Line 120VAC, 60HZ
Green
Ground
Green
Ground
4B - INSTALLATION FOR TWO LOCATION CONTROL
Insert wires into
wire connectors
then twist
clockwise
Use electrical
tape to secure
wire connectors
and wires
PREPARATION FOR UNIT SETTING SETTING FOR DIFFERENT MODES
QUICK TEST
Hot (Black)
Neutral (White)
Black Red Black
White
Load
Black
Red
ONE YEAR LIMITED WARRANTY
Floor
Side View Top View
4.0’
(1.2m)
35’
(10.7m)
15’
35’
(10.7m)
TIME
SENSOR
LIGHT
Fresnel Lens
0
COVERAGE PATTERNSThe warranty gives you specific rights and you may also have
other rights, which vary in different states and countries. Our
company warrants to the original consumer purchaser that this
product is free of defects in materials and workmanship for 1 year
from the purchase date. This warranty does not cover labor for
removal or reinstallation of the product and is void on any product
installed improperly or in an improper environment, overloaded,
misused, opened, abused, or altered in any manner. Our company
excludes incidental or consequential damages for breach of any
warranty on this product. Some jurisdictions may not allow
limitations on how long an implied warranty lasts or the exclusion
or limitation of incidental or consequential damages, so the above
exclusions or limitations may not apply to you.
The sensor detects motion in areas up to 900 sq. ft. and up to 35
feet from the sensor. Ideally, the sensor is designed for small
amounts of motion in space up to 300 sq. ft. The fresnel lens on
the sensor is a multiple segment viewing lens with a field of view
of 180°. The sensor must have a clear view of the people in the
space in order to detect occupancy. Obstructions, such as
furniture blocking the sensor’s lens, may prevent occupancy
detection.
Connect wires per wiring diagram as follows:
1. Connect green ground or bare copper wire in the wall box to the
Green wire of the device.
2. Connect Hot wire in the wall box to the Black wire of the device.
3. Connect Load wire(s) and Traveler wire in the wall box wire to
the Red wire of the device.
4. Screw wire connectors on clockwise making sure no bare
conductors show below the wire connectors. Secure each
connector with electrical tape.
5. Mount device in the wall box with screws and mount wall plate.
6. Repeat step 1-6 for installing another sensor switch to the wires
in the wall box. (the load wire may only exists in one wall box)
7. Restore power at circuit breaker or fuse. Installation is complete.
8. Turn on the power, manually press the switch button to check
whether the product is installed correctly, and at the same time
ensure that the LED light in the fresnel lens flashes. Wait about
40s for product booting, the product will work properly.
1. Pry off the top cover with a slotted screwdriver.
2. Set 3 controls of TIME, SENSOR and LIGHT after cover is off.
Set delay TIME to "0" to automatically turn off the light after 30
seconds and set LIGHT to “ • ” to disable light sensitivity, this
allows you to quickly check the sensor coverage area.
NOTE:
1. Either sensor can turn the lights ON.
2. Either sensor must time-out to OFF, or both manual buttons
must be pressed for the lights to turn OFF.
3. A ground connection is required to operate. Use the ground
wire in the wall box for ground connection. If no ground is
available, consult an electrician. Device will not function if it is
not grounded.
4. The hot (black wire) and load (red wire) must be correctly
connected as stated above, otherwise the device will not
function. If the light never turns on, then try to reverse the hot
and load wiring of either or both sensors.
Green
Black
Red
Ground
Neutral
Traveler
Load
Hot
Disable Automatic OFF function
Automatically turn off the light after 30 seconds
Automatically turn off the light after 5 minutes
Automatically turn off the light after 15 minutes
Automatically turn off the light after 30 minutes
0
1
2
3
TIME NOTE
Disable Automatic ON function
Automatically turn on the light in dark environment
Automatically turn on the light in brighter environment than LIGHT 1
Automatically turn on the light in any light environment, including
the bright day
1
2
3
NOTELIGHT
Top Cover
(Manual Switch)
Delay Time Sensor Sensitivity Light Sensitivity
Manual Switch
A. Automatic ON & Automatic OFF Mode:
1. Set human body SENSOR sensitivity as desired.
2. Set delay TIME to "0" (30 seconds), “1” (5 minutes), “2” (15
minutes) or "3" (30 minutes) as desired.
3. Set LIGHT sensitivity to “1”, “2” or "3" as desired.
For LIGHT "1", it will automatically turn on the light only in dark
environment, like during the night.
For LIGHT “2”, it will automatically turn on the light in brighter
environment than LIGHT “1”.
For LIGHT "3", it will automatically turn on the light in any light
environment, including the bright day. (Default Setting: 30
seconds delay TIME, maximum SENSOR sensitivity, maximum
LIGHT sensitivity)
B. Manual ON & Automatic OFF Mode:
1. Set human body SENSOR sensitivity as desired.
2. Set delay TIME to "0" (30 seconds), “1” (5 minutes), “2” (15
minutes) or "3" (30 minutes) as desired.
3. Set LIGHT sensitivity fully counterclockwise to “ • ” to disable
automatic ON function.
C. Manual ON & Manual OFF Mode:
1. Set delay TIME fully counterclockwise to “ • ” to disable
automatic OFF function.
2. Set LIGHT sensitivity fully clockwise to “3”.
Human body SENSOR function will be disabled automatically.
(4.6m)
ELE GROUP CO., LTD
NO.158 CHUANGYUAN ROAD, SIP
SUZHOU, JIANGSU, CHINA 215125
WWW.ELEGRP.COM
TIME SENSOR LIGHT