1

Note:
See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual
There are currently 2 version of EntryPass Platform1 Access Control System available for different card
number system
1) EntryPass Platform1 Access Control System (6 Digit Card Number System) cater for 6 digit card
number installation
2)EntryPass Platform1 Access Control System (10 Digit Card Number System) cater for 10 digit card
number installation
For EntryPass Platform1 Access Control System to work correctly, both control panel and software MUST
be using the same card number system
This software installation manual might be updated without prior notice
Please refer to separate EntryPass Platform1 User Manual for detail operation help. The Official
EntryPass Platform1 User Manual can be downloaded from our website under “Download” section
ENTRYPASS
2
Model: EP.MINI

Technical Support
If you cannot find the answer to your question in this manual or in the Help files, we recommend you
contact your system installer. Your installer is familiar with your system configuration and should be able
to answer any of your questions.
Should you need additional information, please call our Technical Support Help desk, Monday to Friday
9:00 AM to 6:00 PM (GMT +8:00)
Method Details
Phone + 60 (3) - 8068 1929
Fax + 60 (3) - 8068 1922
Internet www.entrypass.net
Email support@entrypass.net
Before you begin
ENTRYPASS
3
Model: EP.MINI

CAUTION
Battery may explode if mistreated. Do not recharge, disassemble
or dispose of in fire. To prevent a risk of explosion do not pry the
battery out with a metal or conductive tool.
Considerations Prior to Installation
Preparing Your EntryPass Controllers
EntryPass controller contains numerous delicate electronic circuits and components which can become damaged
as a result of electrostatic discharge (ESD). Thus, prior to installation, please follow the instruction below:
•Observe precautions while handling the circuit board assembly by using proper grounding straps and handling
precautions at all
•Visually ensure no onboard parts is broken, damage or contains burn mark
•Do not turn on the power supply until you completed all wiring and external add on devices installations
Instances of Non-Warranty
•Damage due to natural disaster, accident or human cause.
•Damage as a result of violating the conditions recommended in the user manual
•Damage due to improper installation
•Damage due to use of uncertified components
•Damage due to use exceeding the permitted parameters
ENTRYPASS
4
Model: EP.MINI

Model: EP.MINI
MiNi Description
MiNi Reader
Keypad Display Unit
Encrypted Lock Control
(ELC)
ENTRYPASS
5

Model: EP.MINI
ENTRYPASS
MiNi Color Description
Encrypted Lock Control (ELC) Description
Red : +12VDC
Black : GND / 0VDC
Orange : RCLK
Yellow : RDAT
Blue : RTX
Pink : Push Button
Red : +12VDC
Black : GND / 0VDC
Grey / Yellow : NO1
White / Blue : CM1
White : NC1
Brown : NO2
Grey : CM2
Green : NC2
Purple : +12Vdc Lock
Purple : +12Vdc Lock
MiNi Reader Color Description
Red : +12VDC
Black : GND / 0VDC
Pink : Door Sensor
Black : GND / 0VDC
Blue : RTX
Brown : + 5VDC
White : Exit Reader D1
Green : Exit Reader DO
Orange : RCLK
Yellow : RDAT
Grey : RS485 C+
Purple : RS485 C-
Green : RS232 RX Separated
White : RS232 TX Separated
6

Model: EP.MINI
MiNi reader keypad display unit
ENTRYPASS
White LCD Display
Enter Key
Numbered Keypad
Navigation Pad
LED Indicator
7

Power Supply Unit Specification
ENTRYPASS
8
Model: EP.MINI
Power Supply Unit Specification:
•Switching Power Supply
•12V DC
•3 Amp (Minimum)
ENTRYPASS

Model: EP.MINI
Connecting MINI to ELC
ENTRYPASS
0 V +12 VDC
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
Red (+12VDC)
Black (Gnd)
Red (+12VDC)
Black (Gnd)
Blue (RTX) Blue (RTX)
Orange (RCLK) Orange (RCLK)
Yellow (RDAT) Yellow (RDAT)
The distance from MINI keypad reader to ELC should not more than 10 meter
9

Model: EP.MINI
Connecting the Lock (NC), Breakglass and Keyswitch to ELC
ENTRYPASS
+-
White/Blue (CM1)
White (NC1)
0V
Emergency
Breakglass
Emergency
Keyswitch
Electro-Magnetic Lock
-
+
Purple (+12VDC)
Purple (+12VDC)
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
Diode(1N4002) must be installed at the locking devices in order to protect against back EMF
10

Model: EP.MINI
Connecting the Lock (NO)
ENTRYPASS
11
Diode(1N4002) must be installed at the locking devices in order to protect against back EMF
+-
White/Blue (CM1)
Grey/Yellow (NO1)
0V
Electro-Magnetic Lock (Drop Bolt)
-
+
Purple (+12VDC)
Purple (+12VDC)
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)

Model: EP.MINI
Connecting the Door Sensor and Door Release Button/Push Button
ENTRYPASS
The distance from door sensor to MINI and from push button to ELC should not more than 30 meter
12
DoorSensor PushButton
Pink(DoorSensor)
Black(Gnd)
Pink(PushButton)
Black(Gnd)

Model: EP.MINI
Connecting the Exit Reader –MINI reader as an exit reader
ENTRYPASS
To use MINI/NMINI on exit reader side, you must enable the READER MODE function on the
programming mode
To configure MINI as a
READER Mode, press:
•F1
•123456
•01 Enter
•01 Enter
•05 Enter
•1 Enter
•ESC x3
To configure NMINI as a
READER Mode, press:
•F1
•123456
•01 Enter
•01 Enter
•04 Enter
•1 Enter
•ESC x3
0 V +12 VDC
Exit Reader
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
Green (D0)
White (D1)
Black (Gnd)
Red (+12VDC)
Black (Gnd)
Red (+12VDC)
Orange (RCLK)
Yellow (RDAT)
13

Model: EP.MINI
Connecting the Exit Reader –3rd Party Reader
ENTRYPASS
0 V +12 VDC
Green (D0)
White (D1)
Black (Gnd)
Red (+12VDC)
Green (D0)
White (D1)
Exit Reader
Black (Gnd)
Red (+12VDC)
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
The distance from MINI to exit reader should not more than 10 meter
14

Model: EP.MINI
Configuring the MINI Unit Address
ENTRYPASS
15
Unit Address
Software address field
00
255.255.255.0
01
255.255.255.1
02
255.255.255.2
03
255.255.255.3
04
255.255.255.4
05
255.255.255.5
06
255.255.255.6
07
255.255.255.7
08
255.255.255.8
09
255.255.255.9
10
255.255.255.10
11
255.255.255.11
12
255.255.255.12
13
255.255.255.13
14
255.255.255.14
15
255.255.255.15
To configure MINI unit address
(default: 00), press:
•F1
•123456
•01 Enter
•01 Enter
•04 Enter
•Key in new unit address (00 –15)
•ESC x3
The unit address that you configure on the MINI
controller will determine the controller address on the
EntryPass Platform1 Access Control System software

Model: EP.MINI
Connecting to the PC using RS 232 mode
ENTRYPASS
The distance from computer to MINI should not more than 10 meter
DB 9 Female Connecter
White to Pin 2
Green to Pin 3
Black to Pin 5
Green (RS 232 RX)
White (RS 232 TX)
Black (Gnd)
EntryPass Platform1
Server Access
Control System
16

Model: EP.MINI
Connecting to the PC using RS 485 mode
ENTRYPASS
To configure MINI unit address
(default: 00), press:
•F1
•123456
•01 Enter
•01 Enter
•04 Enter
•Key in new unit address (00 –15)
•ESC x3
17
When the implementation consists of more than 1 MINI to be connected to the
PC using the same bus/comport, the unit address for each MINI must be unique.
Only a total of 16 controllers can be connected to each bus/comport.
Purple (C-)Purple (C-)
Grey (C+)Grey (C+) Grey (C+)
C-
C+
Purple (C-)
MINI 16
Unit Address: 15
MINI 2
Unit Address: 01
MINI 1
Unit Address: 00
PCC
(Pc Communicator)
RS 232: 10 meter
RS232
Power
Tx
Rx
EntryPass Platform1
Server Access
Control System
RS 485: I000 meter (Maximum)

Model: EP.MINI
Connecting to the power supply unit
ENTRYPASS
0 V +12 VDC
Red/Yellow (+12VDC)
Black (Gnd)
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
18

Model: EP.MINI
Complete overview
ENTRYPASS
19
+-
White/Blue(CM1)
0V
Emergency
Breakglass
Emergency
Keyswitch
Electro-MagneticLock
-
+
Purple(+12VDC)
Door
Sensor
Push
Button
Black(Gnd)
Exit
Reader
Black(Gnd)
Red/Yellow(+12VDC)
+12VDC
SwitchingMode
PowerSupplyUnit
(12VDC,3AMinimum)
EntryPassPlatform1
ServerAccess
ControlSystem
White(NC1)
Orange(RCLK)
Yellow(RDAT)
Blue(RTX)
Pink(PushButton)
Red(+12VDC)
Black(Gnd)
Orange(RCLK)
Yellow(RDAT)
Blue(RTX)
Red(+12VDC)
Green(D0)
White(D1)
Black(Gnd)
Pink(DoorSensor)
RS232
Power
Tx
Rx
Grey(C+)
Purple(C-)
PCC
(PcCommunicator)
C+
C-

Model: EP.MINI
ENTRYPASS
Before connecting to the EntryPass Platform1 Access Control System
Before you begin to connect to the EntryPass Platform1 Access Control System, please make sure
all the wiring connection is correct. On the MINI keypad, please make sure the following setting
has been done:
Format Memory
Unit Address
Advisable to
perform format
memory for the
first time you turn
on the power
To configure the
EP.MINI unit address
when there is more
than one MINI
controller connected
to the PC
communicator
20
Other manuals for EP.MINI
1
Table of contents
Other ENTRYPASS Control System manuals
Popular Control System manuals by other brands

Mitsubishi Electric
Mitsubishi Electric AG-150A-A installation manual

AB Quality
AB Quality Allen-Bradley 1394 user manual

Vibration Research
Vibration Research VR8500 quick start guide

Motorola
Motorola DOCKCONTROLLER DC-200 quick start guide

RFDesign
RFDesign RFD TX Pole user manual

Tyco
Tyco Raychem HWAT-ECO Installation and operation manual