Effekta MKD 1500 RT XL User manual

UPS
Uninterrupted Power Supply
MKD 1500 RT
Operating Manual V. 1.0
Article number: MKD 1500 RT: ACX11MKT1K500000
Translation of the original operating manual

UPS MKD 1500 RT
Legal Notice
MKD series
2
Legal Notice
by EFFEKTA Regeltechnik GmbH
EFFEKTA Regeltechnik GmbH, 78628 Rottweil, retains the copyright to this
documentation.
This documentation is solely intended for the operator and his staff. The con-
tent of this documentation (texts, figures, drawings, graphics, plans, etc.) may
not be copied or distributed in part or in full without our consent in writing, nor
can it be used without authorisation for competitive purposes or given or made
accessible to third parties.
EFFEKTA Regeltechnik GmbH
Rheinwaldstraße 34
D –78628 Rottweil
Phone: + 49 (0) 74 1 / /1 74 51 - 0
Fax: + 49 (0) 74 1 / /1 74 51 - 22
E-mail: ups@effekta.com
Internet: www.effekta.com
Manual: Operating manual
Language: English
Release date: 04/2012
We reserve the right to make changes to the design and the system that
will improve the system, the production process or the product

UPS MKD 1500 RT
Table of Contents
MKD series
3
Table of Contents
1. Introduction............................................................................................................. 5
1.1 Foreword................................................................................................................... 5
1.2 Validity ...................................................................................................................... 6
1.3 Storage ..................................................................................................................... 6
1.4 Symbols in this Manual.............................................................................................. 6
1.5 Information Obligation ..............................................................................................10
1.6 Warranty Conditions.................................................................................................10
1.7 Transport and Storage..............................................................................................12
1.8 Positioning................................................................................................................13
2. Safety Instructions.................................................................................................14
2.1 Introduction ..............................................................................................................14
2.2 Proper Use...............................................................................................................14
2.3 Avoiding Personal Injury / Property Damage ............................................................15
2.4 Protecting the Environment ......................................................................................15
2.5 Connection...............................................................................................................16
2.6 Operation.................................................................................................................17
2.7 Handling Accumulators.............................................................................................17
2.8 Maintenance, Service and Malfunctions ...................................................................18
3. Device Description of UPS.....................................................................................19
3.1 Device Elements on the Front ..................................................................................20
3.2 Device Elements on the Back...................................................................................23
3.3 Device modification..................................................................................................28
4. Storage and Unpacking .........................................................................................37
4.1 Storage of the UPS ..................................................................................................37
4.2 Unpacking the Device...............................................................................................37
5. System Description................................................................................................38
6. Installation and Connection of the UPS................................................................40
6.1 Connection of the UPS.............................................................................................40
6.2 UPS communication connection...............................................................................42
6.3 Connection Sequence..............................................................................................43
7. Device and its Operation........................................................................................46
7.1 Operating the UPS...................................................................................................46
7.2 Operating Manual for the UPS..................................................................................51
7.3 Menu........................................................................................................................55
8. Eliminating Errors..................................................................................................64
9. Software..................................................................................................................67

UPS MKD 1500 RT
Table of Contents
MKD series
4
10. Maintenance and Service......................................................................................68
10.1 Measurement of the Bridging Period (Support Period).............................................68
10.2 Replacing the Accumulators ....................................................................................69
10.3 Service Report.........................................................................................................70
10.4 Service Hotline.........................................................................................................71
10.5 Maintenance and Service Contracts.........................................................................71
11. Technical Data .......................................................................................................72
11.1 Scope of Delivery / (Optional) Accessories ..............................................................73
11.2 Wear Parts List........................................................................................................74
12. Requirements from the Declaration of Conformity..............................................75

UPS MKD 1500 RT
Introduction
MKD series
5
1. Introduction
1.1 Foreword
Dear Operator,
You are about to operate an uninterrupted power supply.
This operating manual should provide you with support for working responsibly
and give you basic information about the uninterrupted power supply, namely
how it operates, its application and what you should do in the event of malfunc-
tioning. Furthermore, this operating manual contains instructions for the trans-
port and storage as well as the handling and installation of the uninterrupted
power supply.
The plan guidelines in this operating manual only relate to special requirements
for the uninterrupted power supply. During installation, make sure you follow
the national and local requirements for electrical installations.
The content of this device description may change due to technological pro-
gress. We have tried to present the content correctly and clearly. If, however,
we have made errors, we would be grateful for information about this.
We are not liable for errors in this operating manual and the resulting conse-
quences.
The uninterrupted power supply is intended to protect sensitive, electrical sys-
tems against interruptions that can occur due to poor power quality or mains
failures.
Please read this operating manual carefully and regard in particular the
safety instructions!
If you have questions about the device, our technical supervisor or our em-
ployees will be glad to help you.
Your
EFFEKTA Regeltechnik GmbH

UPS MKD 1500 RT
Introduction
MKD series
6
1.2 Validity
The descriptions in this operating manual relate solely to the
Uninterrupted Power Supply
defined in the Technical Data
as a whole or they refer to modules, components and individual parts that were
developed and built by EFFEKTA Regeltechnik GmbH.
11. Technical Data
1.3 Storage
This operating manual for the device must be stored in the vicinity of the device
at all times so it is immediately available if need be.
1.4 Symbols in this Manual
The abbreviation UPS in this manual stands for the uninterrupted power sup-
ply.
Read this documentation carefully and make yourself familiar with the
product before using it.
Store this operating manual in an easily accessible place to refer to it if
necessary.
Please pass this operating manual on to later users of the product.
1.4.1 Danger warning levels
Text that is marked with DANGER! provides a warning about dangers. If
accident prevention measures are not taken, these dangers may result in
serious (irreversible) injuries or even death!

UPS MKD 1500 RT
Introduction
MKD series
7
Text that is marked with WARNING! provides a warning about hazards. If
accident prevention measures are not taken, these hazards may result in
serious (irreversible) injuries or even death!
Text that is marked with CAUTION! provides a warning about hazards. If
accident prevention measures are not taken, these dangerous situations
can lead to slight or medium reversible injuries.
Text that is marked with ATTENTION! contains very important instruc-
tions for situations that, if accident prevention measures are not taken,
may result in damage to the product and / or its functions or an object in
its vicinity.
This symbol indicates text that contains important instructions / comments or
tips.

UPS MKD 1500 RT
Introduction
MKD series
8
1.4.2 Warning information
1.4.2.1 Warning about danger spots
General warning about danger spots!
1.4.2.2 Specific warning
Warning about dangerous electrical voltage!
Warning for handling accumulators!
1.4.3 Instruction symbols
Regard the provided documentation and/or instructions!
Disconnect before work!

UPS MKD 1500 RT
Introduction
MKD series
9
1.4.4 General symbols
●
This dot marks descriptions of activities that you should carry out.
–
This dash marks specifications.
This arrow marks a cross reference.
If a cross reference to another chapter is necessary in the text, this is short-
ened for clarity.
Example: OM, 2 Safety Instructions
This means: See chapter 2 Safety Instructions.
If the cross reference refers to a page, figure or position number, this infor-
mation is added at the end of the cross reference.
Example: Fig. 4 - 4, Pos. 1
This means: See position number 1 in figure 4 (in chapter 4
of this manual).
(3)
Numbers in brackets refer to the positions in the figures.
Identifies instructions for recycling.
Identifies components that are subject to the Electronic Scrap Regulation.
Identifies components or parts that must be disposed. Do not throw these in
the household waste.
Requirement that must be fulfilled:
The DC circuit breaker is on "OFF."

UPS MKD 1500 RT
Introduction
MKD series
10
1.5 Information Obligation
This operating manual must be read, understood and all its points regarded by
all persons that are responsible for the
–operation
–cleaning and
–disposal
of the device.
EFFEKTA Regeltechnik GmbH is not liable for damage incurred or caused
by not or insufficiently trained staff!
1.6 Warranty Conditions
The receipt of delivery is considered as the record for the initial purchase and
should be stored in a good place. It will be necessary for making use of the
warranty. If the product is passed on to another user, he has the right to the
warranty for the remainder of the warranty period. The purchase receipt as well
as this declaration should also be given to the new owner if the device is
passed on.
We guarantee that this device, upon delivery, is in a functional state and tech-
nically conforms to the descriptions in the appended documentation.
The warranty period for special devices corresponds to the minimum periods
stipulated by law.
The warranty ceases to apply in the following cases:
In the event of defects from: freight damage, accident, natural catastrophes,
misuse, vandalism, improper use, defective maintenance or incorrect repair by
third parties.
–In the event of changes, unauthorised intervention, incorrect operation, an-
other device or accessories, false installation or other modifications not ap-
proved by us.
–Improper use such as plugging the device into unsuitable energy sources,
attempts to overload the UPS, use in an unsuitable environment, etc.
–In the event of failure to follow instructions in the provided documentation.
–In the event that the product is incompatible due to possible technical inno-
vations or regulations that occur after the purchase.

UPS MKD 1500 RT
Introduction
MKD series
11
–In the event of incompatibility or malfunctioning that was caused by product
components we did not install.
–In the event of developments that are related to the normal aging process
of the product (wear parts).
–In the event of defects that were caused by external fixtures.
The warranty period for replaced and/or repaired parts as part of this warranty
expires together with the original warranty for the product.
Devices that are sent in without accessories are replaced without accessories.
The return of the device is only accepted if this is done in the original packag-
ing.
Incurred transport costs are generally not included in the warranty.
You shall bear the cost of repair and exchange, and the company is not liable
for damage, whether directly, unintentionally, specifically, or for subsequent
damage, even if it was caused by negligence or other errors.
EFFEKTA Regeltechnik GmbH does not provide either explicit or implicit war-
ranties related to this device and its quality, performance, saleability or suitabil-
ity for a certain purpose. In some countries, the exclusion of implicit warranties
is not permitted by law. In this case, the validity of all explicit and implicit war-
ranties is limited to the warranty period. With the expiration of these periods,
all warranties lose their validity. In some countries, a limitation of the validity
period of implicit warranties is not permitted by law so that the aforementioned
limitation does not take effect.

UPS MKD 1500 RT
Introduction
MKD series
12
1.6.1 Limitation of Liability
Claims to damage compensation are excluded unless they involve intent or
gross negligence by EFFEKTA Regeltechnik GmbH or its employees. This
does not affect liability according to the Product Liability Act. Under no circum-
stances are we liable for:
–claims that third parties make against you due to losses or damage.
–loss of or damage to your drawings or data or the costs of recovering this
data.
–economic subsequent damage (including lost profits or savings) or con-
comitant damage, including in the event that we were informed of the pos-
sibility of such damage.
Under no circumstances is EFFEKTA Regeltechnik GmbH responsible for
any accidental, indirect, specific, subsequent or other damage of any kind (in-
cluding, without any limitation, damage related to a loss of profits, interruption
of business, loss of business information, or any other losses) that results from
use of the device or is connected with the device whether it is based on the
contract, damage compensation, negligence, strict liability or other claims,
even if EFFEKTA Regeltechnik GmbH was informed about the possibility of
such damage in advance. This exemption also includes any liability that can
result from the claims of third parties against the initial purchaser.
In some countries, the exemption or the limitation of concomitant or subse-
quent damage is not permitted by law so that the aforementioned declaration
does not enter into force.
1.7 Transport and Storage
The UPS may only be transported to the intended location in the original pack-
aging. The same applies to moves or returns.
The packaging plays no role as fall protection, so all fallen devices must be
checked by EFFEKTA Regeltechnik GmbH before commissioning.
The device may not be transported or stored on its head.

UPS MKD 1500 RT
Introduction
MKD series
13
1.8 Positioning
Do not install in an area in which combustible vapours result e.g. from
petrol tanks, engine compartments, etc.
The UPS is designed for operation in ventilated rooms with a surrounding tem-
perature of 0 ° to 40 °C.
If the UPS is exposed to severe and quick temperature changes, there is dan-
ger of condensation. Before you take additional steps, an acclimatisation pe-
riod of at least 2 hours is to be observed.
Never place or operate the device in a moist environment. Keep liquids away
from the device.
The UPS may not be placed in the vicinity of heat sources.
The UPS can be installed horizontally and vertically. If installed vertically, use
the feet. If installed horizontally, it must be fitted in a 19" rack.
Ensure that the rear side and the front side of the device are at least 10 cm
from other objects for ventilation in order to prevent trapped air and too much
warming. Ensure that the air openings cannot be covered, e.g. through drawn-
in paper, fabric, etc.

UPS MKD 1500 RT
Safety Instructions
MKD series
14
2. Safety Instructions
2.1 Introduction
The UPS is a device produced for uninterrupted power supply in accor-
dance with the technology rules and requirements.
The device and its related components, modules and parts meet indi-
vidually and in their entirety the currently valid safety standards as well
as the standards of the EC Machinery Directive 2006/42/EC.
The device is safe when used properly and under consideration of the
safety requirements and instructions provided in this operating manual.
2.2 Proper Use
The UPS and its related components may only be used for purposes in
accordance with its design - for the short-term supply of electrical de-
vices (230 V AC) that do not exceed the nominal performance in its en-
tirety.
Any other use is considered improper and can lead to personal injury or
damage to the device!
Improper use:
The device is not designed for use
–in explosive,
–dusty,
–radioactive or
–biologically or chemically contaminated atmospheres!
This is class A equipment. This equipment can cause radio interference
in residential areas. In this case, operator may be requested to pursue
appropriate measures!

UPS MKD 1500 RT
Safety Instructions
MKD series
15
2.3 Avoiding Personal Injury / Property Damage
Please read this operating manual carefully to familiarise yourself with the
device.
In particular, heed the information regarding the installation and commis-
sioning of the device.
Only operate the product in an appropriate and proper way and within the
parameters stated in the Technical Data.
Only perform maintenance and service work that is described in the docu-
mentation. Observe the required steps. Only use original replacement parts
from EFFEKTA Regeltechnik GmbH.
2.4 Protecting the Environment
Send the product back to EFFEKTA Regeltechnik GmbH after the end of
its use. We will ensure environmentally friendly disposal.

UPS MKD 1500 RT
Safety Instructions
MKD series
16
2.5 Connection
Only connect the UPS to an earthed electric safety socket or be sure to
connect it to the protective conductor in the event of a connecting termi-
nal. Under no circumstances may the device may be operated without a
protective conductor.
The socket for home installation must be easily accessible and in the
vicinity of the UPS. Be sure to have the shortest possible cable lengths
for fixed connections.
When operating with a generator, you must ensure the correct polarity of
the connection for the UPS.
To connect the UPS to the socket of the home installation, only use a
VDE tested and CE labelled mains cable. For a fixed connection, an ap-
propriate cable is to be used.
To connect the loads to the UPS, only use a VDE-tested and CE-labelled
cable. For a permanent connection of the loads, an appropriate cable is to
be used.
The protection of the loads must always take place directly on a load,
never centrally at the UPS.
Do not operate any household or craftsman tools such as fan heaters,
vacuum cleaners, drills, hair dryers, toasters, etc. with the UPS.
Do not connect any loads to the UPS, which could overload the device
(e.g. laser printer).
The total earth leakage currents of all the loads connected to the UPS
may not exceed 3.5 mA.
Keep cables as short as possible and always lay them correctly. Dangers
such as stumbling, squeezing, clipping, etc. are to be avoided with the
cables.
To connect the loads to the UPS, only use a VDE-tested and CE-labelled
power cables with the appropriate cable diameter. The protection of the loads
must always take place directly on a load, never centrally at the UPS. Do not
connect any loads to the UPS, which could overload the device (regard the
high starting currents).

UPS MKD 1500 RT
Safety Instructions
MKD series
17
2.6 Operation
Before the loads are connected on the output, the basic configuration must be
set. The output voltage in relation to the loads is very important.
The UPS system includes energy storage (accumulators). As a result, the out-
put can carry power even if the UPS is not connected on the mains input side.
To completely switch off the UPS, disconnect the mains connector and then
press the "OFF" key for more than 3 seconds, wait until the UPS is switched off
and then disconnect the mains connection (remove the mains power cable
from the device). Make sure that no liquids or foreign bodies enter the UPS. To
protect the UPS, you should avoid a constant load at the output of over 80 %.
The display of the output load is only to be viewed as a reference value. To de-
termine the exact output load, separate measurements are required.
2.7 Handling Accumulators
Attention –Danger of electric shocks and burns.
Accumulators can cause electric shocks and produce high short circuit
currents that can in turn lead to burns.
Unauthorised staff are to stay away from accumulators.
Do not bring accumulators into contact with heat sources or throw them
in the fire. There is an explosion danger!
Do not open or destroy accumulators. The released electrolyte is very
dangerous for people and the environment (searing danger for skin and
eyes, poisonous).

UPS MKD 1500 RT
Safety Instructions
MKD series
18
Defective accumulators must be disposed in an environmentally
friendly way.
Do not throw accumulators in household trash under any circumstances.
Local disposal requirements are to be regarded.
2.8 Maintenance, Service and Malfunctions
Attention –Danger of electric shocks.
Even after switching off the device with the power switch or disconnect-
ing the battery supply, parts of the UPS can produce high voltage.
Work on accumulators is only to be conducted and monitored by staff
with appropriate knowledge of the required safety rules.
Unauthorised staff are to be kept away from accumulators.
When working on the UPS and the accumulators, the following precau-
tions are to be taken:
–Wristwatches, rings and other metal objects are to be removed,
–Only use tools insulated in accordance with electrotechnical rules.
–Wear protective gear (safety glasses, gloves, face mask, etc.),
–The UPS may not be disassembled.

UPS MKD 1500 RT
Device Description of UPS
MKD series
19
3. Device Description of UPS
This manual is intended to provide basic information about single-phase offline
UPS systems, namely how they function, the application of different functions
and what you should do in the event of malfunctioning.
Furthermore, this manual contains instructions for the transport and storage as
well as the handling and installation of the UPS system.
The plan guidelines in this manual only relate to special requirements for the
UPS systems. During installation, make sure you follow the national and local
requirements for electrical installations.
The content of this device description may change due to technological pro-
gress. We have tried to present the content correctly and clearly. If, however,
we have made errors, we would be grateful for information about this.
We are not liable for errors in this description and the resulting consequences.
The UPS system (uninterrupted power supply system) is intended to protect
sensitive, electrical systems such as computers, work stations, electronic cash
registers, critical instruments for operation, telecommunication systems, proc-
ess controls, etc. against interruptions that can occur due to poor power quality
or mains failures. Sensitive systems of this kind require complete protection
against electrical disturbances. These may involve external disturbances (such
as thunderstorms, operational disturbances) or disturbances from adjacent de-
vices (such as engines, air conditioners, processing machines, welding equip-
ment, etc.).
The mains disturbances can be summarised as follows:
–quick and slow mains voltage peaks, fluctuations;
–mains failure;
–quick and slow frequency peaks, fluctuations;
–mains interference or transients
The UPS system monitors the aforementioned mains parameters and protects
the connected loads by taking appropriate countermeasures (e.g. switching to
support operation in the event of temporary over- or under-voltage in the mains
in order to protect the end devices).
The device can be modified with ease. You have the option of installing the
UPS upright using the feet or alternatively it can be installed horizontally in a
19" rack.
Please note chapter (3.3 Device modification) which describes the modifi-
cation process.

UPS MKD 1500 RT
Device Description of UPS
MKD series
20
3.1 Device Elements on the Front
The front of the device contains all the operating and display elements required
for normal operation.
1 LCD
2 "Selection" key
3 "Menu down / Next" key
4 "Menu up / Back" key
5 "ON / OFF" key
Fig. 3-1 - 1 Front view of MKD 1500 RT
Table of contents
Other Effekta Power Supply manuals
Popular Power Supply manuals by other brands

GMI
GMI D6011S instruction manual

C-TEC
C-TEC BF362-5 installation instructions

Brooks Instrument
Brooks Instrument 0250 Series quick start guide

Integrated Power Designs
Integrated Power Designs REL-185 Series operating instructions

Novus
Novus FTR instruction manual

multicomp pro
multicomp pro MP710086 manual