Ecovolt Zero1 User manual

1
ECO VOLT | ZERO1
Operation Instruction For the user and the qualied installer
www.ecovolt.ie
De-centralised MVHR
Zero1 Manual

CONTENT
SAFETY REQUIREMENTS
INTRODUCTION
USE
DELIVERY SET
MAIN TECHNICAL PARAMETERS
DESIGN AND OPERATING LOGIC
MOUNTING AND SET-UP
CONNECTION TO POWER MAINS
CONTROLS
MAINTENANCE
TROUBLESHOOTING
STORAGE AND HANDLING
ECO VOLT | ZERO 1
Unit 3B Rosemount Park Drive,
Rosemount Business Park,
Dublin 11, Ireland
Info@ecovolt.ie
www.ecovolt.ie
03
05
05
05
06
07
09
11
12
13
15
16

3
ECO VOLT | ZERO1
Operation Instruction For the user and the qualied installer
SAFETY
REQUIREMENTS
Read the user’s manual carefully
prior to the operation and installation
of the decentralized ventilation with
heat recovery.
Installation and operation of the
Zero1 shall be performed in
accordance with the present user’s
manual as well as the provisions
of all the applicable local and
national construction, electrical and
technical codes and standards.
The warnings contained in the
presentuser’s manual must be
considered most seriously since
they contain vital personal safety
information.
Failure to follow the safety regulation
may result in an injury or
ventilator damage.
Keep the manual in a safe place for
future referencing
Info@ecovolt.ie
www.ecovolt.ie
Symbol legend used in the manual:
WARNING!
Ventilator mounting safety precautions
DO NOT!
The ventilator must
be disconnected
from the power
supply prior to
every installation
or repair operation.
The ventilator must
not be operated
outside the
temperature range
stated in the user’s
manual or in
aggressive or
explosive
environments.
The electrical
connections must
be completed by
a competent and

ECO VOLT | ZERO1
Operation Instruction For the user and the qualied installer
Do not use dam-
aged equipment
or conductors to
connect the Zero1 to
power mains.
While installing the
Zero1 follow the
safety regulations
of electric tools.
Unpack the
Zero1 with care.
Use the Zero1 only
as intended by the
manufacturer.
Zero1 operating safety
precautions precautions
Do not touch the
controller or the
remote control with
wet hands. Do not
carry out the Zero1
maintenance with
wet hands.
Do not let
children operate
the Zero1.
Do not wash the
Zero1 with water.
Protect the Zero1
electric parts from
water ingress.
Do not block the air
duct when the
Zero1 is on.
Disconnect the Zero1
from power supply
before maintenance.
Do not damage the
power cable while
operating the Zero1.
Do not put any
objects on the power
cable.
Keep explosive
products away
of the Zero1.
Do not open the
operating Zero1.
In case of unusual
sounds, or smoke,
disconnect the Zero1
from power supply
and contact the
service centre.
from the Zero1 be
directed to the open
candles.

5
ECO VOLT | ZERO1
Operation Instruction For the user and the qualied installer
INTRODUCTION
This user’s manual included technical
operation, installation and mounting
guidelines for the de-centralised
MVHR Zero1.
USE
The Zero1 is designed for permanent
air exchange in domestic and
commercial buildings that are
extremely well insulated and have
got good airtightness with low heat
loss. The Zero1 is suitable for nZEB
and Passive type buildings
The Zero1 is designed for wall
mounting on external walls between
The Zero1 is rated for continuous
operation always connected to
power mains.
Exchanged air must not contain any
evaporation of chemicals, coarse
dust, soot and oil particles, sticky
pathogens or any other harmful
substances.
THE ZERO1 IS NOT INTENDED TO BE
USED BY CHILDREN OR PERSONS
WITH PHYSICAL OR MENTAL
DISABILITIES. ALL INSTALLATIONS
MUST BE CARRIED OUT
BY QUALIFIED AND
COMPETENT PERSON
DELIVERY SET
Zero1 1 item
Fastening set 1 item
Remote controller 1 item
User’s manual 1 item
Packing box 1 item

6ECO VOLT | ZERO1
Operation Instruction For the user and the qualied installer
MAIN TECHNICAL PARAMETERS
The Zero1 is designed for indoor
application with the ambient
-
tric appliance.
The Zero1 design is regularly
improved, so some models may
slightly differ from those ones
described in this manual.
242.00
242.00
220.00
242.00
30.10
56.00
¶µ153.20
¶µ157.60
¶µ215.50
¶µ159.00
87.87
250.00-400.00
ZERO1 OVERALL
DIMENSIONS (MM)
Speed
3
Max. Transported Air Temperature
Heating Core
I II III
3.9
651 956
Ceramic

ECO VOLT | ZERO1
Operation Instruction For the user and the qualied installer
DESIGN AND OPERATING LOGIC
The zero1 consists of the telescopic air duct with adjustable length
to regulate the position of the inner air duct inside the outer air duct
with the ventilation unit and external louver.
objects onto the ceramic core and the fan.
or replacing
The Zero1 uses the warm extracted air to heat up the ceramic core.
The ceramic core is equipped with a pull cord to remove it from the
inner sleeve, the ceramic core also acts as a sealant too.
The ventilation part of the Zero1 must be installed on the inner
section of the wall. During standby mode the unit is equipped with
shutters to prevent any back draft. The ventilation louver must be
installed on the external section of the wall.

ECO VOLT | ZERO1
Operation Instruction For the user and the qualied installer
Inner Ducting
Separated Frame
Ceramic Heating
Exchange Core
Pre-Filter
Separated Frame
Outer Ducting
Rubber Ring
Air Louvre
Cover
Panel
Noise Reduction EVA
Buttons
Top shell
Chassis
Mounting Plate
Round Frame
DC Brushless Motor
Blade

9
ECO VOLT | ZERO1
Operation Instruction For the user and the qualied installer
ZERO1 OPERATING
MODES
The Zero1 has three operating modes:
Fresh Air Mode: The unit supplies fresh
air only
Extract Mode: The unit extracts stale
and moist air only
Cycle Mode: The unit works in supply
and extract mode
In cycle mode the Zero1 operates in
two cycles for 65 seconds each. During
cycle 1, the warm stale air is extracted
of the heat to the core to be utilised in
and pulls fresh air from the outside. This
fresh air passes through the ceramic
core and is heated thus returning this
heat back into the building.
This process is repeated continuously
MOUNTING
AND SET-UP
READ THE USER’S
MANUAL PRIOR
TO MOUNTING
THE ZERO1
CAUTION!
THE ZERO1 MUST NOT BE
INSTALLED IN AREAS WHERE
THEY WILL BE COVERED BY
BLINDS, CURTAINS OR DRAPES

ECO VOLT | ZERO1
Operation Instruction For the user and the qualied installer
MOUNTING
THE ZERO1
1. Identify the location where the unit will
through the wall envelope as shown
below.
the external wall as shown below
A
A
SECTION A-A
max200mm(max7
max90mm
(max7 £©
R100
(R4°±)
916°∞
78°∞
3. Mark the cable entry for the power
cables and drill a hole in the mounting
plate for the cables. Ensure the airtight-
ness layer for the building is not com-
promised at this point.
-
Fix the mounting plate to the wall with
the screws and plugs provided. Align the
telescopic duct to the mounting plate
and seal the gap between the wall and
the telescopic duct with approved air
tightness sealant or tape. The telescopic
wall level of the internal wall.
max A
160
Inside Outdoors

11
ECO VOLT | ZERO1
Operation Instruction For the user and the qualied installer
that order.
6. nstall the ventilation unit onto the
mounting plate. The ventilation unit is
Switch off the mains power at the con-
sumer unit. Connect the live conductor
to the live terminal marked L. Connect
the neutral conductor to the terminal
marked N. Connect the earth conductor
CONNECTION TO
MAINS POWER
ALL ELECTRICAL WORK MUST BE
CARRIED OUT BY QUALIFIED
PERSON

ECO VOLT | ZERO1
Operation Instruction For the user and the qualied installer
ZERO1 CONTROLS AND REMOTE
CONTROL OPTIONS
Electrical parameter
Emission current<5mA
Effective control distance: partition
ON/OFF
Speed
Switching
Mode
Switching
ON/OFF
Press with
a beep
Press with
two beeps
Press with
three beeps
Press with
a beep
Press with
two beeps
Press with
three beeps
Low Speed
Middle Speed
High Speed
Fresh Air Mode
Exhaust Mode
Cycle Mode
ON/OFF
Low Speed
Middle Speed
High Speed
Fresh Air Mode
Exhaust Mode
Low Humidity
Medium Humidity
Night Mode
Cycle Mode
High Humidity

13
ECO VOLT | ZERO1
Operation Instruction For the user and the qualied installer
OPERATING CONTROLS
FROM THE ZERO1 UNIT
1. Turning the Zero1 on. Adjusting the
speed
Press with
a beep
Press with
two beeps
Press with
three beeps
Low Speed
Middle Speed
High Speed
OFF
Turning the ventilator OFF.
1. Turning Zero1 ON/OFF
ON/OFF
Set the speed switch to OFF position
and the Zero1 mode switch to position
to enable remote control of the Zero1
REMOTE CONTROL
ON/OFF
If Night mode is activated, the Zero1
when the light is turned off. Activation of
sound signal. Exiting the night mode is
3. Speed setting
Low Speed
Middle Speed
High Speed
Fresh Air mode. Air is supplied
to the room at a set speed
Exhaust mode. Air is extracted
speed.
Cycle mode.
The Zero1 operates 65 seconds
in Supply mode and then 65
seconds in Exhaust mode with
heat regeneration.
5. Humidity control. Humidity control
is possible only in Recovery mode.
Setting humidity
Setting humidity
Setting humidity
HUMIDITY CONTROL CAN
ONLY BE ACTIVATED BY
THE REMOTE CONTROL
DISCONNECT THE ZERO1
FROM POWER SUPPLY
PRIOR TO ANY MAINTENCE
OPERATIONS.
MAINTENANCE
Maintenance of the Zero1 means regular
cleaning of the ventilator surfaces of
dust and cleaning or replacement of the

ECO VOLT | ZERO1
Operation Instruction For the user and the qualied installer
Clean the impeller blades. To remove
dust use a soft brush, doth or a vacuum
cleaner. Do not use water, abrasive
detergents, solvents, sharp objects. The
impeller blades must be cleaned once
in year. - to the following “Clean the fan
blades, use a soft brush, cloth or vacuum
cleaner. Do not use water, abrasive
detergents, solvents or sharp objects. It
is recommended to clean the fan blades
once a year
It is recommended to do this twice
a year or when required depending
the pull cord, remove the ceramic core
carefully from the ducting. Remove the
-
ver and soft cloth. The Zero1 is equipped
with an alarm sounder to alert the user
alarm can be reset once the cleaning
maintenance has been carried out.
-
ic core back into the ducting and at-
tach the front cover. Regular cleaning
and maintenance will ensure high heat
3 years. Contact your local retailer for

15
ECO VOLT | ZERO1
Operation Instruction For the user and the qualied installer
TROUBLESHOOTING
Table
Fault Possible reasons Fault handling
The fan does not start
during start up
No power supply Make sure the unit is
properly connected
Motor is jammed the
blades are clogged
Turn the unit off and
the blades of the fan
Automatic switch tripping
following the Zero1 being
switched on
Electrical fault inside
the unit Contact your local service
centre
Fan speed set to low Adjust the fan speed
the ceramic core are dirty
cleaning and
maintenance
The Zero1 generates
an alarm sound
cleaning and
maintenance
There is a vibrating
noise coming from
the unit
The fan blades are dirty Clean the fan blades
The unit was installed
incorrectly
are not loose, tighten if
necessary

16 ECO VOLT | ZERO1
Operation Instruction For the user and the qualied installer
STORAGE AND HANDLING
Store the product in it’s original packaging in a dry ventilated store room with tem-
and chemical substances. Handle the product with care and avoid overloading or
heavy objects been placed on the product.
Unit 3B Rosemount Park Drive,
Rosemount Business Park,
Dublin 11, Ireland
Info@ecovolt.ie
www.ecovolt.ie
RETURNS
If you have a faulty product, please return it to the address below. Ecovolt Limited,
Unit 3B, Rosemount Park Drive, Rosemount Business Park, Ballycoolin Dublin 11,
WARRANTY
date of delivery. A full list of terms and conditions associated with the product’s war-
ranty can be found on the manufacturer’s website.
Table of contents