EnPro Quincy Air Master QT-10 User manual

This manual contains important safety information and must be made
available to all personnel who operate and/or maintain this product.
Carefully read this manual before attempting to operate or perform
maintenance on this compressor.
Fill Out & Return Warranty Registration Card Located Inside
Manual No. 50314-200
October 2008 Edition
QTQT
QTQT
QT
®®
®®
®
Industrial & Air Master SeriesIndustrial & Air Master Series
Industrial & Air Master SeriesIndustrial & Air Master Series
Industrial & Air Master Series
Model QTModel QT
Model QTModel QT
Model QT
-10-10
-10-10
-10
Parts Manual
Record of Change 200
Manual Brought to You By: IndustrialAirPower.com

QT-10 Industrial / Air Master Quincy Compressor
50314-200, October 2008 1 3501 Wismann Lane, Quincy IL - 62305-3116
TABLE OF CONTENTS
Serial Number Identification .................................2
Ordering Replacement Parts ................................2
Quin-Cip Lubricant ................................................2
Crankcase Lubricant Capacity .............................2
Crankshaft Group ..................................................3
Crankcase Group...................................................4
Cylinder & Head Groups ...................................5-6
Connecting Rod & Piston Groups.....................7-8
Control Piping Schematics ...................................9
Pilot Valves ..........................................................10
Pilot Valve Repair Kit ..........................................10
Differential Setting Charts ..................................10
Suction Valve Unloader Assemblies .................. 11
Decals...................................................................11
Gasket Set............................................................12
Recommended Spare Parts ................................12
Overhaul Kits .......................................................12
Head Kits..............................................................12
Typical Unit Repair Parts List ........................13-14
INTRODUCTION
This manual provides information for the Model QT-
10 reciprocating compressor, per Record of Change
200.
The Model QT-10 is an aircooled, two stage, two
cylinder, splash lubricated compressor, with up to
175 PSI continuous pressure capability. It has a 5"
low pressure bore and a 2.75" high pressure bore, with
a 3.5" stroke. This compressor can be run at 550-1000
RPM.
Available options include:
-head unloaders
CHANGES
Since previous printing dated April 2004:
The QT-10 basic compressor was redesigned.

QT-10 Industrial / Air Master Quincy Compressor
50314-200, October 2008 2 3501 Wismann Lane, Quincy IL - 62305-3116
Package Part No. Description
Barrel 112541D032 55 gal., SAE 10W
Pail 112541P032 5 gal., SAE 10W
Gallon 112541G032 1 gal., SAE 10W
Gallon Case 112541X032 (4)-1 gal., SAE 10W
Quart 112541Q032 1 qt., SAE 10W
Quart Case 112541C032 (12)-1 qt., SAE 10W
Barrel 112542D068 55 gal., SAE 20
Pail 112542P068 5 gal., SAE 20
Gallon 112542G068 1 gal., SAE 20
Gallon Case 112542X068 (4)-1 gal., SAE 20
Quart 112542Q068 1 qt., SAE 20
Quart Case 112542C068 (12)-1 qt., SAE 20
Barrel 112543D100 55 gal., SAE 30
Pail 112543P100 5 gal., SAE 30
Gallon 112543G100 1 gal., SAE 30
Gallon Case 112543X100 (4)-1 gal., SAE 30
Quart 112543Q100 1 qt., SAE 30
Quart Case 112543C100 (12)-1 qt., SAE 30
ORDERING
REPLACEMENT PARTS
Prompt service can be rendered on repair parts orders
if the following information is given:
Item 1) the model number, record of change num-
ber, & serial number.
Item 2) the exact part number needed. (Do not
order by item numbers.)
Item 3) the exact quantity needed.
Item 4) the preferred type of transportation.
QUIN-CIP LUBRICANT
Refer to the chart below to order Quin-Cip compres-
sor oil from your local authorized Quincy distributor.
CRANKCASE LUBRICANT
CAPACITY
Model Capacity
QT-10 2.5 qts. (2.37 litres)
SERIAL NUMBER
IDENTIFICATION
The unit serial number identification tag is located on
the air tank top plate. The basic compressor serial
number decal is located on the side of the crankcase
opposite the oil fill side. Fill in the numbers from your
compressor unit and basic compressor in the corre-
sponding spaces provided here, and reference this
page when ordering replacement parts.
All replacement parts are to be ordered through an
authorized Quincy distributor. Insist on genuine
Quincy parts only! Failure to do so may void war-
ranty.
Unit Serial Number
Basic Serial Number
DANGER !
WARNING !
CAUTION !
CAUTION !
Refer to the QT & PLT Industrial / Air Master Series instruc-
tion manual for vital lubrication information.
Follow all safety precautions outlined in the QT & PLT
Industrial / Air Master Series instruction manual.
Do not operate this compressor without a totally enclosed
belt guard or any other required safety equipment.
Air used for breathing or food processing must meet OSHA
1910.134orFDA 21CFR178.3570 regulations. Failure todo
so may cause severe injury or death.

QT-10 Industrial / Air Master Quincy Compressor
50314-200, October 2008 3 3501 Wismann Lane, Quincy IL - 62305-3116
CRANKSHAFT GROUP 116174CRANKSHAFT GROUP 116174
CRANKSHAFT GROUP 116174CRANKSHAFT GROUP 116174
CRANKSHAFT GROUP 116174

QT-10 Industrial / Air Master Quincy Compressor
50314-200, October 2008 4 3501 Wismann Lane, Quincy IL - 62305-3116
CRANKCASE GROUP 116175CRANKCASE GROUP 116175
CRANKCASE GROUP 116175CRANKCASE GROUP 116175
CRANKCASE GROUP 116175

QT-10 Industrial / Air Master Quincy Compressor
50314-200, October 2008 5 3501 Wismann Lane, Quincy IL - 62305-3116
CYLINDER & HEAD GROUP 116178CYLINDER & HEAD GROUP 116178
CYLINDER & HEAD GROUP 116178CYLINDER & HEAD GROUP 116178
CYLINDER & HEAD GROUP 116178
(without head unloaders)

QT-10 Industrial / Air Master Quincy Compressor
50314-200, October 2008 6 3501 Wismann Lane, Quincy IL - 62305-3116
CYLINDER & HEAD GROUP 116178-001CYLINDER & HEAD GROUP 116178-001
CYLINDER & HEAD GROUP 116178-001CYLINDER & HEAD GROUP 116178-001
CYLINDER & HEAD GROUP 116178-001
(with head unloaders)

QT-10 Industrial / Air Master Quincy Compressor
50314-200, October 2008 7 3501 Wismann Lane, Quincy IL - 62305-3116
CONNECTING ROD & PISTON GROUP 116176XCONNECTING ROD & PISTON GROUP 116176X
CONNECTING ROD & PISTON GROUP 116176XCONNECTING ROD & PISTON GROUP 116176X
CONNECTING ROD & PISTON GROUP 116176X
(low pressure)

QT-10 Industrial / Air Master Quincy Compressor
50314-200, October 2008 8 3501 Wismann Lane, Quincy IL - 62305-3116
CONNECTING ROD & PISTON GROUP 116177XCONNECTING ROD & PISTON GROUP 116177X
CONNECTING ROD & PISTON GROUP 116177XCONNECTING ROD & PISTON GROUP 116177X
CONNECTING ROD & PISTON GROUP 116177X
(high pressure)

QT-10 Industrial / Air Master Quincy Compressor
50314-200, October 2008 9 3501 Wismann Lane, Quincy IL - 62305-3116
relief valve
pressure gauge
release valve
pressure switch
check valve
discharge line
pilot valve
with lockout stem
relief valve
pressure gauge
release valve
p
ressure switch
check valve
discharge line
pressure gauge
relief valve
check valve
discharge line
to low and high
pressure
head unloaders
pilot valve
Pilot valve is open (stem screwed out)
for Continuous Run operation
Pilot valve is closed (stem screwed in)
Control Piping
For Automatic Start/Stop
(with loadless starting)
Control Piping
For Continuous Run
Control Piping
For Dual Control
to low and high
pressure
head unloaders
CONTROL PIPING SCHEMACONTROL PIPING SCHEMA
CONTROL PIPING SCHEMACONTROL PIPING SCHEMA
CONTROL PIPING SCHEMATICSTICS
TICSTICS
TICS

QT-10 Industrial / Air Master Quincy Compressor
50314-200, October 2008 10 3501 Wismann Lane, Quincy IL - 62305-3116
PILOT VPILOT V
PILOT VPILOT V
PILOT V
ALAL
ALAL
AL
VESVES
VESVES
VES
Add dash # listed below to 110832 (per pressure setting) to
obtain correct pilot valve.
Add dash # listed below to 110998 (per pressure setting) to
obtain correct pilot valve.
110832 Series Pilot Valve (continuous run operation) 110998 Series Pilot Valve (dual control operation)
ItemItem
ItemItem
Item PartPart
PartPart
Part
##
##
#Qty.Qty.
Qty.Qty.
Qty. NumberNumber
NumberNumber
Number DescriptionDescription
DescriptionDescription
Description
1 2 screen
2 1 filter
3 1 "o"ring
4 1 see chart below pilot valve spring
5 1 ball
Can be used to repair 110832 series pilot valves only. Cus-
tomer must specify which spring when ordering repair kit.
Pilot Valve Repair Kit 110832-051
UnloadUnload
UnloadUnload
Unload Min. Dif.Min. Dif.
Min. Dif.Min. Dif.
Min. Dif. Max. Dif.Max. Dif.
Max. Dif.Max. Dif.
Max. Dif.
(PSI)(PSI)
(PSI)(PSI)
(PSI) (PSI)(PSI)
(PSI)(PSI)
(PSI) (PSI)(PSI)
(PSI)(PSI)
(PSI)
40 2 5
60 3 10
100 4 20
150 5 30
175 5 45
Applies to 110998 series pilot valves only.
Differential Setting Chart
Dash #Dash #
Dash #Dash #
Dash # Load PSILoad PSI
Load PSILoad PSI
Load PSI Unload PSIUnload PSI
Unload PSIUnload PSI
Unload PSI
-100 90 100
-997 * 30-70 adjustable
-998 * 71-150 adjustable
-999 * 151-175 adjustable
* Customer to set, see differential setting chart. Additional
factory preset valves are available upon request.
Dash #Dash #
Dash #Dash #
Dash # Load PSILoad PSI
Load PSILoad PSI
Load PSI Unload PSIUnload PSI
Unload PSIUnload PSI
Unload PSI
-115 100 115
-140 125 140
-165 150 165
Spring Part #Spring Part #
Spring Part #Spring Part #
Spring Part # UnloadUnload
UnloadUnload
Unload Min. Dif.Min. Dif.
Min. Dif.Min. Dif.
Min. Dif. Max. Dif.Max. Dif.
Max. Dif.Max. Dif.
Max. Dif.
(item 4)(item 4)
(item 4)(item 4)
(item 4) (PSI)(PSI)
(PSI)(PSI)
(PSI) (PSI)(PSI)
(PSI)(PSI)
(PSI) (PSI)(PSI)
(PSI)(PSI)
(PSI)
Differential Setting Chart
110832-052 (red) 30 2 4
"4058
"5058
"6058
"70510
110832-053 (yellow) 80 5 10
"90512
" 100 5 13
" 110 5 15
" 120 5 15
" 130 5 18
" 140 5 18
" 150 5 20
110832-054 (green) 160 5 15
" 170 5 20
" 175 5 23
Not all pilots are for use with all compressor systems. Make
sure that the pilot you order is set within the safe operating
limits of your compressor. Failure to heed this warning
could result in an explosion.
WARNING !

QT-10 Industrial / Air Master Quincy Compressor
50314-200, October 2008 11 3501 Wismann Lane, Quincy IL - 62305-3116
3
2
1
ItemItem
ItemItem
Item PartPart
PartPart
Part
##
##
#Qty.Qty.
Qty.Qty.
Qty. NumberNumber
NumberNumber
Number DescriptionDescription
DescriptionDescription
Description
1 1 110831 serial number & nameplate
2 1 127889-A decal, CAUTION!, MANUAL
3 1 127889-B decal, DANGER!,"Air from this...."
DECALS
WARNING !
InstallationInstallation
InstallationInstallation
Installation
The pilot valve is mounted directly into the air tank.
Compressors in the field, not equipped with these
controls, can be converted. Consult your local Quincy
distributor for assistance with conversion procedures.
ServiceService
ServiceService
Service
If a change in pilot valve operation is detected, re-
move the pilot valve from the air tank and check the
screen in the inlet of the pilot valve for obstructions.
Clean the screen if necessary.
AdjustmentAdjustment
AdjustmentAdjustment
Adjustment
The unloading pressure is adjustable and is regulated
by turning the unload adjustment hex nut (refer to
pilot valve illustrations). Turn the hex nut clockwise
to increase and counterclockwise to decrease the
unloading pressure.
The differential (difference between unloading
and loading pressure) is set by turning the differen-
tial adjustment hex nut (refer to pilot valve illustra-
tions). Increase the differential pressure by turning
the hex nut clockwise - decrease by turning counter-
clockwise. Make all adjustments in small increments.
Tighten the locknuts after adjustment.
SUCTION VALVE
UNLOADER ASSEMBLIES
DescriptionDescription
DescriptionDescription
Description
The Quincy suction valve unloader assembly consists
of unloading assemblies on the suction valves, having
a plunger to contact the suction valve reed and an
unloader pilot valve (110832 or 110998 series) to
automatically regulate the passing of air tank pres-
sure to the unloading arrangement.
Continuous Run OperationContinuous Run Operation
Continuous Run OperationContinuous Run Operation
Continuous Run Operation
Suction valve unloader assemblies are recommended
for use on Quincy compressors where the compressor
is to run continuously and a constant pressure is to be
maintained. The purpose is to automatically unseat
the suction valve of the compressor when the air
supply is greater than the demand.
Unloading occurs when air tank pressure is suffi-
cient to overcome pilot valve spring pressure. The
check ball is then unseated, allowing air tank pres-
sure to pass to the unloader assemblies. The compres-
sor will run unloaded until the air tank pressure
drops to a predetermined level. At this time, the
action of the ball is reversed, shutting off air tank
pressure to the unloader assemblies and venting the
unloader to atmosphere. This allows the compressor
to load. The drive, either electric motor or engine,
runs continuously and must be started and stopped
manually. 110832 series pilot valves feature a toggle
lever which can be flipped to provide manual unload-
ing.
Dual Control OperationDual Control Operation
Dual Control OperationDual Control Operation
Dual Control Operation
Dual control operation is designed to provide a
choice between "start/stop" or "continuous run" op-
eration. The 110998 series pilot valve can be set for
"start/stop" operation by turning the knurled knob at
the end of the pilot valve (refer to illustration for
110998 series pilot valve) clockwise until it stops.
Under these circumstances, a pressure switch is re-
quired to stop the motor. Failure to use a pressure
switch, with the pilot valve locked out, will result in
unsafe conditions.
A pressure switch must be incorporated whenever 110998
series pilot valve is employed as part of the control system.
The compressor will operate in the continuous run
mode if the knurled knob is turned counterclockwise
until it stops.
Decals

QT-10 Industrial / Air Master Quincy Compressor
50314-200, October 2008 12 3501 Wismann Lane, Quincy IL - 62305-3116
ItemItem
ItemItem
Item PartPart
PartPart
Part
##
##
#Qty.Qty.
Qty.Qty.
Qty. NumberNumber
NumberNumber
Number DescriptionDescription
DescriptionDescription
Description
Overhaul Kit KQT10G
ItemItem
ItemItem
Item PartPart
PartPart
Part
##
##
#Qty.Qty.
Qty.Qty.
Qty. NumberNumber
NumberNumber
Number DescriptionDescription
DescriptionDescription
Description
1 116162K valve assembly kit, LP
1 116163K valve assembly kit, HP
1 110377E100 air filter element, (fits
110377F125 filter)
Head Kit KQT10H
ItemItem
ItemItem
Item PartPart
PartPart
Part
##
##
#Qty.Qty.
Qty.Qty.
Qty. NumberNumber
NumberNumber
Number DescriptionDescription
DescriptionDescription
Description
Gasket Set 114772
ItemItem
ItemItem
Item PartPart
PartPart
Part
##
##
#Qty.Qty.
Qty.Qty.
Qty. NumberNumber
NumberNumber
Number DescriptionDescription
DescriptionDescription
Description
Recommended Spare Parts
1 110377E100 air filter element
1 114772 gasket set
1 116162X valve plate assembly, LP
1 116163X valve plate assembly, HP
1 116176 piston ring set, LP
1 116177 piston ring set, HP
1 114772 gasket set
1 116163X valve plate assembly, HP
1 116162X valve plate assembly, LP
1 110377E100 air filter element
1 110190-054 piston pin assembly, LP
1 110190-055 piston pin assembly, HP
2 114662K002 connecting rod assembly
1 111333 breather filter
1 111781-001 oil seal
1 111274-002 gasket, head to valve plate
1 114585 gasket, cylinder to valve plate
1 114586 gasket, head to valve plate
1 114599 gasket, cylinder to valve plate
1 114583 gasket, crankcase to brg. carrier
1 114584 gasket, cylinder to crankcase
3 112708-908 "o"ring, silicone
ItemItem
ItemItem
Item PartPart
PartPart
Part
##
##
#Qty.Qty.
Qty.Qty.
Qty. NumberNumber
NumberNumber
Number DescriptionDescription
DescriptionDescription
Description
1 114508-001 intercooler
2 111482-100 nut
2 111265-100 sleeve
Intercooler Repair Kit 114508K002

QT-10 Industrial / Air Master Quincy Compressor
50314-200, October 2008 13 3501 Wismann Lane, Quincy IL - 62305-3116
TYPICAL UNIT REPAIR PARTS LIST
(QT-10 simplex - horizontal tank - electric motor)
PartPart
PartPart
Part PartPart
PartPart
Part
QtyQty
QtyQty
Qty NumberNumber
NumberNumber
Number NumberNumber
NumberNumber
Number DescriptionDescription
DescriptionDescription
Description
80 gal. 120 gal.
1 113268-200 113271-200 tank
1 n/a 113281 top plate
1 2713 111136-050 tank drain valve
1 111136-075 111136-100 service valve
1 110514-300 110514-300 pressure gauge
1 110512-005 110512-005 pressure switch, 135-175 PSI
1 110513-200 110513-200 pressure relief valve, 200 PSI (in tank)
1 2961-215 2961-215 pressure relief valve, 215 PSI (in discharge line)
1 116209-100 116209-100 check valve
6 ft. 110515-100 110515-100 discharge tube (1" copper tube to be formed by customer)
10 h.p.
2110258B082 drive belt
1110483 motor pulley
1110484 bushing
1113242K004 113242K004 belt guard assembly
200v, 3Ø 230/460v, 3Ø
140656 4014 10 h.p. motor (ODP)
Part numbers shown in italics apply to tank mounted units and base mounted units.
The parts listed here are for standard QT-10 units and may or may not be applicable to specially built units. Check with your local
authorized Quincy distributor for parts that can be used for custom built units. Make sure the components you order are rated within the
safe operating limits of your system. If you are doubtful about which components to order, contact your local Quincy distributor.
! Pre-formed discharge tubes are available. Contact factory with model & tank size information.
!
PartPart
PartPart
Part PartPart
PartPart
Part
QtyQty
QtyQty
Qty NumberNumber
NumberNumber
Number NumberNumber
NumberNumber
Number DescriptionDescription
DescriptionDescription
Description
120 gal.
1 114859 tank
1 n/a top plate
1 2713 tank drain valve
1 111136-075 service valve
1 110514-300 pressure gauge
1 110512-175 pressure switch, 135-175 PSI
1 110513-200 pressure relief valve, 200 PSI (in tank)
1 2961-215 pressure relief valve, 215 PSI (in discharge line)
1 116209-100 check valve
6 ft. 110515-100 discharge tube (1" copper tube to be formed by customer)
10 h.p.
2110258B082 drive belt
1110483 motor pulley
1110484 bushing
1113242K004 belt guard assembly
200v, 3Ø 230/460v, 3Ø
140656 4014 10 h.p. motor (ODP)
!
(QT-10 simplex - vertical tank - electric motor)

QT-10 Industrial / Air Master Quincy Compressor
50314-200, October 2008 14 3501 Wismann Lane, Quincy IL - 62305-3116
TYPICAL UNIT REPAIR PARTS LIST
(QT-10 duplex - horizontal tank - electric motor)
PartPart
PartPart
Part PartPart
PartPart
Part
QtyQty
QtyQty
Qty NumberNumber
NumberNumber
Number NumberNumber
NumberNumber
Number DescriptionDescription
DescriptionDescription
Description
200 gal. 240 gal.
1 113469-200 112400-200 tank (standard)
1 113468-200 113470-200 tank (pedestal)
2 113281 113282-001 top plate (for pedestal tank)
1 111136-050 111136-050 tank drain valve
1 111136-100 111136-100 service valve
1 110514-300 110514-300 pressure gauge
1 110512-005 110512-005 pressure switch, 135-175 PSI
1 110512-003 110512-003 pressure switch, 125-165 PSI
1 110513-200 110513-200 pressure relief valve, 200 PSI (in tank)
2 2961-215 2961-215 pressure relief valve, 215 PSI (in discharge line)
2 116209-100 116209-100 check valve
12 ft. 110515-100 110515-100 discharge tube (1" copper tube to be formed by customer)
10 h.p.
4110258B082 drive belt
2110483 motor pulley
2110484 bushing
2113242K004 113242K004 belt guard assembly
200v, 3Ø 230/460v, 3Ø
240656 4014 10 h.p. motor (ODP)
Part numbers shown in italics apply to tank mounted units and base mounted units.
The parts listed here are for standard QT-10 units and may or may not be applicable to specially built units. Check with your local
authorized Quincy distributor for parts that can be used for custom built units. Make sure the components you order are rated within the
safe operating limits of your system. If you are doubtful about which components to order, contact your local Quincy distributor.
! Pre-formed discharge tubes are available. Contact factory with model & tank size information.
!
PartPart
PartPart
Part PartPart
PartPart
Part
QtyQty
QtyQty
Qty NumberNumber
NumberNumber
Number NumberNumber
NumberNumber
Number DescriptionDescription
DescriptionDescription
Description
base unit tank unit
1 113716-200 tank, 200 PSI
1 115096 115096 top plate
1 111136-025 tank drain valve
1 111136-075 111136-075 service valve
1 110514-300 110514-300 pressure gauge
1 110513-200 110513-200 pressure relief valve, 200 PSI (in tank)
2 110357B078 110357B078 drive belt
1 115084 115084 engine pulley
1 8924 8924 engine pulley bushing
1 113242-006 113242-006 belt guard assembly
1 113143-004 113143-004 throttle control
1 113720-001 113720 Kohler engine group, 18 h.p. (includes exhaust system& throttle control)
1 2961-215 2961-215 pressure relief valve, 215 PSI (in discharge line)
1 116209-100 116209-100 check valve
2 ft. 110515-100 110515-100 discharge tube (1" copper tube to be formed by customer)
1 110948-100 110948-100 nut w/ sleeve
1 112316 112316 fuel tank group, 6 gal. (incl. fuel tank & 6 ft. of hose)
1 113708-175 113708-175 pilot, 165-175 PSI
! Pre-formed discharge tubes are available. Contact factory with model & tank size information.
!
(QT-10 gasoline engine driven)

QT-10 Industrial / Air Master Quincy Compressor
50314-200, October 2008 15 3501 Wismann Lane, Quincy IL - 62305-3116
QUINCY COMPRESSOR
STANDARD TERMS AND CONDITIONS
LEGAL EFFECT: Except as expressly otherwise agreed to in writing by an authorized representative of Seller, the
following terms and conditions shall apply to and form a part of this order and any additional and/or different terms
of Buyer’s purchase order or other form of acceptance are rejected in advance and shall not become a part of this
order.
Therightsof Buyerhereundershall beneitherassignable nortransferableexcept withthewritten consentofSeller.
ThisordermaynotbecanceledoralteredexceptwiththewrittenconsentofSellerandupontermswhichwillindemnify
Seller against all loss occasioned thereby. All additional costs incurred by Seller due to changes in design or
specifications, modification of this order or revision of product must be paid for by Buyer.
In addition to the rights and remedies conferred upon Seller by this order, Seller shall have all rights and remedies
conferred at law and in equity and shall not be required to proceed with the performance of this order if Buyer is in
default in the performance of such order or of any other contract or order with seller.
TERMSOFPAYMENT:Unlessotherwisespecifiedintheorderacknowledgment,thetermsofpaymentshallbe1%
15, net forty-five (45) days after shipment. These terms shall apply to partial as well as complete shipments. If any
proceedingbeinitiatedby oragainstBuyerunder any bankruptcyorinsolvencylaw, or inthejudgment of Sellerthe
financial condition of Buyer, at the time the equipment is ready for shipment, does not justify the terms of payment
specified, Seller reserves the right to require full payment in cash prior to making shipment. If such payment is not
received within fifteen (15) days after notification of readiness for shipment, Seller may cancel the order as to any
unshipped item and require payment of its reasonable cancellation charges.
If Buyer delays shipment, payments based on date of shipment shall become due as of the date when ready for
shipment. IfBuyerdelayscompletionofmanufacture,Sellermayelect torequire paymentaccordingtopercentage
ofcompletion. EquipmentheldforBuyershallbeatBuyer’sriskandstoragechargesmaybeappliedatthediscretion
of Seller.
Accounts past due shall bare interest at the highest rate lawful to contract for but if there is no limit set by law, such
interestshallbeeighteenpercent(18%). Buyershallpayallcostandexpenses,includingreasonableattorney’sfees,
incurredincollectingthe same, and noclaim,exceptclaims within Seller’swarrantyofmaterial or workmanship, as
stated below, will be recognized unless delivered in writing to Seller within thirty (30) days after date of shipment.
TAXES: All prices exclude present and future sales, use, occupation, license, excise, and other taxes in respect of
manufacture,salesordelivery,allofwhichshallbepaidbyBuyerunlessincludedinthepurchasepriceattheproper
rate or a proper exemption certificate is furnished.
ACCEPTANCE: All offers to purchase, quotations and contracts of sales are subject to final acceptance by an
authorized representative at Seller’s plant.
DELIVERY:Exceptasotherwisespecifiedinthisquotation,deliverywillbeF.O.B.pointofshipment. Intheabsence
ofexactshippinginstruction, Seller willuseitsdiscretion regardingbestmeansof insured shipment. Noliabilitywill
beacceptedbySellerforsodoing. AlltransportationchargesareatBuyer’sexpense. Timeofdeliveryisanestimate
only and is based upon the receipt of all information and necessary approvals. The shipping schedule shall not be
construedtolimitsellerinmakingcommitmentsformaterialsorinfabricatingarticlesunderthisorderinaccordance
with Seller’s normal and reasonable production schedules.
Sellershallinnoeventbeliablefordelayscausedbyfires,actsofGod,strikes,labordifficulties,actsofgovernmental
ormilitaryauthorities, delaysintransportationor procuringmaterials,or causesofanykind beyondSeller’scontrol.
No provision for liquidated damages for any cause shall apply under this order. Buyer shall accept delivery within
thirty (30) days after receipt of notification of readiness for shipment. Claims for shortages will be deemed to have
been waived if not made in writing with ten (10) days after the receipt of the material in respect of which any such
shortage is claimed. Seller is not responsible for loss or damage in transit after having received “In Good Order”
receipt from the carrier. All claims for loss or damage in transit should be made to the carrier.

QT-10 Industrial / Air Master Quincy Compressor
50314-200, October 2008 16 3501 Wismann Lane, Quincy IL - 62305-3116
TITLE & LIEN RIGHTS: The equipment shall remain personal property, regardless of how affixed to any realty or
structure. Until the price (including any notes given therefore) of the equipment has been fully paid in cash, Seller
shall, in the event of Buyer’s default, have the right to repossess such equipment.
PATENT INFRINGMENT: If properly notified and given an opportunity to do so with friendly assistance, Seller will
defendBuyerandtheultimateuseroftheequipmentfromanyactualorallegedinfringementofanypublishedUnited
States patent by the equipment or any part thereof furnished pursuant hereto (other than parts of special design,
construction, or manufacture specified by and originating with Buyer), and will pay all damages and costs awarded
bycompetentcourtinanysuitthusdefendedorofwhichitmayhavehadnoticeandopportunitytodefendasaforesaid.
STANDARD WARRANTY: Seller warrants that products of its own manufacture will be free from defects in
workmanshipandmaterialsundernormaluseandservicefortheperiodspecifiedintheproductinstructionmanual.
WarrantyforservicepartswillbeNinety(90)daysfromdateoffactoryshipment. ElectricMotors,gasolineanddiesel
engines, electrical apparatus and all other accessories, components and parts not manufactured by Seller are
warranted only to the extent of the original manufacturer’s warranty.
Noticeoftheallegeddefect must be giventotheSeller,in writing with allidentifyingdetailsincludingserial number,
typeofequipmentanddateofpurchasewithinthirty(30)daysofthediscoveryofthesameduringthewarrantyperiod.
Seller’ssoleobligationonthiswarrantyshall be,atitsoption,torepairorreplaceorrefundthepurchasepriceofany
product or part thereof which proves to be defective. If requested by Seller, such product or part thereof must be
promptly returned to seller, freight prepaid, for inspection.
Sellerwarrantsrepairedorreplacedpartsofitsownmanufactureagainstdefectsinmaterialsandworkmanshipunder
normal use and service for ninety (90) days or for the remainder of the warranty on the product being repaired.
This warranty shall not apply and Seller shall not be responsible or liable for:
(a) Consequential, collateral or special losses or damages;
(b) Equipmentconditionscausedbyfairwearandtear,abnormalconditionsofuse,accident,neglectormisuse
of equipment, improper storage or damage resulting during shipping;
(c) Deviation from operating instructions, specifications or other special terms of sale;
(d) Labor charges, loss or damage resulting from improper operation, maintenance or repairs made by
person(s) other than Seller or Seller’s authorized service station.
In no event shall Seller be liable for any claims whether arising from breach of contract or warranty or claims of
negligence or negligent manufacture in excess of the purchase price.
THIS WARRANTY IS THE SOLE WARRANTY OF SELLERS AND ANY OTHER WARRANTIES, WHETHER
EXPRESSORIMPLIEDINLAWORIMPLIEDINFACT,INCLUDINGANYWARRANTIESOFMERCHANTABILITY
AND FITNESS FOR PARTICULAR USE ARE HEREBY SPECIFICALLY EXCLUDED.
LIABILITY LIMITATIONS: Under no circumstances shall the Seller have any liability for liquidated damages or for
collateral, consequential or special damages or for loss of profits, or for actual losses or for loss of production or
progress of construction, whether resulting from delays in delivery or performance, breach of warranty, negligent
manufacture or otherwise.
ENVIROMENTALANDOSHAREQUIREMENTS:Atthetimeofshipmentoftheequipmentfromthefactory,Quincy
Compressor / Ortman Fluid Power will comply with the various Federal, State and local laws and regulations
concerningoccupationalhealthandsafetyandpollution. However,intheinstallationandoperationoftheequipment
andothermattersoverwhichthesellerhasnocontrol,theSellerassumesnoresponsibilityforcompliancewiththose
laws and regulations, whether by the way of indemnity, warranty or otherwise.
June 30, 2003

ReciprRecipr
ReciprRecipr
Reciprocating / Systems:ocating / Systems:
ocating / Systems:ocating / Systems:
ocating / Systems: 217.222.7700
Air MasterAir Master
Air MasterAir Master
Air Master 217.277.0270
E-mail:E-mail:
E-mail:E-mail:
E-mail: info@quincycompressor.com
WW
WW
Website:ebsite:
ebsite:ebsite:
ebsite: quincycompressor.com
quincyairmaster.com
© 2006 Quincy Compressor, an EnPro Industries company
All Rights Reserved. Litho in U.S.A.
Table of contents
Popular Compressor manuals by other brands

Ingersoll-Rand
Ingersoll-Rand 9/235 Operating, Maintenance & Parts Manual

Ingersoll-Rand
Ingersoll-Rand IR2PS Operation and maintenance

IKH
IKH XTTURBO instruction manual

John Bunn
John Bunn Neb-u-Tyke Bella the Butterfly JB0112-071 user manual

EINHELL
EINHELL TE-AC 270/24/10 Original operating instructions

Ingersoll-Rand
Ingersoll-Rand XHP900CM Operating, Maintenance & Parts Manual

Ferm
Ferm CRM1039 Original instructions

Bitzer
Bitzer ST-600-2 technical information

EKOM
EKOM DK50 2V S Instructions for use and service manual

SHARKS
SHARKS SHK 477 Instruction for operation and maintenance

Becker
Becker KDT 3.140 operating instructions

Panasonic
Panasonic Matsushita DA57C84RCU6 Specification sheet