manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Elko
  6. •
  7. Network Hardware
  8. •
  9. Elko ELKOLink User manual

Elko ELKOLink User manual

Popular Network Hardware manuals by other brands

socomec SNMP Card II quick start guide

socomec

socomec SNMP Card II quick start guide

NVR SYSTEMS 4-CH user manual

NVR SYSTEMS

NVR SYSTEMS 4-CH user manual

Draytek VigorSwitch G1240 quick start guide

Draytek

Draytek VigorSwitch G1240 quick start guide

Westermo TD-34 LV installation manual

Westermo

Westermo TD-34 LV installation manual

LaCie Network Space MAX Quick install guide

LaCie

LaCie Network Space MAX Quick install guide

ZoneVu ZSI-450-IP Installation guide & user manual

ZoneVu

ZoneVu ZSI-450-IP Installation guide & user manual

QNAP Turbo NAS Application notes

QNAP

QNAP Turbo NAS Application notes

OpenEye MV Series quick start guide

OpenEye

OpenEye MV Series quick start guide

Huawei SmartAX MT880a quick start guide

Huawei

Huawei SmartAX MT880a quick start guide

Proxim Tsunami QuickBridge 2454-R installation guide

Proxim

Proxim Tsunami QuickBridge 2454-R installation guide

Bay Networks CLAM quick start guide

Bay Networks

Bay Networks CLAM quick start guide

Innodisk SATADOM-SH 3SE Series manual

Innodisk

Innodisk SATADOM-SH 3SE Series manual

Cisco CGR 1000 Series Getting connected guide

Cisco

Cisco CGR 1000 Series Getting connected guide

Matrix Switch Corporation MSC-HD161DEL product manual

Matrix Switch Corporation

Matrix Switch Corporation MSC-HD161DEL product manual

National Instruments NI 653x user manual

National Instruments

National Instruments NI 653x user manual

B&B Electronics ZXT9-IO-222R2 product manual

B&B Electronics

B&B Electronics ZXT9-IO-222R2 product manual

Yudor YDS-16 user manual

Yudor

Yudor YDS-16 user manual

D-Link ShareCenter DNS-320L datasheet

D-Link

D-Link ShareCenter DNS-320L datasheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

NB010
06.08.01
Rev.3.2
MPT
EIA/TIA 568B
Koblingsskjema
Wiring diagram
Kopplingsschema
Kytkentäohje
Monteringsanvisning
Installation guide
Asennusohje
ELKO AS, Postboks 234, 1301 Sandvika, Tlf: +(47) 67 80 73 00 Faks:+ (47) 67 80 73 01
ELKO AB, Box 47020, 100 74 Stockholm, Tel. +(46)08 449 27 00, Fax. +(46) 08 449 27 30
ELKO SUOMI OY Olarinluoma 16 02200 ESPOO Tel:+(358) 09 4393210 Fax: +(358) 09 43932120
ELKO AS, Postboks 234, 1301 Sandvika, Tlf: +(47) 67 80 73 00 Faks: +(47) 67 80 73 01
ELKO AB, Box 47020, 100 74 Stockholm, Tel. +(46)08 449 27 00, Fax. +(46) 08 449 27 30
ELKO SUOMI OY Olarinluoma 16 02200 ESPOO Tel:+(358) 09 4393210 Fax: +(358) 09 43932120
19” Modular Patch Panels Kat-5 / Kat-6
10” Mini Patch Panel Kat-5 / Kat-6
19” Modular Patch Panels Cat-5 / Cat-6
10” Mini Patch Panel Cat-5 / Cat-6
19” Ristikytkentäpanelit Cat-5 / Cat-6
10” Ristikytkentäpanelit Cat-5 / Cat-6
www.elko.no
www.elko.no
EIA/TIA 568A
Par
Pair
Norsk
Farge
English
Colour
Svensk
Färg
Suomi
Värit
PIN
No.
1Hvit/Blå
Blå
White/Blue
Blue
Vit/Blå
Blå
Valk/Sininen
Sininen
5
4
2Hvit/Oransje
Oransje
White/Orange
Orange
Vit/Orange
Orange
Valk/Oranssi
Oranssi
1
2
3Hvit/Grønn
Grønn
White/Green
Green
Vit/Grön
Grön
Valk/Vihreä
Vihreä
3
6
4Hvit/Brun
Brun
White/Brown
Brown
Vit/Brun
Brun
Valk/Ruskea
Ruskea
7
8
12345678
Par
Pair
Norsk
Farge
English
Colour
Svensk
Färg
Suomi
Värit
PIN
No.
1Hvit/Blå
Blå
White/Blue
Blue
Vit/Blå
Blå
Valk/Sininen
Sininen
5
4
2Hvit/Grønn
Grønn
White/Green
Green
Vit/Grön
Grön
Valk/Vihreä
Vihreä
1
2
3Hvit/Oransje
Oransje
White/Orange
Orange
Vit/Orange
Orange
Valk/Oranssi
Oranssi
3
6
4Hvit/Brun
Brun
White/Brown
Brown
Vit/Brun
Brun
Valk/Ruskea
Ruskea
7
8
12345678
Norsk English Svensk Suomi
PIMF
S-FTP
Fig. 1: Preparing the cable
All cable types
Remove the outer jacket of the cables by minimum
60 mm.
PIMF and S-FTP cables
Straighten and separate the braid from the pairs.
Twist the braid rmly around the end of the outer
jacket.
Cut the foils around the individual pairs (PIMF), or
cut the common foil (S-FTP) close to the end of the
outer jacket.
FTP cables
Twist the exposed drain wire tightly around the
exposed foil close to the end of the outer jacket.
Fig. 2: Cable termination
Place the prepared cables under the screen clamp.
By screened cables, place the exposed and prepa-
red screen under the clamp
Tighten the nger screw.
Place the individual wires in correct positions on the
LSA plus IDC. Follow the color coding on the LSA
Plus.. Make sure that each individual pair has not
been untwisted more than 13 mm.
Terminate the pairs using a Krone LSA Plus tool.
Fig. 3
Use cable strips to strain relief the cables at the rear
end of the panel By panels for screened cables, put
on the panel screen cover.
Fig. 1: Forberede kabelen
Alle kabelyper
Fjern ytterkappen på kabelen minimum 60 mm.
PIMF og S-FTP kabler
Rett ut og skill ettingen fra parene.
Tvinn ettingen tett rundt enden av ytterkappen.
Kutt den synlige folien rundt hvert par (PIMF)
eller den felles folien (S-FTP) rett ved enden av
ytterkappen.
FTP kabler
Tvinn jord-tråden tett rundt den synlige folien rett
ved enden av ytterkappen.
Fig. 2: Terminering
Plasser de ferdig forberedte kablene under skjerm-
klemmen på panelet.
Ved skjermede kabler er det viktig at den synlige
delen av den ettede kabelskjermen blir liggende
under skjermklemmen.
Skru til ngermutteren med ngrene.
Plasser de enkelte lederne på rett plass i LSA
Plus knivkontaktene. Følg fargekoden på knivkon-
taktene nøye.
Sjekk at ingen par er tvunnet opp mer enn 13 mm.
Terminer parene med et Krone LSA Plus verktøy.
Fig. 3
Bruk kabelstrips til å strekkavlaste kablene bakerst
på panelet. Ved paneler for skjermede kabler må
skjermlokket settes på til slutt.
Fig. 1: Förbered kabeln
För alla kabeltyper
Ta bort yttermanteln på kabeln minimum 60 mm.
PIMF och S-FTP kablar
Räta ut och skilj ätningen från paren.
Tvinna ätningen runt änden av manteln.
Ta bort den synliga folien runt varje par (PIMF) eller
den gemensamma folien (S-FTP) vid änden av
manteln.
FTP kabler
Tvinna jordtråden runt den synliga folien vid änden
av manteln.
Fig. 2: Kontaktering
Placera de preparerade kablarna under skärmkläm-
man på panelen.
Med skärmade kablar är det viktigt att den synliga
delen av den ätade kabelskärmen kommer under
skärmklämman.
Skruva till muttern med ngrarna.
Placera ledarna i LSA+ kontakterna och följ färg-
koden.
Maximal upptvinning av ledarna i varje par är 13mm.
Kontaktera paren med ett Krone LSA Plus verktyg.
Fig. 3
Använd buntband till att få ordning på kablarna i
bakkant på panelen. Med paneler för skärmade
kablar måste skärmlocket användas.
Kuva 1: Kaapelin käsittely
Kaikki kaapelityypit
Kuori kaapelin ulkovaippaa vähintään 60 mm
PIMF ja S-FTP tyyppiset kaapelit
Suorista ja irroita suojavaippa johtimista.
Käännä suojavaippa tiukasti kaapelin ulko-
vaipan ympäri.
Katkaise folio yksittäisten parien ympäriltä
(PIMF), tai katkaise suojafolio (S-FTP) läheltä
kaapelin ulkovaippaa.
FTP-kaapelit
Käännä sekä suojafolio että punattu suoja tiu-
kasti kaapelin ulkovaipan ympäri.
Kuva. 2: Kaapelin päättäminen
Laita kaapelin ulkovaippa vedonpoistimen alle,
Suojatuissa kaapeleissa varmista että suojafolio
sekä punottu suoja ovat vedonpoistimen alla
Kiristä vedonpoistimen.
Sijoita yksittäiset johtimet oikeille paikoilleen
LSA-rimalle. Katso värikoodit sivulta 1. Varmis-
ta että minkään yksittäisen parin parikierrettä ei
avattu enempää kuin 13mm (Cat5e) ja n.6mm
(Cat6). Kiinnitä kaapelit hahloihinsa LSA PLUs
työkalulla.
Kuva 3:
Käytä nippusidettä kiinnittääksesi kaa-
peli paneelin takaosaan. Suojatussa mallissa
asenna suojkansi myös paikoilleen.
Fig. 2 Fig. 3
FTP
UTP
Fig. 1