ELGO Electronic PMIX Series User manual

Operating Manual
SERIES PMIX
Mechanically guided Incremental Linear Encoder
Wear-free alternative to conventional linear measuring systems
Also ideally suited as a digital potentiometer replacement
Technically based on LMIX resp. EMIX sensors or in combination
with a battery powered ELGO display units of the series IZ
Available resolutions: 0.1 / 0.025 / 0.01 or 0.001mm depending
on selected measuring system (LMIX, EMIX, EMIX23 or IZ display unit)
Measuring lengths of 100, 200, 400 and 600 mm (others on request)
The sensor head and the magnetic tape are permanently integrated
in the guide cylinder, which ensures an optimal mechanical guidance
799000215 / Rev. 0 / 2019-05-15
Translation of the original operating manual

Contents
- 3 -
1Contents
1Contents ..................................................................................................... 3
2General, Safety, Transport and Storage .................................................... 4
2.1 Information Operating Manual ........................................................................................... 4
2.2 Explanation of Symbols...................................................................................................... 4
2.3Statement of Warranties..................................................................................................... 5
2.4 Demounting and Disposal.................................................................................................. 5
2.5 General Causes of Risk ..................................................................................................... 5
2.6 Personal Protective Equipment ............................................................................................ 5
2.7 Conventional Use ............................................................................................................. 5
2.8 Safety Instructions for Transport, Unpacking and Loading ....................................................... 6
2.9 Handling of Packaging Material.......................................................................................... 6
2.10 Inspection of Transport ...................................................................................................... 6
2.11 Storage ........................................................................................................................... 6
3Product Features ........................................................................................ 7
3.1 General........................................................................................................................... 7
3.2 Functional Principle........................................................................................................... 7
3.3 Typical Applications .......................................................................................................... 7
3.4 Measuring Systems and Resolutions ..................................................................................... 8
3.5 Power Supply Voltages and Output Levels ............................................................................ 8
3.6 Pulse diagram .................................................................................................................. 8
4Technical Data ........................................................................................... 9
4.1 Identification .................................................................................................................... 9
4.2 Dimensions Sensor............................................................................................................ 9
4.3 Technical Data PMIX ....................................................................................................... 10
4.4 Technical Data Magnetic Tape ......................................................................................... 11
5Installation and First Start-Up ................................................................. 12
5.1 Operating Area .............................................................................................................. 12
6Connections.............................................................................................. 13
6.1 Pin assignment with open cable ends (standard) .................................................................. 13
6.2 Pin assignment with 9 pin D-SUB connector (Option D1)...................................................... 13
7Disturbances, Maintenance, Cleaning ..................................................... 14
7.1 Fault Clearance.............................................................................................................. 14
7.2 Re-start after Fault Clearance ........................................................................................... 14
7.3 Maintenance .................................................................................................................. 15
7.4 Cleaning ....................................................................................................................... 15
8Type designation...................................................................................... 16
9Index ........................................................................................................ 19

General, Safety, Transport and Storage
- 4 -
2General, Safety, Transport and Storage
2.1 Information Operating Manual
This manual contains important information regarding the handling of the device. For your own safety and operational safety, please ob-
serve all safety warnings and instructions. Precondition for safe operation is the compliance with the specified safety and handling instruc-
tions. Moreover, the existing local accident prevention regulations and the general safety rules at the site of operation have to be observed.
Please read the operating manual carefully before starting to work with the device! It is part of the product and should be kept close to the
device and accessible for the staff at any time. The illustrations in the manual are for better demonstration of the facts. They are not neces-
sarily to scale and can slightly differ from the actual design.
2.2 Explanation of Symbols
Special notes in this manual are characterized by symbols. The notes are introduced by signal words which express the magnitude of danger.
Please follow this advice and act carefully in order to avoid accidents, damage, and injuries.
Warning notes:
DANGER!
This symbol in connection with the signal word “Danger” indicates an immediate danger for the life and health of
persons. Failure to heed these instructions can result in serious damage to health and even fatal injury.
WARNING!
This symbol in connection with the word „Warning” means a possibly impending danger for the life and health of
persons. Failure to heed these instructions can result in serious damage to health and even fatal injury.
CAUTION!
This symbol in connection with the signal word “Caution” indicates a possibly dangerous situation. Failure to heed
these instructions can lead to minor injuries or damage of property.
Special safety instructions:
DANGER!
This symbol in connection with the signal word “Danger” indicates an immediate danger for the life and health of
persons due to voltage.
Failure to heed these instructions can result in serious damage to health and even fatal injury. The operations may
only be carried out by a professional electrician.
Tips and recommendations:
NOTE!
…points out useful tips and recommendations as well as information for an efficient and trouble-free operation.
Reference marks:
Marks a reference to another chapter of this manual.
Marks a reference to another chapter of another document.

General, Safety, Transport and Storage
- 5 -
2.3 Statement of Warranties
The producer guarantees the functional capability of the process engineering and the selected parameters.
2.4 Demounting and Disposal
Unless acceptance and disposal of returned goods are agreed upon, demount the device considering the safety instructions of this manual
and dispose it with respect to the environment.
Before demounting, disconnect the power supply and secure against re-start. Then disconnect the supply lines physically and discharge
remaining energy. Remove operational supplies and other material.
Disposal:
Recycle the decomposed elements: Metal components in scrap metal, Electronic components in electronic scrap, Recycle plastic compo-
nents, dispose the remaining components according to their material consistence.
CAUTION!
Wrong disposal causes environmental damages!
Electronic scrap, electronic components, lubricants and other auxiliary materials are subject to special refuse and can
only be disposed by authorized specialists!
Local authorities and waste management facilities provide information about environmentally sound disposal.
Safety
CAUTION!
Please read the operating manual carefully, before using the device! Observe the installation instructions!
Only start up the device if you have understood the operating manual.
The operating company is obliged to take appropriate safety measure.
The initial operation may only be performed by qualified and trained staff.
Selection and installation of the devices as well as their embedding into the controlling system require qualified
knowledge of the applicable laws and normative requirements on the part of the machine manufacturer.
2.5 General Causes of Risk
This chapter gives an overview of all important safety aspects to guarantee an optimal protection of employees and a safe and trouble-free
operation. Non-observance of the instructions mentioned in this operating manual can result in hazardous situations.
2.6 Personal Protective Equipment
Employees have to wear protective clothing during the installation of the device to minimize danger of health.
Therefore:
Change into protective clothing before performing the works and wear them throughout the process.
Additionally observe the labels regarding protective clothing in the operating area.
Protective clothing:
PROTECTIVE CLOTHING
… is close-fitting working clothing with light tear strength, tight sleeves and without distant parts. It serves preliminari-
ly for protection against being gripped by flexible machine parts.
Do not wear rings, necklaces or other jewelry.
PROTECTIVE GLOVES
…for protecting the hands against abrasion, wear and other injury of the skin.
PROTECTIVE HELMET
…for protection against injuries of the head.
2.7 Conventional Use
The product described in this manual was developed to execute safety-related functions as a part of an entire assembly or machine.
The ELGO device type PMIX only serves to measure lengths and linear movements.

General, Safety, Transport and Storage
- 6 -
CAUTION!
Danger through non-conventional use!
Non-intended use and non-observance of this operating manual can lead to dangerous situations.
Therefore:
Only use the device as described
Strictly follow the instructions of this manual
Avoid in particular:
Remodeling, refitting or changing of the construction or single components with the intention to alter the
functionality or scope of the device.
Claims resulting from damages due to non-conventional use are not possible.
Only the operator is liable for damages caused by non-conventional use.
2.8 Safety Instructions for Transport, Unpacking and Loading
CAUTION!
Transport the package (box, palette etc.) professionally.
Do not throw, hit or fold it.
2.9 Handling of Packaging Material
Notes for proper disposal: 2.4
2.10 Inspection of Transport
Check the delivery immediately after the receipt for completeness and transport damage.
In case of externally recognizable transport damages:
Do not accept the delivery or only accept under reserve.
Note the extent of damages on the transportation documents or delivery note.
File complaint immediately.
NOTE!
Claim any damage immediately after recognizing it.
The claims for damage must be filed in the lawful reclaim periods.
2.11 Storage
Store the device only under the following conditions:
Do not store outside
Keep dry and dust-free
Do not expose to aggressive media
Protect from direct sun light
Avoid mechanical shocks
Storage temperature (4) needs to be observed
Relative humidity (4) must not be exceeded
Inspect packages regularly if stored for an extensive period of time (>3 months)

Product Features
- 7 -
3Product Features
3.1 General
The guided measuring system PMIX is based on the magnetic length measuring systems LMIX or EMIX. Due to
the magnetic (and therefore contactless) measuring principle, it is a wear-free alternative to conventional linear
encoders.
Figure 1: PMIX in combination with an IZ16E display unit
Depending on the ordered version, an LMIX, EMIX or EMIX23 sensor can be integrated in the PMIX housing. As
shown in the photo above, the PMIX system can be combined with the battery-powered ELGO position indica-
tors IZ14E, IZ15E, IZ16E and IZ17E. In this case sensor and resolution comply with the selected IZ unit. Further
no wiring is necessary. The respective ordering suffix is specified in the type designation (8).
The sensor head and the magnetic tape (4.4) are already integrated in a mechanical cylinder (standard
measuring lengths are 100/200/400/600 mm). The sensor is optimally guided at linear movements. Thus the
system can immediately be installed and connected.
3.2 Functional Principle
Integrated in the sensor head are the magneto-resistive measuring-bridges, the interpolation circuit and the
output drivers. The bridge generates the distance dependent counting pulses for the signal processing electronic.
The sensor cable is an 8-wire cable, highly flexible and suitable for drag chains. It consists of twisted pair wires
and is shielded.
3.3 Typical Applications
The series PMIX is suitable for a variety of applications in machine and plant engineering. For example, it can be
used everywhere where linear potentiometers are used, since the PMIX linear encoder is also suitable as a digital
potentiometer replacement.
Typical applications in the range of machine engineering are e. g.
Hydraulic presses
Injection molding machines
Stroke adjustments
Pick & Place systems
Dosing machines and systems
and many other applications in the plastics, metal, wood, paper
and textile processing or with packaging machines.

Product Features
- 8 -
3.4 Measuring Systems and Resolutions
The PMIX resolution is depending on the selected basis measuring system (see type designation 8).
The following table will show all available versions.
Table 1: Measuring Systems and Resolutions
Measuring System
Resolution
Magnetic tape pole pitch
LMIX
0.1 mm at single edge triggering
0.025 mm at four edge triggering
5 mm
EMIX
0.01 mm at four edge triggering
2 mm
EMIX23
0.001 mm at four edge triggering
2 mm
IZ14E/15E/16E/17E
0.01 mm / 0.1 mm (einstellbar via Parameter)
2.5 mm
3.5 Power Supply Voltages and Output Levels
For the LMIX and EMIX based versions, the following combinations are available:
1. Order suffix 00* = 10 … 30 VDC power supply / output levels 10 … 30 V-HTL
2. Order suffix 01* = 10 … 30 VDC power supply / output levels 5 V-TTL line driver
3. Order suffix 11* = 5 VDC power supply / output levels 5 V-TTL line driver
* Order suffix (see type designation 8)
Note: To reach the largest possible interference distance it is recommended to supply the
PMIX linear encoder with 10 … 30 VDC and to select the A/B signals 5 V-TTL-compatible
with differential evaluation.
3.6 Pulse diagram
Figure 2: Output pulse diagram
B
B‘
Z
Z‘
A
A‘
Channel A and B are
phase shifted by 90°
The index pulse output is
periodically every 2 mm (EMIX)
resp. 5 mm (LMIX)

Technical Data
- 9 -
4Technical Data
4.1 Identification
The type label serves for the identification of the unit. It is located on the housing of the sensor and gives the
exact type designation (8) with the corresponding part number. Furthermore, the type label contains a
unique, traceable device number. When corresponding with ELGO please always indicate this data.
4.2 Dimensions Sensor
Note: The swivel head „SAKB5F“shown in the drawing above is an accessorial part (see op-
tion M1 and M2 in the type designation 8). With M0 standard versions the scope of deliv-
ery includes always 4 holding plates as mounting parts (see also above).
60 + measuring distance
M5 / 16 deep
min.2
measuring distance
swivel head SAKB5F holding plate

Technical Data
- 10 -
4.3 Technical Data PMIX
While the mechanical data at PMIX are fixed, the electrical data differ because they are based on the respective
selected measuring system. In addition, there are differences with the variants of supply voltages and output
levels. The table below will show all available variants with the corresponding technical data.
Table 2: Technical Data PMIX
PMIX-000
Mechanical data
Housing material cylinder
Aluminium
Housing material sensor
Plastic
Dimensions
4.2
Integrated magnetic tape
4.4
Electrical data
Order suffix (8)
Power supply voltage
Outputs levels
Consumption
Cable length
00
10 … 30 VDC, ±10 %
10 … 30 V
max. 150 mA
max. 30 m
01
10 … 30 VDC, ±10 %
5 V-TTL Line Driver
max. 150 mA
max. 50 m
11
5 VDC, ±5 %,
(Residual ripple< 50 mV)
5 V-TTL Line Driver
max. 200 mA
max. 10 m
99
The sensor is already supplied by the battery power of the IZ position indicator
Output current
max. 20 mA pro channel
Outputs
Push-pull, durable short circuit proof
Index pulse
The pulse duration depends on the operation speed
Resolution and
Repeat Accuracy
LMIX: 0.025 mm (four edge triggering), resp. 0.1mm (single edge triggering)
EMIX: 0.01 mm (four edge triggering)
EMIX23: 0.001 mm (four edge triggering)
Series IZ: 0.01 mm / 0.1 mm (selectable by parameter menu)
Output frequency
LMIX: max. 80 kHz per channel
EMIX: max. 200 kHz per channel
EMIX23: max. 1 MHz per channel
Operation speed
(at optimal evaluation)
LMIX: max. 5.0 m/s
EMIX: max. 4.0 m/s
EMIX23: max. 2.0 m/s
Series IZ: max. 4.0 m/s
Ambient conditions
Operating temperature
-10 ... +70° C
(-25 … +85° C) on request
Storage temperature
-25 … +85° C
Protection class
Cylinder: IP40
Sensor: IP65

Technical Data
- 11 -
4.4 Technical Data Magnetic Tape
With a PMIX system, the magnetic tape is already integrated in the guide cylinder and thus must not be installed.
The magnetic tape consists of two components:
The actual magnetic tape which carries the position information
A mechanical stainless steel back iron
Table 3: Technical Data Magnetic Tape
Magnetic tapes for PMIX
Used type of magnetic tape
with LMIX sensor: MB20-50-10-1-R
with EMIX sensor: MB20-20-10-1-R
with IZ indicator: MB 20-25-10-1-R
Coding
Incremental, single track system
Pole pitch
with LMIX sensor: 5 mm
with EMIX sensor: 2 mm
with IZ indicator: 2.5 mm
Operating temperature
-20 °C … +65 °C
Relative humidity
max. 95 %, non-condensing
Accuracy at 20° C in mm
with LMIX sensor: ± (25 µm + 20 µm x L)
with EMIX sensor: ± (20 µm + 20 µm x L)
with IZ indicator: ± (25 µm + 20 µm x L)
L = measuring length in meters
Material carrier tape
Precision strip 1.4310 / X10CrNi 18-8 (EN 10088-3)
Double-faced adhesive tape
3M-9088
Length expansion coefficient
16 x 10-6 1/K
Thermal length expansion
∆L[m] = L[m] x [1/K] x ∆[K]
(L = tape length in meters, ∆= relative temperature change)
Influence of external magnets
External magnetic fields must not exceed 64 mT (640 Oe; 52 kA/m) on
the surface of the magnetic tape because this could damage or destroy
the code on the tape.
Protection class
IP65
4.4.1 Resistance against Chemical Influence
In contact with various substances behaves the magnetic tape (integrated in the guide cylinder) as follows:
Table 4: Resistance against Chemical Influence
Show no or little effect in constant contact after 2-5 years:
formic acid
glycerol 93°C
linseed oil
soy beans oil
cotton seed oil
N-hexane
lactic acid
formaldehyde 40%
Iso octane
petroleum
Show weak to moderate effects in constant contact after approximately 1 year:
acetone
gasoline
acetic acid 30%
oleic acid
acetylene
steam
acetic acid, pure acetic acid
sea water
ammonia
acetic acid 20%
isopropyl ether
stearic acid 70°C, anhydrous
kerosene
Have strong effects when contacting permanently after 1-5 months:
benzene
nitric acid 70%
turpentine
toluene
lacquer solvent
nitric acid, red, vitriolic
carbon tetrachloride
tetrahydrofuran
trichloroethylene
nitrobenzene
hydrochloric acid 37%, 93°C
xylene

Installation and First Start-Up
- 12 -
5Installation and First Start-Up
CAUTION
Please read the operating manual carefully before using the device! Strictly observe the Installation instructions!
In case of damage caused by failure to observe this operating manual, the warranty expires.
ELGO is not liable for any secondary damage and for damage to persons, property or assets.
The operator is obliged to take appropriate safety measures.
The first start-up may only be performed by qualified staff that has been trained and authorized by the operator.
5.1 Operating Area
WARNING!
Do not use the device in explosive or corrosive environments!
The device must not be installed close to sources of strong inductive or capacitive interference or strong electrostatic
fields!
NOTE: External Magnetic Fields
The magnetic tape must not be influenced by external magnetic fields! The PMIX cylinder equipped with magnetic
tape must not come into direct contact with other magnetic fields (e.g. permanent magnets, magnetic clamps, elec-
tromagnets, magnetic stands)! This may cause irreparable damage, which will compromise the measuring accuracy
or even the functioning.
CAUTION!
The electrical connections must be made by suitably qualified personnel in accordance with local regulations.
The device may be designed for switchboard mounting. During work on the switchboard, all components must be de-
energized if there is a danger of touching the energized parts!
(protection against contacts)
Wiring works may only be performed in the de-energized state!
Thin cable strands have to be equipped with end sleeves!
Before switching on the device, connections and plug connectors have to be checked!
The device must be mounted in a way that it is protected against harmful environmental influences such as splashing
water, solvents, vibration, shock and severe pollution and the operating temperature must not be exceeded.

Connections
- 13 -
6Connections
6.1 Pin assignment with open cable ends (standard)
Table 5: Pin Assignment (standard version)
Color
Function
White
0 V (GND)
Brow
5 VDC / 10 … 30 VDC in
Green
Channel A
Yellow
Channel B
Black
Channel Z
Violet
Channel A‘
Orange
Channel B‘
Grey
Channel Z‘
Screen/Shield
PE
6.2 Pin assignment with 9 pin D-SUB (Option D1)
Table 6: Pin Assignment (Option D1)
Color
Function
1
0 V (GND)
2
5 VDC / 10 … 30 VDC in
3
Channel A
4
Channel B
8
Channel Z
6
Channel A‘
7
Channel B‘
9
Channel Z‘
Screen/Shield
connected to housing

Disturbances, Maintenance, Cleaning
- 14 -
7Disturbances, Maintenance, Cleaning
This chapter describes possible causes for disturbances and measures for their removal. In case of increased disturbances, please follow the
measures for fault clearance in chapter 7.1. In case of disturbances that cannot be eliminated by following the advice and the fault clear-
ance measures given here, please contact the manufacturer (see second page).
7.1 Fault Clearance
CAUTION!
The device, the connection line and the signal cable must not be installed next to sources of interference that emit
strong inductive or capacitive interference or strong electrostatic fields.
External perturbations can be avoided thorough suitable cable routing.
The screen of the signal output cable should only be connected to the following circuit on one side. The screens
should not be grounded on both sides. Signal cables always have to be routed separately from the load power line.
A safety distance of at least 0.5 m has to be kept from inductive and capacitive sources of interference such as con-
tactors, relays, motors, switching power supplies, clocked controllers etc.!
If interferences occur in spite of all the items stated above being observed, please proceed as follows:
1. Installation of RC-circuits via contactor coils of AC-contactors (e.g. 0,1 µF / 100 Ω)
2. Installation of recovery diodes via DC-inductors
3. Installation of RC-circuits via the different motor phases (in the terminal box of the motor)
4. Do not connect protective earth and ground
5. Connect a mains filter ahead of the external power pack
7.2 Re-start after Fault Clearance
After the fault clearance:
1. Reset the emergency stop mechanism if necessary
2. Reset the error report at the super-ordinate system if necessary.
3. Ensure that there are no persons in the danger area.
4. Follow the instructions from chapter 5.
WARNING!
Danger of injury through non-conventional fault clearance!
Non-conventional fault clearance can lead to severe injuries and damage of property.
Therefore:
Any work to clear the faults may only be performed by sufficiently qualified staff
Arrange enough space before starting the works
Make sure that the mounting area is clean and tidy. Loose components and tools are sources of accidents.
If components need to be replaced:
Pay attention to a correct installation of the spare parts.
Reinstall all the fixing elements properly
Before turning on the device, ensure that all covers and safety equipment is installed correctly and functions
properly

Disturbances, Maintenance, Cleaning
- 15 -
7.3 Maintenance
The device is maintenance-free.
7.4 Cleaning
WARNING!
The device can only be cleaned with a damp cloth, do not use aggressive cleanser!

Type designation
- 16 -
8Type designation
NOTE
When ordering, please use the here described ordering code (Type Designation).
Options that are not required are filled in with „-„.
PMIX BB,B DDCAAA FF- - - - -
Series / Type:
PMIX
SN Number:
00 ELGO standard
01 First special version, etc.
Signal cable length in XX.X m
1,5 m standard length for LMIX/EMIX/EMIX23
1,0 m standard length forIZ14E/IZ15E/IZ16EIZ17E
Resolution / basis system:
10,025 mm* with LMIX sensor
2 0,01 / 0,1 mm** combined with IZ14E
3 0,01 mm* with EMIX sensor
6 0,01 / 0,1 mm** combined with IZ17E
70,001 mm* with EMIX23 sensor
80,01 / 0,1 mm** combined with IZ15E
90,01 / 0,1 mm** combined with IZ16E
*) at 4 edge triggering
**) selectable by parameter menu
Power supply / output levels:
00 10 … 30 VDC / 10 … 30 V-HTL
01 10 … 30 VDC / 5 V-TTL line driver
11 5VDC / 5 V-TTL line driver
99 Battery powered (for combinations with IZ display units)
EEEE -
Measuring length:*
0100 100 mm
0200 200 mm
0400 400 mm
0600 600 mm (other lengths on request)
*) Entire length of PMIX = Measuring length + 60 mm
Ordering example:
PMIX-000-01.5-1-00-0200-D1-M0
ELGO standard PMIX with a 1.5 m long signal cable, 0.025 mm resolution (at 4 edge triggering),
power supply 10 … 30 VDC / output levels 10 … 30 V, a measuring length of 200 mm, with a
9 pin D-SUB connector and 4 holding plates (without swivel heads).
G-
Options:
D1 9 pin D-SUB connector
(ELGO standard pin assignment)
Mounting parts:
M0 with 4 holding plates (standard)
M1 with 1 swivel head „SAKB5F“ and 4 holding plates
M2 with 2 swivel heads „SAKB5F“

Type designation
- 17 -
Notes:

Type designation
- 18 -
Notes:

Index
- 19 -
9Index
Accident prevention regulations...........................4
Causes of risk....................................................5
Cleaning...................................................14, 15
Connections.................................................... 13
Demounting ...................................................... 5
Device number .................................................. 9
Dimensions Sensor............................................. 9
Disposal............................................................ 5
Disturbances ................................................... 14
Explanation of symbols....................................... 4
Fault clearance................................................14
First start-up .................................................... 12
Functional Principle............................................7
General ............................................................ 7
Identification ..................................................... 9
Installation ......................................................12
Maintenance ............................................. 14, 15
Measuring Systems and Resolutions.....................8
Operating area ............................................... 12
Operational safety ............................................. 4
Order reference.................................................9
Packaging material............................................ 6
Pin assignment with 9 pin D-SUB connector
(Option D1) ................................................ 13
Pin assignment with open cable ends (standard). 13
Power Supply Voltages and Output Levels............ 8
Product features ................................................ 7
Protection against contact ................................ 12
Protective equipment ......................................... 5
Pulse diagram ................................................... 8
Resistance against Chemical Influence .............. 11
Safety ........................................................... 4, 5
Safety instructions .............................................. 4
Safety rules ....................................................... 4
Start-up .......................................................... 12
Storage ............................................................ 6
Technical Data Magnetic Tape ......................... 11
Technical Data PMIX........................................ 10
Transport.......................................................... 6
Transport damage ............................................. 6
Type designation ......................................... 9, 16
Typical Applications........................................... 7

- 20 -
Document- No.:
799000215 / Rev. 0
Document- Name:
PMIX-000-MA-E_20-19
Subject to change - © 2019
ELGO Electronic GmbH & Co. KG
ELGO Electronic GmbH & Co. KG
Measuring | Positioning | Control
Carl - Benz - Str. 1, D-78239 Rielasingen
Fon:+49 (0) 7731 9339-0, Fax:+49 (0) 7731 28803
Internet: www.elgo.de, Mail: info@elgo.de
This manual suits for next models
1
Table of contents
Other ELGO Electronic Media Converter manuals

ELGO Electronic
ELGO Electronic GMIX2 Series User manual

ELGO Electronic
ELGO Electronic LIMAX02 Series User manual

ELGO Electronic
ELGO Electronic EMSC2 Series User manual

ELGO Electronic
ELGO Electronic FMax Series User manual

ELGO Electronic
ELGO Electronic EMAX-RO Series User manual

ELGO Electronic
ELGO Electronic GMIX1A Series User manual