Elemental LED LUCETTA CELESTE User manual

DRY LOCATION
97+
HIGH CRI
DIMMABLE
24VDC
GOLD PLATED PCB SINGLE SDCM HIGH R9 & RF SKIN SPEC LOCK
INSTALLATION GUIDE |DIM-TO-WARM LED TAPE LIGHT |IG090519-1.0 |1 OF 5
INSTALLATION GUIDE
CELESTE DIM-TO-WARM LINEAR LIGHTING
SAFETY & WARNINGS
DO NOT CONNECT DIRECTLY TO HIGH VOLTAGE POWER!
Read all warnings and installaon instrucons thoroughly.
WARNING
DO NOT CONNECT DIRECTLY TO HIGH VOLTAGE POWER!
Read all warnings and installaon instrucons thoroughly.
WARNING
WARNING!
DO NOT CONNECT DIRECTLY TO LINE
VOLTAGE POWER!
Read all warnings and installation instructions
thoroughly.
HANDLE PRODUCT WITH CARE!
DO NOT BEND LED STRIP
LIGHT TO A DIAMETER LESS
THAN 4 INCHES.
4 in.
DO NOT BEND LED STRIP LIGHT
ON A HORIZONTAL PLANE.
DO NOT COVER STRIP LIGHT WITH
ANY MATERIALS.
DO NOT FOLD, CREASE, OR
TWIST LED STRIP LIGHT.
DO NOT POWER STRIP
LIGHT WHILE ATTACHED TO
SPOOL OR TIGHTLY COILED.
1.Install in accordance with national and local electrical
code regulations.
2.This product is intended to be installed and serviced by
a qualied, licensed electrician.
3.Do not modify or disassemble this product beyond
instructions or the warranty will be void.
4.Do not submerge, or install within 5 feet of a swimming
pool.
5. All plastics are affected by the elements and may shift
in color and other properties after product installation,
particularly with direct exposure to sun, chlorinated
water, and other chemicals.
6.Only install with a Listed Class 2 DC LED driver.
7.To avoid Voltage Drop, ensure wire gauge used with
LED Strip Light is sufcient. Refer to Voltage Drop Chart.
8.Do not exceed maximum run recommended for Strip
Light.
9.CELESTE™LED Strip Light is designed to be cut at
designated cut points only. Cutting anywhere other than
the cut points will result in damage to the Strip Light.
10. Failure to follow safety warnings, and installation
instructions will void the warranty for this product.
POWER SUPPLY
CLASS
2
+ 24V
+ 24V
-
-
W
WWWWWC
C
CC
C
C
+ 24V + 24V
-
-
W W WWWWC
C
CC
C
C
+ 24V
+ 24V
-
-
W W W
WWWC
C
C
C
C
C
+ 24V + 24V
-
-
W W WWWWC
C
CC
C
C

INSTALLATION GUIDE |DIM-TO-WARM LED TAPE LIGHT |IG090519-1.0 |2 OF 5
INSTALLATION GUIDE
CELESTE DIM-TO-WARM LINEAR LIGHTING
Prior to installation, verify all components (LED Tape, Driver, Control, &
Accessories) are compatible. Congure and pre-test your LED system prior to
installation to ensure all components are operating correctly.
SHOCK HAZARD! May result in serious injury
or death.
Turn power OFF at circuit breaker prior to
installation.
+24V
-
+
-
+24V
-
+
-
+24V
-
+
-
+24V
-
+
-
1) Class 2
Magnetic Driver
2) Control 3) Tape Light
Refer to SYSTEM DIAGRAMS.
WIRE GAUGE & VOLTAGE DROP
Ensure applicable wire is installed between driver, xture,
and any controls in between. When choosing wire, factor in
voltage drop, amperage rating, and type (in-wall rated, wet
location rated, etc.)
CUT TAPE LIGHT TO DESIRED LENGTH
+ 24V
-
+
-
+ 24V
-
+
-
+ 24V
-
+
-
+ 24V
-
+
-
+ 24V
-
+
-
+ 24V
-
+
-
+ 24V
-
+
-
+ 24V
-
+
-
Cut at line indicated with scissors icon.
PREPARE CONNECTOR
Using Phillips Head Screwdriver, fasten connector to Strip
Light.
-
+
24V
-
+
-
+
-
+
24V
-
+
-
+
INSERT TAPE LIGHT INTO CONNECTOR
UNSCREW TERMINAL BLOCK CONNECTOR
TERMINAL CONNECTOR
SECURE STRIP LIGHT
Never cut tape attached to a live circuit. Do not exceed Class 2
Limit when loading CELESTE™Connectors.
Firmly insert with 3M™Adhesive backing still intact to
Tape Light.
INSTALLATION
1TURN POWER OFF AT CIRCUIT BREAKER
2
DETERMINE LOCATION TO INSTALL
COMPONENTS
3
4
5
6

INSTALLATION GUIDE |DIM-TO-WARM LED TAPE LIGHT |IG090519-1.0 |3 OF 5
INSTALLATION GUIDE
CELESTE DIM-TO-WARM LINEAR LIGHTING
Prior to mounting, attach to Class 2 magnetic LED Driver, turn on
power and test connection to ensure system is operating properly.
Turn off power again before mounting.
ab
+
-
+ 24V
-
+
-
Clean surface before mounting.
MOUNT TAPE LIGHT
TURN POWER ON AT CIRCUIT BREAKER
SYSTEM WORKING IMPROPERLY?
Turn power OFF at circuit breaker and verify all connections.
Review SYSTEM DIAGRAMS and TROUBLESHOOTING or
call our Technical Support line at 877.817.6028.
Peel off 3M™Adhesive Backing. Ensure ambient
temp is minimum 50 ° F (10 ° C) or tape will not
adhere properly.
Tear off backing along connector edge.
Adhere to a smooth, dry surface, working one end to
the other, being gentle with the LED’s.
INSTALLATION (CONT.)
8.1
8.2
7TEST CONNECTION
8
9

INSTALLATION GUIDE |DIM-TO-WARM LED TAPE LIGHT |IG090519-1.0 |4 OF 5
INSTALLATION GUIDE
CELESTE DIM-TO-WARM LINEAR LIGHTING
TROUBLESHOOTING
Symptom Common Cause
Tape Light does not
illuminate
• Circuit breaker is OFF or tripped.
• Incorrect wiring. Polarity of Low Voltage V+ and V- are reversed. Check connection at every connection point to ensure
polarity is not reversed.
Tape Light Overheats • Ambient temperature above rating. Ensure tape light is installed in environment -4° ~ 122°F (-20° ~ 50°C).
• Voltage input is higher than rated voltage.
Fixture ickers randomly,
may shut off
• Connection is not secure. Check connection at Terminal or splice connector and ensure Terminal screws are fastened
tightly onto Tape Light Solder pads.
Shift in brightness and/
or color
• Review Tape Light maximum series run limit. Exceeding will cause voltage drop, decreasing brightness and/or color shift.
• Review Voltage Drop Chart. Incorrect wire gauge may cause voltage drop and noticeable shift in brightness and/or color.
Tape Light turns on/off
repeatedly
• Driver is overloaded or overheated. An overloaded/overheated driver will trip the internal auto-reset (of driver) repeatedly,
turning the system on/off.
Wire
Gauge 10 W
.42 A 20 W
.83 A 30 W
1.3 A 40 W
1.7 A 50 W
2.1 A 60 W
2.5 A 70 W
2.9 A 80 W
3.3 A 90W
3.75 A 100 W
4. 2 A
20 AWG 85 ft. 43 ft. 27 ft. 21 ft. 17 ft. 14 ft. 12 ft. 11 ft. 9 ft. 8 ft.
18 AWG 134 ft. 68 ft. 45 ft. 33 ft. 27 ft. 22 ft. 19 ft. 17 ft. 15 ft. 14 ft.
16 AWG 215 ft. 109 ft. 72 ft. 54 ft. 43 ft. 36 ft. 31 ft. 27 ft. 24 ft. 22 ft.
14 AWG 345 ft. 174 ft. 115 ft. 86 ft. 69 ft. 57 ft. 49 ft. 43 ft. 39 ft. 36 ft.
12 AWG 539 ft. 272 ft. 181 ft. 135 ft. 108 ft. 90 ft. 77 ft. 68 ft. 61 ft. 56 ft.
10 AWG 784 ft. 397 ft. 263 ft. 197 ft. 158 ft. 131 ft. 112 ft. 98 ft. 97 ft. 82 ft.
24V Voltage Drop & Wire Length Distance Chart
Determine load size. Let’s assume load
is 55 W. Round up to nearest load.
Determine distance from driver to load.
Let’s assume the distance is 20 ft.
Round up to nearest distance.
It’s recommended to install 18 AWG to
eliminate excess voltage drop.
VOLTAGE DROP CHARTS
ADDITIONAL RESOURCES
For best performance and lumen output, ensure proper wire gauge is installed to compensate for voltage drop of low voltage circuits.
Visit the on-line product page at www.LucettaLighting.com for
individual LED Tape Light product specications & warranty
information.
Voltage Drop Chart Guide
1
2
3

INSTALLATION GUIDE |DIM-TO-WARM LED TAPE LIGHT |IG090519-1.0 |5 OF 5
Lucea Lighng is a division of Elemental LED Inc.
885 Trademark Drive, Suite 200 | Reno, NV 89521 | (833) 533-7732| info@LuceaLighng.com
© 2019 Elemental LED Inc. All rights reserved. Specicaons are subject to change without noce.
INSTALLATION GUIDE
CELESTE DIM-TO-WARM LINEAR LIGHTING
SYSTEM DIAGRAMS
The following diagram is provided as an example system design. For information regarding larger systems or systems not
pictured below, please see our web page or contact technical support. Always review each component installation guide for
detailed and up-to-date wiring instructions. Install in accordance with national and local electrical codes.
Magnetic Dimmable Driver System*
1. Driver may not require a fault ground connection. Refer to driver specications for additional information.
2. Install a compatible Class 2 driver. Refer to each driver specication sheet for full power ratings & load deratings.
8. See xture specications for maximum series run limits.
AC Power
50/60Hz
120VAC or 277VAC
Magnetic Low Voltage Dimmer1
V+ (Red)
V- (Blue)
LED Tape Light / Fixture8
LN
N (White)
L (Black)
Magnetic
Dimmable Driver2
Install applicable wire gauge / type
V+
V-
V+
V-
GND (Green)
Some dimmers may require an
additional neutral wire connection.
*If a different Driver from one of our partners is required, please
contact us at www.LucettaLighting.com.
Table of contents
Popular Lighting Equipment manuals by other brands

Larson Electronics
Larson Electronics EPLFL-26W-P-LED-25 instruction manual

Acuity Brands
Acuity Brands HOLOPHANE CORTEZ CZQ6L manual

Gewiss
Gewiss ZNT ATEX manual

RZB Lighting
RZB Lighting GSUN-S Instruction

V-TAC
V-TAC VT-8061 Installation instruction

VS LIGHTING SOLUTIONS
VS LIGHTING SOLUTIONS LiCS OUTDOOR iCTT Mounting instruction