7
A) End of shaft with nut
B) Washer
C) Elbow
FO 0814
FO 0264
Installation
Im ortant
This appliance must be installed by qualified
personnel.
The installer shall verify the satisfactory operation
of the i nition system on all burners both
individually and in combination.
The manufacturer will not accept liability, should
the above instructions or any of the other safety
instructions incorporated in this book be i nored.
Regulations
This appliance shall be installed in accordance with the
manufacturers installation instructions, local as fittin
re ulations, municipal buildin codes, AS5601 (AG601)
and any other relevant statutory re ulations.
Data label
The data label is located on the bottom of the hob. This
appliance is suitable for Natural or Universal LPG.
Ensure that the as supply matches the data label. A
duplicate of the data label is supplied in the packa in
of the user manual and must be attached to readily
accessible adjacent surfaces of the appliances.
Connection to the gas su ly
Gas connection must be carried out in conformity with
the re ulations in force. The appliance leaves the
factory tested and re ulated for the type of as indicated
on the plate which is situated in the lower position near
the as connection tube. Ascertain that the type of as
with which the appliance will be supplied is the same
as that indicated on the plate.
If different carry out all the operations accordin to the
indications cited in the para raph adaption to different
types of as.
For a maximum output and minimum consumption
ascertain that the pressure of the as used has the
values indicated in the table of burner characteristics.
The joint is mounted on the intake area of the pipe,
fitted with a filleted nut G 1/2", between the sealin
components. Screw the parts without forcin , turn the
joint in the direction required and then ti hten
everythin .
Connection
Carry out the connection to the as plant only by
means of a rigid metallic pipe conformin to the
re ulations in force.
This appliance is not suitable for connection with a hose
assembly.
The joint for the entry of as into the appliance is
threaded R 1/2" (male thread).
Carry out the connection avoidin any type of stress
on the appliance.
It is important to install the elbow correctly, with
the shoulder on the end of the thread, fitted to
the hob connectin pipe. Failure to ensure the
correct assembly will cause leakage of gas.
Natural as appliances must be fitted with a pressure
re ulator and be installed at the inlet connection. The
as pressure must then be set as a part of the
commissionin procedures.
For U-LPG the pressure adjustment is made via the
re ulator fitted at the domestic cylinder. The natural
as re ulator and U-LPG pressure test point must be
accessible with the appliance installed.
Im ortant
Upon completion of installation, always check:
●that all the joints are completely sealed by usin a
soapy solution, never a flame;
●that the as pressure has been re ulated to 1.00kPa
for Natural Gas and 2.75kPa for Universal-LPG. The
pressure test point is located on the re ulator. The
pressure should be measured and adjusted with the
Wok burner on hi h flame;
●that the automatic i nition system is operatin
satisfactory on all burners, both individually and in
combination;
●that the burners operate correctly, are stable, without
yellow tippin or excessive noise on hi h and low
flame.
Then demonstrate to the customer the appliance
operation and leave these instructions.