Installation & Operation Manual
Proven Quality since 1892
ECON hand diaphragm pump Fig.951 www.eriks.com
Rev.
6. Application
The ECON hand diaphragm pumps are used for suction of water, fuel and oil. The hand
diaphragm pumps are designed for standard operating conditions. For the use of extreme
conditions e.g. aggressive or abrasive media, it is recommended to mention this at the ordering
stage, to verify whether the hand diaphragm pump is suitable. The installation designer is
responsible for the hand diaphragm pump, suitable for the working conditions. The hand
diaphragm pumps are unsuitable, without written permission of an ERIKS company, to apply for
hazardous media as referred into Regulation (EC) No 1272/2008
7. Installation
During the assembly of the hand diaphragm pump, the following rules should be observed:
- make sure, before assembly, that the hand diaphragm pump is not damaged during
transport or storage, are executed according request, are to your order specification and
are suitable for the job.
- take off dust caps of the threaded connections of the pump.
- make sure that the thread on the suction line is executed in the same standard as the
pump connection and also free from pollution.
- choose a position for example on the tank which is flat and unobstructed, the pump must
be mounted in a vertical position with the handle upright and with the suction-side
connection underneath. For mounting use the lugs on the back side of the pump.
- the best height of the hand diaphragm pump is when the handle can be used in the most
easy and ergonomically way.
- please consider that the handle must be used and therefor needed is enough free space
in front of the hand diaphragm pump, to avoid any possible injury during operation.
- the handle is secured by a bolt (dismounting of the handle is possible)
- the suction-line or hose must be mounted deep enough in the fluid, please consider a
max. suction height of 7 Meter. A requirement is that on the end of the suction line a
strainer with check valve function is mounted.
- the max. possible feed height of the hand diaphragm pump is 15 Meter.
- for a god functioning of the pump, please check if the connections are air tight, Teflon tape
must be used to reach the best sealing.
- please consider a max. capacity of 0,65 Liter/cycle
8. Maintenance
During maintenance, the following rules must be observed:
- always keep personal safety precautions in mind and always use appropriate protection
e.g. clothing, masks, gloves etc.
- when working on the hand diaphragm pump it is recommended to remove the handle.
- be alert that the temperature still can be very high or low and can cause burns.
- make sure that the pressure is reduced to atmospheric pressure, that the suction and
pressure line is disconnected and that the fluid is drained, when opening the pump.
- dust, grease and medium residual, must be frequently removed from the pump body and
all moving parts, to maintain all operating functions.
9. Service and repair
All service and repair jobs should be carried out by authorized staff, using suitable tools and user
shall use genuine valve parts.
- welding repair and drilling of the pump is forbidden.
- when the pump is blocked, open the pump with all safety precautions in mind. Remove
the dirt and close the cover by turning the bolts evenly and double check if the diaphragm
is fitting correctly.
- after replacement of the diaphragm, it is necessary to check the pump operation and
tightness of all connections. Leakage test should be carried out.
- after installation, the pump should be checked and maintained periodically at least every 3
months, depending on the medium.