Eizo CID1300P User manual

Instructions for Use
CID1300P
Panel PC with Touchscreen and Software
Important
Please read the safety information and all information delivered
with the product carefully to familiarize yourself with safe and
effective usage.

EIZO GmbH
Carl-Benz-Straße 3
76761 Rülzheim
Germany
1086250-002
02/2023 Technical data subject to change.
Copyright © EIZO GmbH 2023.
All rights reserved.
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to
prevent damage to property. The notices referring to your personal safety are highlighted in the manual
by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These
notices shown below are graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that material damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of
danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a
warning relating to property damage.
Qualified personnel
The product/system described in this documentation may be operated only by personnel qualified for
the specific task in accordance with the relevant documentation, in particular its warning notices and
safety instructions. Qualified personnel are those who, based on their training and experience, are ca-
pable of identifying risks and avoiding potential hazards when working with these products/systems.
Use of EIZO products
WARNING
EIZO products may only be used for the applications described in the catalog and in the relevant tech-
nical documentation. If products and components from other manufacturers are used, these must be
recommended or approved by EIZO. Proper transport, storage, installation, assembly, commissioning,
operation and maintenance are required to ensure that the products operate safely and without any
problems. The permissible ambient conditions must be complied with. The information in the relevant
documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of their respective owners. Please refer to the
trademarks listed in the appendix. The remaining trademarks in this publication may be trademarks
whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of liability
We have reviewed the contents of this publication to ensure consistency with the hardware and soft-
ware described. Since variance cannot be precluded entirely, we cannot guarantee full consistency.
However, the information in this publication is reviewed regularly and any necessary corrections are in-
cluded in subsequent editions.

Table of contents
CID1300P
Instructions for Use, 02/2023 3
Table of contents
Legal information ............................................................................................................. 2
1 Introduction....................................................................................................................... 5
1.1 Contents of this document ........................................................................................5
1.2 Intended use .............................................................................................................5
2 Safety information ............................................................................................................ 6
2.1 General safety instructions .......................................................................................6
2.2 Product-specific safety instructions ..........................................................................9
3 Description...................................................................................................................... 10
3.1 Scope of delivery ....................................................................................................10
3.2 Features..................................................................................................................11
4 Setup and installation .................................................................................................... 12
4.1 Installation site ........................................................................................................12
4.2 Installation in a VESA holder ..................................................................................13
5 Connecting...................................................................................................................... 14
5.1 Safety information for connection ...........................................................................14
5.2 Device connectors ..................................................................................................15
5.3 Connecting to the IT network..................................................................................16
5.4 Connecting the keyboard........................................................................................16
5.5 Connecting the power supply and switching on......................................................17
6 Commissioning............................................................................................................... 18
6.1 Introduction .............................................................................................................18
6.2 Setup procedure .....................................................................................................18
6.3 Changing the network settings of the CID 1300P...................................................20
6.4 Entering the target address for access via the “Web Based Interface” ..................20
6.5 Entering the IP address for access via “LMM Control” ...........................................22
6.6 Changing the application for access to the LMM....................................................23
6.7 Logging on as admin ..............................................................................................23
7 Operation......................................................................................................................... 24
7.1 Switching on / off ....................................................................................................24
7.2 Touchscreen ...........................................................................................................24
8 Cleaning and disinfecting.............................................................................................. 26
8.1 Recommended cleaning agents and disinfectants .................................................26
9 Troubleshooting ............................................................................................................. 27
10 Technical specifications ................................................................................................ 28
10.1 Dimension drawing .................................................................................................28

Table of contents
4
CID1300P
Instructions for Use, 02/2023
10.2 Panel PC.................................................................................................................28
10.3 Components ...........................................................................................................28
10.4 Power supply ..........................................................................................................29
10.5 Inputs / outputs .......................................................................................................29
10.6 Certificates, approvals, and standards ...................................................................29
10.7 Electromagnetic compatibility (EN60601-1-2) ........................................................30
11 Appendix ......................................................................................................................... 31
11.1 Guidelines and manufacturer's declaration – electromagnetic emissions ..............31
11.2 Warranty .................................................................................................................31
11.3 Repairs ...................................................................................................................31
11.4 Environmental protection ........................................................................................31
11.5 Additional devices...................................................................................................31
11.6 Contact ...................................................................................................................31
11.7 Manufacturer's information .....................................................................................31
11.8 Trademarks.............................................................................................................32
Index ................................................................................................................................ 33

Introduction
1.1 Contents of this document
CID1300P
Instructions for Use, 02/2023 5
1 Introduction
1.1 Contents of this document
Note
This documentation is available in electronic format only. It can be found on the CD-ROM
provided and can be downloaded from www.eizo-or.com.
This document explains the functionality and the intended use of the Panel PC CID1300P.
To ensure clarity, it does not contain all detailed information on this product.
You are additionally advised that the contents of this document are neither part of a previ-
ous or existing agreement, commitment, or legal relationship, nor does it modify such.
1.2 Intended use
The CID1300P is a panel PC with touchscreen and appropriate software, and is used as an
interface to select and switch among various predefined layouts in the EIZO video manage-
ment system, which are then displayed on the corresponding monitors.
The Large Monitor Manager (LMM) system for example is an EIZO video management sys-
tem.
The CID1300P is intended for use by health care professionals in the patient vicinity in the
OR or other sterile, medical environment. It is not however intended for direct contact with a
patient.
The CID1300P is intended to be installed on a suitable VESA mount.
The CID1300P is not delivered with medical application software and is therefore not in-
tended for diagnostic usage or patient monitoring.

Safety information
2.1 General safety instructions
6
CID1300P
Instructions for Use, 02/2023
2 Safety information
2.1 General safety instructions
Correct and safe operation of EIZO devices requires professional transport, storage, instal-
lation, and connection, as well as careful operation and servicing.
The devices may only be used for applications for which they are intended.
For safety reasons, the following precautions must be observed:
DANGER
Please observe all warning information on the device and in the instructions for use
There is a danger to life if warnings are not observed. Severe personal injury or damage to property
may occur.
Observe the safety requirements of EN 60601–1 (IEC 60601–1)
To prevent injury to patients and users, design the electrical system in accordance with the safety re-
quirements of EN60601‑1 (IEC60601‑1) for “Safety requirements for medical electrical systems”.
Connecting the protective ground conductor
If the device is connected to the line power, the device must be connected to a protective ground
conductor. This is the only way to ensure that the contact leakage current in a first fault event does
not exceed 500µA.
The interruption of the device's protective conductor is considered a first fault event in accordance
with EN 60601- 1.
Use the following measures to ensure that the leakage currents remain below the specified limits:
• Switch-disconnectors for signal input unit or signal output unit
• Use of a safety isolating transformer
• Use of the additional protective ground terminal
Mounting of the monitor: The monitor's suspension arm must have its own protective ground conduc-
tor. This protective ground conductor guarantees, together with the protective ground conductor of
the monitor, that the housing leakage current always remains less than 500µA, even in the event of
a single fault condition (i.e. when the first fault event occurs).
No unauthorized opening of the device / no unauthorized service or maintenance work
The device may only be opened by qualified personnel. Likewise, service or maintenance work may
only be carried out by qualified personnel. There is a risk of electric shock.
No liability is accepted for death and injury to persons or damage to property resulting from work car-
ried out by non-qualified personnel.
Do not touch components in the device
If the device is connected to the line power, components in the device are subjected to high voltages.
Touching the components may be fatal.
No contact between device and patients
The device is not suitable for direct contact with a patient. The device and patient must never be
touched simultaneously. Otherwise there is a danger to life and limb.

Safety information
2.1 General safety instructions
CID1300P
Instructions for Use, 02/2023 7
DANGER
Please observe all warning information on the device and in the instructions for use
There is a danger to life if warnings are not observed. Severe personal injury or damage to property
may occur.
Never use defective power cables
If a damaged or unsuitable power cable is used, it could result in a fire or electric shock. Only use
power cables with PE contacts approved by the manufacturer.
Disconnect the power cable correctly
When disconnecting the power cable, always do so by holding the plug. Ensure that your hands are
dry. There is a risk of electric shock.
Do not insert any objects into the housing
Objects inserted into the housing may result in an electric shock or damage to the device.
Do not place any objects on top of the device
If you place objects on top of the device, this can lead to overheating and fire.
Avoid penetration of liquid
Liquids seeping into the device may result in electric shock or device failure.
CAUTION
Extensive damage to property may result if the device is not connected correctly
That is why you should observe the warning information:
Connection must be carried out by specialists
Please ensure that all steps are taken to avoid injuries or incorrect diagnoses.
• Only use the video cables specified by the manufacturer for the connection.
• Only use power cables with PE contacts.
• Only use power outlets with PE contacts.
• Do not connect too many devices to a power outlet or extension cable.
• Observe the information provided by the respective manufacturer.
• If required by the application or local regulations, QA software must be used for quality control
and documentation.
Connection in the USA and Canada
Molded power plugs must comply with the requirements for “hospital grade attachments” CSA Std.
C22.2 No.21 and UL498.
Connection in China
Only use power cables approved for China. These power cables are identified by the labels “CCC” or
“CQC”.
Observe the country-specific regulations
Observe all regulations of the country in which the device is used.

Safety information
2.1 General safety instructions
8
CID1300P
Instructions for Use, 02/2023
CAUTION
Extensive damage to property may result if the device is not connected correctly
That is why you should observe the warning information:
• Desktop installation:
Place the device on a solid and level surface. The installation surface must be suitable for the
weight of the device.
• For attaching to a wall or ceiling mount:
The mount unit must be suitable for the weight of the device.
• For installation in a rack:
Observe the installation sequence, and provide ventilation for the device.
Provide adequate air circulation
When installing the device, ensure that there is adequate air circulation for operation. The permissi-
ble ambient temperature range must not be violated. Otherwise, the device could be destroyed by
overheating.
Avoid sources of heat
Do not install the device in the vicinity of sources of heat, such as radiators, heating appliances or
other devices that can generate or emit heat.
Do not subject the device to jolting or shocks
The device contains sensitive electronic components that could be damaged by jolting or shocks.
Only switch on a cold device following adaptation to room temperature
If the device is brought into a room with a higher or rising temperature, condensed water will form in
and on the device. Do not switch on the device until the condensed water has evaporated. Other-
wise, the device could be damaged.

Safety information
2.2 Product-specific safety instructions
CID1300P
Instructions for Use, 02/2023 9
CAUTION
Extensive damage to property may result if the device is not connected correctly
That is why you should observe the warning information:
Transportation only in original packaging
Use the original packaging for transportation, and transport in the correct shipping position. Be sure
in particular to protect the monitor LCD modules from shocks.
Care of device / cleaning agents
• Remove water drops immediately; extended contact with water discolors the surface.
• Only clean the surfaces using the cleaning agents referred to in the instructions for use provided
by the manufacturer.
• Monitor: The screen is extremely sensitive to mechanical damage. Absolutely avoid scratches,
shocks, etc.
What to do if the device is faulty
If the following conditions exist, the device must be disconnected from the line power and checked
by qualified personnel:
• Damage to the plug or power cable.
• After liquid seeps into the device.
• If the device has been exposed to moisture.
• If the device does not function or if a fault cannot be eliminated using the Instructions for Use.
• If the device has been dropped and/or the housing damaged.
• If the device smells of burning or makes peculiar noises.
Be aware of the monitors aging
Note that monitors can fail as a result of aging, and that image properties such as brightness, con-
trast, and color value can change.
2.2 Product-specific safety instructions
NOTICE
Network security
The CID1300P has been secured with a BIOS password, blocked network ports, and other
security measures. Nevertheless, the CID1300P is based on standard computer and net-
work technology.
• Make sure the network environment is secure.
• Follow the information in 60601-1, Chap. 16, ME Systems.
Note
Follow the safety information in the instructions for use on the CD from the device manu-
facturer.

Description
3.1 Scope of delivery
10
CID1300P
Instructions for Use, 02/2023
3 Description
3.1 Scope of delivery
The CID1300P is a panel PC with touchscreen and tailored application software. The scope
of delivery consists of the device and supplementary items.
Device
Product Order number Description
Panel PC CID1300P 6GF65500AE180AA4 Panel PC with touchscreen and application
software, version ADLINK MLC-133-AL
Supplementary items
• Power supply unit
• Documentation and software CD
Note
Further information on the ADLINK MLC-133-AL is available in the instructions for use pro-
vided by the panel PC manufacturer on the supplied documentation CD.

Description
3.2 Features
CID1300P
Instructions for Use, 02/2023 11
3.2 Features
Easy to operate
The higher resolution and improved touch responsiveness of modern panel PCs provides
the new CID1300P with fast and intuitive selection of video sources directly through the view
management of the LMM or via “LMM Control”.
Integrates easily into the video management system network
The introduction of simple input screens means that only basic IT administrator knowledge
is required. The installation effort is reduced to two steps: incorporation into the local net-
work and entry of the video management system's IP address.
Additional security measures integrated into the application
With security measures such as service passwords, blocked network ports, and restricted
system access, the CID1300P application is designed for robust and secure use in the OR
environment.

Setup and installation
4.1 Installation site
12
CID1300P
Instructions for Use, 02/2023
4 Setup and installation
CAUTION
Changes to device
Do not make any mechanical or electric changes to the device. Otherwise the device war-
ranty becomes invalid.
The manufacturer is not liable for changes made to the device.
4.1 Installation site
Note the following conditions at the installation site. Observe the manufacturer’s panel PC
instructions for use and related information regarding the installation site.
NOTICE
Device connections accessible at all times
The power supply connector of the CID1300P is the only way to fully disconnect the panel
PC from the power network.
• The power supply connection or the cable to the external power supply unit has to be
installed such that it is accessible to the user at all times.
• If this is not possible, a separator accessible to the user must be designed and installed
in accordance with applicable safety standards.
NOTICE
Condensation
If the device is brought into a warm environment from a cold one, condensation may form
in the device. This could result in a short circuit when switching on the device, damaging it.
• Wait until the condensed water has evaporated, including that inside the device, before
you switch it on. This can take several hours.
NOTICE
Permissible ambient temperature
To ensure proper and safe operation of the device, the ambient temperature must remain
within the permissible ambient temperature range.
• Observe the information from the panel PC manufacturer.
Avoid dusty environments
The CID1300P is intended for use in the clean environments of medical technology.
• Protect the panel PC from dust, for example through appropriate construction measures
at the installation site.
• During transport, use the original packaging.

Setup and installation
4.2 Installation in a VESA holder
CID1300P
Instructions for Use, 02/2023 13
Avoid reflections on the screen
The CID1300P panel PC has a touchscreen that is only effective if the screen is clean and
grease-free.
• Comply with the specifications for Cleaning [}26].
• Position the CID1300P to avoid reflections on the screen surface. Reflections can be
caused by lights, windows, furniture with shiny surfaces, or light-colored walls.
• Use only non-dazzling reflector bulbs for the ceiling lighting.
Avoid shocks and impacts
The CID1300P is sensitive to shock. Shocks and impacts on the panel surface can lead to
total failure.
• Ensure that such mechanical influences are avoided.
Movable installation
If the CID1300P is installed such that it can move, make sure that persons or objects in the
facility are not endangered by the range of movement of the CID1300P.
4.2 Installation in a VESA holder
The Panel PC is installed such that the main interfaces point downward.
NOTICE
Follow the installation information in the instructions for use for the device.

Connecting
5.1 Safety information for connection
14
CID1300P
Instructions for Use, 02/2023
5 Connecting
5.1 Safety information for connection
Observe all safety information and warnings for the device to ensure danger-free operation.
Note
Follow the connection information in the panel PC manufacturer’s instructions for use.
CAUTION
Shielding measures
Follow all shielding measures in accordance with local EMC directives. If these guidelines
are not observed, device malfunction may result.
CAUTION
Excessive currents, short circuits, and ground faults
In accordance with national standards and regulations, protection against excessive cur-
rents, short circuits, and ground faults must be incorporated into the building installation.
NOTICE
Cable installation
Observe the following instructions:
• Only shielded cables are to be used for all signal connections.
• If the relevant facility is available on the connector, all plug connections must be
screwed tight or locked.
• The connecting cables must not be kinked.
• The minimum bending radius of a connecting cable generally equals five times the ca-
ble diameter.
• Do not route signal cables and power cables next to one another. Otherwise, line power
subject to heavy interference could result in reversible pixel errors.
• The device must not share a line power supply with motors or valves (interference!).
• Externally connected cables can represent a trip hazard. Make sure that all incoming
cables are safely routed.
• If the device offers strain relief mechanisms for the cables, use them to prevent unin-
tended loosening of connected cables.

Connecting
5.2 Device connectors
CID1300P
Instructions for Use, 02/2023 15
5.2 Device connectors
Overview
1. On/off switch
2. Audio
3. Equipotential bonding connection (stud with 6 mm diameter to connect an equipotential
bonding cable)
4. HDMI connector (unused)
5. USB 5 Gbps connector (blue)
6. USB 2.0 connector
7. COM interface
8. IT network connector (RJ45)
9. Power supply connector
Use
The following device connectors are required for use of the CID1300P:
• IT network connector (RJ45)
• USB ports
• Power supply connector
• On/off switch
IT network connector (RJ45)
The RJ45 connector is required to connect the CID1300P to the IT network of the video
management system.
USB ports
A USB port can be used to connect a keyboard when configuring the CID1300P.
An additional USB port can be used to connect a mouse or install updates and patches.

Connecting
5.3 Connecting to the IT network
16
CID1300P
Instructions for Use, 02/2023
Power supply connector
The voltage input of the CID1300P is required for the power supply using an external power
supply unit.
On/off switch
The device can be switched on/off with the on/off switch. When doing so, please note that
the power supply unit remains energized in standby mode and the device is not fully discon-
nected from line power.
5.3 Connecting to the IT network
Using an Ethernet cable, connect the RJ45 connector of the CID1300P, to the video man-
agement system’s IT network.
5.4 Connecting the keyboard
A keyboard is required to configure the CID1300P. Use one of the available USB ports to
connect the keyboard.
Note
US keyboard layout (QWERTY)
Every keyboard connected to the CID1300P is interpreted as having a US keyboard layout
(QWERTY).
• If you are not using a keyboard with a US keyboard layout, use the following layout dia-
gram to locate the keys accordingly:
• Alternatively, you can switch the keyboard mapping in the Windows operating system of
the Panel PC .

Connecting
5.5 Connecting the power supply and switching on
CID1300P
Instructions for Use, 02/2023 17
5.5 Connecting the power supply and switching on
NOTICE
Validated external power supply unit
Only power supply units validated by the manufacturer or EIZO, such as the one provided
with the device, may be used.
Note
• EIZO recommends not connecting the power supply until all other connections have
been made.
• Connect the power plug of the external power supply unit to the voltage input of the
CID1300P.
Note: Implement appropriate safeguards to prevent unintended disconnection from the
power supply.
• Connect the power supply unit to the line power.
Note: Use a power cable approved in your country for this purpose.
• Deactivate the power supply switch-disconnector if one is installed.
• For devices with an on/off switch only: Switch on the CID1300P.
Note: If the device is not working properly, check the system for incorrect connection or
operation before contacting Service.

Commissioning
6.1 Introduction
18
CID1300P
Instructions for Use, 02/2023
6 Commissioning
6.1 Introduction
The CID1300P has the following features:
• The CID1300P is supplied with a pre-installed operating system that is automatically acti-
vated when the device is started up for the first time.
• The CID1300P can be operated with the following LMM variants:
– LMM56800 (article no.: 6GF60203AB031AA0 or 6GF60203AB03)
– LMM0801 (article no.: 6GF60301AA00)
– LMM0802 (article no.: 6GF60301AB00)
– LMM0802-HDM (article no.: 6GF60301AC00)
– LMM0804 (article no.: 6GF60301AB10)
• The "LMM Control" and the "WEB Based Interface" are available to access the
CID1300P on the LMM.
Note
LMM Control
The LMM Control software is supported by the following LMM systems:
• LMM0802-HDM
• LMM0802 with the firmware 4.0.0-Extended or 4.1.0 or higher
• LMM0804 with the firmware 4.0.0-Extended or higher
6.2 Setup procedure
For the CID1300P to be used with the EIZO video management system, it has to be config-
ured for access to the LMM and the appropriate network environment.
Prerequisite
• The CID1300P is connected to the line power.
• The CID1300P is connected to the IT network.
• A Connecting the keyboard [}16] is connected to the USB input of the CID1300P.
• We recommend connecting a mouse to the second USB input of the CID1300P.

Commissioning
6.2 Setup procedure
CID1300P
Instructions for Use, 02/2023 19
Procedure
1. Switch on the CID1300P at the on/off switch.
2. When starting the CID1300P for the first time: Wait a few minutes while Windows installs
with several reboots in between until the dialog “Setup” appears to select “Web Based” or
“LMM Control”.
CAUTION: The power supply may not be interrupted during installation. Under no cir-
cumstances should you switch off the device, as it may otherwise be damaged.
ðWindows is installed and you are logged on as “Admin” to the CID1300P. The
“Setup” dialog is displayed.
3. DHCP is pre-configured for the network settings of the CID1300P. If you opt to use a
static network address, you must Changing the network settings of the CID 1300P
[}20].
ðThe CID1300P is available on the IT network.
4. To access the LMM via the “Web Based Interface”, select “Web Based” in the “Setup” di-
alog and click “OK”. To access the LMM via “LMM Control”, go to Step 6.
ðThe CID1300P is restarted. Once the boot process is complete, the entry dialog for
the target address is displayed.
5. Enter the Entering the target address for access via the “Web Based Interface” [}20]
and click “OK”.
ðThe setup for access via the “Web Based Interface” is completed. You are logged on
as an “EIZO” standard user to the CID1300P.
6. To access the LMM via the “LMM Control”, select “LMM Control” in the “Setup” dialog.
ðThe CID1300P is restarted and the entry dialog for the IP address is displayed once
the boot process is complete.
7. Enter the Entering the IP address for access via “LMM Control” [}22] and click “OK”:
ðThe setup for access via “LMM Control” is completed. You are logged on as an
“EIZO” standard user to the CID1300P.
ðOnce the setup is completed, access to the LMM is configured and takes place automat-
ically whenever the CID1300P is rebooted.
Note
Tips
• To restart the “WEB Based Interface” or “LMM Control”, select <Alt><F4> on the key-
board.
• You can Changing the application for access to the LMM [}23].
• The password for the standard user “EIZO” is “egd_12345”.

Commissioning
6.3 Changing the network settings of the CID 1300P
20
CID1300P
Instructions for Use, 02/2023
6.3 Changing the network settings of the CID 1300P
The CID1300P is pre-configured to obtain its IP address from a DHCP server. To assign a
static IP address to the CID1300P, proceed as follows.
Prerequisite
• A keyboard is connected to the USB input of the CID1300P.
• We recommend connecting a mouse to the second USB input of the CID1300P.
• You are logged on to CID1300P as Admin [}23].
Procedure
1. Open the Windows setting dialog for “Network and Internet”.
2. Double click on “Change adapter options”.
3. Double click on “Ethernet” and enter the static IPv4 address in “Properties”.
Note: Ensure that the network address uses the same network prefix and subnet as the
LMM, for example, 169.254.213.xxx.
4. Close the dialog window.
5. Restart the computer to accept the changes.
Note: If you switch off the system, you may lose the settings.
ðThe static IP address for the CID1300P is set up.
6.4 Entering the target address for access via the “Web Based
Interface”
The target address of the Large Monitor Manager (LMM) to be operated must be entered in
the CID1300P.
Note
Network address
Ensure that the network address set in the CID1300P uses the same network prefix and
subnet as the LMM, for example, 169.254.213.xxx.
Note
LMM user interface
LMM0802, LMM0802-HDM or LMM0804 can be operated using the standard interface or
the View Management. In addition to layout selection, the View Management also allows
image sources to be assigned.
Additional information is available in the LMM instructions for use.
Table of contents