ELNet GR/PQ User manual

Installation & Operation Manual
Elnet
GR\PQ
Electrical Measurements & Power
Quality
Ver. 1.8

2
Table of Contents
CHAPTER 1 ─ INTRODUCTION .......................................5
1.1
About the ElNet Meter .................................5
1.2
How to use this anual ..................................6
1.3
Safety Infor ation ..........................................8
1.4
Warranty .........................................................9
1.5
Your co ents are welco e ........................ 11
1.6
Disclai er ...................................................... 12
CHAPTER 2 — INSTALLATION ...................................... 13
2.1
Contents of packaging .................................. 14
2.2
Mechanical ounting ................................... 15
2.3
Wiring Sche atics ........................................ 17
2.4
Rear Panel Connections ............................... 21
2.5
Digital Outputs and Inputs. ......................... 26
2.6
Manufacturing Data. .................................... 27
CHAPTER 3 — USING THE ElNet Meter ...................... 28
3.1
Front Panel .................................................... 28
3.2
Control Buttons ............................................. 29
3.3
Lock Utility ................................................... 30
CHAPTER 4 — NECESSARY ElNet SETTINGS ........... 32
4.1
Settings for Current Transfor er ............... 33

3
4.2
Electrical Connection Check........................ 36
4.3
TOU Setting................................................... 39
4.4
Change language ........................................... 40
4.5
Ti e Settings ................................................. 41
4.6
Date Settings.................................................. 42
4.7
Setting digital out .......................................... 43
4.8
Delta/Star Electrical network definition ..... 44
4.9
De and Setting. ............................................ 45
CHAPTER 5 — FRONT PANEL DISPLAYS .................... 4
5.1
Current for 3 Phases ..................................... 46
5.2
Frequency for 3 Phases ................................. 47
5.3
Current in Neutral Line ............................... 48
5.4
Voltage for 3 Phases ...................................... 49
5.5
Active Power for all 3 Phases (P) ................. 50
5.6
Reactive Power for all 3 Phases (Q) ............ 52
5.7
Apparent Power for all 3 Phases (S) ............ 53
5.8
Power Factor for each Phase ........................ 54
5.9
Overall Power Factor ................................... 55
5.10
Active/ Reactive/ Apparent Energy ............. 56
5.11
Power Quality ............................................... 57
5.11.1
Wave For Graphs ...................................... 57
5.11.2
Har onics Bar Graphs ................................ 59

4
5.11.3
Voltage Total Har onic Distortion (THD). 61
5.11.4
Current Total Har onic Distortion (THD) 62
5.11.5
Current THD,TDD,KF ................................. 63
5.11.6
EN50160 event onitoring and Wave
records ........................................................... 64
5.11.7
Long PQ event special record ..................... 66
CHAPTER — ALARM REPORT .................................... 70
6.1.
Alar setting ................................................. 71
6.2.
Display Alar s Report ................................. 73
6.3.
Display EN50160 Event Report ................... 74
CHAPTER 7 — DEMAND REPORTS .............................. 75
CHAPTER 8 — DATA LOGGING ..................................... 7
CHAPTER 9 — COMMUNICATION ................................ 79
9.1
Co unication Connections ....................... 79
9.2
Co unication Settings .............................. 79
9.3
Address .......................................................... 79
9.4
Baud Rate ...................................................... 80
9.5
Parity ............................................................. 80
9.6
Co unication Set Up ................................ 81
9.7
Co unication with UniArt Software ....... 84
CHAPTER 10 — Specifications ......................................... 8
10.1
Measure ent & Display ............................... 87
Appendix A — Installation & Configuration Check List ... 89

5
CHAPTER 1 ─ INTRODUCTION
1.1 About the ElNet Meter
Large consumers of electricity e.g. factories, hotels, hospitals,
municipalities, need to know the history of their consumption and
the quality of the power supply. Details such as Voltage, Current,
Power Factor, Hert , Neutral Current, Energy Demands and all
electricity related events are recorded in the
ElNet
Energy &
Powermeter.
An additional feature of the Meter is the ability to measure
Harmonics. Part of the Electricity Supply Authority’s bill reflects
poor or good Harmonics in the consumer’s system, therefore it is
in his interest to monitor Harmonics and try to improve it.
These are all recorded on a continual basis and can be recalled
and shown on the front panel display of the instrument with a few
simple key-strokes any time the user wishes.
The
ElNet
Energy & Powermeter is a compact, multi
functional, three-phase Meter simple to install and is especially
designed to integrate into Building Management Systems. It
requires no special mounting and is ideally suited for mounting on
the front face of any standard electrical panel.
The Configuration and Setup is menu driven, with password
protection.
Communication with external devices is simple and is based on
standard known technology.
The
ElNet
Energy & Powermeter boasts a new innovative
built in “Flash Memory”, which pioneers a new frontier into
electrical measurement. It has a 1 MB of FLASH MEMORY with
a capacity of recording up to 2 years of power malfunctions and
interruptions.

6
Readings, graphs, tables & history are shown on the graphic
display of the
ElNet
Energy & Powermeter
.
This display is
a state of the art screen with a resolution of 160X128.
Each
ElNet
Energy & Powermeter is carefully and
meticulously manufactured using quality components and the
latest production methods. Before leaving the factory each
ElNet
Energy & Powermeter is calibrated and sent to the
customer accompanied by the test certificate and Certificate of
Compliance (C.O.C).
1.2 How to use this manua
We at CONTROL APPLICATIONS Ltd, envisage this manual to
be used by three types of people, i.e. the Installation Technician,
the Senior Electrical Engineer and the end User. For this reason
this manual is divided into chapters for ease of reference by each
of these different people. There could be a situation where two of
the abovementioned tasks can be combined, or in a rare instance
one person could handle all three tasks.
CHAPTER 1, Introduction, describes the
ElNet
Energy &
Powermeter
,
its potential users, the readings it can provide and
some of its features in brief.
CHAPTER 2, Installation, provides detailed instructions for
unpacking, mechanical mounting, and electrical wiring up
instructions for the Installation Technician.
CHAPTER 3, Using the
ElNet
Energy & Powermeter,
describes in detail front Panel, the functions of the control
buttons, and the Lock Utility.

7
CHAPTER 4, Parameter Configuration & Settings explains in
detail the minimum parameters settings needed by the Senior
Electrical Engineer to set up and configure the
ElNet
Energy
& Powermeter.
CHAPTER 5, Front Panel Displays, is an easy to follow step-by-
step guide to obtain readings, graphs, tables and histories for the
User.
CHAPTER 6, Alarm reports gives details about how to program
the Alarms in the
ElNet
Energy & Powermeter.
CHAPTER 7, Demand reports is an easy to follow step-by-step
guide to obtain the Demand reports up to 2 years.
CHAPTER 8, Data Logging is an easy to follow step-by-step
guide to obtain all the stored peaks of current, voltage, energy,
power factor etc. up to 2 years of data logging.
CHAPTER 9, Communications gives details about the
Communication capabilities of the
ElNet
Energy &
Powermeter, and how to Set Up.
CHAPTER 10, Specifications, is a detailed list of specifications of
the
ElNet
Energy & Powermeter
.
APPENDIX A, Installation & Configuration Check List, provides
a Check List to insure no important steps will be missed during
the initial set up.

8
1.3 Safety Information
The purpose of this manual is to help you. Please read the
instructions carefully before performing any installation and note
any precautions.
• Ensure that all incoming AC power and other power
sources are turned off before performing any work on
the
ElNet
Energy & Powermeter
.
Failure to do so
may result in serious or even fatal injury and/or
equipment damage.
• If the
ElNet
Energy & Powermeter is damaged in
any way do NOT connect it to any power source.
• To prevent a potential fire or shock ha ard, never expose
the
ElNet
Energy & Powermeter to rain or
moisture.
• Keep the surrounding area free of dirt and clutter
especially metal objects. Good housekeeping pays.
• Inspect the cables periodically for cracks, kinks or any
other signs of wear
• Keep children away.
• Do not pull the cords.
• Users should stay alert and not approach the rear of the
ElNet
Energy & Powermeter while tired or under
the influence of alcohol, medicines or any other
chemical substance that would tend to make a person
drowsy.
• Do not wear loose clothing or dangling jewelry.
• Above all use common sense at all times.
WARNING

9
1.4 Warranty
CONTROL APPLICATIONS Ltd provides a 12- Month warranty
against faulty workmanship or components from date of dispatch
provided that the product was properly installed and used.
CONTROL APPLICATIONS Ltd does not accept liability for any
damage that may be caused by natural disasters (such as floods,
fire, earthquake, lightening etc.).
CONTROL APPLICATIONS Ltd does not accept liability for any
damage that may be caused by malfunction of the
ElNet
Energy & Powermeter
.
CONTROL APPLICATIONS Ltd will advise the customer on the
proper installation and use of the
ElNet
Energy &
Powermeter
,
but will not accept any responsibility that the
instrument is suitable for the application for which it was
originally purchased.
This warranty may become void if the Installation, Parameter
Configuration & Setting Instructions are not carried out according
to the instructions set out by CONTROL APPLICATIONS Ltd.
The
ElNet
Energy & Powermeter has no user serviceable
parts and should be opened and serviced by a duly qualified
authori ed representative only. The sensitive electronics could
become damaged if exposed to a static environment. This action
would void the warranty.

10
This warranty is limited to the repair and/or replacement at
CONTROL APPLICATION Ltd sole discretion of the defective
product during the warranty period. Repaired or replaced products
are warranted for ninety (90) days from the date of repair or
replacement, or for the remainder of the original product’s
warranty period, whichever is longer.
CONTROL APPLICATIONS Ltd is always at your service to
advise the customer on any problem that may be encountered
regarding any installation, operation, parameter & configuration
settings or maintenance.

11
1.5 Your comments are we come
CONTROL APPLICATIONS Ltd. sincerely thanks you for
choosing our
ElNet
Energy & Powermeter
.
We are
confident that it will
provide you with many years of trouble free
service and give you all the power and energy information and
history that you expected from the instrument when you bought it.
While every effort was made to keep the information as reliable,
helpful, accurate and up to date as possible, all possible
contingencies cannot be covered. Technical or typographical
errors could occur, and we would be happy to receive any
comments, criticisms or notifications of any such errors from you,
our valued customer.
Address: FENIKS PRO d.o.o.
Zagrebška cesta 90
2000 Maribor
Slovenia
EUROPE
Tel: 02 460 22 58
Fax: 02 460 22 56
Electronic Address: info@feniks-pro.eu

12
1.6 Disc aimer
Information in this User Manual is subject to change without
notice and does not represent a commitment on the part of
CONTROL APPLICATIONS Ltd.
CONTROL APPLICATIONS Ltd supplies this User Manual as is
without warranty of any kind; either expressed or implied, and
reserves the right to make improvements and/or changes in the
manual or the product at any time.
While it is the intention of CONTROL APPLICATIONS Ltd to
supply the customer with accurate and reliable information in this
User Manual, CONTROL APPLICATIONS Ltd assumes no
responsibility for its use, or for any infringement of rights of the
fourth parties which may result from its use.
This User Manual could contain technical or typographical errors
and changes are periodically made to the information herein;
these changes may be incorporated in new editions of the
publication.

13
CHAPTER 2 — INSTALLATION
In this Chapter you will find the information and instructions that
the Installation Technician needs, to mount and connect the
ElNet
Energy & Powermeter
• During operation, ha ardous voltages are present
in connecting cables and terminal blocks.
• Fully qualified personnel must do all work. Failure
to follow this rule may result in serious or even
fatal injury to personnel and/or damage to
equipment.
• Refer to Section 1.3 Safety information before
carrying out any installation.
• Read this manual thoroughly and make sure you
understand the contents before connecting the
ElNet
Energy & Powermeter to any power
source.
WARNING!

14
2.1 Contents of packaging
The
ElNet
Energy & Powermeter
is packed and shipped in
a carton approximately 24.5 cm long X 19 cm wide X 12 and cm
high.
Before opening the package, ensure the area, clean and dry.
Without using any sharp instruments, carefully open the carton of
the
ElNet
Energy & Powermeter
.
Please check the contents of the carton, it should contain:
Elnet GR Elnet PQ
1. Your new Elnet Energy &
Powermeter
Your new Elnet Energy &
Powermeter
2. Elnet GR/PQ User Manual
(this book)
Elnet GR/PQ User Manual
(this book)
3. Test Certificate and
Certificate of Compliance
(C.O.C).
Test Certificate and
Certificate of Compliance
(C.O.C).
4. A pair of Panel mounting
clips.
A pair of Panel mounting
clips.
5. 1 X two pole connector
plug.
2 X two pole connector
plug.
6. 1 X three pole connector
plug.
1 X Four pole connector
plug.
7. 1 X Four pole connector
plug.
1 X Five pole connector
plug.
8. 1 X Five pole connector
plug.

15
2.2 Mechanica mounting
To Mount the
ElNet
Energy & Powermeter
Choose a suitable location, and prepare a rectangular hole
according to the dimensions shown in Figure 2.1
Figure 2.1. Panel Cutout
Do not mount the
ElNet
Energy &
Powermeter too close to any main electrical
conductors.
Allow sufficient space to carry out
maintenance to the back of the
ElNet
Energy & Powermeter
NOTE!
!
Width
138 mm
Height
138 mm

16
• Slide the
ElNet
Energy & Powermeter
into the pre-prepared
rectangular hole (ensure
it is the right way up), then
push the two
mounting clips provided in the packaging into
position. Use mild force to ensure the clips are
securely positioned on the outer case of the
ElNet
Energy & Powermeter
.
• Tighten the two mounting screws and ensure
the
ElNet
Energy & Powermeter is
firmly in place.
Figure 2.2. Mounting Clips
1
2
3

17
2.3 Wiring Schematics
To wire up the
ElNet
GR Energy & Powermeter in "Star"
connection:
Figure 2.3. GR Sche atic "Star" Wiring Diagra

18
To wire up the
ElNet
GR Energy & Powermeter in "Delta"
connection:
Figure 2.4. GR Sche atic "Delta" Wiring Diagra

19
To wire up the
ElNet
PQ Energy & Powermeter in "Star"
connection:
Figure 2.5. PQ Sche atic "Star" Wiring Diagra

20
To wire up the
ElNet
PQ Energy & Powermeter in "Delta"
connection:
Figure 2.6. PQ Sche atic "Delta" Wiring Diagra
Table of contents
Other ELNet Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

CS Instruments
CS Instruments FA 410 instruction manual

Protimeter
Protimeter MMS2 instruction manual

PCB Piezotronics
PCB Piezotronics 353B77 Installation and operating manual

HK Instruments
HK Instruments DPG Series installation instructions

Agilent Technologies
Agilent Technologies U1731C user guide

Bosch
Bosch DLE 40 Professional Original instructions

Precision Digital Corporation
Precision Digital Corporation PD6928 instruction manual

Smart Caregiver
Smart Caregiver TL-2015R2 Installation and use instructions

Mollet
Mollet LF20 Series Operating instruction

Spectroline
Spectroline OIL-GLO ULTRA instruction manual

Keysight
Keysight PNA-X Series Configuration guide

Abtus