Ele SP17OS User manual

1. The occupancy sensor wall switch turns lighting or fan loads on
and off based on occupancy and ambient light level. They are
designed to replace a standard light switch. The switch operates
with 120 to 277V AC line voltage.
2. The sensor uses passive infrared technology to sense human
motion, and defines it as occupancy. A red LED in the sensor
blinks upon occupancy and then resets. It will blink again when
it detects motion after the 2-second reset.
3. In Automatic ON & Automatic OFF mode, the sensor turns on
the load automatically when it detects occupancy. Once the
space is vacant and the time delay elapses, it turns off the load
automatically.
4. With different settings, occupancy sensors (model# SP17OS)
can be converted to vacancy sensors (model# SP17VS), while
vacancy sensors cannot be converted to occupancy sensors.
5. If adequate ambient light is already present in the area, the
sensor will hold off the load it controls. When the light drops
below a field selectable level and the sensor detects occupancy,
the sensor turns on the load.
MOUNTING LOCATION
The device responds to temperature changes and care should be
taken when mounting the device. Do not mount directly above a
heat source, in a location where hot or cold drafts will blow
directly on the sensor, or where unintended motion (e.g., hallway
traffic) will be within sensor’s field-of-view.
4A - INSTALLATION FOR SINGLE POLE
Slotted / Phillips Screwdriver Pencil
PREPARATION BEFORE INSTALLATION
Single-Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
Two Location Control
1. Line (Hot)
2. Neutral
3. Ground
4. Traveler (note color)
5. Load
1
2
3
4
1
3
4
5
2
If the wiring in the wall box does not resemble any of these
configurations, consult an electrician.
4. Before Wiring the Device:
1. Make sure that the ends of wires from the wall box are straight
(cut if necessary).
2. Remove 5/8" (1.6 cm) of insulation from each wire in the wall box.
3. Use wire connectors to join one 12 AWG supply wire with one or
two 16 AWG or 18 AWG, or to join one 14 AWG supply wire with
one to three 16 AWG or 18 AWG.
NOTE: Three wire connectors provided in the product
package are suitable for copper or copper clad wire only.
For single-pole applications, go to Step 4A.
For two location control applications, go to Step 4B.
Electrical Tape
Pliers
Cutters Ruler
1. Turn OFF Power:
Turn power OFF at circuit breaker (or remove fuse).
2. Remove Wallplate and Switch:
Remove wallplate and switch mouting screws. Carefully
remove switch from wall (do not remove wires).
3. Identify the Type of Circuit:
TOOLS NEEDED FOR INSTALLATION
UNIT FEATURES AND DESCRIPTION
WARNINGS AND CAUTIONS
1. CAUTION: To avoid overheating and possible damage to this
device and other equipment, DO NOT install to control a
receptacle.
2. To be installed and/or used in accordance with appropriate
electrical codes and regulations.
3. If you are unsure about any part of these instructions, consult an
electrician.
4. Use this device with copper or copper clad wire only.
5. Do not use this product to control loads in excess of specified
ratings, or it may cause death, injury or property damage.
6. The sensing switch requires an unobstructed view of room
occupants to detect motion.
7. Hot objects or moving air currents can affect the performance of
the sensing switch.
8. For indoor use only. Operate between 32 to 104 oF (0 to 40 °C).
9. Clean sensor with a piece of soft damp cloth only. Do not use
any chemical cleaners.
Hot (Black) Black
Black
White
Line 120VAC, 60HZ
Green Ground
Neutral (White)
Load
Connect wires per wiring diagram as follows:
1. Connect green ground or bare copper wire in wall box to the
Green wire of the device.
2. Connect the Hot wire in wall box wire to the Black wire of the
device.
3. Connect the Load wire(s) in wall box wire to the Red wire of the
device.
4. Screw wire connectors on clockwise making sure no bare
conductors show below the wire connectors. Secure each
connector with electrical tape.
5. Mount device in wall box with screws provided and mount wall plate.
6. Restore power at circuit breaker or fuse. Installation is complete.
7. Turn on the power, manually press the switch button to check
whether the product is installed correctly, and at the same time
ensure that the LED light in the fresnel lens flashes. Wait about
40s for product booting, the product will work properly.
Green
Black
Red
Ground
Neutral
Hot
Load
Insert wires into
wire connectors
then twist
clockwise
Use electrical
tape to secure
wire connectors
and wires
Red
NOTE:
1. A ground connection is required to operate. Use the ground
wire in the wall box for ground connection. If no ground is
available, consult an electrician. Device will not function if it is
not grounded.
2. The hot (black wire) and load (red wire) must be correctly
connected as stated above, otherwise the device will not
function. If the light never turns on, then try to reverse the hot
and load wiring of the sensor.
Passive Infrared Occupancy Sensor Wall Switch
LED/CFL 300W, Incandescent 600W, 1/2 HP, 120~277VAC, 60Hz
INSTALLATION INSTRUCTIONS
Model No.:
SP17OS (Occupancy Sensor)
SP17VS (Vacancy Sensor)
Line 120VAC, 60HZ
Green
Ground
Green
Ground
4B - INSTALLATION FOR TWO LOCATION CONTROL
Insert wires into
wire connectors
then twist
clockwise
Use electrical
tape to secure
wire connectors
and wires
PREPARATION FOR UNIT SETTING SETTING FOR DIFFERENT MODES
QUICK TEST
Hot (Black)
Neutral (White)
Black Red Black
White
Load
Black
Red
ONE YEAR LIMITED WARRANTY
Floor
Side View Top View
4.0’
(1.2m)
35’
(10.7m)
15’
35’
(10.7m)
TIME
SENSOR
LIGHT
Fresnel Lens
0
COVERAGE PATTERNSThe warranty gives you specific rights and you may also have
other rights, which vary in different states and countries. Our
company warrants to the original consumer purchaser that this
product is free of defects in materials and workmanship for 1 year
from the purchase date. This warranty does not cover labor for
removal or reinstallation of the product and is void on any product
installed improperly or in an improper environment, overloaded,
misused, opened, abused, or altered in any manner. Our company
excludes incidental or consequential damages for breach of any
warranty on this product. Some jurisdictions may not allow
limitations on how long an implied warranty lasts or the exclusion
or limitation of incidental or consequential damages, so the above
exclusions or limitations may not apply to you.
The sensor detects motion in areas up to 900 sq. ft. and up to 35
feet from the sensor. Ideally, the sensor is designed for small
amounts of motion in space up to 300 sq. ft. The fresnel lens on
the sensor is a multiple segment viewing lens with a field of view
of 180°. The sensor must have a clear view of the people in the
space in order to detect occupancy. Obstructions, such as
furniture blocking the sensor’s lens, may prevent occupancy
detection.
Connect wires per wiring diagram as follows:
1. Connect green ground or bare copper wire in the wall box to the
Green wire of the device.
2. Connect Hot wire in the wall box to the Black wire of the device.
3. Connect Load wire(s) and Traveler wire in the wall box wire to
the Red wire of the device.
4. Screw wire connectors on clockwise making sure no bare
conductors show below the wire connectors. Secure each
connector with electrical tape.
5. Mount device in the wall box with screws and mount wall plate.
6. Repeat step 1-6 for installing another sensor switch to the wires
in the wall box. (the load wire may only exists in one wall box)
7. Restore power at circuit breaker or fuse. Installation is complete.
8. Turn on the power, manually press the switch button to check
whether the product is installed correctly, and at the same time
ensure that the LED light in the fresnel lens flashes. Wait about
40s for product booting, the product will work properly.
1. Pry off the top cover with a slotted screwdriver.
2. Set 3 controls of TIME, SENSOR and LIGHT after cover is off.
Set delay TIME to "0" to automatically turn off the light after 30
seconds and set LIGHT to “ • ” to disable light sensitivity, this
allows you to quickly check the sensor coverage area.
NOTE:
1. Either sensor can turn the lights ON.
2. Either sensor must time-out to OFF, or both manual buttons
must be pressed for the lights to turn OFF.
3. A ground connection is required to operate. Use the ground
wire in the wall box for ground connection. If no ground is
available, consult an electrician. Device will not function if it is
not grounded.
4. The hot (black wire) and load (red wire) must be correctly
connected as stated above, otherwise the device will not
function. If the light never turns on, then try to reverse the hot
and load wiring of either or both sensors.
Green
Black
Red
Ground
Neutral
Traveler
Load
Hot
Disable Automatic OFF function
Automatically turn off the light after 30 seconds
Automatically turn off the light after 5 minutes
Automatically turn off the light after 15 minutes
Automatically turn off the light after 30 minutes
0
1
2
3
TIME NOTE
Disable Automatic ON function
Automatically turn on the light in dark environment
Automatically turn on the light in brighter environment than LIGHT 1
Automatically turn on the light in any light environment, including
the bright day
1
2
3
NOTELIGHT
Top Cover
(Manual Switch)
Delay Time Sensor Sensitivity Light Sensitivity
Manual Switch
A. Automatic ON & Automatic OFF Mode:
1. Set human body SENSOR sensitivity as desired.
2. Set delay TIME to "0" (30 seconds), “1” (5 minutes), “2” (15
minutes) or "3" (30 minutes) as desired.
3. Set LIGHT sensitivity to “1”, “2” or "3" as desired.
For LIGHT "1", it will automatically turn on the light only in dark
environment, like during the night.
For LIGHT “2”, it will automatically turn on the light in brighter
environment than LIGHT “1”.
For LIGHT "3", it will automatically turn on the light in any light
environment, including the bright day. (Default Setting: 30
seconds delay TIME, maximum SENSOR sensitivity, maximum
LIGHT sensitivity)
B. Manual ON & Automatic OFF Mode:
1. Set human body SENSOR sensitivity as desired.
2. Set delay TIME to "0" (30 seconds), “1” (5 minutes), “2” (15
minutes) or "3" (30 minutes) as desired.
3. Set LIGHT sensitivity fully counterclockwise to “ • ” to disable
automatic ON function.
C. Manual ON & Manual OFF Mode:
1. Set delay TIME fully counterclockwise to “ • ” to disable
automatic OFF function.
2. Set LIGHT sensitivity fully clockwise to “3”.
Human body SENSOR function will be disabled automatically.
(4.6m)
ELE GROUP CO., LTD
NO.158 CHUANGYUAN ROAD, SIP
SUZHOU, JIANGSU, CHINA 215125
WWW.ELEGRP.COM
TIME SENSOR LIGHT

This manual suits for next models

1

Popular Lighting Equipment manuals by other brands

MJ LED LIGHTNING MJ-1029A user manual

MJ LED LIGHTNING

MJ LED LIGHTNING MJ-1029A user manual

OBI Valero 205 263 quick start guide

OBI

OBI Valero 205 263 quick start guide

Moda Light FLATFLEX HCRI INTERIOR Installation

Moda Light

Moda Light FLATFLEX HCRI INTERIOR Installation

Lupo Smartpanel user manual

Lupo

Lupo Smartpanel user manual

LED World HH-S3527X-120-24 Important instructions

LED World

LED World HH-S3527X-120-24 Important instructions

GE 73007 Installation and operation manual

GE

GE 73007 Installation and operation manual

Lena Lighting UV-C STERILON BASIC user manual

Lena Lighting

Lena Lighting UV-C STERILON BASIC user manual

Eterna VECOEM3M installation instructions

Eterna

Eterna VECOEM3M installation instructions

American DJ Color Burst 8 DMX User instructions

American DJ

American DJ Color Burst 8 DMX User instructions

Exo Terra PT2335 operating instructions

Exo Terra

Exo Terra PT2335 operating instructions

Gruppe OSEAN 318.02 User documentation

Gruppe

Gruppe OSEAN 318.02 User documentation

THORLABS PSY240E installation manual

THORLABS

THORLABS PSY240E installation manual

Hikariya Lighting HL-DFL-F280 Handling manual

Hikariya Lighting

Hikariya Lighting HL-DFL-F280 Handling manual

Laserworld PRO-7000R/640 user manual

Laserworld

Laserworld PRO-7000R/640 user manual

ArtFox SHINE BAR 12Q user manual

ArtFox

ArtFox SHINE BAR 12Q user manual

DTS Discharge Lamp 35-70-150W user manual

DTS

DTS Discharge Lamp 35-70-150W user manual

RZB Lighting GSUN-S Instruction

RZB Lighting

RZB Lighting GSUN-S Instruction

Snowfall SF165MM installation manual

Snowfall

Snowfall SF165MM installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.