric shock to persons.
Le symbole éclair avec point de flèche à l'intérieur d'un triangle équilatéral est
utilisé pour alerter l'utilisateur de la présence à l'intérieur du coffret de "voltage
dangereux" non isolé d'ampleur suffisante pour constituer un risque d'éléctrocution.
The exclamation point within an equilateral triangle is intended to alert the user
of the presence of important operating and maintenance (servicing) instructions
in the literature accompanying the appliance.
Le point d'exclamation à l'intérieur d'un triangle équilatéral est employé pour
alerter les utilisateurs de la présence d'instructions importantes pour le fonction-
nement et l'entretien (service) dans le livret d'instruction accompagnant l'appareil.

2 – CIS6
CIS6 – 3
TABLE OF CONTENTS
1. SAFETY INSTRUCTIONS........................................................ 2
2. INTRODUCTION....................................................................... 3
3. INSTALLATION ........................................................................ 4
4. CONNECTIONS........................................................................ 5
5. SPECIFICATIONS..................................................................... 6
6. SERVICE INFORMATION........................................................ 7
7. WARRANTY ............................................................................. 7
2. INTRODUCTION
This manual describes the CIS6 loudspeaker. This is designed for quick ush-mounting
ceiling installation.
The HF and LF drivers are coaxially mounted for a smooth frequency response and
a symmetrical projection pattern. This results in an attractive design and good acoustic
features for quality speech and music reproduction.
The loudspeaker is equipped with a line transformer that makes it possible to connect it
to constant voltage sound systems at 70 V or 100 V. The transformer has four taps, allowing
a selection of power ratings to suit your system.
The steel bracket is tted with unique clamps that can signicantly reduce its installation
time. The grille assembly is rmly attached from behind the bafe. The driver/bafe assembly
then easily installs in the premounted bracket with spring-loaded hardware. This results in a
solid attachment method that also provides a cosmetically clean appearance.
Applications include:
• Meeting Rooms
• Hotels
• Transportation Terminals
• Multizone Paging/Music Systems
• Healthcare Facilities
• Commercial Ofces
• Conference Rooms
• Schools

4 – CIS6
CIS6 – 5
3. INSTALLATION
The metal bracket provided with each loudspeaker offers quick installation into ceilings.
WARNING: Make sure that the loudspeaker is installed in a stable and secure
way in order to avoid any conditions that may be dangerous for persons or structures:
• Check to make sure that the ceiling has the necessary mechanical characteristics to
support the weight of the loudspeaker without the danger of it falling.
• Before suspending the loudspeaker, carefully check all the components to be used to
make sure there is no damage, deformation, corrosion and/or missing or damaged
parts that could reduce the safety of the installation.
Installation precautions
• Use speaker cables with an adequate cross-section (gauge). The greater the distance
between the amplier and loudspeaker, the larger the connection cable cross-section
should be.
• To prevent inductive phenomena causing humming or distortion, the speaker cables
should not be run together with electrical energy conductors, microphone cables,
or line-level audio lines. Use speaker cables that have markings to distinguish the
polarity, such as insulation or conductors of different colors.
Installation procedure
1. Cut a 7.87” (200 mm) hole in the ceiling, using all safety precautions to avoid cutting
power lines, water lines etc.
2. Take the bracket, loosen the two
wing bolts, and slide the xing plates
upwards. Press the bracket up into the
ceiling hole.
3. When the bracket is securely pushed up inside the
hole, slide the xing plates down to grip the top
surface of the ceiling. Tighten up the two wing
bolts to hold the bracket in place.
4. Offer up the Loudspeaker and attach the spring
clips to one side of the bracket.

4 – CIS6
CIS6 – 5
4. CONNECTIONS
WARNING: To prevent the risk of electric shock, do not
connect the loudspeaker or change the power selector taps
with the amplier switched on.
1. Connect your amplier output to the terminals on the
loudspeaker. The loudspeaker negative terminal connects
to the negative amplier output, the loudspeaker positive
terminal connects to the positive amplier output.
2. Use the tables in the specication section
to select the power rating for the voltage
line you are using (70 V or 100 V). Move the
positive line to transformer terminals 1, 2,
3 or 4, depending on your required power
rating. Leave the negative on the COM
terminal (common).
3. When the connections are securely made, connect
the other spring clip to the bracket, and press
the loudspeaker upwards until it is ush with the
ceiling.
Precautions
• Before using the loudspeaker, carefully check that all the connections have been
made correctly to make sure there are no accidental short circuits that could cause
electrical sparks.
• Check if your power amplier’s constant output voltage is 70 V or 100 V, and nd the
rated power output.
• The sum of the operating power values of all the loudspeakers connected to the
audio line must not exceed 80 % of the amplier’s output power.
• Verify that the connections to all of your loudspeakers are made correctly “in phase.”
When different loudspeakers reproduce the same frequencies but with phase
differences, there may be sound cancellation. Loudspeakers are often situated in
adjacent positions and the sound waves interact with each other. If a loudspeaker is
connected incorrectly; i.e., the polarity of the audio line conductors is inverted, the
audio signals are transmitted with differences in phase and correct reproduction is
therefore jeopardized. Most notably, the bass response may suffer.
COM
1234
+GND
COM
1234
+GND
GND

6 – CIS6
CIS6 – 7
5. SPECIFICATIONS
Power Selector
• Leave the negative wire on the COM terminal, and
move the positive wire to terminals 1, 2, 3 or 4
depending on the desired power rating.
Disclaimer
EAW Commercial continually engages in research related to product improvement, new
materials, and production methods. Design renements are introduced into existing products
without notice as a routine expression of that philosophy. For this reason, any current EAW
Commercial product may differ in some respect from its published description, but will
always equal or exceed the original design specications unless otherwise stated.
“EAW Commercial” is a trademark of LOUD Technologies Inc.
All other brand names mentioned are trademarks or registered trademarks of their
respective holders, and are hereby acknowledged.
Rated Power 6 W
Driver 6.5” coaxial
SPL (1 W/m) 93 dB
Max SPL (6 W/m) 100 dB
Freq Range (-10 dB) 100 Hz-20 kHz
Dispersion (1 kHz/4 kHz) 120˚/90˚
Ceiling Cutout diam 7.87”/200 mm
Grill outer diameter 9.06”/230 mm
Height 4.33”/110 mm
Weight 2.65 lbs/1.2 kg
Terminal 70 V Power (W) 100 V Power (W) Impedance
1 3 6 1.67 kΩ
2 1.5 3 3.33 kΩ
3 0.75 1.5 6.67 kΩ
4 0.375 0.75 13.33 kΩ
COM
1234
+GND
Cutout Diameter
Grill Diameter
Height

6 – CIS6
CIS6 – 7
6. SERVICE INFORMATION
In the event that your CIS loudspeaker should require servicing, please follow these
instructions:
1. Call EAW Commercial Tech Support at 1-888-337-7404, 7 am to 5 pm PST
(Monday-Friday), to verify the problem and obtain a Return Authorization (RA)
Number. Be sure to have the serial number of the unit when you call. You must have
a Return Authorization Number in order to obtain warranty service at the factory or at
an authorized service center. You can also email EAW Commercial Tech Support at:
2. Pack the unit in its original packaging. THIS IS VERY IMPORTANT. LOUD Technologies
is not responsible for any damage that occurs during shipping due to non-
conventional packaging. Original packaging helps to minimize the possibility of
shipping damage.
3. Include a legible note stating your name, (no P.O. boxes), daytime phone number,
Return Authorization Number, and a detailed description of the problem, including
how we can duplicate it.
4. Write the Return Authorization Number in BIG BOLD PRINT on top of the box.
5. Tech Support will tell you where to ship the unit when you call for an RA Number. We
suggest insurance for all forms of cartage.
7. WARRANTY
Warranty: LOUD Technologies Inc. requires its authorized EAW Commercial distributors
abide by the following warranty terms for all EAW Commercial brand products (all dates
are from the date of delivery from an Authorized EAW Commercial Distributor to the end
user/installation site):
Loudspeakers – 5 years; Active Electronics – 5 years; Accessories – 2 years.
What Is Covered: Defects in workmanship and materials and against malfunctions. EAW
Commercial distributors must remedy all such defects and malfunctions without charge
for parts or labor if the warranty applies. Final determination of warranty coverage lies
solely with each authorized EAW Commercial distributor.
What Is Not Covered: This warranty does not extend to damage or malfunctions
resulting from, but not limited to, shipment, improper installation, misuse, neglect,
abuse, normal wear, accident, or to any product on which the serial number has been
modied or removed. Exterior defects in or damage to the exterior appearance are
specically excluded from this warranty. EAW Commercial distributors shall not be liable
for incidental or consequential damages resulting from the use of EAW Commercial
products. Repairs and/or modications by other than an Authorized EAW Commercial
Distributor automatically voids this warranty.

EAW Commercial | One Main Street | Whitinsville, MA 01588 USA
TEL toll free within US/Canada 888.337.7404 | TEL outside US 425.892.6503 | FAX 425.485.1152
www.eawcommercial.com
© 2004 LOUD Technologies Inc. All Rights Reserved. EAW Commercial is a registered trademark of LOUD Technologies Inc.
Table of contents
Other EAW Speakers manuals