Microwave Sensor
Sensor intelligent technology
Welcome to use ES-M09B Microwave Sensor!
The product is a new saving-energy switch; it adopts
microwave sensor mould with high-frequency electro-magnetic
wave (5.8GHz), integrated circuit. It gathers automatism,
convenience, safety, saving-energy and practicality functions.
The wide detection field is consisting of detectors. It works by
receiving human motion. When one enters the detection field, it can start the load at once and
identify automatically day and night. Its installation is very convenient and its using is very wide.
Detection is possible through doors, panes of glass or thin walls.
SPECIFICATION:
Power Sourcing: 220V/AC-240V/AC Detection Range: 360° Ceiling / 180°Wall
Power Frequency: 50/60Hz Detection Distance: 2-10m (radius) adjustable
Ambient Light: 5LUX/30LUX/100LUX/300LUX/DAY 24H(Adjustable)
HF System: 5.8GHz CW radar, ISM band
Time-Delay: 10sec/60sec/5min/12min/30mi(adjustable)
Transmission Power: <10mW Installing Height: 1.5m~3.5m
Rated Load: 1200W (incandescent lamp) Power Consumption: 0.9W
300W (energy-saving lamp) Detection Motion Speed: 0.6~1.5m/s
FUNCTION:
Can identify day and night: It can work in the daytime and at night when it is adjusted on the
“DAY 24H” position(max). It can work in the ambient light less than 5LUX when it is adjusted
on the “5LUX” position (min). As for the adjustment pattern, please refer to the testing
pattern.
SENS adjustable: It can be adjusted according to using location; low sensitivity with only 2m
(radius) for detection distance; High sensitivity could up to 10m (radius), it fits for large room.
Time-Delay is added continually: When it receives the second induction signals after the first
induction, it will compute time once more on the basic of the first time-delay rest.
Time–Delay is adjustable. It can be set according to the consumer’s desire. The minimum
time is 10sec±3sec. The maximum is 30min±1min.
NOTE: the high-frequency output of this
sensor is <10Mw- that is just one 100th of the
transmission power of a mobile phone or the
output of a microwave oven.
INSTALLATIION:(see the diagram)
Switch off the power.
Fix the bottom on the selected position with the inflated screw through the screw holes at
the side of the sensor.
Connecting the power and the load to sensor as per the connection-wire sketch diagram.
Switch on the power and test it.
Connection illumination
Connect N, L with power;
Connect N, A with load.
TEST:
Turn the LUX
knob on the
maximum to
“DAY24H”. Turn
the TIME knob on
the minimum to “10sec”, Turn the SENS knob on the maximum to “10M”.
When you switch on the power, the light will be on at once, and 5-30 seconds later will be
off automatically. Then if the light receives induction signal, it can work normally.
After 5-10sec of the first detection, the light could work again. If there is no induction signal,
the load should be stopped working within 5-15sec.
Note: when testing in daylight, please turn LUX knob to (DAY24H) position, otherwise the
sensor lamp could not work!
NOTES
:
Electrician or experienced human can install it.
The unrest objects can’t be regarded as the installation basis-face.
In front of the detection window there shouldn’t be hinder or unrest objects affecting
detection.
Avoid installing it near air temperature alteration zones for example: air condition, central
heating, etc.
For your safety. Please don’t open the case if you find hitch after installation.
In order to avoid the unexpected damage of product, please add a safe device of 6A when
installing Microwave sensor, for example, fuse, safe tube etc.
SOME PROBLEM AND SOLVED WAY
The load don’t work:
a. Check the power and the load.
b. Whether the indicator light is turned on after sensing? If yes, please check load.
c. If the indicator light does not turn on after sensing, please check if the working light
corresponds to the ambient light.
d. Please check if the working voltage corresponds to the power source.
The sensitivity is poor:
a. Please check if in front of the detection window there is hinder that has effect on
receiving the signals.
b. Please check the ambient temperature.
c. Please check if the signals source is in the detection fields.
d. Please check the installation height.
The sensor can’t shut automatically the load:
a. If there are continual signals in the detection fields.
b. If the time delay is set to the longest.
c. If the power corresponds to the instruction.
d. If the air temperature changes near the sensor, air condition or central heating etc.

Popular Accessories manuals by other brands

RKC INSTRUMENT CZ-200P instruction manual

RKC INSTRUMENT

RKC INSTRUMENT CZ-200P instruction manual

Evolveo ACS PIRT manual

Evolveo

Evolveo ACS PIRT manual

Omron ZJ-SD Series user manual

Omron

Omron ZJ-SD Series user manual

Senect Oxygen Sensor O2S manual

Senect

Senect Oxygen Sensor O2S manual

Thermo Scientific Cytomat 2 manual

Thermo Scientific

Thermo Scientific Cytomat 2 manual

incubato IN-36DDI user manual

incubato

incubato IN-36DDI user manual

PCB Piezotronics M102B18 Installation and operating manual

PCB Piezotronics

PCB Piezotronics M102B18 Installation and operating manual

Petroline-A U-150 Operation manual

Petroline-A

Petroline-A U-150 Operation manual

Panasonic HL-C203B instruction manual

Panasonic

Panasonic HL-C203B instruction manual

Lithonia Lighting OALD 100MV 120 P LP installation instructions

Lithonia Lighting

Lithonia Lighting OALD 100MV 120 P LP installation instructions

Samsung F-SS-PRES-001 quick start guide

Samsung

Samsung F-SS-PRES-001 quick start guide

DOL 58 Technical user guide

DOL

DOL 58 Technical user guide

HAISEN HD06VCRH 3 (HN074) manual

HAISEN

HAISEN HD06VCRH 3 (HN074) manual

Ecolink CS-402 Installation instructions & user guide

Ecolink

Ecolink CS-402 Installation instructions & user guide

Dimango HS3600 Instruction guide

Dimango

Dimango HS3600 Instruction guide

Elko iNELSAir AirQS-100 quick start guide

Elko

Elko iNELSAir AirQS-100 quick start guide

ekwb EK-FC980 GTX TF5 R2.0 Backplate Installation and mounting manuals

ekwb

ekwb EK-FC980 GTX TF5 R2.0 Backplate Installation and mounting manuals

Garmin GFS 10 - Fuel Sensor Quick reference guide

Garmin

Garmin GFS 10 - Fuel Sensor Quick reference guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.