Energy Star 197E3LSU 00 AP User manual

Description Page
Important Safety Notice--------------------------------------2
Technical Data--------------------------------------------- ----3
Installation-------------------------------------------------------6
On Screen Display----------------------------------------9~10
Lock/unlock, Aging,Factory mode-------------------------11
---------------------------------12
Mechanical Instructions ------------------------------13~15
Color adjustment --------------------------------------------16
Electrical instruction ----------------------------------19~20
DDC Instructions & Serial Number -----------------23~29
DDC DATA -----------------------------------------------30~31
------------------------32~33
Philips Pixel Defect Policy
FAQs (Frequently Asked Questions)---------------17~18
Firmware Upgrade for CPU-
Horizontal frequencies
30 - 83 kHz
TABLE OF CONTENTS
Description Page
-----------------------------------34
Wiring Diagram----------------------------------------------35
Block Diagram------------------------------------------------36
Power
Control Diagram & C.B.A. -----------------------------48~49
Failure Mode Of Panel -
SAFETY NOTICE
Chassis:
18.5W
REFER TO BACK COVER FOR IMPORTANT SAFETY GUIDELINES
ANY PERSON ATTEMPTING TOSERVICE THIS CHASSIS MUST FAMILIARIZE HIMSELF WITH THE CHASSIS
AND BE AWARE OF THE NECESSARY SAFETY PRECAUTIONS TO BE USED WHEN SERVICING ELECTRONIC
EQUIPMENT CONTAINING HIGH VOL TAGES.
CAUTION: USE A SEPARATE ISOLATION TRANSFORMER FOR THIS UNIT WHEN SERVICING.
Published by Philips Consumer Lifestyle Copyright reserved Subject to modification JJun 23 2011
Scaler Diagram & C.B.A. ------------------------------37~42
GB
MERIDIAN 3
Troubleshooting---------------------------------------------7~8
Service Tool-----------------------------------------------21~22
inch FHD
General product specification------------------------50~73
Exploded View -----------------------------------------------74
Spare/ arts List-------------------------75
Recommended P
PCBA photos---------------------------------------------------76
Repair tips-------------------------------------------------77~78
Repair Flow chart----------------------------------------79~80
Safety Test Requirments------------------------------------81
LCD Colour Monitor
TFT
Diagram & C.B.A. -------------------------43~45
LED Diagram & C.B.A.----------------------------------46~47
Auto Color & User reset --------------------------------82~83
197E3LSU/00
197E3LSU/01
197E3LSU/27
197E3LSU/75
197E3LSU/69
197E3LSU/93
197E3LSU/00(AP) 197E3LSU/62
197E3LSU/70
197E3LSU/71
197E3LSU/73
197E3LSU/94
197E3LSU/96
197E3LSU/67

Important Safety Notice
Proper service
operation of all Philips Consumer Electronics Company
equipment. The service procedures recommended by Philips and
described in this service manual a re effective methodsof
performing service operations .Some of these service
operations require the useof tools speciall y desi gned for the
purpose. The special tools should be used when and as
recomm ended.
It is im portant to note that this m anual c ontains various
CAUTI ONSand NOTICESwhich should becarefully read in
order to m inimize the risk of personal injury to service
personnel . The possibility exists that improper service
methods may damage the equipment . It is also important to
underst and that these CAUTIONSand NOTICESARE NOT
EXHAUSTIVE. Philips could not possibly know, evaluate and
advise the servic etrade of all conceivable ways i n which
service might be done or of the possible hazardous
consequences of each way. Consequently, Philips has not
undertaken any such broad evaluation. Accordingly,
who uses a servi ce procedure or tool which is not
recommended by Philipsmust first satisfy himself thoroughly that
neither his safety nor the safeoperation of the equipment will
be jeopardized by the service method select ed.
* * Hereafter throughout this manual, PhilipsConsumer
Electronics Company will be referred to as Philips.**
Critical components having special safety characteristics are
identified with a by the Ref. No. in the parts list and
enclosed within a broken line
(where several critical components are grouped in one area)
along with the safety symbol on the schematics or
exploded views.
Use of substitute replacement parts which do not have the
same speci fied safety characteristics may create shock, fire,
or other hazards .
Under no circumstances should the original design be
modified or altered without written permission from Philips.
Philips assumes no liability, express or implied, arising out of
any unauthorized modification of design.
Servicer assumes all liability.
WARNING
Take care during handling the LCD module with backlight
unit
- Must mount the module using mounting holes arranged in four
corners.
- Do not press on the panel, edge of the frame strongly or electric
shock as this will result in damage to the screen.
- Do not scratch or press on the panel with any sharp objects, such
as pencil or pen as this may result in damage to the panel.
- Protect the module from the ESD as it may damage the electronic
circuit (C-MOS).
-Make certain that treatment body are grounded through
wrist band.
- Do not leave the module in high temperature and in areas of high
humidity for a long time.
- Avoid contact with water as it may as hort circuit within the module.
-If the surface of panel become dirty, please wipe it off with a soft
material. (Cleaning with a dirty or rough cloth may damage the
panel.)
FOR PRODUCTSCONTAINING LASER :
DANGER - Invisible laser radiation when open.
AVOID DIRECT EXPOSURE TO BEAM.
CAUTION - Use of controls or adjustments or
performance of procedures other than
those specified herein may result in
hazardous radiation exposure.
CAUTION - The use of optical instruments with this
product will increase eye hazard.
TO ENSURE THE CONTINUED RELIABILITY OF THIS
PRODUCT,USE ONLYORIGINAL MANUFACTURER'S
REPLACEMENT PAR TS, WHICH ARE LISTED WITH THEIR PART
NUMBERSIN THE PARTSLISTSECTION OF THIS
SERVICE MANUAL.
and repair is important to the safe, reliable
2 197E3L LCD

197E3L LCD 3
Technical Data
CMI
Type NR. : CMI M1845BGE L10
Resolution : 1366x768
Outside dimensions : 430.37(H) x 254.6(V) x 10.5(D) mm
Pitch (mm) : 0.3mm x 0.3mm
Color pixel arrangement : 1366 horizontal By 768 vertical Pixels.
RGB stripe arrangement
Display surface : Hard coating (3H), Anti-glare
treatment of the front polarizer
Color depth : 16.7 M colors 6-bit with H-FRC
Backlight : WLED
Active area (W x H) : Vertical 409.8mm x Horizontal
230.4mm
View angle (CR=10) : >=160 for Right/Left (Typ)
: >=160 for Up/Down (Typ)
Contrast ratio : 1000:1(Typ.)
White luminance : 250 nit(Typ.)
Color gamut : >=72%
GateIC :LDI
SourceIC :N/A
Responsetime :5ms
Vertical frequency range : 47~75 H z
Scanning frequencies
Hor.: 30 – 83 K Hz
Ver.: 56 - 76 Hz
Video dot rate: < 165 MHz for VGA and < 165 MHz for DVI(Scaler
IC limit)
Power input: 90-264 V AC, 50/60 r2 Hz
Power consumption: Normal on:
On mode: < 18W (max.), 14W (typ.)
EPA 5.0 spec. < 16.6 watt
EPA 5.0 measure data < 16.6 watt
Functions:
(1) D-SUB analog R/G/B separate inputs, H/V sync separated,
Composite (H+V) TTL level, SOG sync.
(2) DVI digital Panel Link TMDS inputs, HDCP supported.
Ambient temperature: 0
q
C - 40
q
C
Power input connection
Power cord length : 1.5 M
Power cord type : 3 leads power cord with protective earth plug.
Power management
Mode HS
YN
C
VSYN
C
Video Pwr-cons. Indica
tion
Rec.
time
Power-On On On Active
<14W (typ.)
< 18W(max.)
EPA5.0<16.6W
White
LED --
Standby Off Off Blanked < 0.5W
Blinking
white LED
Period 3
sec on
3sec off
<3s
DC Power
Off
ʳʳ N/A < 0.5W LED Off ʳ
PIN No. SIGNAL PIN No. SIGNAL
1 Red 9 DDC +3.3V or +5V
2 Green/ SOG 10 Logic GND
3 Blue 11 Sense (GND)
4 Sense (GND) 12 Bi-directional data
5 Cable Detect (GND) 13 H/H+V sync
6 Red GND 14 V-sync
7 Green GND 15 Data clock
8 Blue GND ʳʳ
Susceptibility of display to external environment
Operating
- Temperature : 0 to 40 degree C
- Humidity : 80% max
- Altitude : 0-3658m
- Air pressure : 600-1100 mBAR
Storage
- Temperature : -20 to 60 degree C
-Humidity :95%max
- Altitude : 0-12192m
- Air pressure : 300-1100 mBAR
Note: recommend at 5 to 35qC, Humidity less than 60 %
Pin No. Description
1 T.M.D.S. data2-
2 T.M.D.S. data2+
3 T.M.D.S. data2 shield
4 No Connect
5 No Connect
6 DDC clock
7 DDC data
8 No Connect
9 T.M.D.S. data1-
10 T.M.D.S. data1+
11 T.M.D.S. data1 shield
12 No Connect
13 No Connect
14 +5V Power
15 Ground (for +5V)
16 Hot plug detect
17 T.M.D.S. data0-
18 T.M.D.S. data0+
19 T.M.D.S. data0 shield
20 No Connect
21 No Connect
22 T.M.D.S clock shield
23 T.M.D.S. clock+
24 T.M.D.S. clock-

197E3L LCD 4
Technical Data
AUO
Type NR. : AUO M185XW01 VD
Resolution : 1366x768
Outside dimensions : 430.4(H) x 254.6(V) x 9.9(D) mm
Pitch (mm) : 0.3mm x 0.3mm
Color pixel arrangement : 1366 horizontal By 768 vertical Pixels.
RGB stripe arrangement
Display surface : Hard coating (3H), Anti-glare
treatment of the front polarizer
Color depth : 16.7 M colors 6-bit with H-FRC
Backlight : WLED
Active area (W x H) : Vertical 409.8mm x Horizontal
230.4mm
View angle (CR=10) : >=160 for Right/Left (Typ)
: >=160 for Up/Down (Typ)
Contrast ratio : 1000:1(Typ.)
White luminance : 250 nit(Typ.)
Color gamut : >=72%
GateIC :LDI
SourceIC :N/A
Responsetime :5ms
Vertical frequency range : 47~75 H z
Scanning frequencies
Hor.: 30 – 83 K Hz
Ver.: 56 - 76 Hz
Video dot rate: < 165 MHz for VGA and < 165 MHz for DVI(Scaler
IC limit)
Power input: 90-264 V AC, 50/60 r2 Hz
Power consumption: Normal on:
On mode: < 18W (max.), 14W (typ.)
EPA 5.0 spec. < 16.6 watt
EPA 5.0 measure data < 16.6 watt
Functions:
(1) D-SUB analog R/G/B separate inputs, H/V sync separated,
Composite (H+V) TTL level, SOG sync.
(2) DVI digital Panel Link TMDS inputs, HDCP supported.
Ambient temperature: 0
q
C - 40
q
C
Power input connection
Power cord length : 1.5 M
Power cord type : 3 leads power cord with protective earth plug.
Power management
Mode HS
YN
C
VSYN
C
Video Pwr-cons. Indica
tion
Rec.
time
Power-On On On Active
<14W (typ.)
< 18W(max.)
EPA5.0<16.6W
White
LED --
Standby Off Off Blanked < 0.5W
Blinking
white LED
Period 3
sec on
3sec off
<3s
DC Power
Off
ʳʳ N/A < 0.5W LED Off ʳ
PIN No. SIGNAL PIN No. SIGNAL
1 Red 9 DDC +3.3V or +5V
2 Green/ SOG 10 Logic GND
3 Blue 11 Sense (GND)
4 Sense (GND) 12 Bi-directional data
5 Cable Detect (GND) 13 H/H+V sync
6 Red GND 14 V-sync
7 Green GND 15 Data clock
8 Blue GND ʳʳ
Susceptibility of display to external environment
Operating
- Temperature : 0 to 40 degree C
- Humidity : 80% max
- Altitude : 0-3658m
- Air pressure : 600-1100 mBAR
Storage
- Temperature : -20 to 60 degree C
-Humidity :95%max
- Altitude : 0-12192m
- Air pressure : 300-1100 mBAR
Note: recommend at 5 to 35qC, Humidity less than 60 %
Pin No. Description
1 T.M.D.S. data2-
2 T.M.D.S. data2+
3 T.M.D.S. data2 shield
4 No Connect
5 No Connect
6 DDC clock
7 DDC data
8 No Connect
9 T.M.D.S. data1-
10 T.M.D.S. data1+
11 T.M.D.S. data1 shield
12 No Connect
13 No Connect
14 +5V Power
15 Ground (for +5V)
16 Hot plug detect
17 T.M.D.S. data0-
18 T.M.D.S. data0+
19 T.M.D.S. data0 shield
20 No Connect
21 No Connect
22 T.M.D.S clock shield
23 T.M.D.S. clock+
24 T.M.D.S. clock-

197E3L LCD 5
Technical Data
Qisda
Type NR. :Qisda M185Q01
Resolution : 1366x768
Outside dimensions :430.4(H) x 254.6(V) x 9.6(D) mm
Pitch (mm) : 0.3mm x 0.3mm
Color pixel arrangement : 1366 horizontal By 768 vertical Pixels.
RGB stripe arrangement
Display surface : Hard coating (3H), Anti-glare
treatment of the front polarizer
Color depth : 16.7 M colors 6-bit with H-FRC
Backlight : WLED
Active area (W x H) : Vertical 409.8mm x Horizontal
230.4mm
View angle (CR=10) : >=160 for Right/Left (Typ)
: >=160 for Up/Down (Typ)
Contrast ratio : 1000:1(Typ.)
White luminance : 250 nit(Typ.)
Color gamut : >=72%
GateIC :LDI
SourceIC :N/A
Responsetime :5ms
Vertical frequency range : 47~75 H z
Scanning frequencies
Hor.: 30 – 83 K Hz
Ver.: 56 - 76 Hz
Video dot rate: < 165 MHz for VGA and < 165 MHz for DVI(Scaler
IC limit)
Power input: 90-264 V AC, 50/60 r2 Hz
Power consumption: Normal on:
On mode: < 18W (max.), 14W (typ.)
EPA 5.0 spec. < 16.6 watt
EPA 5.0 measure data < 16.6 watt
Functions:
(1) D-SUB analog R/G/B separate inputs, H/V sync separated,
Composite (H+V) TTL level, SOG sync.
(2) DVI digital Panel Link TMDS inputs, HDCP supported.
Ambient temperature: 0
q
C - 40
q
C
Power input connection
Power cord length : 1.5 M
Power cord type : 3 leads power cord with protective earth plug.
Power management
Mode HS
YN
C
VSYN
C
Video Pwr-cons. Indica
tion
Rec.
time
Power-On On On Active
<14W (typ.)
< 18W(max.)
EPA5.0<16.6W
White
LED --
Standby Off Off Blanked < 0.5W
Blinking
white LED
Period 3
sec on
3sec off
<3s
DC Power
Off
ʳʳ N/A < 0.5W LED Off ʳ
PIN No. SIGNAL PIN No. SIGNAL
1 Red 9 DDC +3.3V or +5V
2 Green/ SOG 10 Logic GND
3 Blue 11 Sense (GND)
4 Sense (GND) 12 Bi-directional data
5 Cable Detect (GND) 13 H/H+V sync
6 Red GND 14 V-sync
7 Green GND 15 Data clock
8 Blue GND ʳʳ
Susceptibility of display to external environment
Operating
- Temperature : 0 to 40 degree C
- Humidity : 80% max
- Altitude : 0-3658m
- Air pressure : 600-1100 mBAR
Storage
- Temperature : -20 to 60 degree C
-Humidity :95%max
- Altitude : 0-12192m
- Air pressure : 300-1100 mBAR
Note: recommend at 5 to 35qC, Humidity less than 60 %
Pin No. Description
1 T.M.D.S. data2-
2 T.M.D.S. data2+
3 T.M.D.S. data2 shield
4 No Connect
5 No Connect
6 DDC clock
7 DDC data
8 No Connect
9 T.M.D.S. data1-
10 T.M.D.S. data1+
11 T.M.D.S. data1 shield
12 No Connect
13 No Connect
14 +5V Power
15 Ground (for +5V)
16 Hot plug detect
17 T.M.D.S. data0-
18 T.M.D.S. data0+
19 T.M.D.S. data0 shield
20 No Connect
21 No Connect
22 T.M.D.S clock shield
23 T.M.D.S. clock+
24 T.M.D.S. clock-

6197E3L LCD
Installation
Front View Product Description
Rear View
ʳ
Accessory Pack
Unpack all the parts
Connecting to Your PC
1) Connect the power cord to the back of the monitor firmly.
(Philips has pre-connected VGA cable for the first installation.
ʳ

197E3L LCD 7
Troubleshooting
ʳ

8197E3L LCD
Troubleshooting

197E3L LCD 9
On-Screen Display
Description of the On Screen Display
ʳ
What is the On-Screen Display?
ʳ
On-Screen Display (OSD) is a feature in all Philips LCD monitors. It allows an end user to adjust screen performance or
select functions of the monitors directly through an on-screen instruction window. A user friendly on screen display
interface is shown as below :ʳ
ʳ
ʳ
Basic and simple instruction on the control keys.
ʳ
In the OSD shown above users can press buttons at the front bezel of the monitor to move the cursor, to
confirm the choice or change.ʳ

10 197E3L LCD
On-Screen Display
The OSD Tree
ʳ
Below is an overall view of the structure of the On-Screen Display. You can use this as a reference when you want to work
your way around the different adjustments later on.ʳ
ʳ

197E3L LCD 11
/RFN8QORFN$JLQJ)DFWRU\0RGH
To lock/unlock OSD FUNCTION(User Mode)
The OSD function can be locked by pressing"OK"button(1) for more than 10
seconds, the screen shows following windows for 4 seconds. Every time
when you press"OK" button, this message appears on the screen
automatically .
Unlock OSD function
Unlocked OSD function can be released by pressing "OK" button for more
than 10 seconds again.
$FFHVV)DFWRU\0RGH
1). Turn off monitor.
2).[Push "EXIT" & "MENU" buttons at the same time and hold them]+[Press
"power" button until comes out "Windows screen" ]=> then release all
buttons
3).Press "MENU" button, wait until the OSD menu with Characters
"MERIDIAN 197E3L V2.0 2011-05-09” (below OSD menu) come on the
Screen of the monitor.
Factory Mode indicator
Factory Menu
Cursor can move on gray color area
Hot key function: by pressing " UP " and " DOWN " key Simultaneously at
User Mode (or Factory Mode) (PS: The Of fset R G B function can be used
on reduce or eliminate snowy noise on the background when the resolution
of video signal is 1280*1024vertical 75Hz. Slightly increase or decrease the
value until snowy noise completely disappear .
$FFHVV$JLQJ0RGH
Step 1 : Access Factory Mode then enter Factory Menu.
Step 2 : By pressing " UP" and " DOWN " key to Burning Icon. Press
"MENU then press " UP" and "DOWN " key to turn on Aging Mode.
Step 3 : Disconnect interface cable between Monitor and PC.
After 3 seconds,
bring up:
repeatly
Connect Signal cable again=> go back to normal display

12 197E3L LCD
Philips Pixel Defect Policy
ʳ
Philips' Flat Panel Monitors Pixel Defect Policy
ʳ
Philips strives to deliver the highest quality products. We use some of the
industry's most advanced manufacturing processes and practice stringent
quality control. However, pixel or sub pixel defects on the TFT LCD panels
used in flat panel monitors are sometimes unavoidable. No manufacturer
can guarantee that all panels will be free from pixel defects, but Philips
guarantees that any monitor with an unacceptable number of defects will be
repaired or replaced under warranty. This notice explains the different types
of pixel defects and defines acceptable defect levels for each type. In order
to qualify for repair or replacement under warranty, the number of pixel
defects on a TFT LCD panel must exceed these acceptable levels. For
example, no more than 0.0004% of the sub pixels on a 19" XGA monitor may
be defective. Furthermore, Philips sets even higher quality standards for
certain types or combinations of pixel defects that are more noticeable than
others. This policy is valid worldwide.
Pixels and Sub pixels
A pixel, or picture element, is composed of three sub pixels in the primary
colors of red, green and blue. Many pixels together form an image. When all
sub pixels of a pixel are lit, the three colored sub pixels together appear as a
single white pixel. When all are dark, the three colored sub pixels together
appear as a single black pixel. Other combinations of lit and dark sub pixels
appear as single pixels of other colors.
ʳTypes of Pixel Defects
ʳ
Pixel and sub pixel defects appear on the screen in different ways. There are
two categories of pixel defects and several types of sub pixel defects within
each category. ʳ
Bright Dot Defects Bright dot defects appear as pixels or sub pixels that are
always lit or 'on'. That is, a bright dot is a sub-pixel that stands out on the
screen when the monitor displays a dark pattern. There are the types of
bright dot defects:ʳ
ʳʳ
One lit red, green or
blue sub pixelʳ
Two adjacent lit sub
pixels:
- Red + Blue =
Purple
- Red + Green =
Yellow
- Green + Blue =
Cyan (Light Blue)!
Three adjacent lit sub
pixels (one white
pixel)ʳ
ʳ
A red or blue bright dot must be more than 50 percent brighter
than neighboring dots while a green bright dot is 30 percent
brighter than neighboring dots.ʳ
Black Dot Defects Black dot defects appear as pixels or sub pixels that are
always dark or 'off'. That is, a dark dot is a sub-pixel that stands out on the
screen when the monitor displays a light pattern. These are the types of
black dot defects:ʳ
ʳ
One dark sub pixelʳTwo or three adjacent dark sub pixelsʳ
Proximity of Pixel Defects
ʳ
Because pixel and sub pixels defects of the same type that are near to one
another may be more noticeable, Philips also specifies tolerances for the
proximity of pixel defects.
Pixel Defect Tolerances
ʳ
In order to qualify for repair or replacement due to pixel defects during the
warranty period, a TFT LCD panel in a Philips flat panel monitor must have
pixel or sub pixel defects exceeding the tolerances listed in the following
tables.ʳ
BRIGHT DOT DEFECTSʳACCEPTABLE
LEVEL ʳ
MODELʳ197E3Lʳ
1 lit subpixelʳ3ʳ
2 adjacent lit subpixelsʳ1ʳ
3 adjacent lit subpixels (one white pixel)ʳ0ʳ
Distance between two bright dot defects*ʳ>15mmʳ
Total bright dot defects of all typesʳ3ʳ
BLACK DOT DEFECTSʳACCEPTABLE
LEVEL ʳ
MODELʳ197E3L
ʳ
1 dark subpixelʳ5 or fewerʳ
2 adjacent dark subpixelsʳ2 or fewerʳ
3 adjacent dark subpixelsʳ0ʳ
Distance between two black dot defects*ʳ>15mmʳ
Total black dot defects of all typesʳ5 or fewerʳ
TOTAL DOT DEFECTSʳACCEPTABLE
LEVEL ʳ
MODELʳ197E3L
ʳ
Total bright or black dot defects of all
typesʳ5 or fewerʳ
Note:
* 1 or 2 adjacent sub pixel defects = 1 dot defect

197E3L LCD 13
Mechanical Instruction
Preparation before disassemble
1.Clean the room for disassemble
2.Identify the area for monitor
3.Check the position that the monitors be placed and the quantity of the monitor ;prepare the area for material flow;
according to the actual condition plan the disassemble layout
4.Prepare the implement, equipments, materials as bellow:
1) Press-fixture
2) working table
3) Screw-driver
4) knife*1
5) glove
6) cleaning cloth
7) ESD protection
item picture Operation Tool Notes
1 Disassembly the Rear
cover
2 Disassembly 4 screws,
Take off the stand.
Screw-driver
3 Disassembled the
hexagonal screw *4
Screw-driver

14 197E3L LCD
Mechanical Instruction
4 disassembly the bezel from
the monitor, notice the
disassembly order :
1.Top (1) parts of bezel
2.Left (2) parts of bezel
3.Bottom (3) parts of bezel
4. Right (4) parts of bezel
Don’t draw the BZL
When disassembly
the bezel ,
notice don’t bend
the C/B .
man must wear
glove
The purpose is
loose the BZL
5 Turn over the monitor ,
Bring the Rear cover from
the monitor
6 Draw the control board
cable
7 1. Draw the lamp cables
2. Disassembly 1 screws
1
2
3
4

197E3L LCD 15
Mechanical Instruction
8 Unlock the FFC by using
two hands(see note).
Please carefully use
two hands(one hand
presses the
locking-latch of FFC
cable’s housing, and
at the same time
another hand pulls
out the FFC cable.)
for this step to avoid
from deforming the
terminals of
positive-locking type
FFC cable.
9 Tear off the Mylar Screw-driver
10 Disassemble the
ITF-boardΕpower board
Æ4 screws
Screw-driver
11 Take the PCBA from
Main-BKT and then put it
on the cushion
The locking-latch
of LVDS cable’s
The locking-latch of
FFC cable’s housin
g

16 197E3L LCD
Color Adjustment
Alignment procedure
1. Turn on the LCD monitor
2. Turn on the Timing/pattern generator. See Fig.1
3. Preset LCD color Analyzer CA-1 10
-Remove the lens protective cover of probe CA-A30.
-Set measuring/viewing selector to measuring position for reset
analyzer .(zero calibration) as Fig.2
- Turn on the color analyzer (CA-1 10)
-Press 0-CAL button to starting reset analyzer .
Fig.1 Fig.2
4. Access Factory Mode
1). Turn off monitor.
2). [Push "AUT O" & "MENU" buttons at the same time and hold them]
+[Press "power" button untill comes out "Windows screen" ]
=> then release all buttons
3).Press "MENU button, wait until the OSD menu with
Characters " MERIDIAN 197E3L V2.0 2011-05-09” (below OSD menu)
come on the Screen of the monitor as shown in Fig3.
FactoryModeindicator
)LJ
4). Press button, then select factory mode indicator by "MENU" "LEFT"
or "RIGHT" button .Press"MENU" button to bring up submenu
windows as below:
)LJ
Fig.5
5.Display
Press "UP" or "DOWN" button to select . Change the value
by "UP" or "DOWN" key until the X, Y co-ordinates as below
5.1 Color temperature adjustment
There are six factory preset white color 11500K, 9300K, 8200K, 7500K,
6500K, sRGB, 5000K
Align by Philips PerfecTune (also called FGA) function.
Apply full white pattern, with brightness in 100 % position and the contrast
control at 50 % position.
The 1931 CIE Chromaticity (color triangle) diagram (x , y) coordinate for
the screen center should be:
Product specification
CIE coordinates (x,y)
11500K x = 0.270 ± 0.02
y = 0.281 ± 0.02
PerfectuneII
9300K x = 0.283 ± 0.02
y = 0.297 ± 0.02
PerfectuneII
8200K x = 0.291 ± 0.02
y = 0.306 ± 0.02
PerfectuneII
7500K x = 0.298 ± 0.02
y = 0.314 ± 0.02
PerfectuneII
6500K/sRGB x = 0.313 ± 0.02
y = 0.329 ± 0.02
PerfectuneII
sRGB x = 0.313 ± 0.02
y = 0.329 ± 0.02
PerfectuneII
5000K x = 0.345 ± 0.02
y = 0.357 ± 0.02
PerfectuneII
Production alignment spec
CIE coordinates (x,y)
11500K x = 0.270 ± 0.006
y = 0.281 ± 0.006
PerfectuneII
9300K x = 0.283 ± 0.006
y = 0.297 ± 0.006
PerfectuneII
8200K x = 0.291 ± 0.006
y = 0.306 ± 0.006
PerfectuneII
7500K x = 0.298 ± 0.006
y = 0.314 ± 0.006
PerfectuneII
6500K/sRGB x = 0.313 ± 0.006
y = 0.329 ± 0.006
PerfectuneII
sRGB x = 0.313 ± 0.006
y = 0.329 ± 0.006
PerfectuneII
5000K x = 0.345 ± 0.006
y = 0.357 ± 0.006
PerfectuneII
Quality Inspection specification
CIE coordinates (x,y)
9300K x = 0.283 ± 0.015
y = 0.297 ± 0.015
6500K/sRGB x = 0.313 ± 0.015
y = 0.329 ± 0.015
sRGB x = 0.313 ± 0.015
y = 0.329 ± 0.015

197E3L LCD 17
FAQs (Frequently Asked Questions)

18 197E3L LCD
FAQs (Frequently Asked Questions)

197E3L LCD 19
Electrical Instructions
Electrical characteristics
1. Interface signals
1.1 D-Sub Analog
Input signal: Video, Hsync., Vsync
Video: 0.7 Vp-p, input impedance, 75 ohm @DC
Sync.: Separate sync TTL level , input impedance 2.2k ohm terminate
Hsync Positive/Negative
Vsync Positive/Negative
Composite sync TTL level, input impedance 2.2k ohm terminate (Positive/Negative)
Sync on green video 0.3 Vp-p Negative (Video 0.7 Vp-p Positive)
1.2 DVI-D Digital
Input signal: Single TMDS link (Three channels: RX0-/+, RX1-/+, RX2-/+)
2. Interface
2.1 D-Sub Cable
Length : 1.8 M +/- 50 mm
Fix with monitor when packing, with transplant pin protective cover.
Connector type : D-Sub male with DDC2B pin assignments.
Blue connector thumb-operated jack screws
2.2 DVI Cable
The input signals are applied to the display through DVI-D cable.
Length : 1.8 M +/- 50 mm
Connector type : DVI-D male with DDC-2B pin assignments
White connector thumb-operated jackscrews
With transplant pin protective cover.
3. Timing requirement
3.1 Factory Preset mode definition:
3.1.1 Perfect FOS while presenting those timings.
3.1.2 Will specify those timing in User's Manual
3.2 Preset mode definition:
3.2.1 Need to support those timings.
3.2.2 Perfect FOS after auto adjustment.
3.3 User mode
3.3.1 Can save those timing that not in Preset mode and can be showed
(not over scalar or Panel spec.)
3.3.2 It needs to reserve the 10 timings space in memory size.
3.3.3 Factory modes and preset modes are defined in the enclosed timing table file

20 197E3L LCD
Electrical Instructions
White color adjustment
There are three factory preset white color 9300K, 6500K, sRGB.
Apply full gray64 pattern, with brightness in 100 % position and the contrast control at 50 % position.The 1931 CIE
Chromaticity (color triangle) diagram (x ,y) coordinate for the screencenter should be:
Product specification
CIE
coordinates
(x,y)
9300K x = 0.283 ± 0.02
y = 0.297 ± 0.02
PerfecTune I
6500K/sRGB x = 0.313 ± 0.02
y = 0.329 ± 0.02
PerfecTune I
Production alignment spec.
CIE
coordinates
(x,y)
9300K x = 0.283 ± 0.006
y = 0.297 ± 0.006
PerfecTune I
6500K/sRGB x = 0.313 ± 0.006
y = 0.329 ± 0.006
PerfecTune I
Quality Inspection specification:
CIE
coordinates
(x,y)
9300K x = 0.283 ± 0.015
y = 0.297 ± 0.015
6500K/sRGB x = 0.313 ± 0.015
y = 0.329 ± 0.015
This manual suits for next models
12
Table of contents
Other Energy Star Monitor manuals