Elan MULTI-PARCAN-54x3W-RGBW User manual

MULTI-PARCAN-54x3W-RGBW
User’s Manual
Thank you for using our LED PAR light 54x3W RGBW, for your safety, please
read the user`s manual carefully before your operation.
Note: This manual includes the important information of installation, operation,

safety instruction. Please install and operate as requested in the manual,
meanwhile, please keep the manual for any unexpected requirment
I. Preface
This Manual includes the important information of installation and operation. Please install and operate the light
accordingtotheinstructions strictly.Anditmustbepoweroffwhenopenthelightor before repair.
Pleaseread thecompletecontentsofthismanual(pleasekeepthismanualattachwiththelightforanypreview)
Inordertomakesurethecorrectandsafetyinstallation、operationandmaintenance, well know andfollowto the
instructionsofManual isnecessary.
Wewillnottakeanyresponsibilitytothelightdamage、propertylossor bodyinjurewhichcausedbytheincorrect
installation、operationandmaintenance.
Notice:
The data which inside the Manual maybe changed due to the continuous improvement, and we’ll not make
another notice.Wewillkeeptherighttoanyspecificationupdateduring improvement
Waring:thelightshouldkeepawayfromfire andwatertoavoid itget intolight.
Packing Content
OneLEDPAR54x3W RGBW
OneDMXcable
Usermanual
Note: Please check if all the contents are completed after unpacking, then, check if the light is
undamaged.
Safety specifications
Thisdeviceforindooruseonly,the protectiongradeis: IP20
Installing of the light must keep a distance with any flammable objects by 5m at least. The distance between the
light and theprojectedobjectsmustbenolessthan1m.
Pleasenever directlyinstallthelightonthesurfaceof theflammableobjects.
The installation、operation and maintenance must be managed bythe qualified professional, and make sure to
operateitunder the instructionoftheManual.
Makesuretheworkenvironmenttemperatureof thelightmaximum 35℃,andminimum -20℃
Thetemperatureofthelightsurfacewillupto60℃evenunderthenormalcooling,sonevertouch itbyhand.
The light was designed by electric shock protection type, and must connect to the power supply system which
well earthed. Furthermore, the ground wire of the light must connect to the ground wire of the power supply
system,ground wireinterface ofthe lightmustwellconnectwiththelight body(or lightmustbewellearthed)
Pleasecheck ifthe voltage isinaccordancewiththeratedpowerbeforeinstalling.
Please never use the power cable which was damaged the insulation cover, meanwhile, never put the power
cableon anyother wire.Pleasepulloutthepower cable byhandle theplugwhenlight is stopworkingor cleaning,
never pulloutitroughlyorhandlethewiredirectly.
The light doesn’t include any spare parts for repairing , please check if all the parts are well installed and screws
are drove tightly before operating. It’s prohibited to use the lightwhenthecover isopened.
Notice: Please make sure it is power off before any installation, repair and clean

II.Technology Parameter
ControlChannels:8DMXChannels
BeamAngel:25°
Control Mode:AUTO, Master/Slave,DMX512,SoundActive
WorkingEnvironment:Indoor,-20℃-40℃
Mixing Color:RGBW mixingcolor
IPGrade:IP20
PowerSupply:AC 100-240V/50-60Hz
LED Unites:54pcsx 3W (RGBW)
Powerconsumption:150W
Packingsize:25×25×36cm 79×52×38.5cm(6pcs/CTN)
N/W:2.9KG(1pc/CTN)G/W:;19KG(6pc/CTN)
III. Connection of power/wire/signal
The exclusive plug should be used between the connection of light and power. Pls check if the rated voltage and
frequency is in accordance with the power supply. In order to make sure the power cable work in the safety
environment. Iffoundthepowercableis overheat,pleasecut off thepower andreduce the parallelconnection quantity
of lights,The lightpowersupplyisAC100~AC240V/50~60Hz
Make sure installation position is steady before fix the light. Professional clamp should be used when the light is
reverse hanging, and drive the clamp into the screw hole which in the bracket of the light. Makesure the light will not
fallfrom thetruss, usethesafetycable gothroughthe trussandbracketofthe lightas asupporting,toavoid thelightto
fall down. There is no entrance to the work area during mounting. Periodically to check if the safetycable has fretted
awayorclampis loosen.Wewillnottakeanyresponsibilitywhich causedbythelightingfallof unsteadyhanging.
Warning:
It is prohibited to move the light by handle the clamp, please move the light by handle
IV. Features:
There are 4 buttons and 4 bit digital LED on the panel, you can choose diffirent working mode via press the
buttons, andit willbedisplayonethedigitalled
Thefanrunningis automaticalcontrolledbytemperature,whenthetemperatureishigherthan60℃,thefan will
run,whenthetemperature is lowerthan55℃, the fan will stoprunning.
V.Description

Mode Up Down Enter
A. Buttonspecifications
1>.Button“Mode”,change theoperatemode
2>.Button“Up”,changethe operatemodeof submenu or addthe value
3>.Button“Down”,changethe operatemode ofsubmenuorsubtractthevalue
4>.Button“Enter”, for confirmation
B.“DMXADD”setting
Press buttonModeto d.XXX,XXXisthevalueofADD001-512,it’stheADDcodeofthislight,press “Up”, “Down”to
adjustit(range:001-512),save automaticallyaftersetting.
C.Work “Mode”setting
The lightincludes 5kinds ofworkmodes,thedefaultmodeisd.001,pressbutton“Mode”,it’s available to chosein
DMXmode,Automode,Editmode,Slavemode, Load the defaultmode.
Display
1>.Displayd.XXX(XXXis001-512ADDcode),DMXmode,canreceivestandardDMXsignal, pressbutton“Up”or
“Down”tochangetheADDcode, andsaveautomaticallyaftersetting.
2>.Display”Auto”,masterunder“Auto”mode,it’savailableto enterinto“Auto”modeselectionbypress button“Enter”,
atthismoment,display“AT.XX”, “XX”iscode01-11,whichmeans11kindsofdynamicandstaticmode,it’savailableto
recyclechoseoneofthemode bypressingbutton“Up”or“Down”.
Display“Edit”,undermaster editingmode,it’s availableto enterinto “Edit”modeselection bypressingbutton“Enter”,
atthismoment,display“Pr.0X”, “X”iscode1-5, whichmeansinternal5kindsofselectablemode,;it’savailableto
recyclechoseoneofthemode bypressingbutton“Up”or“Down”.Pressbutton“Enter”underanmode,it’savailable
torecyclechange thebrightness ofRGBLED.
3>.Display“Slav”,slavemode,receivethesynchronous datafrommaster.
4>.Display“Load”,pressbutton “Enter”,toload thedefault data.
VI. Operation

VII. DMX Channel Form

1st light
台
灯
2nd light
3rd light
Resistor
IN
OUT
IN
OUT
IN
OUT
120Ω1W
DMX Channel
DMX Value
Functions
CH1
0-255
Red dimming (from darkness to
brightness)
CH2
0-255
Green dimming (from darkness to
brightness)
CH3
0-255
Blue dimming (from darkness to
brightness)
CH4
0-255
White dimming (from darkness to
brightness)
CH5
0-255
General dimming (from darkness to
brightness)
CH6
0-3
No function
4-255
Color changing (from slow to fast)
CH7
0-3
No function
4-255
Strobe (from slow to fast)
CH8
0-128
Sound Mode 1 (sensitive from low to
high)
129-255
Sound Mode 2 (sensitive from low to
high)
VIII.Appendix
The lightisavailabletoreceivetheDMX512signal, connecttheDMXconnectorto the panel which marked with “DMX
IN”,andconnectit to the next light. then, connect to the “DMX IN” of next light from the “DMXOUT”. The DMX signal
terminator is recommended when the lighting signal is connecting. It will avoid to interfere thesignal which caused by
the electrical noise, DMX terminator is a XLR connector, connect with a 120Ω resistor between the pin 2 and pin 3 of
theXLRconnector, andconnect ittotheOUTPUTsocketofthe finallight.seepicture:
IX. Faulty Disposal
DMXIN

Familiar Faulty
Disposal
Nodisplaywhenpoweris on
1.Checkifthepower cable is correctlyconnected
2.Checkthepowersupplieris correctlyconnected
Lightis outof control
1.CheckifDMXaddresscodeiscorrectlyset
2.CheckiftheDMXcable is correctlyconnected
The lightis off after working for a
while
1.Thetemperatureofworkingenvironmentis toohighandcausedoverheat
protection.
The beam isdark obviously
1.Checkifthetemperatureis toohigh,andcauseafastfade
2.Checkifthereistoo muchdustonthesurfaceof light
Note:
Please contact the supplier or ask for professional repair if it’s still don’t work when excluded the above
faulty.
Table of contents
Popular Floodlight manuals by other brands

Chauvet DJ
Chauvet DJ Intimidator Spot 475ZX Quick reference guide

EuroLite
EuroLite LED IP FL-100 user manual

NORTHCLIFFE
NORTHCLIFFE BOREAS C Installation instruction

hylite
hylite MIGHTYLITE PRO MLP120 Installation & operating instructions

Whelen Engineering Company
Whelen Engineering Company NITEBEAM H.I.D. Mounting guide

Anslut
Anslut 002-524 operating instructions