Measuring
Hypochlorous
Acid (HOCl) Solutions
THINGS TO KNOW:
•The molecular formula for hypochlorous acid is HOCl
•HOCl is a free chlorine molecule that can be measured with chlorine test paper
•HOCl is most dominant in a chlorine solution between pH 4 and 6
1. This appliance is not to be used by persons (including children)
with reduced physical, sensory or mental capabilities or lack of
experience or knowledge, unless they have been given supervision
or instruction.
2. This appliance should not be used by children and care should be
taken when used near children.
3. To protect against risk of electrical shock, do not immerse the
appliance base or power supply unit in water or other liquid. Do
not clean in a dishwasher.
4. Turn appliance o before cleaning.
5. Use only with the detachable power unit that was provided with
the appliance. Do not operate the appliance with a damage cord
or plug.
6. Appliance is designed to be supplied from a seperate extra-low
voltage (SELV) power source; risk of electrical shock are minimal
under normal conditions.
7. Store additives in a clean and dry location.
8. Only use normal tap water or purified water.
9. If the unit becomes damaged or leaks, immediately disconnect
from the power supply at the wall.
10. To clean unit, rinse only with tap water.
11. Empty the pitcher after use and rinse with tap water.
PRECAUTIONS
Disclaimer: The content of this document is furnished for informational use only and is subject to change without notice. The generation of free
chlorine solutions of HOCl can vary due to differences in water quality therefore measurements in parts per million (ppm) are
approximations. Manufacturer assumes no responsibility or liability for errors or inaccuracies in the content of this manual.
Generating Electrolyzed
Water for Cleaning &
Degreasing
Generates potassium hydroxide (KOH) with an
ORP between -100 and -300.
1. Add tap water (or purified water) up to the 1 Liter mark
2. Add 2 grams of potassium carbonate *
3. Replace lid and connect power supply **
4. Power On to Setting 3 to generate KOH in 8 minutes
* Use only the potassium carbonate additive.
** Power supply connector must be dry
1 LITER MARK
HOW TO MEASURE THE CONCENTRATION OF HYPOCHLOROUS ACID
Chlorine test paper provides a simple, reliable, and economical means to measure the concentration of free
chlorine in sanitizing solutions. With color matches at 10, 50, 100 and 200 parts per million (ppm), tst
paper measures concentrations between 10 and 200 ppm. 10 50 100 200