1000004005 (Rev. A - 08/2017)
ECP8_2HWR
PAGE 3
1. Temperature Control: Factory set for 50ºF ± 5º (10ºC ± 2.8º) water under normal conditions. To adjust water temperature, turn off electrical supply,
remove front panel using a 5/16" (7.9mm) socket wrench or at head screwdriver, and turn screw on cold control (Item 9) clockwise for colder, counter
clockwise for warmer.
Service: Adjustments
Service: Inspection/Cleaning
• Inspect Water Chiller twice each year for proper operation and performance.
• Inspection of the unit will require disconnecting electrical supply, removal of panels, etc. and reassembly and return to service practices.
1. Condenser Fan Motor: Conrm condenser fan turns freely. If the condenser fan does not spin freely, have an authorized service personnel replace.
2. Ventilation: Cabinet louvers and condenser ns should be periodically cleaned with a brush, air hose or vacuum cleaner. Cleaning should be done
twice each year or more frequently if needed due to environment. Excess dirt or poor ventilation can cause no cold water and compressor cycling
on the compressor overload protector.
3. Water Flow: Conrm proper water ow. If water ow is slow, inspect lter or inline strainer for restriction. Replace lter cartridge if required. Disassemble
inline strainer and clean if required. See Figure 3.
4. Lubrication: Motors are lifetime lubricated.
5. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring seal. To remove tubing from the
ttings, relieve water pressure and push in on gray collar while pulling on the tubing. To insert tubing, push tube straight into tting until it reaches a
positive stop, approximately 3/4" (19mm). See Figure 4.
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE
WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: All correspondence pertaining to any of the above water cooler or
orders for repair parts MUST include model number and serial number of
cooler, name and part number of replacement part.
For Replacement Parts, contact your local distributor or call 1.800.834.4816
Elkay Manufacturing Co. 2222 Camden Court – Oak Brook, IL 60523 U.S.A – 630.574.8484
Service
• Safety Glasses
• Protective gloves
• 5/16” (8mm) Hex Socket or Flathead Screwdriver
For proper and safe servicing, please read these instructions completely.
DANGER
• All Service and Maintenance must be performed by an authorized service personnel.
• Disconnect electrical supply to the unit before any service work to reduce risk of electrocution.
• Shut off water supply serving the unit before any service work to reduce risk of water damage.
CAUTION
• Tools/Items required but not provided, for Servicing:
REPLACEMENT PARTS LIST
ITEM NO. PART NO. DESCRIPTION
1 1000004316 KIT - EVAPORATOR REPLACE ASSY
2 0000000244 KIT - FAN MOTOR/BLADE//NUT/SHROUD
3 98778C KIT - HEATX/DRIER
4 1000004069 STRAINER
5 98773C KIT - COLD CONTROL/SCREWS
6 1000002147 COMPRESSOR SERV. PAK
7 98751C KIT - ELECT/RELAY/COVER/OVERLOAD
8 31506C POWERCORD
9 98777C KIT - COMPR MTG/GROMMETS/CLIPS/STUDS
10 98776C KIT - CONDENSER/DRIER
11 66703C DRIER
12 20282C BRACKET - FAN MTG
13 56237C SHROUD-FAN
*
3
1
2
4
5
6
7
8
9
10
11
12
13